• Title/Summary/Keyword: heat map

Search Result 230, Processing Time 0.022 seconds

Ground Surface Temperature Distribution of Korea (우리나라 지표면 온도 분포)

  • Koo, Min-Ho;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.431-433
    • /
    • 2006
  • Accurate information on the ground surface temperature is essential for design of a borehole heat exchanger and thus ensuring the performance of a ground source heat pump system along with knowledge on thermal diffusivity and conductivity of ground. In this study we analyzed the shallow subsurface temperature monitoring data of 58 Korea Meteorological Administration synoptic stations. As a result, we compiled mean annual ground surface temperature distribution map using multiple regression analysis of the monitoring data.

  • PDF

Study on Evaluation of Heat Demand and GIS Mapping in Costal Area (연안도시의 열 수요 추정 및 GIS Map 작성에 관한 연구)

  • Chung, Yong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.25 no.1
    • /
    • pp.192-197
    • /
    • 2013
  • To overcome the mismatch of heat demand and heat supply is important as considering point on heat utilizing aspects in Urban area. At this point, It need to know the plan of heat networks on the heat balance aspects. The purpose of this study is to know the method of heat evaluation on heat network around costal area. It is need to building uses to calculate the amounts of heat demand. 25 different types of building uses were supplied, but it was reclassified 10 types and calculated the amounts of heat demand in the costal area. The results was described on the area with GIS mapping.

A Study on Urban Environmental Climate Mapping Method for Sustainable Urban Planning in Daegu (대구지역의 환경친화적 도시계획을 위한 도시환경기후지도 작성에 관한 연구)

  • Park, Myung-Hee;Jung, Woo-Sik;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.20 no.4
    • /
    • pp.465-482
    • /
    • 2011
  • To preserve atmospheric environment of urban areas, it needs to create urban space considering air pollution sources and natural and geographical properties such as wind circulation. According to this study could examine climate and environmental characteristics of Daegu and accordingly suggest a climate map in urban environment and an "advice map" in urban planning. The urban area(area paved with asphalt and concrete) of Daegu has increased by more than five times since 1960. In addition, the analysis of thermal environment through satellite data shows that the surface temperature between a place paved with artificial structures and a farmland shows $10{\sim}20^{\circ}C$ difference during the daytime in the summer. Regarding the parks inhibiting the heat island of a city have the small area of trees, and the road paved with concrete is wide so that they hardly serve as the source of heat absorption. As Apsan is located to the south of Daegu and Palgonsan to the north and Daegu has east high west low type, mountain wind from mountains in the south and north passes a city and delivers heat and air pollutions at night. In the west of Daegue, there is the poorest environment and industrial facilities and environmental basic facilities are mostly located, so large residential complexes that are being built around the industrial facilities as if they set up a folding screen and therefore the poor environment is increasingly worse.

Study on Estimation of Urban Anthropogenic Heat Generation (도시의 인공열 산정에 관한 연구)

  • 손은하;김유근;홍정혜
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.1
    • /
    • pp.37-47
    • /
    • 2000
  • The Urban thermal environment is influenced and modified in many ways. One modification is brought by the anthropogenic heat generation emitted from the combustion processes and the use of energy such as industrial, domestic and traffic procedure. The anthropogenic heat generation affect an the increase of urban temperature, the well-known urban heat islands. The study on the urban thermal environment needs a great deal of the statistic data about the inner-structure of urban, the contribution of different constructions and the traffic amount on urban thermal environment in finite region. In order to overtake a quantitative analysis of effect of the anthropogenic heat, a distribution map of the urban anthropogenic heat was made using hte data of the energy consumption used at the several constructions and traffic amount of vehicles in Pusan Metropolitan. Annual mean heat flux over the 4$\textrm{km}^2$ urbanized area in Pusan is 41.5W/$m^2$, ranging from 31.4W/$m^2$ in summertime to 59.5W/$m^2$ in wintertime and maximum diurnal anthropogenic heat generation is corresponding to 10% of irradiance during summertime.

  • PDF

Quality and shelf life of sliced root of Platycodon grandiflorum treated by ozon-microbubble-heat shock (오존-마이크로버블-열수 처리한 세절 도라지의 품질 및 저장성)

  • Park, Kyung Min;Lee, Ji Young;Min, So-Ra;Jeong, Moon-Cheol;Koo, Minseon
    • Food Science and Preservation
    • /
    • v.23 no.5
    • /
    • pp.605-613
    • /
    • 2016
  • The quality and shelf life of sliced root of Platycodon grandiflorum (Doraji) treated by ozon-microbubble-heat shock (OMH) were investigated by combining modified-atmosphere packaging [MAP, ($50%O_2+15%CO_2+35%N_2$)]. The study was based on microbiological (total viable bacteria, fungi, Enterobacteriaceae and coliforms numbers), physicochemical and sensory changes. OMH treatment was effective in reducing microbial populations of the sliced Doraji, especially Enterobacteriaceae and coliforms reduced by 2 log CFU/g. However OMH-MAP treatment remained the aerobe and fungi numbers. Regarding the color, OMH-MAP delayed the change of Hunter $b^*$ and the sliced Doraji by OMH-MAP treatment exhibited lower decrease of flavor and overall acceptability compared to those by polypropylene packaging after tap water treatment (Control). The OMH and $50%O_2+15%CO_2$ MAP treatment gave better sensory quality and extended shelf-life for sliced Doraji (~3 days longer shelf-life than Control). Flavor was significantly related to overall acceptability at both Control and OMH-MAP, whereas total coliforms prevalence was associated with overall acceptability at only OMH-MAP. Therefore microbubble-heat shock treatment may improve microbial safety and sliced Doraji by OMH treatment can stored under $50%O_2+15%CO_2$ treatment for up to 7 days. Thus, OMH and MAP treatment may be used in maintaining the storage quality and marketability of sliced Doraji.

Visualization Technique of Spatial Statistical Data and System Implementation (공간 통계 데이터의 시각화 기술 및 시스템 개발)

  • Baek, Ryong;Hong, Gwang-Soo;Yang, Seung-Hoon;Kim, Byung-Gyu
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.12
    • /
    • pp.849-854
    • /
    • 2013
  • In this paper, a system technology-based algorithms and visualization is proposed to show a space data. Also the proposed system provides analysis function with combination of usual map and automatic document generation function to give a useful information for making an important decision based on spatial distributed data. In the proposed method, we employ the heat map analysis to present a suitable color distribution for 2 dimensional map data. The buffering analysis method is also used to define the spatial data access. By using the proposed system, spatial information in a variety of distribution will be easy to identify. Also, if we make a use of automatic document generation function in the proposed algorithm, a lot of time and cost savings are expected to make electronic document which representation of spatial information is required.

UNIQUENESS OF IDENTIFYING THE CONVECTION TERM

  • Cheng, Jin;Gen Nakamura;Erkki Somersalo
    • Communications of the Korean Mathematical Society
    • /
    • v.16 no.3
    • /
    • pp.405-413
    • /
    • 2001
  • The inverse boundary value problem for the steady state heat equation with convection term is considered in a simply connected bounded domain with smooth boundary. Taking the Dirichlet to Neumann map which maps the temperature on the boundary to the that flux on the boundary as an observation data, the global uniqueness for identifying the convection term from the Dirichlet to Neumann map is proved.

  • PDF

The Implementation of Tubesheet Map Automatic Function for Nuclear Power Plant Heat Exchanger (원전 열교환기 Tubesheet Map 자동 Drawing 기능 구현)

  • Song, Jae-Ju;Shin, Jin-Ho;Yi, Bong-Jae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2001.04b
    • /
    • pp.751-754
    • /
    • 2001
  • 열교환기(Heat Exchanger)는 원전 운영에 핵심적인 설비이다. 따라서 열교환기 전열관의 건전성 유무를 판단키 위해 정기적으로 비파괴검사의 일종인 와전류검사(ECT, Eddy Current Testing)를 수행하고 있다. 이러한 와전류검사 공정은 크게 3가지로 분류할 수 있다. 첫 번째는 전열관 상태검사를 위한 신호데이터 취득공정이고, 두 번째는 취득된 신호를 판독하여 전열관의 건전성 여부를 진단하는 평가공정, 마지막으로 평가공정에서 발생하는 방대한 데이터를 토대로 추이분석 자료를 제공할 수 있는 공정이 필요하다. 본 논문에서는 세 번째 공정에서 필요한 열교환기 Tubesheet를 사용자 정의에 따라 자동으로 구현할 수 있는 기능을 정의하고, 평가공정에서 발생한 데이터를 직접 Tubesheet상에 Mapping 처리하여 시각적으로 전열관 상태를 확인할 수 있는 프로그램 구현방법을 제시한다.

  • PDF

Moving Data Pictures (움직이는 데이터 그림)

  • Huh, Myung-Hoe
    • The Korean Journal of Applied Statistics
    • /
    • v.26 no.6
    • /
    • pp.999-1007
    • /
    • 2013
  • This research shows several types of moving pictures from the data: 1) the word cloud of Korean texts, 2) the heat map of n ${\times}$ p matrices, 3) the moving image of p ${\times}$ p scatterplot matrix, 4) the local projective display of k clusters (Huh and Lee, 2012). Moving pictures may reveal the hidden information and beauty of the datasets and ignite the curiosity of information consumers. Video files are attached.