• Title/Summary/Keyword: heat of hydration in concrete

Search Result 538, Processing Time 0.028 seconds

A Study on Field Applications of Hydration Heat Control in the Mass Concrete Using Oscillating Capillary Tube Heat Pipe (OCHP를 이용한 매스콘크리트 수화열 제어의 현장적용에 관한 연구)

  • Yum, Chi-Sun;Bae, Won-Mahn;Kim, Myung-Sik;Beak, Dong-Il;Kim, Kang-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.413-416
    • /
    • 2006
  • In process of the mass concrete structure, the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete, this paper reports results of hydration heat control of mass concrete using the Oscillating Capillary tube Heat Pipe(OCHP). There were the several RC box molds which shows a difference as compared with each other. One was not equipped with OCHP. The others were equipped with OCHP. All of them were cooled with natural air convection. The OCHP was composed of copper pipe with 11 turns(outer diameter : 4mm, inner diameter : 2.8mm) and heat type was non-looped type. The working fluid was R-22 and its charging ratio was 40% by volume. The core of the concrete temperature was approximately $55^{\circ}C$ in the winter without OCHP. But the concrete temperature with OCHP was reduced its difference in temperature with the outdoor temperature to $12^{\circ}C$. Finally we saw the index figure of the thermal crack of the structures were varied from 0.75 to 1.47.

  • PDF

An Experimental Study on the Properties of Ultra Low Heat Mass Concrete Containing Limestone Powder (석회석미분말을 혼입한 초저발열 매스콘크리트의 특성에 관한 연구)

  • 하재담;김동석;김태홍;이종열;권영호
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1175-1180
    • /
    • 2000
  • Recently, the crack of concrete induced by the heat of hydration of cement is a serious problem for more greater, special and higher strength of concrete structures. The increasing concrete's temperature is mainly caused by the heat of hydration of cement and so, to control the thermal stress of concrete structure is desirable to use low heater material of hydration. There are many methods to diminish the increasing of concrete temperature such as using of low heat cement, addition of fly-ash, application of pre-cooling, etc., and in this study, we evaluate the heating and mechanical properties of ultra low heat mass concrete using Low Heat Portland(KS Type IV) cement with 30% of limestone powder. The results of this study will be applied to side wall and bottom of No. 15 and 16 of underground LNG tank in Inchon.

Examination of Concrete Hydration Heat According to the Application of Synthetic Resin Formwork (합성수지 거푸집 적용에 따른 콘크리트 수화열 검토)

  • Nam, Kyung-Yong;Kim, Seong-Deok;Choi, Suk;Yang, Keun-Hyeok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.153-154
    • /
    • 2020
  • The purpose of this paper is to examine the characteristics of heat and hydration of concrete according to formwork materials. As a result of the experiment, it was found that there were no problems such as concrete heat loss and delay in hydration reaction due to the use of synthetic resin formwork.

  • PDF

Field Application of Mass Concrete Using Setting Time Difference of Super Retarding Agent for Reduction of Hydration Heat (초지연제의 응결시간차를 이용한 매스 콘크리트의 수화열 저감을 위한 현장 적용)

  • 전충근;심보길;손성운;신동안;오선교;한천구
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2004.05a
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper, field application of mass concrete using setting time difference of super retarding agent is reported to reduce hydration heat of concrete placed at newly constructed apartment house in Busan. Horizontal placing lift is applied. According to test results. slump and air content meets the requirement of target values. For compressive strength, it exceeds the nominal strength ordered by the costumer. Compressive strength of concrete cured in place is achieved more than the values of nominal strength at l4days. For temperature history, maximum temperature of center at top section shows 58.5$^{\circ}C$, and at bottom section, 62.6$^{\circ}C$. According to naked eye's investigation, no hydration heat crack is observed at the surface of concrete.

  • PDF

Hydration Heat Analysis of Mass Concrete considering Heat Transfer Coefficient and Hydration Heat Difference (수화발열량차 및 열전달계수 변화를 고려한 매스콘크리트의 수화열 해석)

  • Han, Seung-Baek;Lee, Seong-Su;Shin, Hyo-Bum;Kim, Ho-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.249-252
    • /
    • 2008
  • In recent large-scale structures, as mass concrete type structure is frequently applied to the building, temperature crack due to hydration heat needs to be considered. Since a volume change is internally or externally restricted in a mold after placing concrete, temperature crack of mass concrete takes place. By this reason, the reduction method to control this crack is required. In this study, low heat mixture and hydration heat difference is used to execute the analysis of hydration heat, considering the changes of heat transfer coefficient according to curing conditions and block placement of mass concrete. For the analytical modelling, original portland cement and concrete of low heat mixture are placed in the upper and lower payer, respectively. A convection boundary condition is fixed because mass concrete of block placement is characterized by the difference of mold form and curing condition. Through the analysis results considering the changes of low heat mixture, block placement, and heat transfer coefficient, we check out the temperature and stress distribution and analyze the temperature crack reduction effect.

  • PDF

In-Site Measurement and Analysis of Heat of Hydration for Kumdang Bridge (금당교 교대기초 수화열 계측 및 해석)

  • 안상구;이필구;차수원
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.363-368
    • /
    • 2001
  • Abutments in Kumdang bridge are massive concrete structures of which total height is l0m, length is 30m, and width is 7m. Therefore, there is every probability that early age thermal cracking such as hydration heat occur. We measure heat of hydration, strains of rebar, and stresses of concrete abutment during construction. Using analysis of measuring data, we examine thermal stresses, and make use of results as method which control thermal cracking. Finally, we develope thermal stress analysis program which have pre/post processor to be easy of accessing and the usefulness of that is estimated through comparison of results.

  • PDF

An Experimental Study on the Influence of Heat of Hydration in High Strength Concrete during Hardening Process (고강도콘크리트의 내부온도이력과 경화콘크리트의 특성에 관한 실험적 연구)

  • 윤영수;이승훈;박희민;성상래;백승준;장일영;신성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.127-132
    • /
    • 1994
  • This study attemps to investigate the influence of heat of hydration occured during hardening on the strength development of high strength concrete. The concrete design strengths of 500kg/$\textrm{cm}^2$ and 700kg/$\textrm{cm}^2$ were considered to simulated the square columns having $80\times80cm$ and $100\times100cm$, respectively. Both standard curing and field curing specimen were prepared at the specified ages, and the cores were drilled out from the structure. The thermal sensors were installed into the specimen to measure the heat of hydration process occurred during the hardening. This paper tries to uncover the relationship between the temperature history of the concrete and strength development. The correlation of core strength and specimen strength with curing condition is also discussed. Further research is desired to enlight the relationship between strength and heat of hydration of high strength concrete.

  • PDF

An Experimental Study on the Dispersion Effect of Hydration Heat in the Mass Concrete Using OCHP (OCHP를 이용한 매스콘크리트 수화열 분산효과에 관한 실험적 연구)

  • Kim, Myung-Sik;Baek, Dong-Il;Kim, Kang-Min;Yum, Chi-Sun;Bae, Won-Mahn
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05b
    • /
    • pp.437-440
    • /
    • 2006
  • In process of the mass concrete structure, the heat of hydration may cause serious thermal cracking. In order to eliminate hydration heat of mass concrete, this paper results of hydration heat control of mass concrete using the Oscillating Capillary tube Heat Pipe(OCHP). There were the several molds which shows a difference as compared with each other. One was not equipped with OCHP. Other were laid with OCHP, and the other were laid in 100cm, and exposed out 50cm. All of them were cooled with natural air convection. The OCHP was composed of copper pipe(outer diameter : 4mm, inner diameter : 2.8mm) and heat type was non-looped type. The working fluid was R-22 and its charging ratio was 40% by volume. The core of the concrete temperature was approximately $53^{\circ}C$ without OCHP. But the concrete temperature with OCHP was reduced its difference in temperature with the outdoor temperature to $12{\sim}15^{\circ}C$. Finally we saw the index figure of the thermal crack of the structures were varied from 0.6 to 1.6.

  • PDF

Properties of Hydration Heat and Autogenous Shrinkage of High-Strength Mass Concrete with Latent Heat Material (잠열재를 사용한 고강도 매스 콘크리트의 수화열 및 자기수축 특성)

  • Lee, Eui-Bae;Koo, Kyung-Mo;Nam, Jeong-Soo;Kim, Young-Sun;Kim, Young-Duck;Kim, Gyu-Yong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.315-316
    • /
    • 2009
  • In this study, latent heat material was used to reduce hydration heating velocity of high-strength mass concrete. And the properties of hydration heat and autogenous shrinkage, and the relationship between hydration heat and autogenous shrinkage of high-strength mass concrete were numerically investigated.

  • PDF

The statistical method for quantitative analysis of hydration heat and autogenous shrinkage of concrete (콘크리트 수화발열 및 자기수축 특성의 정량적 분석을 위한 통계적 방법)

  • Lee, Eui-Bae;Lee, Hyung-Jun;Koo, Kyung-Mo;Na, Chul-Sung;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.645-648
    • /
    • 2008
  • In this study, to evaluate the correlation between hydration heat and autogenous shrinkage of high strength concrete in early age, statistical method present numerically hydration heat and autogenous shrinkage was studied. First of all, hydration heating velocity and autogenous shrinking velocity as quantitative coefficients which represent the main properties of hydration heat and autogenous shrinkage were proposed. Two coefficients were calculated by statistical analysis and were equal with the regression coefficient. To verify the validity of the proposed statistical analysis method, data of hydration heat and autogenous shrinkage gathered by a real experiment were analyzed by it. In results, properties of hydration heat and autogenous shrinkage of high strength concrete in early age were analyzed quantitatively. Also evaluation and comparison of the correlation between hydration heat and autogenous shrinkage with numerical value were possible.

  • PDF