• 제목/요약/키워드: heat gain model

검색결과 47건 처리시간 0.04초

Modeling and validation of a parabolic solar collector with a heat pipe absorber

  • Ismail, Kamal A.R.;Zanardi, Mauricio A.;Lino, Fatima A.M.
    • Advances in Energy Research
    • /
    • 제4권4호
    • /
    • pp.299-323
    • /
    • 2016
  • Cylindrical parabolic solar concentrators of small concentration ratio are attractive options for working temperatures around $120^{\circ}C$. The heat gained can be utilized in many applications such as air conditioning, space heating, heating water and many others. These collectors can be easily manufactured and do not need to track the sun continuously. Using a heat pipe as a solar absorber makes the system more compact and easy to install. This study is devoted to modeling a system of cylindrical parabolic solar concentrators of small concentration ratio (around 5) fitted with a heat pipe absorber with a porous wick. The heat pipe is surrounded by evacuated glass tube to reduce thermal losses from the heat pipe. The liquid and vapor flow equations, energy equation, the internal and external boundary conditions were taken into consideration. The system of equations was solved and the numerical results were validated against available experimental and numerical results. The validated heat pipe model was inserted in an evacuated transparent glass tube as the absorber of the cylindrical parabolic collector. A calculation procedure was developed for the system, a computer program was developed and tested and numerical simulations were realized for the whole system. An experimental solar collector of small concentration, fitted with evacuated tube heat pipe absorber was constructed and instrumented. Experiments were realized with the concentrator axis along the E-W direction. Results of the instantaneous efficiency and heat gain were compared with numerical simulations realized under the same conditions and reasonably good agreement was found.

화염 전달함수 및 DMD 기법을 이용한 모형 가스터빈의 연소불안정성 평가 (Evaluation of Combustion Instability in a Model Gas Turbine Adopting Flame Transfer Function and Dynamic Mode Decomposition)

  • 손진우;손채훈;윤지수;윤영빈
    • 한국연소학회지
    • /
    • 제22권2호
    • /
    • pp.1-8
    • /
    • 2017
  • To evaluate the combustion instability of a gas turbine combustor, the DMD technique was applied. The mode frequency results for each fuel composition were compared with FFT(Fast Fourier Transform) results. The damping coefficient, which is a quantitative parameter for combustion instability, was evaluated for 5 experimental cases. The flame transfer function (FTF) was calculated in the most unstable test case. In deriving the FTF, gain and phase were calculated using DMD technique. As a result of the analysis of the OH radical perturbation of the DMD, the heat release fluctuation was the highest at 100 Hz, at which the highest value of gain is observed. The frequency of FFT and FTF were different. In order to clarify the reason for this, FTF for various resonance frequencies was performed and it shows that the pattern of gain was similar to FFT.

게인 스케줄링을 이용한 광대역 온도제어기의 설계 (Design of Temperature based Gain Scheduled Controller for Wide Temperature Variation)

  • 정재현;김정한
    • 한국정밀공학회지
    • /
    • 제30권8호
    • /
    • pp.831-838
    • /
    • 2013
  • This paper focused on the design of an efficient temperature controller for a plant with a wide range of operating temperatures. The greater the temperature difference a plant has, the larger the nonlinearity it is exposed to in terms of heat transfer. For this reason, we divided the temperature range into five sections, and each was modeled using ARMAX(auto regressive moving average exogenous). The movement of the dominant poles of the sliced system was analyzed and, based on the variation in the system parameters with temperature, optimal control parameters were obtained through simulation and experiments. From the configurations for each section of the temperature range, a temperature-based gain-scheduled controller (TBGSC) was designed for parameter variation of the plant. Experiments showed that the TBGSC resulted in improved performance compared with an existing proportional integral derivative (PID) controller.

디지털중계기의 부하경감 및 이득조정기능 분석을 통한 열진공시험결과 성능분석 (Study on Thermal Vacuum Test Result of DCAMP by the Analysis of Derating & Gain Control)

  • 진병일;고현석
    • 한국항공우주학회지
    • /
    • 제43권1호
    • /
    • pp.72-78
    • /
    • 2015
  • 오늘날 위성은 통신, 기상, 해양탐사, 광학, 레이다등 민수분야에서 군사분야까지 폭넓게 적용되어 그 유용성이 점점 더 증가되고 있다. 또한, 부품기술의 발달로 위성 전장품의 기능도 더욱 능동적인 형태로 진화되고 있다. 위성선진국에서는 통신위성의 중계기 효율을 증가시키고, 간섭신호를 제거하여 가입자 서비스 품질을 유지하기 위해서 디지털중계기를 탑재하고 있다. 디지털중계기는 다양한 기능구현을 위해 신호처리용 부품들을 다수 사용한다. 따라서, 기존의 수동형 중계기에 비해 많은 전력을 소모하여 더 높은 발열 상태를 유지한다. 본 논문에서는 우주인증모델(EQM)급으로 자체 제작된 디지털중계기 열진공 시험결과의 성능을 분석한다. 열진공시험과정중 디지털중계기의 기능검증을 위해 디지털 이득조정 시험결과를 제시한다. 또한, 열진공 시험결과를 근거로 주요부품의 부하경감(Derating)을 분석하여 디지털중계기 설계의 적절성을 논의한다.

희박 예혼합 연소기에서 연료 조성이 화염전달함수 특성에 미치는 영향 (Effects of Fuel Composition on Flame Transfer Function in Lean Premixed Combustor)

  • 김진아;김지환;이정원;김대식
    • 한국분무공학회지
    • /
    • 제20권3호
    • /
    • pp.135-140
    • /
    • 2015
  • Flame transfer function is used to determine the relationship between flow fluctuations and heat release perturbations in a lean premixed gas turbine combustor. The characteristics of flame transfer function are known to depend greatly on flame geometries in addition to other various flow conditions. However, it is not easy to experimentally measure the flame transfer function under various actual combustor operating conditions in terms of time and cost. The current research tries to model the flame transfer function using CFD(Computational Fluid Dynamics). From the results, it is shown that the calculated steady flame geometry can be exactly captured with consideration of the wall heat transfer and radiations. Also, unsteady analysis results show the close characteristics of the flame transfer function to the measured one in both gain and phase.

저항 점 용접공정의 최적제어 (Optimal control of resistance spot welding process)

  • 장희석;조형석
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.370-373
    • /
    • 1988
  • Althouah there have been many attempts to control weld quality in resistance spot welding processes, design method for an on-line feedback controller based upon process dynamics has not been suggested. This is due to the fact that the resistance spot welding is a highly complicated process, whice involves the interaction of electrical, thermal, mechanical and metallurgical phenomena. In this paper, an optimal control method based on FDM model with shunt effect is presented, which can regulate the nugget size, at the same time minimizing the control heat input. Optimal PI gain of the controller were determined by numerical optimization. Simulation results show that, as a result of the proposed optimal control, the weld nugget can be made to approach a desired nugget size with less control heat input than that required for the conventional spot welding process in the face of the shunt effect.

  • PDF

간이 에너지 계산법과 동적 열부하 계산법의 비교 연구 (A Comparison of the ASHRAE Simplified Energy Analysis Procedure with the HASP/ACLD Results)

  • 김두천;최진희;원영수
    • 설비공학논문집
    • /
    • 제1권3호
    • /
    • pp.210-218
    • /
    • 1989
  • The ASHRAE Simplified Energy Analysis Procedure using the Modified Bin Method(SEAP) is compared with the hourly calculation program, HASP/ACLD. The HASP/ACLD model office building with VAV system in Seoul is used as the basis for comparison. And the parameters considered are glass to wall area ratio and internal heat gains. The results show that SEAP predictions of annual energy use agree with HASP/ACLD predictions within 5% deviation. But there is a large difference in cooling and heating energy as glass to wall area ratio is varied. The SEAP cooling energy is 65-85% and the heating energy is 104-160% of the HASP/ACLD results. This is probably due to the solar heat gain data. the data related to the SEAP must be developed prior to use it.

  • PDF

건물 적용을 위한 태양열 집열기 기능을 갖는 BIPV 시스템의 기초적 연구 (A Fundamental Study of BIPV System Functioned as Solar Collector for Building Application)

  • 민성혜;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2007
  • Perimeter zone is one of the weakest area in buildings and it makes an increase of heating and cooling loads, in addition to condensation or discomfort with cold-draft to residents in winter. Because of this, it needs to be reinforced by active systems. However, they use fossil fuel, and ultimately greenhouse effect is urged. Thus, we proposed BIPV system functioned as solar collector which can substitute active system. As an fundamental stage, heat balance equation in steady-state by Fortran was used not only, in winter for pre-heating effect and electric power capacity during the day, but also in summer, for the latter during the day and sky radiation effect during the night. Especially, we should have considered shading on PV by IES Suncast, since even a little bit of it makes the efficiency too low for the PV modules to work. As a result, in summer day, the PV panel should be tiled in 70 degrees to gain the most electric power. Moreover, we could verify that this model makes higher temperature and heat flux under 0.02 m/s. On the other hand, the PV had the high efficiency with high velocity because of cooling effect behind the PV. Therefore, we should regard the air current distribution later on.

Heat-Killed Lactiplantibacillus plantarum LRCC5314 Mitigates the Effects of Stress-Related Type 2 Diabetes in Mice via Gut Microbiome Modulation

  • Nam, YoHan;Yoon, Seokmin;Baek, Jihye;Kim, Jong-Hwa;Park, Miri;Hwang, KwangWoo;Kim, Wonyong
    • Journal of Microbiology and Biotechnology
    • /
    • 제32권3호
    • /
    • pp.324-332
    • /
    • 2022
  • The incidence of stress-related type 2 diabetes (stress-T2D), which is aggravated by physiological stress, is increasing annually. The effects of Lactobacillus, a key component of probiotics, have been widely studied in diabetes; however, studies on the effects of postbiotics are still limited. Here, we aimed to examine the mechanism through which heat-killed Lactiplantibacillus plantarum LRCC5314 (HK-LRCC5314) alleviates stress-T2D in a cold-induced stress-T2D C57BL/6 mouse model. HK-LRCC5314 markedly decreased body weight gain, adipose tissue (neck, subcutaneous, and epididymal) weight, and fasting glucose levels. In the adipose tissue, mRNA expression levels of stress-T2D associated factors (NPY, Y2R, GLUT4, adiponectin, and leptin) and pro-inflammatory factors (TNF-α, IL-6, and CCL-2) were also altered. Furthermore, HK-LRCC5314 increased the abundance of Barnesiella, Alistipes, and butyrate-producing bacteria, including Akkermansia, in feces and decreased the abundance of Ruminococcus, Dorea, and Clostridium. Thus, these findings suggest that HK-LRCC5314 exerts protective effects against stress-T2D via gut microbiome modulation, suggesting its potential as a supplement for managing stress-T2D.

하절기 자돈 고온 스트레스 평가를 위한 THI 지수 모의 (Estimation of THI Index to Evaluate Thermal Stress of Piglets in Summer Season)

  • 하태환;권경석;이인복;김락우;여욱현;이상연;최희철;김종복;이준엽;전중환;우샘이;양가영
    • 한국농공학회논문집
    • /
    • 제60권4호
    • /
    • pp.113-122
    • /
    • 2018
  • Thermal stress of pigs causes decreased feed consumption and weight gain rate, immunosuppression, reproductive disorders, and increased mortality. The concept of the temperature-humidity index (THI) has been widely used to evaluate the degree of thermal stress of pigs. However, use of this concept is strongly restricted for animals living in the enclosed facilities. In this study, Building Energy Simulation (BES) technique was used to realize the energy flow among outside weather conditions, building materials, and animals. Especially, mechanisms of sensible and latent heat generation from pigs according to surrounding air temperature and their weight were designed to accurately evaluate the THI values inside the pig house. The THI values computed by the BES model were compared to those calculated by method of the report (NIAS, 2016), the model of this study predicted the start date of heat stress about 9~76 days earlier compared to the NIAS model. Results of the BES model also showed higher frequencies of the THI above the THI threshold for pigs, indicating that conventional model has a possibility of underestimating the degree of heat stress of pigs.