• 제목/요약/키워드: heat value

검색결과 2,739건 처리시간 0.034초

생태도시에서의 자원활용에 관한 연구 - 주택 에너지 시스템 개선을 위한 하수 에너지흐름 분석 - (Study on Utilizing Resources in Ecopolis - Evaluation of Energy floors of Sewage for Enhanced energy system of residence -)

  • 정용현
    • 한국환경과학회지
    • /
    • 제12권9호
    • /
    • pp.911-919
    • /
    • 2003
  • When the city water was heated for the optimum use of unused energy, the energy flows and losses were calculated and evaluated to improve the value of heated water systems at dwelling side. To obtain this purpose, it was simulated on heat flows under two conditions like with heat pumps or not and calculated the energy sayings. Furthermore, recycling water system was suggested for enhancing the value of heated water system. From this results, the energy flows without heat pumps showed that it was 3-4 percents of heat losses from pipes, 62 percents of energy savings from hot water uses and 34 percents of unutilized heat. When the heated water system adopt the recycling water system at dwelling side, it was improved 12 percents of total energy sayings.

연료전지 냉각용 헬리컬 인서트디바이스 이중관열교환기의 열전달 성능 향상에 관한 연구 (A Study on the Improvement of Efficiency of Heat Transfer of Double Pipe Heat Exchanger with Helical Insert Device on Cooling of a Fuel Cell)

  • 조동현
    • 수산해양교육연구
    • /
    • 제27권6호
    • /
    • pp.1872-1879
    • /
    • 2015
  • The present study was conducted on the improvement of the heat transfer performance of double pipe heat exchangers with helical insert device. Double pipe heat exchangers with helical insert device were studied for improvement of the heat transfer performance of double pipe heat exchangers with helical insert device and plain double pipe heat exchangers were also studied to comparatively analyze heat transfer performance. Experimental results were derived on changes in the Reynold's numbers of the cooling water flowing in helical and plain double pipe heat exchangers and changes in the heat flux of the air. Thereafter, to verify the reliability of the experimental results, the theoretical total energy and the experimental total energy were comparatively analyzed and the following results were derived. The thermal energy of the calorie lost by the hot air and that of the calorie obtained by the cooling water were well balanced. The experiments of plain double pipe heat exchangers and double pipe heat exchangers with helical insert device were conducted under normal conditions and the theoretical overall heat transfer coefficient value and the experimental overall heat transfer coefficient value coincided well with each other. In both plain double pipe heat exchangers and double pipe heat exchangers with helical insert device, heat transfer rates increased as the cooling water flow velocity increased. Under the same experimental conditions, the heat transfer performance of double pipe heat exchangers with helical insert device was shown to be higher by approximately 1.5 times than that of plain double pipe heat exchangers.

저탄소강의 미세조직과 집합조직에 대한 탄소의 영향 (Effect of Carbon on Microstructure and Texture in Low Carbon Steels)

  • 정우창
    • 열처리공학회지
    • /
    • 제27권2호
    • /
    • pp.79-89
    • /
    • 2014
  • The effect of carbon on the microstructure and texture of low carbon steels was investigated in a series of 1.6 Mn-0.3Cr-0.2Mo-0.001B steels with carbon ranging from 0.021 to 0.048%. Intensity of {111} orientation increased with decreasing the carbon content, resulting in the increase in $r_m$ value. The highest $r_m$ value of 1.30 was obtained in 0.021%C steel annealed at $820{\sim}850^{\circ}C$ according to the typical galvannealing heat cycle. Martensite volume fraction was not substantially affected by the annealing temperature. It was found that the fine and uniformly distributed martensite particles which were present in amounts of about 5% volume fraction were desirable for the highest $r_m$ value. The other factor affecting the high $r_m$ value was the preferred epitaxial growth of retained ferrite with {111} orientation into austenite during cooling.

마르텐사이트계 내열강의 금속 및 기계적 특성에 관한 연구 (A Study on the Internal Quality and the Machining Characteristics of Martensitic Heat Resisting Steel)

  • 채왕석;권용기;김동현
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.1073-1077
    • /
    • 1997
  • In this paper, we have studied internal quality including chemical compositions, microscopic structure and nonmetalic inclusion of test materials. We have analyzed machining characteristics including tensile strength value, impact value, hardness value etcs. Test materials are usd martensitic heat resisting steel, STR11 and STS420J2. The obtined results are as follows : 1. In analyzing internal quality, STR11 and STR420J2 have typical martensite structure and a minute needle-shaped structure. 2. Tensile strength and reduction of area and hardness value are large STR11 than STS420J2. But elongation impact are smaller STR11 than STS420J2. 3. Fracture surface of tensile speciman is ductile in STR11 and STS420J2.

  • PDF

팜(PALM) 기름 안정성 향상을 위한 항산화제 적정첨가조건 조사 (Studies on the Find out of Optimum Condition with Treated Antioxidants for the Stability of PALM Oil after Frying)

  • 이형재;이성갑
    • 기술사
    • /
    • 제31권5호
    • /
    • pp.110-120
    • /
    • 1998
  • The effect of heat treatment and the order of antioxidants treatment toward the thermally oxidized palm oil which has been stored at 60 $^{\circ}C$ was studied. The summerized results of this study are as follows; 1. In the accelerated autoxidation condition, tocopherol showed no distinct effect on the changes of peroxide of value between added tocopherol samples pre-and post treatment by heating. But, rosemary extract showed opposite result. It was supposed that rosemary extract had lower thermostability then tocopherol, because rosemary extract lost it's antioxidative activity during heating process. 2. The changes of acid value and anisidine value were more affected by heat treatment than the order of antioxidant treatment. 3. The oxidative stability measured by OSI showed same tendency as peroxide value. That is, the antioxidative activity of tocopherol in palm oil was more dependent on addition of antioxidants than heat treatment, but the rosemary extract had opposite character for antioxidative action in palm oil.

  • PDF

동절기 단열갱폼의 발열량 변화 측정에 관한 연구 (A Study on the Calorific Value of Insulated Gang-form in Winter)

  • 강인선;원준연;김태희;김성덕;최석;남경용
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.135-136
    • /
    • 2017
  • This paper examines the efficiency of the application of conventional and insulated gang forms for curing and protection of concrete by comparing the amount of electric energy required therefor. In addition, a thermal vision camera was used to identify heat loss from surfaces of the gang forms after each placement of concrete. Experimental results, show that the heat loss at the submerged temperature was large at the submerged surface due to the large calorific value at the surface of the mold. The insulated gang form had some heat loss in the horizontal bars. In the case of adiabatic reforming, the pattern shows a constant calorific value over time. In conclusion, the insulation performance is better than that of general gang form.

  • PDF

상부가열인 다공물질내의 열파이프 현상에 관한 실험적 연구 (Experimental study of the heat pipe phenomenon in porous media heated from above)

  • 이진호;김홍제;함윤영;남궁규완
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.825-832
    • /
    • 1988
  • 본 연구에서는 1차원 열흐름하에서 상부가 가열된 다공물질내의 열파이프 현 상과 관련하여 2상영역의 존재와 그 길이에 영향을 미치는 인자들을 실험적으로 관찰, 조사하였다.

직교하는 단락형 리브를 부착한 판형 열교환기 관내측 열유동 해석 (The Thermal and Flow Analysis in the Channel of Plate Heat Exchanger with Crossed-Discrete Ribs)

  • 이관수;문형규;정길완
    • 대한기계학회논문집B
    • /
    • 제23권5호
    • /
    • pp.678-686
    • /
    • 1999
  • The purpose of this work is to Investigate the pressure drop and the heat transfer characteristics in the channel of plate heat exchanger with crossed-discrete ribs. The flow is assumed to be three-dimensional, laminar and periodically fully developed. Computations have been carried out for angles of attack from $0^{\circ}$ to $90^{\circ}$ and ratios of rib height from 0.15 to 0.46 for various values of Reynolds and Prandtl numbers. The heat transfer was improved by inclined ribs generating helical vortices and secondary flows. The results show that the pressure drop has a maximum value at $70^{\circ}$ and the heat transfer has a maximum value at $45^{\circ}$. As the rib height increases, the pressure drop and the heat transfer increase quadratically, and the increasing rate of pressure drop is higher than that of the heat transfer. As Reynolds number increases, the pressure drop increases in proportion to the square of Reynolds number and the heat transfer increases linearly.

한열 변증 설문지 개발에 관한 연구 (Study on Development of Cold-Heat Pattern Questionnaire)

  • 유현희;이혜정;장은수;최선미;이성근;이시우
    • 동의생리병리학회지
    • /
    • 제22권6호
    • /
    • pp.1410-1415
    • /
    • 2008
  • Acupuncture and herbal treatment are based on diagnosis of cold and heat pattern in Traditional Korean Medicine. This diagnosis is accomplished through pulse, tongue and question examination, which are not objective. Quantification and objectification of this diagnosis process are required for efficacious treatment and traditional medicine development. In this study, we developed the cold-heat pattern questionnaire for this purpose. Seventy nine patients who visited oriental medical hospital were included in this study. The cold-heat pattern questionnaire was composed of many questions about patient's physical condition, which were derived from The Traditional Oriental Medical Literature with Delphi Technique. Patients filled out the cold-heat pattern questionnaire by themselves. Diagnosis of cold and heat pattern are conducted separately by oriental medical doctors with more than 5 years' clinical experience. Various physical condition factors were derived for the cold-heat pattern questionnaire. (Preference temperature, Body temperature, Pain type, Face color, Urine, Stool and secretion features) Each cold and heat symptoms group acquired internal consistency. (Cronbach's ${\alpha}$ : Cold - 0.605, Heat - 0.722) There were significant associations between doctor's diagnosis and cold symptoms in 'Aversion to cold', 'Desire for heat', 'Pale face', 'Loose stools'. (p-value < 0.05) There were significant associations between doctor's diagnosis and heat symptoms in 'Desire for cold', 'Body feverishness', 'Thirst'. (p-value < 0.05) The internal consistency results suggest that the cold-heat pattern questionnaire assured reliability. Besides, these results showed that cold-heat symptoms are apt to appear together with, and this can be indirect evidence that diagnosis of cold-heat pattern is valuable for comprehension about disease pattern. Moreover, respective symptoms of cold-heat pattern showed different significance with doctor's diagnosis. Consequently these significant symptoms can be more considered for comprehension of cold-heat pattern.