• Title/Summary/Keyword: heat Capacity Ratio

Search Result 215, Processing Time 0.026 seconds

Welding Characteristics on Heat input Changing of Laser Dissimilar Metals Welding (레이저 이종용접에서의 입열량 변화에 대한 용접특성)

  • Mo Yang-Woo;Shin Byung-Heon;Shin Ho-Jun;Yoo Young-Tae
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.2
    • /
    • pp.51-58
    • /
    • 2006
  • Laser welding of dissimilar metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for SM45C and STS304 with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the dissimilar welding, the welding quality of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding qualify is 1600W of the laser power, 0.85m/min of welding speed and $4{\ell}/min$ of pressure for shielding gas.

Comparison of Welding Characteristics on Heat input Changing of Laser Dissimilar Metals Welding (레이저 이종용접에서의 입열량 변화에 대한 용접특성 비교)

  • Shin H.J.;Yoo Y.T.;Shin B.H.;Ahn D.G.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.997-1003
    • /
    • 2005
  • Laser welding of dissimilar metals has been widely used to improve a wear resistance and a corrosion resistance of the industrial parts. The objective of this research works is to investigate the influence of the process parameters, such as the welding for SM45C and STS304 with CW Nd:YAG lasers. The bead-on-plate welding tests are carried out for several combinations of the experimental conditions. In order to quantitatively examine the characteristics of the dissimilar welding, the welding qualify of the cut section, stain-stress behavior and the hardness of the welded part are investigated. From the results of the investigation, it has been shown that the optimal welding condition without defects in the vicinity of the welded area and with a good welding quality is 1600W of the laser power, 0.85m/min of welding speed and 4m/min of pressure for shielding gas.

  • PDF

Experimental Study on Improvement of Bond Performance of RC Beams with High-Strength Shear Reinforcement (고강도 전단철근을 사용한 철근콘크리트 보의 부착성능 향상에 관한 실험적 연구)

  • Kim, Sang-Woo;Kim, Do-Jin;Yoon, Hye-Sun;Baek, Sung-Cheol;Kim, Kil-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.527-534
    • /
    • 2010
  • This study presents a simple method to improve the bond performance of reinforced concrete (RC) beams having high-strength shear reinforcement. In general, the yield strength and the ratio of shear reinforcements are the main parameters governing the shear capacity of RC beams. The yield strength of shear reinforcement, however, has little influence on the bond capacity of RC beams. Therefore, a sudden bond failure of the members with high-strength shear reinforcement can occur before flexural failure. To estimate the structural performance of the proposed method, four RC beams were cast and tested. The main test parameters were the yield strength, ratio, and reinforcing types of shear reinforcements. The experimental results indicated that the proposed method was able to effectively improve the bond performance of RC beams with high-strength shear reinforcement.

Modelling of a Small Domestic Solid Desiccant Dehumidifier (소형 흡착식 제습기의 모델 개발)

  • Kim, Dong-Seon
    • Journal of Institute of Convergence Technology
    • /
    • v.2 no.2
    • /
    • pp.40-48
    • /
    • 2012
  • A small domestic desiccant dehumidifier is modelled using effectiveness models for a desiccant wheel and a wet-air condenser. The desiccant wheel and condenser models are used to compose a system model in the form of a set of simultaneous linear algebraic equations, which is solved by Gauss method. The system model is used to simulate the behaviour of a dehumidifier with a 1kW electric air heater. It is found that the maximu COP is about 0.5 and dehumidification capacity is 18kg/day when the ratio of dehumidification area is 0.7. The optimum wheel thickness and face velocity are found 100mm and 1.5m/s, respectively.

  • PDF

Bond Performance Test for Optimum Mixing Ratio Calculation of the Floatig Floor Method on Roof-top (옥상 뜬바닥 구조공법의 접착제 최적 배합비 산정을 위한 부착성능 실험)

  • Seo, Yu-Hyun;Park, Jun-Mo;Kim, Ok-Kyue;Jung, Il-Gi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.111-112
    • /
    • 2016
  • Waterproofing methods for applying to roof-top in the building are various, but it is not enough to development, which are simplified and low-cost method for old building. Especially, these buildings have not only a low insulation, but a disadvantage for energy. A floating floor method is necessary for this. This study performs an experimentt about bonding capacity of complex panel for waterproofing and heat insulation. The bond strength experiment is based on KS F 4716, and it is considered by bond mix proportion about panel and slab.

  • PDF

Strength Characteristics of Light-weight Insulating Mortar Using Wasted Foam Polystyrene heat Insulating Materials as Recycling Aggregate (폐발포폴리스티렌 단열재를 순환골재로 사용한 경량 단열 모르타르의 강도특성)

  • Kang, Hye Ju;Jin, Eun mi;Kang, Suk Pyo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.221-222
    • /
    • 2016
  • The replacement ratio of waste EPS was varied, and its effect on compressive strength and absorption capacity was investigated. According to the experimental results, The 28th day compressive strengths for the W/C 50% specimens were 17.5~21.2MPa, which was relatively low compared to the 13.6~22.2MPa of the W/C 70%.

  • PDF

A study on weight reduction design of induction motor for high speed train with driving pattern variations (운전패턴변화에 따른 고속전철용 견인전동기의 경량화설계에 관한 연구)

  • 김근웅;배동진;윤종학;이기호;한성수
    • Proceedings of the KSR Conference
    • /
    • 1998.05a
    • /
    • pp.458-465
    • /
    • 1998
  • This paper presents an inverter-driven induction motor used as the traction motor for a high speed drive system that is required safety, reliability and performance and so on, In the respect of traction motor design, it is mainly showed the weight reduction inclination and characteristic investigation due to V/f driving pattern variation of inverter. Particularly, the reduction of V/f ratio pattern effects on the weight of traction motor and badly on the increase of phase current of traction motor in starting point. This method of weight reduction design have to be reached the decision with not only motor but also the consideration of inverter system because of the heat capacity, weight and material cost of inverter according to the increase of current.

  • PDF

Temperature and exhaust gas conversion efficiency of catalytic converters for natural gas vehicles (천연가스자동차 촉매의 온도분포 및 배기정화 특성)

  • Choe, Byeong-Cheol;Kim, Yeong-Gil;Sakai, Takayuki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.2
    • /
    • pp.205-212
    • /
    • 1998
  • Experiments were conducted to investigate the temperature profile and the emissions conversion efficiency of catalytic converters for natural gas vehicles. Two types of the catalyst structure and several transient engine operating conditions were used. The dual-bed catalyst effectively reduced the emissions in a transient period due to the low heat capacity of the front bed. The lanthanoid additives were effective in improving catalyst durability. When the natural gas fueled engine were operated outside of a very narrow window of excess air ratio (from 0.993 to 1.004), the HC and NOx conversion efficiency dropped off. The drop-off were especially fast on the lean side of the window.

Analysis Study on Fire Performance with Internal Anchored Concrete Filled Steel Tube Columns According to Percent of Steel-Fibers (강섬유 콘크리트 혼입율에 따른 내부앵커형 콘크리트 충전기둥 내화성능에 관한 해석적 연구)

  • Kim, Sun Hee;Yom, Kong Soo;Kim, Yong Hwan;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Concrete filled steel tube system has two major advantages. First, the confinement effect of steel tube improves the compressive strength of concrete. Second, the load capacity and deformation capacity of members are improved because concrete restrains local buckling of steel tube. It does, however, involve workability problem of using stud bolts or anchor bolts to provide composite effect for larger cross-sections. While the ribs inside the columns are desirable in terms of compressive behavior, they cause the deterioration in load capacity upon in-plane deformation resulting from thermal deformation. Since the ribs are directly connected with the concrete, the deformation of the ribs accelerates concrete cracking. Thus, it is required to improve the toughness of the concrete to resist the deformation of the ribs. Welding built-up tubular square columns can secure safety in terms of fire resistance if the problem are solved. This study focuses on mixing steel fiber in the concrete to improve the ductility and toughness of the columns. In order to evaluate fire resistance performance, loaded heating test was conducted with 8 specimens. The behavior and thermal deformation capacity of the specimens were analyzed for major variables including load ratio. The reliability of heat transfer and thermal stress analysis model was verified through the comparison of the results between the test and previous study.

The Component Analysis of the Bioflocculant Produced by Strain YG-02 (Strain YG-02가 생산하는 생물응집제의 성분 분석)

  • Jung, Yeon-Gon;Ko, Joon-Il;Chung, Seon-Yong
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.3
    • /
    • pp.201-208
    • /
    • 2019
  • In this study, we analyzed composition of the bioflocculant, which strain YG-02 produces. First, supernatant and suspension from centrifugation of culture fluid of the strain, were used in the flocculation experiment. As a result, the SVI(sludge volume index) added with the suspension, was 182 mL/g, same as the control group with no additive, and the SVI added with supernatant, was 164 mL/g. So, the result above showed that flocculation capacity of the bioflocculant, was dependent on the substance which strain YG-02 produces, not on factors such as the body of germs. As a result of the thermostability test on substances that cause flocculation, the flocculation effect was significantly reduced, compared to the result of the flocculation test, before applying heat to the culture fluid, and it was able to assume that the substance that causes flocculation, was damaged by heat. Additionally, to understand the component of the bioflocculant, analyzation of sugar composition and fatty acid, was conducted. As a result, sugar composition was the polysaccharide consisting of glucose: lactose with molar ratio of 90.75:9.25. Fatty acid content was detected, as 0.0012 g/100g, showing that it contained glycolipid in the bioflocculant. Such results show that the bioflocculant which strain YG-02 produces, is the new bioflocculant, different from bioflocculantstudiedto date.