• 제목/요약/키워드: heat transfer mode

검색결과 150건 처리시간 0.024초

열광학 효과를 이용한 SOI $1\times24$ 비대칭 광스위치 설계 및 제작 (Design and fabrication of SOI $1\times2$ Asymmetric Optical Switch by Thermo-optic Effect)

  • 박종대;서동수;박재만
    • 대한전자공학회논문지SD
    • /
    • 제41권10호
    • /
    • pp.51-56
    • /
    • 2004
  • 광소자의 재료물질로서 특성이 우수하며 열광학계수가 큰 silicon을 기반으로 한 SOI (Silicon-on-insulator)를 사용하여 열광학 1×2 광스위치를 제안, 제작하였다. SOI wafer는 도파로가 형성될 상위 Si 층(n=3.5)과 클래딩 영역이 될 산화막 매립층(n=1.5) 그리고 기판인 Si인 3층으로 이루어진다. BPM(Beam propagation method) 전산모의를 통해 20dB 이상의 누화특성을 갖는 단일모드의 1×2 비대칭 y-분기 광도파로를 형성하고, 열확산 전산모의를 통해 금속열선을 설계 제작하였다. 제작된 광스위치는 약 3.5 watts의 구동 전력에서 20dB 이상의 채널간 누화가 측정되었다.

100마력 고온초전도 동기전동기 개발 (Development of a 100 hp HTS Synchronous Motor)

  • 손명환;백승규;이언용;권영길;조영식;김종무;문태선;김영춘;권운식;박희주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권2호
    • /
    • pp.94-100
    • /
    • 2005
  • Korea Electrotechnology Research Institute(KERI) has successfully developed a 100hp-1800rpm-class high temperature superconducting(HTS) motor with high efficiency under partnership with Doosan Heavy Industries & Construction Co. Ltd. This motor has a HTS field winding and an air-cooled stator. The advantages of HTS motor can be represented by a reduction of 50% in both losses and size compared to conventional motors of the same rating. The cooling system is based on the heat transfer mechanism of the thermosyphon by using GM cryocooler as cooling source. The cold head is in contact with the condenser of a Ne-filled thermosyphon. Independently, the rotor assembly was tested at the stationary state and combined with stator. The HTS field winding could be cooled into below 30K. Test of open-circuit characteristics(OCC) and short-circuit characteristics(SCC) and load test with resistive load bank were conducted in generator mode. Also, load tests in motor mode driven by inverter were finished at KERI. Maximum operating current of field winding at 30K was 120A. From OCC and SCC test results synchronous inductance and synchronous reactance were 2.4mH, 0.49pu, respectively. Efficiency of this HTS machine was 93.3% in full load(100hp) test. This paper will present design, construction. and experimental test results of the 100hp HTS machine.

상분리 조절에 의한 PVDF막의 구조 변화 (Structural Changes of PVDF Membranes by Phase Separation Control)

  • 이세민;김성수
    • Korean Chemical Engineering Research
    • /
    • 제54권1호
    • /
    • pp.57-63
    • /
    • 2016
  • Polyvinylidene fluoride (PVDF) 평막 제조를 위하여 PVDF의 용매와 희석제로서 n-methyl-2-pyrrolidone (NMP)와 dibutyl-phthlate (DBP)를 각각 사용하여 열유도 상분리(thermally induced phase separation, TIPS)와 비용매유도 상분리(nonsolvent induced phase separation, NIPS)를 동시에 유도하였다. NMP와 DBP를 PVDF와 용융 혼합할 경우 TIPS 공정에서의 결정화 온도가 낮아졌고 NIPS 공정에서의 불안정 영역이 확대되었다. 용매와 희석제의 비율에 따라 상분리 메카니즘이 변화하였고 이에 따라 다양한 구조의 막이 형성됨을 확인하였다. 또한 dope 용액과 비용매의 접촉여부에 따라 지배적인 상분리 거동이 결정되었다. 열전달이 물질전달에 비하여 빠르게 이루어지므로 막의 표면은 NIPS에 의하여 지배를 받고 막의 내부는 TIPS에 의한 구조가 형성되었다. 또한 dope 용액의 급냉온도에 따라 상분리 메카니즘 및 상분리 속도가 변화하여 다양한 구조를 형성하였다.

혁신형 안전경수로의 원자로용기 외벽냉각 시 2상 자연순환 유동에 대한 수치해석적 연구 (Numerical Study on Two-phase Natural Circulation Flow by External Reactor Vessel Cooling of iPOWER)

  • 박연하;황도현;이연건
    • 에너지공학
    • /
    • 제28권4호
    • /
    • pp.103-110
    • /
    • 2019
  • 국내에서 개발 중인 차세대 혁신형 안전경수로인 iPOWER는 피동용융노심냉각계통의 도입을 통해 중대사고시 노심용융물을 원자로 하부에서 장기간 냉각하고 안정화시키고자 한다. 아직 피동용융노심냉각계통의 최종 설계개념이 확정되기 전이나, 원자로용기 외벽냉각을 통한 노심용융물의 노내 억류 역시 주요 중대사고 대처 전략의 하나로 검토되고 있다. 본 연구에서는 국내에서 개발된 열수력 계통해석코드인 MARS-KS를 이용하여 원자로용기와 단열체 사이에서 형성되는 2상 자연순환 유동을 모의하였다. 냉각수의 유로를 일차원으로 모델링하고, 노심용융물의 열부하에 따른 경계조건을 정의하여 자연순환 유량을 계산하였다. 또한 냉각수의 온도 및 수위, 원자로용기 하반구 주변 기포율 및 외벽에서의 열전달모드 등 주요 열수력 변수의 과도거동을 평가하였다.

Investigation of 0.5 MJ superconducting energy storage system by acoustic emission method.

  • Miklyaev, S.M.;Shevchenko, S.A.;Surin, M.I.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.961-965
    • /
    • 1998
  • The rapid development of small-scale (1-10 MJ) Superconducting Magnetic Energy Storage Systems (SMES) can be explained by real perspective of practical implementation of these devices in electro power nets. However the serious problem of all high mechanically stressed superconducting coils-problem of training and degradation (decreasing) of operating current still exists. Moreover for SMES systems this problems is more dangerous because of pulsed origin of mechanical stresses-one of the major sources of local heat disturbances in superconducting coils. We investigated acoustic emission (AE) phenomenon on model and 0.5 MJ SMES coils taking into account close correlation of AE and local heat disturbances. Two-coils 0.5 MJ SMES system was developed, manufactured and tested at Russian Research Center in the frames of cooperation with Korean Electrical Engineering Company (KEPCO) [1]. The two-coil SMES operates with the stored energy transmitted between coils in the course of a single cycle with 2 seconds energy transfer time. Maximum operating current 1.55 kA corresponds to 0.5 MF in each coil. The Nb-Ti-based conductor was designed and used for SMES manufacturing. It represents transposed cable made of Nb-Ti strands in copper matrix, several cooper strands and several stainless steel strands. The coils are wound onto fiberglass cylindrical bobbins. To make AE event information more useful a real time instrumentation system was used. Two main measured and computer processed AE parameters were considered: the energy of AE events (E) and the accumulated energy of AE events (E ). Influence of current value in 0.5 MJ coils on E and E was studied. The sensors were installed onto the bobbin and the external surface of magnets. Three levels of initial current were examined: 600A, 1000A, 2450 A. An extraordinary strong dependence of the current level on E and E was observed. The specific features of AE from model coils, operated in sinusoidal vibration current changing mode were investigated. Three current frequency modes were examined: 0.012 Hz, 0.03 Hz and 0.12 Hz. In all modes maximum amplitude 1200 A was realized.

  • PDF

화재시 구조강도에 대한 신뢰성 평가방법의 정립 (Establishment of Fire Reliability Assessment Method for Structural Strength)

  • 박창규
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.54-62
    • /
    • 2017
  • 본 논문에서는 해상 구조물들의 화재시 안전성 평가에 대한 연구의 일환으로써 기본적인 구조강도 부재들의 화재시 거동 및 파괴확률을 구해 보았다. 화재에서의 안전성 평가는 부재의 Fire resistance와 화염에 의한 열하중인 Fire severity를 비교하여 이루어질 수 있다고 가정하였다. Fire severity는 육상 건축물에 대한 화재안전 규정인 Eurocode 1의 표준화염 온도변화 곡선과 부재로의 열전달 방정식을 사용하여 부재의 최대온도를 구하게 되며, Fire resistance는 단순 부재의 경우, 간략식과 코드의 활용으로 해결할 수 있지만, FPSO 와 해상 구조물의 복잡성을 고려하여 상용 구조해석 프로그램의 활용을 통하여 탄소성해석 및 대변형등을 고려한 보다 실용적인 부재의 구조강도를 해석하여 주어진 파괴모드에 대한 한계 온도를 구하여 최대온도와 비교하였다. 더불어, Fire resistance 측면에서의 두 접근방식의 비교를 통해서 두 방식의 등가적 성향을 확인하였다. 여기서 Strength, Serviceability, Stability의 세 가지 측면에서 First Hinge, Large Deflection, Buckling의 세 가지 파괴모드를 상정하고 각각에 대한 파괴여부를 확인하였고, 이렇게 구해지는 Fire severity와 Fire resistance의 식에 AFOSM 방법을 적용하여 최종적으로 부재의 파괴확률을 구하는 방식을 통해, 단순 부재인 Beam 및 Plate 예제에 적용하여 구조물의 화재시 거동 및 각 파괴모드에 대한 파괴여부를 구하였다.

과냉각수조에서 증기응축 특성에 관한 실험적 연구 (Experimental Study on Characteristics of Steam Condensation in a Sub-cooled Water Pool)

  • 김환열;조석;송철화;정문기;최상민
    • 에너지공학
    • /
    • 제8권2호
    • /
    • pp.298-308
    • /
    • 1999
  • 과냉각수조로 분사되는 증기의 직접접촉 응축특성을 알아보기 위하여 다섯 개의 수평 노즐에 대해 증기 질량유량과 수조 온도를 여러 가지로 변화시키면서 실험적 연구를 수행하였다. 증기응축현상을 육안관찰과 고속 비디오 카메라를 사용한 방법으로 분석한 결과, 안정된 증기제트인 경우 증기 질량속과 수조온도가 변화함에 따라 타원형 및 원추형 증기제트 형상이 나타나는 것을 관찰하였다. 증기제트 팽창비, 증기제트 길이 및 응축연전달계수를 구하였고, 증기 질량속, 수조온도 및 노즐 내경이 미치는 영향을 분석하였다. 증기제트 길이와 응축열전달계수를 증기 질량속 및 응축추진 포텐셜의 함수로 나타낸 상관식을 구하였다. 증기제트 내부와 주위 수조온도 분포를 구했으며 증기 질량속, 수조온도 및 노즐 내경이 미치는 영향을 분석하였다. 처깅, 천이처깅, 응축진동, 안정응축, 방울응축진동 및 간헐진동응축 등 여섯 가지 영역으로 구분된 응축 영역도를 작성하였다. 그 외, 수조 벽면에서의 동압을 측정하였고, 증기 질량속과 수조온도에 따라 변화하는 증기 응축모드와 동압과는 밀접한 연관성이 있음을 확인하였다.

  • PDF

고출력 전자 패키지 기판용 고열전도 h-BN/PVA 복합필름 (High Thermal Conductivity h-BN/PVA Composite Films for High Power Electronic Packaging Substrate)

  • 이성태;김치헌;김효태
    • 마이크로전자및패키징학회지
    • /
    • 제25권4호
    • /
    • pp.95-99
    • /
    • 2018
  • 최근 고집적 고출력 전자 패키지의 효율적인 열전달을 위한 기판 및 방열소재로서 절연성 고열전도 필름의 수요가 커지고 있어, 알루미나, 질화알루미늄, 질화보론, 탄소나노튜브 및 그래핀 등의 고열전도 필러소재를 사용한 고방열 복합소재에 대한 많은 연구가 이루어지고 있다. 그 중에서도 육방정 질화보론(h-BN) 나노시트가 절연성 고열전도 필러 소재로서 유력한 후보 물질로 선택되고 있다. 본 연구는 이 h-BN 나노시트와 PVA로 된 세라믹/폴리머 복합체 필름의 방열특성 향상에 관한 것이다. h-BN 나노시트는 h-BN 플레이크 원료 분말을 유기용매를 사용한 볼밀링과 초음파 처리에 의한 물리적 박리공정으로 만들었으며, 이를 사용한 h-BN/PVA 복합 필름을 제조한 결과 성형된 복합필름의 면방향과 두께방향 열전도도는 50 vol%의 필러함량에서 각각 $2.8W/m{\cdot}K$$10W/m{\cdot}K$의 높은 열전도도가 나타났다. 이 복합필름을 PVA의 유리전이온도 이상에서 일축 가압하여 h-BN 판상분말의 얼라인먼트를 향상시킴으로써 면방향 열전도도를 최대 $13.5W/m{\cdot}K$까지 증가시킬 수 있었다.

경험적 고유함수법에 의한 한국동해 해황변동해석 (Empirical Orthogonal Function Analysis on the Monthly Variation of Flow Pattern in the East Sea of Kore)

  • 장선덕;이종섭;서종문
    • 한국수산과학회지
    • /
    • 제21권6호
    • /
    • pp.323-330
    • /
    • 1988
  • 한국 동해 연안역의 공간적인 수온변동 특성을 밝히기 위하여 23년간 평균된 월별 평균수온 자료를 이용하여 0m 층에서 300m층 까지 각각 수층별로 E.O.F 분석을 행하고, T-S diagram과 단면별 수온분포도를 작성하여 비교, 검토하였다. 대표적인 수온의 변동양상에 따라 표층 (0m\~50m), 차층 $(100m\~150m)$ 및 중층$(200\~300m)$으로 나누었다. 수온변동량의 1st mode값에 의한 각 수층별 수온변동 양상을 요약하면 다음과 간다. 표층에서의 수온은 주로 계절적인 변동양상을 보인다. $100\~150m$ 층의 수온은 난류수와 냉수간의 상호작용과 상층으로 부터의 열의 전달작용에 의하여 주로 변동됨을 알 수 있다. $200~300m$ 층에서의 수온변동은 주로 연안 저층냉수의 이류에 의하여 지배되는 것으로 사료된다. 본 연구는 1987년도 문교부 기초과학 육성연구비의 지원에 의하여 이루어 졌다.

  • PDF

화력발전 보일러 과열기 및 재열기 운전 중 튜브 온도예측기법 (Temperature Prediction Method for Superheater and Reheater Tubes of Fossil Power Plant Boiler During Operation)

  • 김범신;송기욱;유성연
    • 대한기계학회논문집A
    • /
    • 제36권5호
    • /
    • pp.563-569
    • /
    • 2012
  • 대용량 화력발전 보일러 과열기와 재열기 튜브는 과열에 취약하여 보일러 정지 시 튜브 내부의 산화 스케일 두께를 측정하여 과열상태를 평가한다. 산화스케일 두께측정에 의한 튜브 온도예측은 튜브의 발췌가 불가피하고 정확한 과열지점의 선정과 튜브의 초기운전온도가 확보되지 못하면 유의한 튜브온도예측결과를 얻을 수 없는 문제점이 있다. 또한 해석적 방법에 의해 튜브 온도를 예측하는 경우 튜브 외부 연소가스에 대한 연소, 복사, 대류 및 난류유동에 대한 방대한 해석이 필요한 반면 순시적인 부하의 변동, 탄종의 변화 및 운전방법의 변화를 반영할 수 없으므로 지속적인 튜브의 온도를 예측할 수 없는 단점이 있다. 본 논문에서는 보일러 운전정보와 유로망 해석을 통해 튜브의 열유속을 계산하고 이를 이용하여 단시간에 튜브의 온도를 예측할 수 있는 기법을 제시하였다. 본 기법을 Larson-Miller Parameter 법과 같은 실용적인 튜브 손상평가기법과 결합하면 유용한 고온손상감시의 수단으로 활용이 가능할 것으로 판단된다.