• 제목/요약/키워드: heat Index

검색결과 860건 처리시간 0.029초

Summer season temperature-humidity index threshold for infrared thermography in Hanwoo (Bos taurus coreanae) heifers

  • Kim, Na Yeon;Moon, Sang Ho;Kim, Seong Jin;Kim, Eun Kyung;Oh, Mirae;Tang, Yujiao;Jang, Se Young
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권10호
    • /
    • pp.1691-1698
    • /
    • 2020
  • Objective: The study sought to estimate the relationship between body surface temperature (BST) and temperature humidity index (THI) and to present the validity of THI as a heat stress index in the field. Methods: Eight Hanwoo heifers (20 to 32 month) were examined in a field trial, with a space allowance of 10 ㎡ per head. The BST was measured using an infrared thermographic camera. The BST of five body regions (eyes, hindquarters, nose, part of horns, and ears), ambient temperature (AT), and relative humidity (RH) were measured 7 times daily (07, 09, 11, 13, 15, 17, and 19 h) during each season with three replicates. Results: The THI ranged 34.0 to 56.9 during spring (AT, -1.0℃ to 13.4℃), 75.1 to 84.7 during summer (AT, 24.9℃ to 33.6℃), 55.8 to 70.9 during autumn (AT, 13.0℃ to 26.0℃) and 17.5 to 39.2 during winter (AT, -10.4℃ to 1.0℃). In the regression analysis, the coefficient of determination (R2) between THI and BST was 0.88, 0.72, 0.83, 0.86, and 0.85 for the eyes, hindquarters, nose, part of horn, and ears area, respectively. This indicates that BST has a strong correlation with AT and RH. Expression equations were estimated as Y (THI) = 31.54+0.1085X (BST of eyes) and Y (THI) = 30.48+0.1147X (BST of hindquarters) by simple linear regression analysis in this experiment. Conclusion: Consequently, the upper bound for heat stress estimation can be specified ranging from THI of 65 (eyes) to 70 (hindquarters). From this we can expect a precise feeding system for Korean native cattle in the field.

페놀 폼의 연소특성에 관한 연구 (A Study on the Combustion Characteristics of Phenol Foam)

  • 박형주
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.122-127
    • /
    • 2010
  • 외부복사 열원(20, 25, 35, 50, $70kW/m^2$)과 산소/질소의 혼합가스의 농도 변화에 따른 페놀폼의 연소 특성을 분석하였다. 산소지수는 KS M ISO 4589-2를 만족하는 산소지수시험기를 사용하였으며, 점화시간, 임계열속, 그리고 질량감소속도는 ISO 5660-1를 만족하는 mass loss calorimeter를 사용하여 측정하였다. 연구결과, 외부 복사열원에서 임계열유속은 $28.99kW/m^2$, 평균질량감소속도는 $0.56{\sim}1.77g/m^2s$로 측정되었으며, 한계산소지수는 45.1%를 나타내었다. 모든 연구결과를 종합한 결과 페놀 폼이 다른 발포 물질에 비해 아주 우수한 화재안정성을 나타낸다는 것을 알 수 있었다.

우리나라에 적합한 열파의 정의와 그 시.공간적 발생패턴 (A Definition of Korean Heat Waves and Their Spatio-temporal Patterns)

  • 최광용
    • 대한지리학회지
    • /
    • 제41권5호
    • /
    • pp.527-544
    • /
    • 2006
  • 본 연구는 우리나라 실정에 맞는 여름철 강한 무더위인 열파(Heat Wave)를 정의하고, 각 강도별 장기간(1973-2006) 평균적인 열파 발생빈도의 시공간적 분포 특징을 밝히고자 하였다. 고온다습한 한반도 여름몬순 기후하에서 체감온도와 사망자의 관계를 분석하여, 최소 $32.5^{\circ}C$$35.5^{\circ}C,\;38.5^{\circ}C,\;41.5^{\circ}C$의 일최고 열지수(Heat Index)가 3일간 지속되었을 때를 더운기간(Hot Spell) 및 열파(Heat Wave), 강한열파(Strong Heat Wave), 매우강한열파(Extreme Heat Wave) 발생일로 정의하였다. 이를 바탕으로 모든 단계별 열파 연평균 발생빈도를 살펴보면, 해발고도가 높은 고지대나 바다에 인접한 도서지역에서는 낮게 나타나는 반면, 주요 대하천에 인접한 내륙 저지대에서는 연평균 열파 발생빈도 뿐만 아니라 연구기간중 연 최다 열파 발생일수도 장마휴지기(7월 하순-8월 초순)를 중심으로 높게 나타난다 연구기간(1973-2006) 동안 각 단계별 열파일 발생빈도에는 뚜렷한 변화가 없었으나, 더운기간 (Hot Spell)의 최고 발생빈도를 기록한 연도는 1970년대에, 열파(Heat Waves)와 강한열파(Strong Heat Wave)의 최고 발생빈도를 기록한 연도는 1990년대에 각 집중되어 나타났다. 한편, 우리나라의 열파 발생시에는 기온 이외에도 습도의 부가적인 영향이 $4.3-9.5^{\circ}C$ 정도 열파(Heat Wave)의 강도를 높이고 있음을 알 수 있다. 이러한 연구 결과들은 우리나라에 맞는 국가 열파 경보 체계를 구축하는데 기초자료로써 활용될 수 있을 것으로 생각된다.커마 세기를 구할 수 있었다. 이러한 물 흡수선량을 통한 Ir-192 선원의 검교정 방법들은 미국의학물리학회(AAPM) 보고서 TG-43에서 권고한 흡수선량 계산 알고리즘에 바로 적용할 수 있는 것으로 사료된다. 성장 억제 작용은 G0/Gl기를 지체시켜 암세포 증식을 억제하고 apoptosis에 의해 암세포를 사멸시키는 항암 활성을 나타내는 것으로 확인되었으며, 특허 AO가 AG보다 현저한 활성을 보였다. 더 나아가 아가리쿠스 $\beta$-glucan (AG)과 올리고당류 (AO)는 항암 활성을 가진 대체 의약 소재로 개발될 수 있을 것으로 기대된다.eruginosa rhlI의 경우 단일배양보다 혼합배양시 최고 약 40배, P. aeruginosa lasI의 경우 최고 약 250배 그리고 S. aureus luxS의 경우는 단일배양보다 혼합배양시 최고 약 5배 이상 mRNA 발현량이 증가하였다. 또한 세 균주의 4가지 유전자 중 P. aeruginosa의 rhlI와 lasI의 mRNA가 가장 많은 양으로 발현됨을 확인하였다.석되었다. 6. 연 강수량이 17.4% 증가해 월별 평균 강수량 변화가 가장 큰 시나리오 Al은 연 유출량이 24.6% 증가하고, 유사량과 TN, IP 부하량은 각각 60.1%, 14.4%, 27.1%증가하는 것으로 나타났으며, 이에 비하여 연 강수량 증가가 2.5%로 가장 작은 시나리오 B1의 연 유출량 변화는 -0.4% 감소하는 것으로 나타났고, 유사량과 TN, TP 부하량은 각각 14.6%, 3.0%, 7.2% 증가하는 것으로 모의되었다. 7. 강우 발생 일수 변화를 가정한 시나리오에 대한 모의 결과, 연강우일수가 약 10일 감소한 A1-1, A2-1, B1-1, B2-1의 경우, 강우 일수 감소 이전과 연 유출량 변화는 거의

고온건강경보시스템 기준 설정에 관한 연구( I ) - 기준 설정 및 검증 - (Study on the Establishment of Threshold Criteria for Heat Health Watch Warning System in Korea; Part I : Establishment of Criteria and Verification)

  • 박종길;정우식;김은별
    • 한국환경과학회지
    • /
    • 제18권7호
    • /
    • pp.767-780
    • /
    • 2009
  • This study investigates the standard, duration period and excess mortality of extreme heat using the standardized daily mortality data from 1991 to 2004, establishing a standard threshold Criteria for Heat Health Watch Warning System in Korea. It ultimately aims to provide the guidance in building up Heat Health Watch Warning System for Korea by suggesting the standard to quantify thermal stress from heat. The standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city takes into account both daily maximum temperature and daily maximum heat index(HI) and consists of four phases; caution, extreme caution, danger, and extreme danger. Extreme caution phase and danger phase are used as the advisory and warning of extreme heat, respectively. Since the nationwide distribution of the frequency of extreme heat day and the excess mortality rate shows little difference across regions, the standard threshold Criteria for Heat Health Watch Warning System for Seoul metropolitan city can be used for other regions.

응결시간차를 활용한 매스콘크리트의 수화열 조정에 관한 기초적 연구 (A Fundamental Study on the Control of Hydration Heat of Mass Concrete Using Setting Time Difference)

  • 배정렬;윤치환;김기철;한민철;오선교;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.41-45
    • /
    • 2002
  • Placing lift is applied to place mass concrete in order to reduce thermal cracks by hydration heat. But they results in cold joint between placing lifts, which bring about the loss of strength, water tightness and undesirable appearance. Therefore, in this paper, mechanical and hydration heat of mass concrete using super retarding agent developed through previous study are investigated in order to reduce the hydration heat and place it without place lift. According to test results, placing lifts combined with normal concrete and concrete containing super retarding agent have positive effects on reducing hydration heat. Especially, the crack index by thermal stress of the concrete containing super retarding agent less than a quarter, compared to that of plain concrete without placing lifts, and less than a half, compared to that of plain concrete with placing lifts.

  • PDF

호흡변이도 및 호흡지표와 한열의 상관관계에 대한 연구 (Correlation analysis for 9 respiratory indices and the Cold and Heat score)

  • 배노수;오환섭;박영배
    • 대한한의진단학회지
    • /
    • 제12권2호
    • /
    • pp.96-106
    • /
    • 2008
  • Background and purpose : Health is characterized by variability and a loss variability is associated with aging and disease. Normal healthy respiratory patterns are characterized by breath to breath variability. Cold-Heat score are quantified indices in Korean Medicine. The aim of this study is to analyze relations between 9 respiratory indices (including breath to breath variability) and cold-heat score by questionnaire. Method : Respiratory data were measured during 15 minutes and transferred to text file. We calculated 9 respiratory parameters in use of MATLAB7.1. After then we did correlation analysis of 9 respiratory indices and cold-heat score Results and conclusion : EIratio is showed significant correlation with Cold score and weighted Heat score.

  • PDF

광섬유의 굴절을 특성 (Refractive Index Characteristics of Optical Fiber)

  • 육재호
    • 전자공학회논문지 IE
    • /
    • 제46권2호
    • /
    • pp.18-21
    • /
    • 2009
  • 에칭법을 이용하여 광섬유 굴절율 센서를 제작하였으며 그의 굴절율 특성을 연구하였다. 굴절율 1.453-1.46 영역에서 우수한 감도를 나타내었으며 측정파장에 의해 동작점이 이동돼었다. 클래딩 두께가 감소할 수록 센서의 감도가 증가하였으며, 감도는 열에 안정된 특성을 나타내었다. 그리고 굴절율의 증감에 따른 히스테리시스가 거의 나타나지 않았다.

건강군과 미병군의 한열지표 차이에 관한 연구 (A Study on the Difference of Cold-heat Patterns between Health and Mibyeong Group)

  • 김수정;이시우;이영섭
    • 대한예방한의학회지
    • /
    • 제21권1호
    • /
    • pp.49-56
    • /
    • 2017
  • Objectives : In this study, we diagnosed Mibyeong group of adult by taking into Mibyeong Index consideration, and identified the correlation of a Mibyeong group with cold-heat pattern and life quality of them. Methods : The questionnaires were collected by Gallup Korea professional surveyor through face to face interviews. To analyze the differences between health and mibyeong group, we used the descriptive statistics, Pearson's correlation, ANOVA. And multinomial logistic regression was used to generate the odds ratios (ORs) and 95 % confidence interval (CI) for the differences between health and mibyeong group. Results and Conclusions : The gender composition of respondents in this study that there 545 male (49.5%) and 555 female (50.5%). The score of both cold pattern(health: $21.33{\pm}4.25$, MI 1: $22.43{\pm}4.29$, MI 2: $24.09{\pm}5.03$; post hoc test, p <0.001) and heat pattern(health: $18.4{\pm}4.01$, MI 1: $19.48{\pm}4.10$ MI 2: $19.88{\pm}4.81$; post hoc test, p <0.001) in mibyeong group is higher than the score health group. And, these result have no relevance to age. The score of both Physical component summary (PCS) and Mental component summary (MCS) in health group is higher than the score mibyeong group. Cold-heat pattern and quality of life vary significantly according to health status. This results suggest the analysis of cold-heat pattern and quality of life by health status could provide the setting of direction to promote public health depending on health status.

구획 화재에서 스프링클러 열 손실계수 변화에 따른 작동 시간 분석 (Analysis on the Effects of the Heat Loss Coefficient on the Operation Time of Sprinkler in Compartment Fire)

  • 유우준
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.34-39
    • /
    • 2018
  • 본 연구에서는 구획 공간 화재 시 발열량이 급격히 변하는 조건에서 스프링클러헤드의 손실인자 변화에 따른 작동시간을 분석하였다. 이를 위해서 내화보드로 구성된 구획 공간의 크기가 폭 0.3 m, 세로 0.5 m, 길이 3.0 m인 구조물을 제작하고 헵탄(n-Heptane) 풀 화재 실험을 수행하여 구획 공간 내부의 온도 분포, 헵탄의 질량감소율 그리고 발열량을 산출하였다. 또한, Fire Dynamics Simulator (FDS) Version 6.5를 사용하여 실험 조건과 동일한 발열량을 가정하고 스프링클러헤드의 설치위치 및 손실인자(C-factor) 변화에 따른 작동 시간을 분석하였다. 그 결과 반응시간지수(Response Time Index, RTI)가 $100(m{\cdot}s)^{0.5}$이고 작동온도가 $72^{\circ}C$인 스프링클러는 화원 상층부의 기류 온도가 $100^{\circ}C$에서 $300^{\circ}C$로 상승하고, 기류의 속도가 약 0.7 m/s인 경우 C-factor = 0과 1일 때 스프링클러의 작동시간은 최소 30 s~60 s, C-factor = 3일 때 62 s에서 최대 92 s, C-factor = 5일 때 120 s 이상으로 나타났다.

열처리에 의한 Cu(In,Ga)Se2 태양전지 특성에 관한 연구 (A study on Cu(In,Ga)Se2 solar cell characteristic by sintering)

  • 추순남;박정철
    • 한국정보통신학회논문지
    • /
    • 제17권12호
    • /
    • pp.2914-2920
    • /
    • 2013
  • 본 논문은 동시진공증발법으로 제작된 시편을 $500^{\circ}C$에서 열처리한 시편은 기공이 많이 발생되어 결정결함이 발생 되었어 열처리 시 Se분위기하에서 실행을 해야 된다는 것을 알 수가 있었다. 기판온도를 $430^{\circ}C$, $460^{\circ}C$, $480^{\circ}C$, $500^{\circ}C$로 변화주어 제작된 시편을 열처리 한 결과 결정입자 크기가 증가되어 밀도가 향상되었다. 그리고 XRD 분석결과, 열처리 후에 Cu2Se상이 제거되었으며 열처리 전 후의 흡수지수는 큰 변화가 없었다. 이것은 흡수지수는 열처리보다 시편 두께에 의해 결정된다는 것을 알 수가 있었다.