• 제목/요약/키워드: heat dissipation system

검색결과 140건 처리시간 0.03초

Boundary layer analysis of persistent moving horizontal needle in Blasius and Sakiadis magnetohydrodynamic radiative nanofluid flows

  • Krishna, Penem Mohan;Sharma, Ram Prakash;Sandeep, Naramgari
    • Nuclear Engineering and Technology
    • /
    • 제49권8호
    • /
    • pp.1654-1659
    • /
    • 2017
  • The boundary layer of a two-dimensional forced convective flow along a persistent moving horizontal needle in an electrically conducting magnetohydrodynamic dissipative nanofluid was numerically investigated. The energy equation was constructed with Joule heating, viscous dissipation, uneven heat source/sink, and thermal radiation effects. We analyzed the boundary layer behavior of a continuously moving needle in Blasius (moving fluid) and Sakiadis (quiescent fluid) flows. We considered Cu nanoparticles embedded in methanol. The reduced system of governing Partial differential equations (PDEs) was solved by employing the Runge-Kutta-based shooting process. Computational outcomes of the rate of heat transfer and friction factors were tabulated and discussed. Velocity and temperature descriptions were examined with the assistance of graphical illustrations. Increasing the needle size did not have a significant influence on the Blasius flow. The heat transfer rate in the Sakiadis flow was high compared with that in the Blasius flow.

자연대류를 고려한 초전도 전류도입선의 최적 설계 (Optimal design of HTS current lead considering natural convection)

  • 손봉준;설승윤
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.269-273
    • /
    • 2003
  • In this paper the HTS current lead for superconducting device is studied numerical method. The current lead is cooled by surrounded He gas by natural convection. To find wall heat flux, the linearization method is adopted Numerical results using natural convection cooling are compared with conventional cooling methods such as conduction cooling and vapor cooling. The results shows that the minimum heat dissipation is much smaller than conduction cooling. Also, the minimum heat dissipation is obtained for the non-zero gradient of temperature at warm end. HTS current lead operating current sharing mode is reduce heat flow to superconducting system.

  • PDF

방열특성 제어를 위한 PWM 전류제어 기반 LED 모듈 개발 (Development of LED Module Control-based PWM Current for Control of Heat-dissipation)

  • 이승현;문한주;허성범;최성대
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.129-135
    • /
    • 2015
  • This paper shows significant methods that improve the lifespan of LED modules as well as efficiently using an aluminum heat-sink for LED module in high power. It proposes a method that raises stability and lifespan to protect LED modules and the power unit when the LED module has been used for a long hours at high temperatures. During the research, we applied a method of pulse-width modulation (PWM) in order to prevent the phenomenon that the entire power of a system is turned off and the lifespan is reduced when the LED nodule reacts to the high temperatures. To protect the LED module and SMPS based on high efficiency, a temperature sensor is attached underneath the circuit board and the sensor measures the temperature of circuit board when the LED module is powered on. The electrical power connected to SMPS is controlled by PWM when the temperature of the LED module reaches a particular temperature.

The Effect of Spacer on Microclimate and Comfort Sensation in Protective Clothing for Firefighters

  • Chung, Gi-Soo;Lee, Dae-Hoon
    • 한국의류산업학회지
    • /
    • 제4권6호
    • /
    • pp.564-566
    • /
    • 2002
  • Protective clothing for firefighters typically consists of a flame resistant outer shell and inner layers. The inner layers are generally composed of a moisture barrier and a thermal barrier. On performing the task in fire place the heat and perspiration generated from the body become trapped inside the protective clothing. Those heat and moisture result into heat-stress and physical fatigue of fire fighter, which hinder the work. Therefore, the system of clothing designs and material layers must be chosen carefully to balance protection and comfort. 3 kinds of protective clothing of 3 layer structure were used in the experiment of physiological comfort. From the comparison of wear trials with the 3 kinds of layers in firefighters clothing, it indicates that the moisture dissipation of A+B2+C was highest, following A+BI+C andA+B3+C. And the heat dissipation of A+BI+C and A+B2+C were better than A+B3+C. In the protective clothing with A+B3+C, heat and perspiration generated through exercise remained in clothing system long and caused discomfort.

LED 조명 방열 환경에서 진동형 히트파이프의 작동 특성 (Operational Characteristics of Pulsating Heat Pipes for the Application to the Heat Dissipation of LED Lighting)

  • 방광현;김형탁;박해균
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.830-836
    • /
    • 2012
  • An efficient cooling system is essential for the electronic packaging such as a high-luminance LED lighting. A special heat transport technology, Pulsating Heat Pipe (PHP), can be applied to the cooling of LED lighting. In this paper, the operational characteristics of the PHP in the imposed thermal boundary conditions of LED lighting were experimentally investigated. The experimental PHP was made of copper tubes of internal diameter of 2.1 mm. The working fluids of ethanol, FC-72, water, acetone and R-123 were chosen for comparison. The results showed that an optimum range of charging ratio exists for high cooling performance; 50% for most of the fluids. Among the five working fluids, water showed the highest heat transfer rate of 260 W. Two distinguished characteristics of pulsating direction were identified. It is also identified that high vapor pressure gradient is one of key parameters for better heat transfer performance.

통신기지국용 하이브리드 냉방기의 성능특성 연구 (Performance Characteristics of a Hybrid Air-Conditioner for Telecommunication Equipment Rooms)

  • 김용찬;최종민;강훈;윤준상;김영배;최광민;이호성
    • 설비공학논문집
    • /
    • 제18권11호
    • /
    • pp.874-880
    • /
    • 2006
  • The power density and heat dissipation rate per unit area of the telecommunication equipment have been increased with the technology development in the footprint of telecommunication hardware. A proper heat dissipation method from the PCB module is very important to allow reliable operation of its electronic component. In this study, a hybrid air-conditioner for the telecommunication equipment room was designed to save energy and obtain system reliability. For high outdoor temperatures, the hybrid system operates in the vapor compression cycle, while, for low outdoor temperatures, the hybrid system works in the secondary fluid cooling cycle with no operation of the compressor. The performance of the hybrid air-conditioner was measured by varying outdoor and indoor temperatures. The hybrid air-conditioner yielded 50% energy saving compared with the conventional refrigeration system when the mode switch temperature was $8.3^{\circ}C$.

플립칩 패키지의 열소산 최적화 연구 (A Study on the Optimization of Heat Dissipation in Flip-chip Package)

  • 박철균;이태호;이태경;정명영
    • 마이크로전자및패키징학회지
    • /
    • 제20권3호
    • /
    • pp.75-80
    • /
    • 2013
  • 전자패키징 기술의 발전에 따라 패키지의 소형화는 집적화에 따른 열 소산 면적 감소로 인하여 패키지의 온도 상승을 초래한다. 온도 상승은 소자의 성능을 저해하여, 시스템 고장을 발생을 유발시키며 수명을 단축시킨다. 본 연구에서는 마이크로 패턴과 세미 임베디드 구조를 결합하여 열 소산을 극대화 시킬 수 있는 새로운 구조를 제안하여 열특성을 평가하였다. 제안 구조의 열특성 평가 결과, 기존 구조에 비하여 최대 온도는 $20^{\circ}C$낮았으며, 범프의 최대 응력은 20%이상 감소하여 제안 구조의 유효성을 확인하였다.

두 열적 단순계로 구성된 복합계의 열역학 (Thermodynamics of a composite system composed of two simple thermal systems)

  • 정평석;김수연
    • 대한기계학회논문집B
    • /
    • 제21권2호
    • /
    • pp.275-284
    • /
    • 1997
  • Thermodynamic behavior of a composite system which is composed of two simple thermal subsystems with constant heat capacities is analyzed, and several thermodynamic phenomena are investigated. The changes of the states and the potential work of the composite system are shown as the interaction between the subsystems in the composite system. The potential work is defined as the possible maximum available work from the composite system, and it is a thermodynamic property of the composite system. The decrease of the potential work is the same as the available work output from the composite system in reversible processes. The dissipation of available work is directly connected to the generation of entropy. The concepts of exergy and internal energy can be explained as a special case of the potential work.

엔진 냉각 시스템 개선에 관한 연구 (A Study on Improvement of Engine Cooling System)

  • 김문헌;오병욱
    • 한국자동차공학회논문집
    • /
    • 제2권2호
    • /
    • pp.103-116
    • /
    • 1994
  • In this study the behavior of engine cooling loss and overall heat transfer coefficient were studied experimentally using naturally aspirated engine and turbo charged engine. Using turbo charging, heat dissipation was increased because of the density of the mixture was increased with increment of inlet air flow rate. Therefore, cooling loss of turbo charged engine is larger than naturally aspirated engine. As taking the measurement of surface temperature of combustion chamber, gas heat transfer coefficient was calculated and found that it has greatly affected to overall heat transfer coefficient. The empirical formula of overall heat transfer coefficient established in order to predict of engine cooling loss and express only as a function of mean piston velocity.

  • PDF

백시트 종류에 따른 태양전지 모듈의 방열 특성 평가 (Evaluation of Heat Transfer Characteristics of PV Module with Different Backsheet)

  • 배수현;오원욱;강윤묵;이해석;김동환
    • Current Photovoltaic Research
    • /
    • 제6권2호
    • /
    • pp.39-42
    • /
    • 2018
  • When the PV module is illuminated in a high temperature region, solar cells are also exposed to the high temperature external environment. The operating temperature of the solar cell inside the module is increased, which causes the power drops. Various efforts have been made to reduce the operating temperature and compensate the power of solar cells according to the outdoor temperature such as installing of a cooling system. Researches have been also reported to lower the operating temperature of solar cells by improving the heat dissipation properties of the backsheet. In this study, we conducted a test to measure the internal temperature of each module components and the external temperature when the light was irradiated according to the surrounding temperature. Backsheets with different thermal conductivities were compared in the test. Finally, in order to explain the temperature difference between the solar cell and the outside of the module, we proposed an evaluation method of the heat transfer characteristics of photovoltaic modules with different backsheet.