• Title/Summary/Keyword: heat equivalent

Search Result 416, Processing Time 0.023 seconds

Heat Transfer of Condensation by the Injecting Steam Flow In Tube (관내연기 분무류의 응축열전달)

  • 김시영
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.20 no.2
    • /
    • pp.137-142
    • /
    • 1984
  • An experimental study has been performed on the heat transfer characteristics of condensation by the injecting steam flow in the tube. The comparison between results of experimental data and available data concerning equivalent Reynolds number has studied. As the result, the followings were obtained. 1. The shear stress of the radial direction in the tube when the injecting steam flow was condensed can be written as root($\tau$sub(0)/$\tau$sub(0v))=1+1.46X sub(tt) super(0.20). 2. The effect of the heat transfer in the injecting steam flow was less than the value of equivalent Reynolds number. The reason are the nonuniform fluid film of the axial and radial direction in the tube. 3. The value of N sub(u) by the heat transfer of condensation can be written as N sub(u)=1.08$\times$[{$\rho$ sub(l) d/$\mu$ sub(l)}/{$\delta$+(2.5/P sub(rl)) ln(y sub(i)/$\delta$)}]$\times${$\tau$ sub(0)/ $\rho$ sub(l)} super(1/2).

  • PDF

Parametric Effects of Ambient Conditions on Thermal Safety of Wolsong (CANDU) Unit 1 Spent Fuel Dry Storage Canister (월성1호기 사용후 핵연료 건식저장 캐니스터의 열적 안전성에 미치는 대기 조건 인자의 영향)

  • Park, Jong-Woon;Chun, Moon-Hyun;Shon, Soon-Hwan;Song, Myung-Jae
    • Nuclear Engineering and Technology
    • /
    • v.25 no.1
    • /
    • pp.166-177
    • /
    • 1993
  • A simplified thermal analysis method to evaluate the maximum temperature of the CANDU 37-element fuel bundle within a fuel basket in a given spent fuel dry storage canister has been presented along with the results of sample analyses performed to examine the parametric effects of the ambient conditions on the maximum fuel temperature within a canister. To solve the multi-dimensional heat transfer problem of the complex geometry of rod bundles within a canister where three modes of heat transfer are superimposed, the CANDU spent fuel bundles stored in the dry storage canister are first replaced by equivalent concentric fuel cylinders. The simplified axi-symmetric two-dimensional multi-mode heat transfer problem of the equivalent fuel cylinders is then analyzed with an existing computer code, HEATING5, using additional input data and heat transfer correlations. A comparison between the predicted temperature profile and the mock-up test results shows that the agreement is quite satisfactory.

  • PDF

Effects of an Extreme Heat Adaptation Program in Hypertensive Patients (고혈압환자의 폭염 적응력 증진을 위한 프로그램 효과)

  • Jeong, Seong Hee;Kim, Nam Soon;Chae, Sumi;Lee, Eun Ju
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.3
    • /
    • pp.164-172
    • /
    • 2014
  • Purpose: The purpose of this study was to identify the effects of an extreme heat Adaptation Program on the blood pressure, stress response, self-efficacy, and knowledge of management of hypertension and extreme heat of patients who suffered from hypertension. Methods: A quasi-experimental study with a non-equivalent control group pretest-posttest design was used. The data collection period was between July 2 and August 20, 2012. Thirty-seven patients participated in the study (18 in the experimental group and 19 in the control group). Data were analyzed using $X^2$-test, t-test, and Cronbach's alpha coefficients with SPSS/WIN 19.0. Results: Patients who participated in the program showed statistically significant improvements in systolic blood pressure (SBP), self-efficacy, and knowledge of management of hypertension and extreme heat. Conclusion: The results indicate that this extreme heat adaptation program can be utilized for patients suffering from hypertension in order to reduce their SBP and to increase self-efficacy and knowledge of management of hypertension and extreme heat. Therefore, it is recommended that this program be used for elderly patients suffering from chronic disease.

Performance of Evaporation Heat Transfer Enhancement and Pressure Drop for Liquid Nitrogen (액체질소에 대한 증발 열전달 촉진 및 압력강하 성능)

  • Nam, Sang-Chul;Lee, Sang-Chun;Park, Byung-Duck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.3
    • /
    • pp.363-372
    • /
    • 2000
  • An experiment was carried out to evaluate the heat transfer enhancement and the pressure drop characteristics for liquid nitrogen using wire-coil-insert technique under horizontal two-phase conditions. The tube inner diameters were 8 mm and 15 mm, respectively and the tube length was 4.7 m. The helix angle of the wire coil insert was $50^{\circ}$ and its length was 4.7 m. Heat transfer coefficients for both the plain and the enhanced test tubes were calculated from the measurements of temperatures, flow rates and pressure drops. A correlation in a power-law relationship of the Nusselt number, Reynolds number and Prandtl number for the heat transfer was proposed which can be available for design of cryogenic heat exchangers. The correlation showed that heat transfer coefficients for the wire-coil inserts were much higher than those for plain tubes, increased by more than $1.8{\sim}2.0$ times depending upon the range of the equivalent Reynolds number. The correlation was compared with other various correlations in the turbulent flow conditions.

An experimental study of heat transfer with $Na_4P_2O_7{\cdot}10H_2O$ as P.C.M. ($Na_4P_2O_7{\cdot}10H_2O$의 축열방열시 열전달 특성에 관한 실험적 연구)

  • Lee, C.M.;Yim, C.S.
    • Solar Energy
    • /
    • v.9 no.1
    • /
    • pp.70-77
    • /
    • 1989
  • Sodium pyrophosphate that melting point is $79-80^{\circ}C$ have been Studied on heat storage and heat discharge. In heat storage process, sodium pyrophosphate was kept up initial temperature $50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$ which melt by heated water at temperature $85^{\circ}C,\;90^{\circ}C,\;95^{\circ}C$. In heat discharge process, initial temperature of sodium pyrophosphate was maintained at temperature $85^{\circ}C,\;90^{\circ}C,\;95^{\circ}C$ which varied cooling temperature $50^{\circ}C,\;60^{\circ}C,\;70^{\circ}C$. The experiment has been reached conclusions as follows. 1) Heat transfer properties of phase change material is controlled by conduction during heating and cooling process. 2) The temperature increased rapidly at initial stage and transient region increase slowly because of characteristic of latent heat. 3) The lower cooling water temperature is the less the time that get to thermal equivalent state take during discharge process. 4) The higher cooling water temperature is the less temperature difference between top and bottom in P.C.M during discharge process.

  • PDF

Development of Design-Program of Fixed Type Tube-Sheet for Heat Exchanger (열교환기용 고정형 튜브시트의 설계프로그램 개발)

  • Kong J.S.;Lee K.J.;Han J.Y.;Cho J.R.;Bae W.B.
    • Transactions of Materials Processing
    • /
    • v.15 no.3 s.84
    • /
    • pp.206-212
    • /
    • 2006
  • Design programs of tube-sheet for heat exchanger based on the related engineering society codes have been widely used. But it is not easy fer beginners to use the design programs. So we need to develop an easy program for design of tube-sheet for heat exchanger. This paper describes a developed design-program of tube-sheet fur heat exchanger. The developed program was coded on boiler theory and pressure vessel codes, provided by TEMA(Tubular Exchanger Manufactures Association) and ASME(American Society of Mechanical Engineers). Visual Basic, which is convenient for beginners to deal with, was used in the programming. Also a finite element analysis of tube-sheet for heat exchanger was carried to verify this developed program by using a commercial software, ANSYS. In the finite element analysis, tube and tube-sheet of heat exchanger were substituted by solid plate having equivalent properties for convenience of calculation. The thickness of tube-sheet obtained by the developed design-program was in good agreement with that of tube-sheet by FEA.

Thermal cracking analysis of concrete with cement hydration model and equivalent age method

  • Tian, Ye;Jin, Xianyu;Jin, Nanguo
    • Computers and Concrete
    • /
    • v.11 no.4
    • /
    • pp.271-289
    • /
    • 2013
  • In this research, a developed microstructural model of cement particles was presented to describe the cement hydration procedure. To simplify the hydration process, the whole hydration was analyzed in a series of sub-steps. In each step, the hydration degree, as well as the microstructural size of the hydration cell, was calculated as a function of the radius of the unreacted cement particles. With the consideration of the water consumption and the reduction of the interfacial area between water and hydration products, the micro-level expressions of the cement hydration kinetics were established. Then the heat released and temperature history of the concrete was carried out with the hydration degree obtained from each sub-steps. The equivalent age method based on the Arrhenius law was introduced in this research. Based on the equivalent age method, a maturity model was applied to describe the evolution of the mechanical properties of the material during the hydration process. The finite element program ANSYS was used to analyze the temperature field in concrete structures. Then thermal stress field was calculated using the elasticity modulus obtained from code formulate. And the risk of thermal cracking was estimated by the comparison of thermal stress and concrete tensile strength.

Design and Performance Evaluation of Integral-type Hot BoP for Recovering High-temperature Exhaust Gas in 2 kW Class SOFC (2 kW급 고체산화물연료전지의 고온배기가스 폐열회수를 위한 일체형 Hot BoP의 설계 및 성능 평가)

  • Kim, Young Bae;Kim, Eun Ju;Yoon, Jonghyuk;Song, Hyoungwoon
    • Applied Chemistry for Engineering
    • /
    • v.30 no.1
    • /
    • pp.62-67
    • /
    • 2019
  • This study was focused on the design and the performance analysis of integral Hot BoP for recovering waste heat from high-temperature exhaust gas in 2 kW class solid oxide fuel cell (SOFC). The hot BoP system was consisted of a catalytic combustor, air preheater and steam generator for burning the stack exhaust gas and for recovering waste heat. In the design of the system, the maximum possible heat transfer was calculated to analyze the heat distribution processes. The detail design of the air preheater and steam generator was carried out by solving the heat transfer equation. The hot BoP was fabricated as a single unit to reduce the heat loss. The simulated stack exhaust gas which considered SOFC operation was used to the performance test. In the hot BoP performance test, the heat transfer rate and system efficiency were measured under various heat loads. The combustibility with the equivalent ratio was analyzed by measuring CO emission of the exhaust gas. As a result, the thermal efficiency of the hot BoP was about 60% based on the standard heat load of 2 kW SOFC. CO emission of the exhaust gas rapidly decreased at an equivalent ratio of 0.25 or more.

Numerical and experimental analysis of temperature distribution in TEFC induction motor (전폐형 유도전동기의 온도분포에 관한 수치 및 실험적 해석)

  • Yun, Myeong-Geun;Go, Sang-Geun;Han, Song-Yeop;Lee, Yang-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.3
    • /
    • pp.457-472
    • /
    • 1997
  • We studied the temperature distribution and heat transfer characteristics of TEFC induction motor with thermal network program for more efficient design and better cooling performance of it. We knew the characteristics and the windage loss of outer cooling fan from fan test experiments. Frame axial and peripheral heat transfer coefficients and endwinding heat transfer coefficient were measured by various model experiments and then, compared with other experimental results. Frame was the main heat transfer surface, load-side and fan-side surface were not thermally symmetric from the heat flux distribution analysis. Steady and unsteady temperature distributions were measured by real motor experiments. From the results, we knew that rotor surface temperature was higher than coil temperature and the hottest spot in the coil was loadside endwinding outside surface. We compared the simulation results with those of real motor test and the two results showed a good agreement.

A Study on the Effect of Heat Input on the Microstructure and Toughness of Weldments Made by Domestic Flux Cored Wires. (국산 플럭스 코어드 와이어 용접에서 입열량이 용접부의 미세조직과 인성에 미치는 영향)

  • 고진현;국정한
    • Journal of Welding and Joining
    • /
    • v.11 no.4
    • /
    • pp.57-69
    • /
    • 1993
  • In the present study, the microstructure and Charpy V notch toughness of multipass $CO_2$ FCA weldment in three different heat inputs(1-3KJ/mm)were investigated. The weldments using two different domestic FCAW wires(AWS E71T-1 and E71T-5 equivalent) in C-Mn steel were chemically analysed. The following conclusions can be inferred. 1. T-1 wire Showed a stable arc transfer, less spatter and harsh, a better bead spreading and easy slag removal, whereas T-5 wire suffered from the arc stability, which tended to increase spatter and produce a more convex bead. 2.The microsturctures of the top beads of the weldments in three different heat inputs consisted of coarse-grained boundary ferrite and Widmanstatten ferrite side plate with increasing heat inputs. The modest fraction of acicular ferrite in the two wire weldments was observed in the 2KJ/mm heat input. 3.The fine-grained reheated zones of both welds consisted of a duplex microstructure of polygonal ferrite and second phases. 4. The basic flux weldment of T-5wires showed a higher Charpy impact property than that of T-1 wires because of a higher fraction of acicular ferrite in the weld microstructure.

  • PDF