• Title/Summary/Keyword: heat environment

Search Result 2,458, Processing Time 0.028 seconds

Study On Lagrangian Heat Source Tracking Method for Urban Thermal Environment Simulations (도시 열환경 시뮬레이션을 위한 라그랑지안 열원 역추적 기법의 연구)

  • Kim, Seogcheol;Lee, Joosung;Yun, Jeongim;Kang, Jonghwa;Kim, Wansoo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.583-592
    • /
    • 2017
  • A method is proposed for locating the heat sources from temperature observations, and its applicability is investigated for urban thermal environment simulations. A Lagrangian particle dispersion model, which is originally built for simulating the pollutants spread in the air, is exploited to identify the heat sources by transporting the Lagrangian heat particles backwards in time. The urban wind fields are estimated using a diagnostic meteorological model incorporating the morphological model for the urban canopy. The proposed method is tested for the horizontally homogeneous urban boundary layer problems. The effects of the turbulence levels and the computational time on the simulation are investigated.

Estimation of Expected Temperature Using Heat Balance Model and Observation Data

  • Kim, Eun-Byul;Park, Jong-Kil;Jung, Woo-Sik
    • Asian Journal of Atmospheric Environment
    • /
    • v.9 no.3
    • /
    • pp.214-221
    • /
    • 2015
  • This study considers mean skin temperature to calculate expected temperature using the new heat balance model because the skin temperature is the most important element affecting the heat balance outdoors. For this, we measured the skin temperature in high temperature condition of Korea and applied it to calculate the expected temperature. The calculated expected temperature is compared with the result calculated using previous models which use the estimated mean skin temperature by considering metabolic rate only. Results show that the expected temperatures are higher when measured mean skin temperature is applied to the model, compared to the expected temperature calculated by applying mean skin temperature data calculated using metabolic rate like previous models. The observed mean skin temperature was more suitable for outside conditions and expected temperature is underestimated when mean skin temperature calculated by the equation using metabolic rate is used. The model proposed in this study has a few limitations yet, but it can be applied in various ways to facilitate practical responses to extreme heat.

Thermal Environment Characteristics of Permeable Cement Concrete Pavement( I ) ($\cdot$보수성 시멘트 콘크리트 포장의 열환경 특성( I ))

  • Ryu Nam-Hyong;Yoo Byung-Rim
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.32 no.6 s.107
    • /
    • pp.82-94
    • /
    • 2005
  • This study was undertaken to measure and analyze the thermal environment characteristics of the grey permeable cement concrete pavement(GPCCP), the permeable cement concrete brick pavement(PCCBP) compared with impermeable cement concrete pavement(ICCP) and bare soil(BS) under the summer outdoor environment. Following is a summary of major results. 1) The peak surface temperature was greatest in the GPCCP$(54.2^{\circ}C)$ followed by ICCP$(47.2^{\circ}C)$ rut August 2, 2002, the hottest day$(35.3^{\circ}C\;of\;highest\;temperature)$ during the experiment; peak temperature in the ICCP and BS were $45.5^{\circ}C)$ and $45.3^{\circ}C)$ respectively. 2) Analysis of heat budget of the pavements has revealed that the heat environment was worse in the GPCCP than that in the ICCP and that this was mainly due to a low albedo in the former(0.2) relative to that of the latter(0.4). 3) Analysis of heat budget of the pavements has revealed that the heat environment was worse in the GPCCP than that in the PCCBP, BS and that this was mainly due to a decreased latent heat resulting from a time dependent decreasing impact of rainfall. 4) It is necessary to make cool pavements to further studies on light-colored surface materials for attaining high albdo and construction methods which can enhance the latent heat through the continuous evaporation from pavements surface. 5) Vertical arrangement of pavement layers has not been considered in the present study, which has been focuses on the heat characteristics of the surface layer materials. Accordingly, future studies will have to be empasized on pavement methods including the vertical arrangement of the pavement layers.

A study on the development of thermal environment prediction program in tunnel of the subway (지하철 터널내 열환경 예측 프로그램 개발에 관한 연구)

  • Kim, J.R.;Kim, D.G.;Kum, J.S.;Choi, K.H.;Jeong, H.M.;Park, J.T.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.504-516
    • /
    • 1997
  • Recently scientists and engineers are developing a system to get waste heat of low-temperature level with advanced heat pump, which have not been used up to now. As the reason, it is necessary to examine capability of using waste heat which is raised up in the tunnel of subway out of widely distributed low-temperature waste heat in large cities. Therefore we surveyed thermal environment of the tunnel of subway in $S\check{o}my\check{o}n$, downtown of Pusan, from November 1995 to December 1996 and developed a program to predict the thermal environment of subway on the basis of experimental data and the geometries of tunnels. This paper has proved availability of waste heat of subway when the measured results obtained in subway in the winter time and the simulated results of thermal environment prediction program are compared, as well as has reported results of estimating reliability of the simulation program. As the result, the charateristics of thermal environment in the tunnel of subway in $S\check{o}my\check{o}n$ station in the winter time are to be followed; 1) temperature in the tunnel is about $10^{\circ}C$ higher than outside air temperature, 2) temperature change in the tunnel is less than that in the platform so that we may obtain stable heat source, 3) and when the measured results obtained in subway in the winter time and the simulated results of thermal environment prodiction program is compared, both results show similar tendency. Therefore, we confirm estimating reliability of the simulation program.

  • PDF

BODY HEAT CONTENT, HEAT PRODUCTION AND RESPIRATION IN SHEEP EXPOSED TO INTERMITTENT COLD

  • Lee, S.R.;Sasaki, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.7 no.3
    • /
    • pp.357-362
    • /
    • 1994
  • Five adult sheep were exposed to intermittent cold for 12 h (18:00-06:00) at an air temperature of $5{\pm}1^{\circ}C$ followed by 12 h (06:00-18:00) at $25{\pm}2^{\circ}C$ over a period of 8 days continuously. Carotid artery blood (Tc), mean skin (Ts) and mean body (Tb = 0.86 Tc + 0.14 Ts) temperatures, heat production rate (HP), respiratory evaporative heat loss, respiration rate (RR) and volume were measured before and after exposure. Tc during the 12 h cold period of intermittent cold exposure was similar to that during the corresponding period in the warm environment, while Tc in the $25^{\circ}C$ of intermittent cold was higher (p < 0.05) than that in the corresponding period in the warm environment. Ts during the cold period markedly decreased (p < 0.001) by about $9^{\circ}C$ when compared with that in the corresponding time period in the warm environment, while Ts during the $25^{\circ}C$ period of intermittent cold recovered to a similar level to that in the warm environment. Tb was lower (p < 0.001) during the cold period of intermittent cold, whereas a slight increase in Tb during the $25^{\circ}C$ period of intermittent cold was significant (p < 0.05) when compared with the value during the similar period in the warm environment. HP was greatly increased (p < 0.001) by cold exposure, followed by an immediate decrease during the first one hour of the 12 h warm period, reaching a similar level to that in the warm environment. A lower (p < 0.05) RR was observed during both the cold and $25^{\circ}C$ period of intermittent cold than during the corresponding periods in the warm environment. The results of the present investigation clearly show that the body temperature of sheep increased during a 12 h warm period following 12 h of exposure to cold. These results suggest that during a warm period of an intermittent cold exposure cycle, heat could be shored in the animal body.

The Relationship between Increased Cold Tolerance Resulting from Cool Clothing on Heat Tolerance (의복을 이용한 내한성 향상 훈련이 내열성에 미치는 영향)

  • 이종민
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.21 no.4
    • /
    • pp.669-676
    • /
    • 1997
  • The purpose of this study is to examine the effect of the improved cold tolerance resulting from cool clothing in winter on heat tolerance in summer. Ten healthy women were divided into two groups, cold group(C group) (n=5) and warm group(W group) (n=5) . In the previous study, C group was proved that their cold acclimatization was achieved through wearing cool clothing from September to February of the following year, while Wgroup was not proved because of wearing warm clothing during same period. After February, no more clothing training was continued in two groups. To determine the heat tolerance, both groups were exposed from a thermoneutral environment(25$\pm$1$^{\circ}C$, 50$\pm$5% R.H.) to a hot environment (35$\pm$1$^{\circ}C$, 50$\pm$5% R.H.) before and after clothing training, respectively September in 1994 and truly in 1995. Rectal temperature, skin temperatures, thermal sensation and comfort were measured every 10 min., and Os uptake was measured at 10, 45, 85 min. after entering the chamber for 5 min. Body weight was measured before and after the experiment and amount of local sweat was measured during the 90 min long experiment. The results are as follows: Rectal temperatures in 35'c environment of C group were increased after training when compared with before clothing, while those of W group were not changed. But the changes of rectal temperature and heat production during 90 min in hot environment were almost the same in two groups after training. And mean skin temperatures, the changes of mean skin temperatures during 90 min in hot environment, total sweat amount and local sweat amount after training were also the same in two groups. From these results, it might be supposed that the heat loss of two groups were the same but the heat production, especially heat production during rest in C group was higher than in Wgroup. This fact suggests that the increase of rest heat production from cold acclimatization in winter is maintained to summer of the following year. And mild cold acclimatization coming from westing cool clothing does not have a negative effect on heat tolerance.

  • PDF

Effectiveness of Cooling Vest in Hot Environment (더운환경에서의 냉각조끼의 착용효과에 관한 연구)

  • 최정화;황경숙
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.1
    • /
    • pp.83-90
    • /
    • 2001
  • Cooling garments are being considered for reducing heat strain in hot environment. We evaluated the effectiveness of ice gel-based cooling vest in hot environment both resting and exercising. Four male subjects were exposed to heat(4$0^{\circ}C$, 50%RH) with vest or without it. The results were as follows; In case of the trial wearing ice gel-based cooling vest, total body weight loss, and local sweat volume were less than those without it. Mean skin temperature, rectal temperature, pulse, energy expenditure, temperature of inside clothes, and humidity of inside also were lower than those without cooling vest. By subjective thermal sensation, subjective humidity sensation, and thermal comfort sensation, it was proved that non-wearing vest decreased comfort than wearing that. These results suggested that wearing ice gel-based cooling vest reduced human heat strain in hot environment both resting and exercising.

  • PDF

Improving the Thermal Environment of Balcony in Apartment House (공동주택 발코니의 열환경 향상방안)

  • Park, Sun-Hyo;Bae, Sang-Hanw;Hong, Cheon-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.41-46
    • /
    • 2003
  • In recent days, it is usual case to extend the dwelling area to the balcony which is provided by service area. But the use of the extended area can be arisen discomfort with a view point of thermal environment by excessive heat accumulation in summer and excessive cold draft in winter. In this study, the skills were reviewed to improve the thermal environment of the extended area and evaluations were carried out. Additional heat supply by heat-convector installed at the lower end of the curtain wall can improve the thermal environment of the extended area and also arise surface temperature of the curtain wall surface. And aluminum plate installed under the floor could not improve the thermal environment but it was effective to shortening the initial heating time.

  • PDF

A Study on Quantitative Estimation for prevention of Heat Island by Using New & Renewable Energy (신재생에너지 적용이 도시열섬방지에 미치는 기여도 분석)

  • Son, Won-Tug;Park, Jung-Han;Park, Kyung-Soon
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.508-513
    • /
    • 2009
  • Significant air temperature increases in urban areas are known as the heat island phenomenon in a global scale. Therefore, we use numerical model in order to analyze quantitative effects by using new & renewable energy on the heat island phenomenon in urban area. The present study quantitatively analyzes the Urban Heat Island Effects, Energy-Saving Effects, and Environmental Load Decrease Effect along New and Renewable Energy Application which is 10% of the Building Energy Consumption.

  • PDF

A Study on the Occurrence Characteristics of Tropical Night Day and Extreme Heat Day in the Metropolitan City, Korea (한반도 대도시의 폭염 및 열대야 발생 특성에 대한 연구)

  • Kim, Eun-Byul;Park, Jong-Kil;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.873-885
    • /
    • 2014
  • To identify the characteristics of extreme heat events and tropical nights in major cities, the correlations between automated synoptic observing station (ASOS), automatic weather station (AWS), and temperature in seven metropolitan areas were analyzed. Temperatures at ASOS were found to be useful sources of the reference temperature of each area. To set the standard for identifying dates of extreme heat events in relation to regional topography and the natural environment, the monthly and yearly frequency of extreme heat in each region was examined, based on the standards for extreme heat day (EHD), tropical night day (TND), and extreme heat and tropical night day (ETD). All three cases identified 1994 as the year with the most frequent heat waves. The frequency was low according to all three cases in 1993, 2003 and 2009. Meanwhile, the yearly rate of increase was the highest in 1994, followed by 2010 and 2004, indicating that the frequency of extreme heat changed significantly between 1993 and 1994, 2003 and 2004, and 2009 and 2010. Therefore all three indexes can be used as a standard for high temperature events. According to monthly frequency data for EHD, TND, and ETD, July and August accounted for 80% or more of the extreme heat of the entire year.