열병합발전소 배기 덕트 시스템의 소음 진동 저감 (Noise and vibration reductions in exhaust duct system of cogeneration power plants)

  • 김원현;주원호;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.641-646
    • /
    • 2004
  • Noise and vibration was encountered in exhaust duct system which is connected with a gas turbine and a heat recovery steam generator(HRSG) of a cogeneration power plants. Especially, these problems occurred when water was added to the fuel injection to reduce NOx contents of the exhaust gas. Through the cavity mode analysis and measurements, It was concluded that these problems occurred due to the acoustic resonance between the duct cavity mode and the excitation force induced by turbulent gas flow during water injection. To reduce the noise and vibration, optimal baffle plate to change the cavity mode was installed inside of duct and noise levels of about 8 dB(A) are reduced in duct system. The effects of baffle plate and guide vane to the HRSG or inlet duct vibration were also evaluated and it was verified that there is no relation to the resonance phenomena. So, vibration of inlet duct was easily reduced by the reinforcement of structures.

  • PDF

계절별 부하 특성을 고려한 CHP 성능 해석 (Performance Analysis of CHP Condersing Season heat load Conditions)

  • 서영호;이준희;김남진;김종윤;조성갑;전용한
    • 설비공학논문집
    • /
    • 제22권7호
    • /
    • pp.454-459
    • /
    • 2010
  • This paper is a actual design case applied to make a bid for CHP plant construction in some country. The purpose of this study is to optimize the system performance for the requirement conditions written in ITB by the client. The system consists of gas turbine, steam turbine, heat recovery steam generator and heat exchangers for district heating. The performance analysis is conducted for various seasons conditions and heat load. As a result, air density and heat load is reduced in accordance with decreasing of the outdoor temperature, therefore the system power is reduced. Considering this, the design parameters to meet the requriement conditions are optimized.

복합화력 온라인 성능감시 구현을 위한 열소비율 분담 기법 (A Technique of the Combined Cycle Heat Rate Allocation for the On-Line Performance Monitoring System)

  • 주용진;김시문
    • 에너지공학
    • /
    • 제13권3호
    • /
    • pp.173-180
    • /
    • 2004
  • 본 논문에서는 복합화력 발전시스템을 대상으로 한 온라인 성능감시시스템에 적용될 수 있는 열소비율 손실 분담기법을 고안하였다. 이 기법은 현재 운전조건에 대한 기대 열소비율을 계산하여 이를 실제 열소비율과 비교하고 이들의 편차, 즉 손실분을 발전시스템 구성기기(가스터빈 배열회수보일러, 증기터빈, 복수기)로 분담시킴으로써 손실이 어디에서 얼마만큼 발생하는 지를 정량적으로 감지하여 조치할 수 있는 성능관리지표로서 활용된다.

120MW급 열병합 복합발전시스템의 열역학적 효율 특성 (The thermodynamic efficiency characteristics of combined cogeneration system of 120MW)

  • 최명진;김홍주;김병헌
    • 한국산학기술학회논문지
    • /
    • 제18권6호
    • /
    • pp.29-36
    • /
    • 2017
  • 본 논문은 열병합 복합발전이란 하나의 프로세스에서 전기 또는 기계 동력과 열에너지의 두 형태를 생산하는 것이다. 가스터빈 열병합 발전 시스템의 각 구성부의 성능을 변수로 전체 시스템의 연료 소모와 각 구성부의 열과 전기의 성능을 표현하여야 한다. 전체시스템은 상부 시스템인 가스터빈 2대와 하부시스템인 열회수 증기발생기(HRSG) 2대, 증기터빈 1대, 지역난방열교환기 2대로 구성되어 있다. 가스터빈 열병합 복합발전시스템에서 가동시간 기준 10,000시간 후 성능시험을 각종 시험장치 설치 및 ASME PTC 46에 준한 성능시험으로 실시하였고, 발전소 전체의 종합출력과 효율에 대한 성능을 분석하였다. 이러한 성능시험 실시자료를 기초로 시험성능을 비교하여 성능변화 값을 확인하였다. 이 논문에서 가스터빈, 열회수 증기발생기, 증기터빈의 열역학적 시스템 해석을 통하여 이론적 결과 값을 산출하였다. 비교 대상은 전체 시스템의 생산열량과 대기로 배출되는 열량을 이론값과 실험값을 비교하였고, 전기출력 및 열 출력에 대한 효율을 이론값과 실제 값을 비교하였다. 가스터빈 열병합 복합발전소 성능 특성에 대한 시험결과를 열역학적 효율 특성과 비교하였으며, 0.3%의 오차를 보였다.

안내덕트 내부 난류유동구조에 따른 열전달 특성변화 수치해석 (Numerical Study on Heat Transfer Characteristics of Turbulent Flow in Transition Duct)

  • 유근종;최훈기;최기림
    • 대한기계학회논문집B
    • /
    • 제35권9호
    • /
    • pp.923-932
    • /
    • 2011
  • 본 연구에서는 복합화력발전소 가스터빈 출구가스 안내덕트 내부의 가스유동장이 배열회수보일러 전열기구에 미치는 영향을 CFD기법을 이용하여 분석하였다. 안내덕트 내부 난류흐름의 경우, 유속의 편차가 크고 선회 효과 및 상승류 현상이 심한 특징을 가지고 있음으로 이와 같은 유동의 수치해석을 위해 2개 방정식 난류점성 모델 중 RNG k-${\epsilon}$ 모델을 사용하였으며 유동장의 영향을 가장 많이 받는 배열 회수보일러 최종과열기관의 열전달특성변화를 파악하기 위하여 NTU 방식을 이용한 수치해석결과와, 산업계에서 적용하는 설계기법에 의한 결과를 비교하였다.

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

외기조건변화에 따른 CHP 성능 해석 (Performance Analysis of CHP(Combined Heat and Power) for Various Ambient Conditions)

  • 전용한;김종윤;김남진;임경범;서영호;김기환
    • 한국산학기술학회논문지
    • /
    • 제12권8호
    • /
    • pp.3353-3359
    • /
    • 2011
  • 본 연구에서는 가스터빈과 증기터빈, 열회수증기 발생 장치와 지역난방 열교환기로 열병합 발전 시스템을 구성하여 복수기가 없이 증기 터빈 중압단에서 추기된 증기와 배기 증기를 지역난방 열교환기의 열원으로 사용하는 추기 배압식을 적용하였다. 구성된 시스템에 대하여 필요로 하는 열부하량과 발전 출력 조건을 만족 시키기 위한 최적 설계 성능 해석을 하였으며, 이와 함께 겨울철 외기 온도 조건의 변화에 대한 시스템의 부분부하 해석을 하였다. 해석을 위해 상용 프로그램인 Thermoflex를 사용하였다. 시스템의 해석 결과, 기준 조건에서 수요처의 요구를 만족 시키는 최적 설계를 기준으로 각 외기 온도 변화에 대한 부분부하 성능 해석의 결과를 얻을 수 있었다. 그 결과 열부하량이 고정된 상태에서, 가스터빈과 전체 시스템의 출력은 외기온도가 감소함에 따라서 증가하였지만, 열원인 배기가스의 온도 감소로 인하여 증기터빈의 출력은 이와 반대로 감소하는 경향을 나타내었다. 그러나 전체 시스템에서 가스터빈의 차지하는 비중이 크기 때문에 전체 시스템의 출력의 경향은 가스터빈과 동일한 결과를 얻을 수 있었다.

배열회수 보일러 구조물의 피로수명 평가를 위한 유동해석 (The CFD Analysis for the Fatigue Life Evaluation of HRSG Structure)

  • 김진범;김철호
    • 에너지공학
    • /
    • 제29권3호
    • /
    • pp.7-17
    • /
    • 2020
  • 배열회수보일러는 가스터빈의 고온의 배기가스 에너지를 이용하여 증기를 발생시키는데 고속의 배기 가스에 의해 유체유발진동이 발생하여 다수의 구조물 파손이 발생한다. 구조물의 파손을 예측하기 위한 피로수명 평가는 유체유발 진동으로 발생하는 진동분석을 통해 PSD(Power Spectral Density)을 도출해야 하지만, 가스터빈의 배기가스 유동 형태가 매우 빠르고 복잡하여 발생되는 진동을 이론, 실험적으로 도출되는 것은 매우 어렵다. 하지만 LES(Large Eddy Simulation) 적용을 통해 구조물의 위치에 따라 진동 특성을 파악할 수 있는 방법을 정립하였고, 이러한 진동 특성을 구조 해석에 적용하면 구조물 피로수명 평가에 활용할 수 있다.

수소스테이션용 $20Nm^3/hr$급 수소제조장치 스케일-업 및 성능시험 (Performance test of scale-up $20Nm^3/hr$ scale hydrogen generator for hydrogen station)

  • 오영삼;백영순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.37-42
    • /
    • 2006
  • In this study, $20Nm^3/hr$ scale compact hydrogen generator which can be apply to the hydrogen station was tested for hydrogen station application. $20Nm^3/hr$ scale compact hydrogen generator was developed by upgrading concept of stacking plate reactor from former $20Nm^3/hr$ scale plate hydrogen generator. concepts for improving system efficiency and performance include such as idea of heat recovery from the exhaust, exhaust duct which is especially design for plate type reactor reinforcement of insulation, enlargement of heat exchange area of reactor, introduction of desulphurizer reactor and PROX rector in a compact design, introduction of back fire protection structure of plate burner and so on, We can learn that final prototype of scale-up $20Nm^3/hr$ scale compact hydrogen generator can be operated steadily in 100% road at which over 94% of methane conversion(S/C=3.75) was obtained. In case of making up the weak point, we expect that it is possible to apply to hydrogen station by way of showing an example.

  • PDF

배열회수보일러(HRSG)의 입구유동 경계조건에 따른 유동특성 변화에 관한 연구 (A Numerical Analysis of Flow Characteristics in a Heat Recovery Steam Generator with the Change of Inlet Flow Conditions)

  • 김태권;이부윤;하지수
    • 한국가스학회지
    • /
    • 제15권3호
    • /
    • pp.53-57
    • /
    • 2011
  • 본 연구는 배열회수보일러(HRSG)에서의 유동특성을 유동수치해석을 통하여 분석하였다. HRSG 입구영역은 가스터빈 후류의 출구에 해당하고 가스터빈 후류는 강한 선회 및 난류 유동이다. 따라서 HRSG 입구 유동은 가스 터빈 출구 유동 특성이 고려되어야 한다. 본 연구에서는 HRSG 입구 유동 경계조건을 가스터빈 출구 유동 해석을 통하여 도출된 결과를 이용하였다. 가스터빈 출구 유동해석 결과를 보면 축방향 속도가 가장 크게 나타나는 곳이 원형 덕트의 벽면 측이고 난류운동에너지와 소산율이 크게 나타나는 곳이 속도 구배가 급격한 곳으로 축방향 속도가 최대가 되는 곳과 차이가 있다. 본 연구에서는 HRSG 입구영역에서의 난류 성분을 가스터빈 출구 유동을 계산 한 결과를 이용한 경우와 난류강도를 속도의 10%를 이용하고 원형 덕트의 직경을 특성 길이로 사용한 두 가지 경우에 대하여 유동해석을 통하여 유동 특성을 비교하였다. 본 연구를 통하여 HRSG 입구 유동 경계조건은 반드시 난류성분이 올바르게 적용되어야 HRSG 유동 특성 해석의 정확성을 기할 수 있음을 알았다.