• 제목/요약/키워드: heat loss reduction

검색결과 184건 처리시간 0.031초

CNG 직접분사식 연소기에서의 연소 라디칼 특성 (Characteristics of Combustion Radical in CNG Direct Injection Vessel)

  • 최승환;조승완;이석영;정동수;전충환;장영준
    • 한국자동차공학회논문집
    • /
    • 제12권5호
    • /
    • pp.58-65
    • /
    • 2004
  • A cylindrical constant volume combustion chamber was used to investigate the combustion characteristics of stratified methane-air mixture under several initial charge conditions in the author's previous reports. The results showed that the improvement of thermal efficiency and reduction of heat loss was realized simultaneously by using 2-stage injection method. This paper deals with the reason why the stratified combustion has showed better combustion rate through the measurement and analysis of chemiluminescence of C $H^{*}$ and $C_{2}$$^{*}$ radicals. An optic fiber bundle is used to measure the local emission of C $H^{*}$ and $C_{2}$$^{*}$ radicals to map the relationship between the excess air ratio and local radical intensity ratio in the combustion vessel at 5 mm apart form the geometric center. The results show that there exist a relationship between the intensity ratio and the air-fuel ratio. It is revealed that the improvement of combustion rate in a lean-stratified mixture is realized through the 2-stage injection method. method.

Thermo-economic approach for absorption air condition onboard high-speed crafts

  • Seddiek, Ibrahim S.;Mosleh, Mosaad;Banawan, Adel A.
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제4권4호
    • /
    • pp.460-476
    • /
    • 2012
  • High-speed crafts suffer from losing a huge amount of their machinery energy in the form of heat loss with the exhaust gases. This will surely increase the annual operating cost of this type of ships and an adverse effect on the environment. This paper introduces a suggestion that may contribute to overcoming such problems. It presents the possibility of reusing the energy lost by the ships' exhaust gases as heating source for an absorption air condition unit onboard high-speed crafts. As a numerical example; the proposed method was investigated at a high-speed craft operating in Red Sea between Egypt and the Kingdom of Saudi Arabia. The results obtained are very satisfactory. It showed the possibility of providing the required ship's air condition cooling load during sailing and in port. Economically, this will reduce the annual ship's operating cost. Moreover, it will achieve a valuable reduction of ship's emissions.

PRAM에서 $Ge_1Se_1Te_2$와 전극의 접촉 면적을 줄이는 방법에 대한 효과 (Reduced contact size in $Ge_1Se_1Te_2$ for phase change random access memory)

  • 임동규;김재훈;나민석;최혁;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.154-155
    • /
    • 2007
  • PRAM(Phase-Change RAM) is a promising memory that can solve the problem of conventional memory and has the nearly ideal memory characteristics. We reviewed the issues for high density PRAM integration. Writing current reduction is the most urgent problem for high density PRAM realization. So, we studied new constitution of $Ge_1Se_1Te_2$ chalcogenide material and presented the method of reducing the contact size between $Ge_1Se_1Te_2$ and electrode. A small-contact-area electrode is used primarily to supply current into and minimize heat loss from the chalcogenide. In this letter, we expect the method of reducing the contact size between $Ge_1Se_1Te_2$ and electrode to decrease writing current.

  • PDF

Performance of Adhesives in Glulam after Short Term Fire Exposure

  • Quiquero, Hailey;Chorlton, Bronwyn;Gales, John
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.299-311
    • /
    • 2018
  • As engineered timber such as Glulam is seeing increasing use in tall timber buildings, building codes are adapting to allow for this. In order for this material to be used confidently and safely in one of these applications, there is a need to understand the effects that fire can have on an engineered timber structural member. The post-fire resilience aspect of glulam is studied herein. Two sets of experiments are performed to consider the validity of zero strength guidance with respect to short duration fire exposure on thin glulam members. Small scale samples were heated in a cone calorimeter to different fire severities. These samples illustrated significant strength loss but high variability despite controlled quantification of char layers. Large scale samples were heated locally using a controlled fuel fire in shear and moment locations along the length of the beam respectively. Additionally, reduced cross section samples were created by mechanically carving a way an area of cross section equal to the area lost to char on the heated beams. All of the samples were then loaded to failure in four-point (laterally restrained) bending tests. The beams that have been burnt in the shear region were observed as having a reduction in strength of up to 34.5% from the control beams. These test samples displayed relatively little variability, apart from beams that displayed material defects. The suite of testing indicated that zero strength guidance may be under conservative and may require increasing from 7 mm up to as much as 23 mm.

합성가스 스파크점화 과급 엔진에서 희박 연소를 통한 열효율 및 배기 개선 (Improvement of Thermal Efficiency and Emission by Lean Combustion in a Boosted Spark-Ignition Engine Fueled with Syngas)

  • 박현욱;이준순;나랑후 잠스랑;오승묵;김창업;이용규;강건용
    • 한국분무공학회지
    • /
    • 제26권1호
    • /
    • pp.40-48
    • /
    • 2021
  • Lean combustion was applied to improve the thermal efficiency and emission in a single-cylinder, spark-ignition engine fueled with syngas. Under naturally aspirated conditions, the lean combustion significantly improved the thermal efficiency compared to the stoichiometric combustion, mainly due to the reduction in heat transfer loss. Intake air boost was applied to compensate the low power output of the lean combustion. The gross indicated power of 24.8 kW was achieved by increasing the intake pressure up to 1.6 bar at excess air ratio of 2.2. The nitrogen oxides showed near zero level, but the carbon monoxide emission was significant.

The influence of the water ingression and melt eruption model on the MELCOR code prediction of molten corium-concrete interaction in the APR-1400 reactor cavity

  • Amidu, Muritala A.;Addad, Yacine
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1508-1515
    • /
    • 2022
  • In the present study, the cavity module of the MELCOR code is used for the simulation of molten corium concrete interaction (MCCI) during the late phase of postulated large break loss of coolant (LB-LOCA) accident in the APR1400 reactor design. Using the molten corium composition data from previous MELCOR Simulation of APR1400 under LB-LOCA accident, the ex-vessel phases of the accident sequences with long-term MCCI are recalculated with stand-alone cavity package of the MELCOR code to investigate the impact of water ingression and melt eruption models which were hitherto absent in MELCOR code. Significant changes in the MCCI behaviors in terms of the heat transfer rates, amount of gases released, and maximum cavity ablation depths are observed and reported in this study. Most especially, the incorporation of these models in the new release of MELCOR code has led to the reduction of the maximum ablation depth in radial and axial directions by ~38% and ~32%, respectively. These impacts are substantial enough to change the conclusions earlier reached by researchers who had used the older versions of the MELCOR code for their studies. and it could also impact the estimated cost of the severe accident mitigation system in the APR1400 reactor.

건물의 침기부하 절감을 위한 에너지셔터에 관한 연구 (A Study on Energy Shutters to Reduce Infiltration Load of Buildings)

  • 고광수;박윤철
    • 한국지열·수열에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.1-7
    • /
    • 2023
  • In this study, in order to reduce the amount of infiltration generated from windows among the heat loss generated in the building, energy shutters were installed on the windows to conduct experiments on the change in internal temperature and amount of infiltration due to the pressure difference between the environmental chamber and the pressure box. As a result of the experiment, when the pressure difference was 0Pa, the initial temperature of the pressure box of window was higher than that of the pressure box of the energy shutter, but when the pressure difference occurred, the internal temperature of the pressure box of the energy shutter was higher. In addition, the amount of infiltration of the energy shutter was lower than that of the windows in all experimental conditions, and it was concluded that the reduction rate of the infiltration load (of the energy shutters) could be reduced by 53.3% compared to that of the windows.

원자로 정지 동안의 위해도 모델 개발 (Risk Model Development for PWR During Shutdown)

  • Yoon, Won-Hyo;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • 제21권1호
    • /
    • pp.1-11
    • /
    • 1989
  • 원자로 정지동안에도, 잔열제거계통은 그 기능이 계속 유지되어야 하나, 실제로 가압 경수로에서 냉각상실고가 많이 발생되어 있다. 본 논문은 원자로 정지중의 냉각기능상실을 예방하고, 또한 냉각기능상실로 인한 노심손상의 중대성을 완화시키기 위한 대책을 강구하기 위한 시도로서, 전형적인 가압경수로에 대한 사고/고장 수목과 운전원실수 확률을 위한 HCR 모델, 초기 사상의 빈도를 위한 2단계 bayesian 방법 및 고장난 계통의 회복 활률을 위한 계단함수 모델 등을 이용한 원자로 정지 위해도 모델을 개발하여, 잔열제거계통의 신뢰도를 분석하였다. 그 결과는 원자로가 정지 중일 때의 위해도가 운전중일 때 이것에 비해 별로 낮지 않은 것으로 나타났으며, 몇 가지의 설계개선을 통하여 냉각기능상실로 인한 노심 손상확률을 상당히 낮출 수 있는 것으로 나타났다.

  • PDF

Airtightness of Light-Frame Wood Houses built in Daejeon and Chungnam Area

  • Jang, Sang-sik;Ha, Been
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권2호
    • /
    • pp.147-158
    • /
    • 2017
  • Among the energy consumption in building, the heating energy takes the largest part. Therefore, it is important to minimize the heat energy loss in building for the reduction of overall energy use in construction. The most important points for the minimization of energy loss in building are insulation and airtightness. Especially, in wood houses, airtightness is very important for energy saving as well as increase of durability. However, the researches on airtightness of wood buildings have been started recently and are very deficient especially in Korea. In this study, air leakage properties and airtightness performance were evaluated for light-frame wood houses built in Daejeon and Chungnam area. Total 7 houses were evaluated, among which four houses (Case 1 to Case 4) were in the construction stage before interior finish and the other three houses (Case 5 to Case 7) were after completion of construction work. The tests for airtightness were conducted by pressurization-depressurization method, and the factors included in the measurements includes air leakage rate at 50 Pa (CMH50), air change rate at 50 Pa (ACH50), equivalent leakage area (EqLA) and EqLA per floor area. As a result of this study, key air leakage points in wood houses were found to be the gaps between floor and wall, the holes for wiring and plumbing, the double glasses windows and the entrance doors. The average value of ACH50 for the houses after completion of construction work was $3.5h^{-1}$ that was similar to Europe standard ($3.0h^{-1}$). ACH50 was proportional to EqLA per floor area but inversely proportional to the internal volume, the net floor area and the area of window.

Effect of physicochemical properties and feed mix ratios on the carbothermic reductions of iron ore with coke

  • S.R.R. Munusamy;S. Manogaran;F. Abdullah;N.A.M. Ya'akob;K. Narayanan
    • Advances in materials Research
    • /
    • 제13권3호
    • /
    • pp.161-171
    • /
    • 2024
  • This study aimed to investigate the effect of physicochemical properties and mix ratios of iron ore (oxide feed): coke (reductant) on the carbothermic reductions of iron ore. Coke size was fixed at ≤63 ㎛ while iron ore size varied between 150-63 ㎛ and ≤63 ㎛ respectively. Mix ratios were changed from 100:0 (reference) to 80:20 and 60:40 while the temperature, heating rate and soaking duration in muffle furnace were fixed at 1100 ℃, 10 ℃/min and 1 hour. Particle size analyzer, XRF, CHNS and XRD analyses were used for determination of raw feed characteristics. The occurrence of phase transformations from various forms of iron oxides to iron during the carbothermal reductions were identified through XRD profiles and supported with weight loss (%). XRF analysis proved that iron ore is of high grade with 93.4% of Fe2O3 content. Other oxides present in minor amounts are 2% Al2O3 and 1.8% SiO2 with negligible amounts of other compounds such as MnO, K2O and CuO. Composite pellet with finer size iron particles (≤63 ㎛) and higher carbon content of 60:40 exhibited 45.13% weight lost compared to 32.30% and 3.88% respectively for 80:20 and 100:0 ratios. It is evident that reduction reactions can only occur with the presence of coke, the carbon supply. The small weight loss of 3.88% at 100:0 ratio occurs due to the removal of moisture and volatiles and oxidations of iron ore. Higher carbon supply at 60:40 leads into better heat and mass transfer and diffusivity during carbothermic reductions. Overall, finer particle size and higher carbon supply improves reactivity and gas-solid interactions resulting in increased reductions and phase transformations.