• 제목/요약/키워드: heat equivalent

검색결과 416건 처리시간 0.024초

Integral effect tests for intermediate and small break loss-of-coolant accidents with passive emergency core cooling system

  • Byoung-Uhn Bae;Seok Cho;Jae Bong Lee;Yu-Sun Park;Jongrok Kim;Kyoung-Ho Kang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2438-2446
    • /
    • 2023
  • To cool down a nuclear reactor core and prevent the fuel damage without a pump-driven active component during any anticipated accident, the passive emergency core cooling system (PECCS) was designed and adopted in an advanced light water reactor, i-POWER. In this study, for a validation of the cooling capability of PECCS, thermal-hydraulic integral effect tests were performed with the ATLAS facility by simulating intermediate and small break loss-of-coolant accidents (IBLOCA and SBLOCA). The test result showed that PECCS could effectively depressurize the reactor coolant system by supplying the safety injection water from the safety injection tanks (SITs). The result pointed out that the safety injection from IRWST should have been activated earlier to inhibit the excessive core heat-up. The sequence of the PECCS injection and the major thermal hydraulic transient during the SBLOCA transient was similar to the result of the IBLOCA test with the equivalent PECCS condition. The test data can be used to evaluate the capability of thermal hydraulic safety analysis codes in predicting IBLOCA and SBLOCA transients under an operation of passive safety system.

친수성 아민화된 poly(styrene-ethylene-butylene-styrene) 고분자 분리막 제조 및 투습도 특성평가 (Preparation and Characterization of Hydrophilic Aminated poly(styrene-ethylene-butylene-styrene) Polymer Membrane)

  • 손태양;김지현;박치훈;남상용
    • 멤브레인
    • /
    • 제27권4호
    • /
    • pp.336-343
    • /
    • 2017
  • 요즘 건물 내에서의 생활이 많아진 현대인에게 실내공기의 질은 매우 중요한 개념이고, 새롭게 생각을 해 보아야 하는 문제이다. 실내공기의 질은 실내공기의 온도, 습도 등으로 결정이 된다. 그리고 실내공기 개선을 위해서는 에너지 소비가 심하다는 단점이 있다. 그리하여, 전열교환을 이용하여 이러한 문제를 해결하려는 방법에 대한 연구가 활발히 이루어지고 있다. 따라서, 본 연구에서는 전열교환 분리막 적용을 위하여, poly(styrene-ethylene-butylene-styrene) 고분자에 친수성 치환기인 암모늄을 도입하여 아민화된 SEBS 고분자를 합성하였고, 합성고분자에 대한 특성평가를 진행하였다. 암모늄을 도입하기 위하여 클로로메틸화 반응과 아민화 반응을 통하여 합성을 진행하였다. 결과적으로 합성고분자는 반응용제의 함량이 높아질수록 함수율, 이온교환용량이 증가하였고, 전열교환 분리막에서 중요한 투습도 또한 증가함을 확인할 수 있었다.

STB2강의 고온피로강도 특성에 미치는 열처리의 영향 (Effect of Heat Treatment on High Temperature Fatigue Strength Characteristics of STB2 Bearing Steel)

  • 오세규;김연호;이상국;이종두
    • 한국해양공학회지
    • /
    • 제3권2호
    • /
    • pp.138-144
    • /
    • 1989
  • It has been very important in various industry fields to improve the fatigue strength characteristics of bearings such as bearing life, fatigue limit, etc., because such poor properties could result in shortening the machinery life as well as in decreasing the accuracy. However, no successful heat treatment criterion seems to be available at present. In this study, the effect of the $170^{\circ}C\times120min$ tempering cycles repeated after $380^{\circ}C\times80min$ oil quenching for $800^{\circ}C$ spheroidizing-annealed bearing steel (STB2) as base metal on the $120^{\circ}C$ high temperature rotary bending fatigue strength characteristics were investigated, including the effects on hardness, Charpy impact value and micro-structure, in order to seek for the best heat treatment condition finally. The important results obtained are as follows : 1) The optimal cycle of tempering so that the fatigue strength .sigma. could become the highest was the 4th cycle. And it is confirmed that this $\sigma_{F}$ is about 6 times more increased than that of base metal, and about 1.3 times more increased than the case of the 1 cycle tempered. 2) As a result of the investigation for the effects of tempering cycles on hardness, the hardness at the tempering number of 2 thru 5 cyles was not decreased severely ; only about 10% decrease from those of the quenched and 1 cycle tempered case. Such hardness is equivalent to $H_{R}$/C61-62 with no bad effect on anti-abrasion of bearing steel. 3) In the case of 2 thru 5 cycle tempering as well as 1 cycle tempering, the impact value was not so improved comparing with the case of quenching, but an increase of 5 to 10% could be expected at least. 4) It was experimentally confirmed that the control of the mechanical properties improvement such as fatigue strength and fatigue life for bearing steels could be possible by the number of tempering cycles.

  • PDF

STB2강의 고온피로강도 특성에 미치는 열처리의 영향 (Effect of Heat Treatment on High Temperature Fatigue Strength Characteristics of STB2 Bearing Steel)

  • 오세규;김연호;이상국;이종두
    • 한국해양공학회지
    • /
    • 제3권2호
    • /
    • pp.638-638
    • /
    • 1989
  • It has been very important in various industry fields to improve the fatigue strength characteristics of bearings such as bearing life, fatigue limit, etc., because such poor properties could result in shortening the machinery life as well as in decreasing the accuracy. However, no successful heat treatment criterion seems to be available at present. In this study, the effect of the $170^{\circ}C\times120min$ tempering cycles repeated after $380^{\circ}C\times80min$ oil quenching for $800^{\circ}C$ spheroidizing-annealed bearing steel (STB2) as base metal on the $120^{\circ}C$ high temperature rotary bending fatigue strength characteristics were investigated, including the effects on hardness, Charpy impact value and micro-structure, in order to seek for the best heat treatment condition finally. The important results obtained are as follows : 1) The optimal cycle of tempering so that the fatigue strength .sigma. could become the highest was the 4th cycle. And it is confirmed that this $\sigma_{F}$ is about 6 times more increased than that of base metal, and about 1.3 times more increased than the case of the 1 cycle tempered. 2) As a result of the investigation for the effects of tempering cycles on hardness, the hardness at the tempering number of 2 thru 5 cyles was not decreased severely ; only about 10% decrease from those of the quenched and 1 cycle tempered case. Such hardness is equivalent to $H_{R}$/C61-62 with no bad effect on anti-abrasion of bearing steel. 3) In the case of 2 thru 5 cycle tempering as well as 1 cycle tempering, the impact value was not so improved comparing with the case of quenching, but an increase of 5 to 10% could be expected at least. 4) It was experimentally confirmed that the control of the mechanical properties improvement such as fatigue strength and fatigue life for bearing steels could be possible by the number of tempering cycles.

Changes in ginsenoside compositions and antioxidant activities of hydroponic-cultured ginseng roots and leaves with heating temperature

  • Hwang, Cho Rong;Lee, Sang Hoon;Jang, Gwi Yeong;Hwang, In Guk;Kim, Hyun Young;Woo, Koan Sik;Lee, Junsoo;Jeong, Heon Sang
    • Journal of Ginseng Research
    • /
    • 제38권3호
    • /
    • pp.180-186
    • /
    • 2014
  • Background: This study evaluated changes in ginsenoside compositions and antioxidant activities in hydroponic-cultured ginseng roots (HGR) and leaves (HGL) with heating temperature. Methods: Heat treatment was performed at temperatures of $90^{\circ}C$, $110^{\circ}C$, $130^{\circ}C$, and $150^{\circ}C$ for 2 hours Results: The ginsenoside content varied significantly with heating temperature. The levels of ginsenosides Rg1 and Re in HGR decreased with increasing heating temperature. Ginsenosides F2, F4, Rk3, Rh4, Rg3 (S form), Rg3 (R form), Rk1, and Rg5, which were absent in the raw ginseng, were formed after heat treatment. The levels of ginsenosides Rg1, Re, Rf, and Rb1 in HGL decreased with increasing heating temperature. Conversely, ginsenosides Rk3, Rh4, Rg3 (R form), Rk1, and Rg5 increased with increasing heating temperature. In addition, ginsenoside contents of heated HGL were slightly higher than those of HGR. The highest extraction yield was 14.39% at $130^{\circ}C$, whereas the lowest value was 10.30% at $150^{\circ}C$ After heating, polyphenol contents of HGR and HGL increased from 0.43 mg gallic acid equivalent/g (mg GAE eq/g) and 0.74 mg GAE eq/g to 6.16 mg GAE eq/g and 2.86 mg GAE eq/g, respectively. Conclusion: Antioxidant activities of HGR and HGL, measured by 1,1-diphenyl-2-picrylhydrazyl and 2,2-azino-bis-3-ethylbenzothiazoline-6-sulfonic acid radical scavenging ability, increased with increasing heating temperature. These results may aid in improving the biological activity and quality of ginseng subjected to heat treatments.

인장하중 및 반복하중을 받는 강재 스프링의 변형 성능 평가 (Evaluation of Deformation Capacity of Various Steel Springs Subjected to Tensile Loading or Uniaxial Cyclic Loading)

  • 권희용;황승현;양근혁;김상희;최용수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제26권4호
    • /
    • pp.1-10
    • /
    • 2022
  • 이 연구에서는 강재 스프링을 감쇠 장치로써 사용 가능성을 평가하기 위해서, 강재 스프링의 인장 및 반복하중 실험을 수행하였다. 주요 실험변수는 강재의 종류(SAE9254 및 SS275), 스프링상수(700 N/mm, 1,000 N/mm 및 1,400 N/mm) 및 SAE9254의 열처리 유·무이다. 인장 실험 결과, SAE9254로 제작된 강재 스프링의 설계 스프링상수와 측정 스프링상수의 비는 1.08 ~ 1.13이며, SS275로 제작된 강재 스프링의 설계 스프링상수와 측정 스프링상수의 비는 0.86 ~ 0.97로 측정되었다. 항복 이후 열처리 유·무에 따른 SAE9254로 제작된 스프링의 하중-변위 관계 기울기는 약 240 ~ 251 kN/mm 및 92 N/mm 이었으며, SS275로 제작된 스프링의 하중-변위 관계 기울기는 거의 0이었다. 반복하중 실험 결과에서 모든 실험체는 KDS 41 17 00 (2019)에서 요구하는 변위 의존형 감쇠 장치의 적합 조건인 변위 원점에서의 하중 조건, 최대변위에서 하중 조건 그리고 에너지 소산 능력 조건을 모두 만족하였다. 그리고 열처리 안 된 SAE9254 및 SS275로 제작된 강재 스프링의 등가 감쇠비는 열처리 된 SAE9254로 제작된 스프링에 비해 각각 약 2.8배 및 1.9배 높은 수준이었다.

제주시 공영 주차장 내 여름철 인간 열환경 분석 및 저감 방안 제안 (Analysis of The Human Thermal Environment in Jeju's Public Parking Lots in Summer and Suggestion for Its Modification)

  • 최유리;박수국
    • 한국조경학회지
    • /
    • 제52권3호
    • /
    • pp.18-32
    • /
    • 2024
  • 본 연구는 구성 요소가 다른 제주시 주차장 6곳에서 실측한 미기후 자료와 포장 알베도·수목 요소를 달리한 컴퓨터 시뮬레이션을 통해 여름철 인간 열환경을 분석하고 저감 방안을 제안하는 데 목적을 둔다. 실측한 경우, 알베도로 인한 결과는 유의성이 없었으나 양지와 음지의 차이는 유의성을 보였다. 양지는 PET가 '매우 더움' 단계였으나, 음지는 2단계 낮은 '따뜻함' 단계로 나타났고, UTCI 역시 양지가 '매우 강한 열 스트레스' 단계인 반면 음지는 1단계 낮은 '강한 열 스트레스' 단계를 보이며, 태양 복사에너지의 유입을 줄이는 교목의 역할을 확인할 수 있었다. 시뮬레이션 결과도 실측된 알베도 값을 사용했기 때문에 실측 결과와 유사하게 시나리오 간 차이는 크지 않았다. 수목의 경우, 수관폭이 넓고, 엽면적지수가 높으며, 식재 간격이 좁은 시나리오가 인간 열환경을 저감하는 데 효과적이었고, 수고에 따른 차이는 각 시나리오별 상이한 결과를 보였다. 가장 낮은 PET 값을 보인 시나리오는 H9W9L3D8(수고 9m, 수관폭 9m, 엽면적지수 3.0, 식재 간격 8m)로, 현재 조성된 시나리오와 비교했을 때 PET 0.7단계 하락한 것으로 나타났다. 이로써 조경 요소 중 바닥 포장보다는 교목이 여름철 인간 열환경에 주는 영향이 크다는 점을 확인할 수 있었다.

3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구 (The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response)

  • 박현수
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.117-122
    • /
    • 2018
  • 대용량 3상 시스템 에어컨은 최근 들어 소비 전력 저감을 위해 인버터 회로를 포함하고 있다. 인버터 회로는 교류를 다이오드를 통해 정류하고 DC-link 전원부 콘덴서에 의해 평활된 직류를 사용한다. 이 때 평활에 사용되는 DC-link 전원부 콘덴서는 전압 리플, 전류 리플 조건을 만족하기 위해 전해 콘덴서가 일반적으로 사용된다. 콘덴서의 용량을 줄이게 되면 회로부의 크기 및 무게, 비용을 줄일 수 있게 된다. 본 논문에서는 최소점 추정 PPL(Phase Locked Loop) 위상 제어와 평균 전압 d축 전류제어 기법을 조합하여 입력 리플 전류를 약 90% 저감하는 알고리즘을 제안한다. 입력 리플 전류의 감소로 인해 DC-link 콘덴서의 전류 리플도 감소하므로 콘덴서의 용량을 줄일 수 있지만 전해 콘덴서의 경우 등가 직렬 저항(ESR : Equivalent Series Resistance)이 크기 때문에 발열로 인한 수명이 한계를 가진다. 본 논문에서는 전해 콘덴서 대신 DC-link 단에 전류 리플을 고려한 필름 콘덴서를 선정하는 방법을 제안한다. 필름 콘데서의 정전 용량 선정, 내압 선정, RMS(Root Mean Square) 전류 용량, RMS 전류 주파수 해석을 고려해 콘덴서의 용량을 선정할 경우 1680uF의 전해 콘덴서를 20uF로 용량을 낮추어 설계함으로써 전원부 콘덴서의 크기 및 무게, 비용을 줄였으며 전동기 구동을 통해 동작을 확인하였다.

융설과 토양의 동결-융해 과정을 고려한 겨울철 토양온도의 시공간 분포 모의 (Simulation of Spatio-Temporal Distributions of Winter Soil Temperature Taking Account of Snow-melting and Soil Freezing-Thawing Processes)

  • 권용환;구본경
    • 한국수자원학회논문집
    • /
    • 제47권10호
    • /
    • pp.945-958
    • /
    • 2014
  • 토양온도는 비점오염과 관련된 수문학적 및 생지화학적 과정에 영향을 주는 중요한 물리적 환경인자 중 하나이다. 이 연구에서는 분포형 유역모델인 CAMEL(Chemicals, Agricultural Management and Erosion Losses)의 겨울철 토양온도 모의성능을 개선하기 위해서 융설과 토양 동결-융해 모델을 개발하였으며, 경기도 여주에 위치한 시험유역의 4개 지점에서 3개월 동안 관측한 토양온도 자료를 사용하여 모델을 보 검정하였다. 모의 결과, 표층 토양온도에 대해서는 모델이 토양온도의 시계열 변화를 비교적 잘 재현하는 반면($R^2$ 0.71~0.95, RMSE $0.89{\sim}1.49^{\circ}C$), 하부토양층 온도에 대해서는 경우에 따라 모델의 예측오차가 다소 크게 나타났는데($R^2$ 0.51~0.97, RMSE $0.51{\sim}5.08^{\circ}C$), 이것은 모델에서 토양 깊이별 토성을 동일한 것으로 가정한 것이 주요 원인인 것으로 판단된다. 한편, 개발된 모델은 융설에 의한 단열효과와 토양 동결-융해 과정에서 유입 또는 방출되는 잠열흐름의 영향으로 토양온도의 진폭이 감소하는 현상을 잘 모의하고 있다. 비록 모델 구조의 한계와 자료의 부족으로 토양온도에 대한 다소의 예측오차가 발생하였지만, 개발된 토양온도 모델은 시험유역의 토지이용 및 지형에 따른 토양온도와 적설상당수량의 시공간적 분포를 합리적으로 잘 모의하는 것으로 사료된다.

지상식 LPG 저장탱크의 외부화재에 의한 BLEVE 가능성 해석 (A Study on the Probability of BLEVE of Above-ground LP Gas Storage Tanks Exposed to External Fire)

  • 이승림;이영순
    • 한국가스학회지
    • /
    • 제7권1호
    • /
    • pp.19-23
    • /
    • 2003
  • 최근 국내에서도 정량적 위험성 평가 기법을 위험시설물에 도입하여 위험도를 관리하면서 LPG 저장탱크에 대한 사고후 피해영향평가에 대한 연구는 다각적으로 이루어지고 있으나 BLEVE(Boiling Liquid Expanding Vapor Explosion, BLEVE)의 조건 및 메커니즘 규명에 대한 연구는 별로 이루어지고 있지 않다. 따라서, 본 고에서는 상대적으로 위험성이 큰 지상식 LPG 저장탱크의 BLEVE 가능성에 대해 외국의 Pilot 탱크 시험 결과 및 BLEVE 발생을 위한 소요입열량 계산값을 이용한 연역적 계산방법을 통해 BLEVE 조건 및 가능성을 정량화하여 규명코자 하였다. 또한, 산출된 탱크의 파열압력(burst pressure)과 충전량에 의해 보정된 액 온도를 사용해서 그려진 BLEVE map을 이용하여 BLEVE 조건에서 액위($\%$)가 BLEVE에 어떤 영향을 미칠 것인가를 규명하였다. 계산결과, 탱크 plate 온도가 $600^{\circ}C$이고, 탱크내부 액온도가 $53^{\circ}C$ 일 때 액충전량은 $43.68\%$ 이상일 경우에 BLEVE의 발생이 가능하다는 결과를 얻었다. 또한, 부천 대성에너지 LPG 충전소와 동일한 사양인 15톤 프로판 탱크를 모델로 하여 BLEVE가 발생하기 위한 외부 누출 및 외부화재 조건을 PHAST(Version 6.00) 및 EFFECTS(Version 2.1) 프로그램을 이용해 계산한 결과 액상 누출시 누출상당직경은 7.2mm, 이상 누출시 누출상당직경은 17.6mm 이상일 경우에 BLEVE가 발생 가능한 최소한의 풀화재 생성조건이 되었고, 풀화재의 크기는 최소 직경 3.3m, 높이 10.4m 이상의 풀화재가 전제되어야 한다는 결과를 얻을 수 있었다.

  • PDF