• 제목/요약/키워드: heating and cooling

검색결과 1,923건 처리시간 0.028초

철도차량 냉방 및 난방장치의 환경성능 시험방안 연구 (Study on the environmental performance test of cooling and heating equipments' of passenger cabin)

  • 조영민;이준석;박덕신;권순박;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.223-228
    • /
    • 2009
  • Cooling and heating equipments of railroad passenger cabin is one of the most important part in keeping the good thermal comfort of the passengers. The bad performance of these equipments usually results in the comfort of the passengers. However, there is no testing method for cooling and heating equipments during manufacturing the passenger car, and calculation method is frequently used. Many railroad operators spend a lot of money for the maintenance. In this study, a new environmental performance test for railroad passenger cabin was suggested. The temperature of the chamber will be changed from $-40^{\circ}C$ to $60^{\circ}C$. The performance test of cooling and heating equipment in controlling the passenger cabin temperature was carried out under various temperature condition. The testing method to investigate the effect of artificial sunlight irradiation on the passenger cabin temperature was also suggested.

  • PDF

50kg/mm$^{2}$급 고장력 강판의 선상가열에 따른 판상변형과 재질변화 (Distortion and transformation of high tensile strength steel plate of 50kg/mm$^{2}$grade due to line heating)

  • 정남호;최병길;박종은
    • Journal of Welding and Joining
    • /
    • 제3권1호
    • /
    • pp.11-21
    • /
    • 1985
  • The line heating is a thermoplastic working technique which is used in bending work of steel plate and in correcting the distortion of welded structure. This method is considerably effective when the water-cooling is followed. In this study, an investigation was accomplished to find the effects on the change of material properties when the line heating was applied on the high tensile steel plate of 50kg/mm^2$ grade. Some steel plates were heated to various temperatures and then cooled with water or in the air. In this study, the author measured the angular distortion continuously during line heating to find out the relation between the bending efficiency and heating or water-cooling temperature. Furthermore, its material properties were examined by the V-notch Charpy impact test, the microscope observation and the Vickers hardness test. As results, the followings were clarified. (1) The amount of angular distortion increases as the heating temperature or the water-cooling temperature rises. (2) When the steel plate is heated between 700.deg. C and 900.deg. C, and then is water-cooled over 700.deg. C, some brittle structure is observed. But if the temperature of water-cooling is below 700.deg. C, no brittle one is found. (3) When the steel plate is heated over 800.deg. C and is cooled in the air, there is no unfavrable effect.

  • PDF

75% 수소 BATCH 소둔시에서의 코일 온도변화에 관한 연구 (A study on coil temperature bariation in 75% hydrogen batch annealing furnace)

  • 전언찬;김순경
    • 한국정밀공학회지
    • /
    • 제11권2호
    • /
    • pp.173-181
    • /
    • 1994
  • A Cold spot temperature control system for the batch annealing furnace has been estabilished in order to reduce energy consumption to improve productivity and stabilize the propertics of products. Therefore we confirmed a relation between annealing cycle time and atmospheric gas, variation of coil cold spot temperature with time during heating and actual temperature measurements at mid-width of each coil during heating and actual temperature measurements at mid-width of each coil during soaking. The results of the tempaeature variation effect on the batch annealing are as follows. 1) Heating time is reduced to one half with increasing atmospheric gas flow rate and changing of atmospheric gas component from HNx to Ax gas, and annealing cycle time is reduced to 2.7 times. 2) In case of short time healing, the slowest heating part is the center of B coil, in case of long time heating, the low temperature point moves from the center of coil to inside coil. And the temperature in this part is higher than other parts when cooling. When finished heating, the cold spot is located 1/3 of coil inside in case of HNx atmospheric gas. But center of coil in case of Ax atmospheric gas. 3) The outside of top coil is the highest temperature point when heating, which becomes the lowest temperature point when cooling. So, this point becomes high temperature zone at heating and low temperature zone at cooling, It has relation according to atmospheric gas component and flow rate. 4) Soaking time at batch annealing cycle determination is made a decision by the input coil width, and soaking time for quality homogenization of 1214mm width coil must be 2.5 hours longer than that of 914mm width coil for the same ciol weight. 5) Annealing cycle time with Ax atmospheric gas is extended 1 hour in of slow cooling during 5 hours in order to avoid rapid cooling.

  • PDF

에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구 (The optimal window system of office buildings considering energy efficiency)

  • 유호천;오영호;박승길
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.53-60
    • /
    • 2005
  • The purpose of this study is to improve energy efficiency of windows in office buildings through the evaluation of their heating, cooling and illumination load. Energy efficiency is influenced by window size which is determined at the early stage of building design. The process of this study is as follows. First, energy performance is analysed according to the various rates of windows through computer simulation (ECOTECT). Then, the annual heating, cooling and illuminating loads according to the different window sizes are compared one another. Results indicated that the optimal window size considering energy efficiency is 50% of the surface area. When the window size is 50% of the surface area, annual maintenance expense is also smallest. Since the cost of cooling is larger than that of heating, too low indoor air temperature in summer is unfavorable based on the reasonable annual maintenance expenses.

냉난방도일을 이용한 우리나라 주요도시의 도시승온화현상 특성분석 (Analysis of Urban Warming Phenomenon using Degree days in Major Korean Cities)

  • 김해동;박명희;송경숙
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.189-196
    • /
    • 2004
  • Characteristics of urban wanning phenomenon were studied using degree days for three big cities(Seoul, Busan, Daegu) adjacent to airport. Time variation of the cooling and heating degree days was analyzed using the daily mean air temperature data measured at the six meteorological observatory for long-term periods(25~43years). The results for the big cities are as followings: 1) It was found that the heating degree days trended to decrease from year to year. 2) The cooling degree days were nearly unchanged during the same analysis periods. 3) The number of days calling for air-heating also tended to decrease as time passes. 4) Those of air-cooling were nearly unchanged during the same time. It suggests that the change of air-heating condition owing to urbanization came in evidence in the winter season, but that of air-cooling condition was slight in the summer season. On the other hand, the long-term trends of degree days were very small in airport areas except for Kimhae airport. Hence, the gaps of degree days between big cities and rural airport areas are increasing.

인테이크 도어 제어를 이용한 고성능 냉난방 시스템 (Air Intake Door Control for the High Air Conditioning Performance)

  • 박동규;김용철
    • 한국자동차공학회논문집
    • /
    • 제22권2호
    • /
    • pp.17-22
    • /
    • 2014
  • Recently, the quick heating performance is an important issue in the car because engine power becomes so high. So car makers have been adapted the additional heating devices as like PTC(Positive Temperature Coefficient) heater. And the quick cooling performance is also important issue because its result is used in the IQS(Initial Quality Study). In this paper, control of the HVAC(Heating, Ventilation and Air Conditioning) intake door has been studied for the quick heating and cooling performance. Heating performance is improved $4.0^{\circ}C$ at $-20^{\circ}C$ ambient temperature after 20 minutes. And cooling performance is improved $1.5^{\circ}C$ at $35^{\circ}C$ ambient temperature after 10 minutes. In addition, intake door control system brings on the cost reduction because the flab door can be eliminated. This intake door control system has been adapted to the new developing cars.

온실의 냉난방시스템 설계용 외부기상조건 분석 (Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea)

  • 남상운;신현호
    • 생물환경조절학회지
    • /
    • 제25권4호
    • /
    • pp.308-319
    • /
    • 2016
  • 온실의 냉난방시스템 설계 기준에 적용하기 위한 외부기상조건을 설정하기 위하여 난방 설계용 외기온, 난방 degree-hour, 냉방 설계용 건구온도, 습구온도, 일사량을 분석하여 제시하였다. 우리나라 전 지역을 대상으로 현재 기상청에서 제공하는 기후평년값 기준인 1981~2010년까지 30년간의 매 시각 기상자료를 분석에 사용하였다. 표준기상데이터의 이용이 제한적이기 때문에 30년간의 전체 기상자료를 이용하여 설계용 기상조건을 구하고, 전체 자료기간의 평균값을 설계기준으로 제시하였다. TAC 방식으로 위험률 1, 2.5, 5%에 대한 설계용 기상자료를 분석하고, 설계기준에서 추천하고 있는 난방용은 위험률 1%, 냉방용은 위험률 2.5%의 기상조건 분포도를 제시하였다. 지역별, 위험률별 및 설정온도별로 최대난방부하, 기간난방부하 및 최대냉방부하의 변화를 고찰하였다. 제시된 각종 설계용 기상조건은 온실의 냉난방시스템 설계에 직접 이용할 수 있을 뿐만 아니라 냉난방 설비 보강이나 에너지 절감대책의 수립에 활용이 가능할 것으로 판단된다. 한편 기후변화로 인하여 최근 여름철 폭염이나 겨울철 이상고온 현상이 자주 발생하고 있으므로 주기적인 설계용 기상자료의 분석이 필요하고, 최소한 10년 주기로 설계기준을 개정할 필요가 있는 것으로 생각된다. 본 연구에서는 현재 기후평년값 기준인 1981~2010년까지의 기상자료를 분석하였으나 이 기준이 1991~2020년으로 바뀌는 2021년에는 즉시 이 기간의 기상자료를 분석하여 새로운 설계기준으로 제공해야 할 것으로 판단된다.

기후변화와 사회·경제적 요소를 고려한 가정 부문 냉난방 에너지 사용량 변화 예측 (Prediction of Heating and Cooling Energy Consumption in Residential Sector Considering Climate Change and Socio-Economic)

  • 이미진;이동근;박찬;박진한;정태용;김상균;홍성철
    • 환경영향평가
    • /
    • 제24권5호
    • /
    • pp.487-498
    • /
    • 2015
  • 기온상승과 인구 및 GDP 증가의 영향으로 인해 에너지 문제가 발생하고 있다. 이러한 문제에 대응하기 위해 에너지 수요에 대한 예측이 필요하다. 따라서 본 연구는 에너지 수요관리, 특히 전력부하를 유발하는 냉난방 에너지 수요 관리에 도움이 되고자 가정 부문 냉난방 에너지의 미래 사용량을 예측하고자 한다. 에너지 사용량을 산정하는데 있어 서비스 수요의 산출이 필요하다. 따라서 서비스 수요 산정식을 이용하여 이를 먼저 도출하고, AIM/end-use 모델을 이용하여 에너지 사용량을 산정하였다. 산정 결과 냉난방 서비스 수요는 2010년에 비해 2050년에 모두 증가하는 추세를 보였다. 하지만 에너지 사용량에서 난방은 감소하고, 냉방은 증가하는 것으로 예측되었다.

외단열 벽체에서 창호 설치 위치에 따른 단열성능 및 냉난방 에너지 소비량 (Insulation Performance and Heating and Cooling Energy Consumption depending on the Window Reveal Depth in External Wall Insulation)

  • 이규남;정근주
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.91-98
    • /
    • 2017
  • In this study, the effect of window installation position in the residential building with the external insulation was numerically investigated in terms of insulation performance and heating/cooling energy consumption. For different window positions, 2-D heat transfer simulation was conducted to deduce the linear thermal transmittance, which was inputted to the dynamic energy simulation in order to analyze heating/cooling energy consumption. Simulation results showed that the linear thermal transmittance ranges from 0.05 W/mK to 0.7 W/mK, and is reduced as the window is installed near the external finish line. Indoor surface temperature and TDR analysis showed that the condensation risk is the lowest when the window is installed at the middle of the insulation and wall structure. It was also found that the window installation near the external finish can reduce the annual heating/cooling energy consumption by 12~16%, compared with the window installation near the interior finish. Although the window installation near the external finish can achieve the lowest heating/cooling energy consumption, it might lead to increased condensation risks unless additional insulation is applied. Thus, it can be concluded that the window should be installed near the insulation-wall structure junction, in consideration of the overall performance including energy consumption, condensation prevention and constructability.

반용융 성형에서 강제 표면 냉각에 의한 유도 가열 방법에 관한 연구 (A Study on Induction Heating with Forced Surface Cooling in Semi-Solid Forming Process)

  • 박준홍;최영
    • 한국정밀공학회지
    • /
    • 제22권1호
    • /
    • pp.97-102
    • /
    • 2005
  • The procedure of semi-solid forming is composed of heating a billet, forming, compression holding and ejecting step. There are several methods to heat a billet during semi-solid forming process such as electric heating and induction heating. Usually in semi-solid forming process, induction heating has been adopted to achieve more uniform temperature of semi-solid material. Although induction heating is better method than any others, however, there is still difference of temperature between internal part and surface part of semi-solid material. Worse yet, in case of high liquid fraction of semi-solid material, liquid of the billet will flow down though solid of the billet still remains, which is very difficult to handle. In the present study, induction heating of semi-solid material with compulsive surface cooling has been performed to obtain uniform distribution of temperature. Distribution of temperature of the billets was measured and compared with that of conventional distribution of temperature. By this new induction heating method, not only temperature over the whole billet become uniform, but also control of temperature is possible.