• Title/Summary/Keyword: health signal

Search Result 989, Processing Time 0.026 seconds

Comparison of ERG Denoising Performance according to Mother Function of Wavelet Transforms (웨이브렛 변환의 모함수에 따른 ERG의 잡음제거 성능 비교)

  • Seo, Jung-Ick;Park, Eun-Kyoo;Jang, Jun-Young
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.756-761
    • /
    • 2016
  • Purpose. Noise occurs at measuring Electoretinogram(ERG) signals as the other bio-signal measurement. It is compared the denoising performance according to the mother function of wavelet transforms. Methods. The ERG signal that generated power supply noise and white noise was used as a sampling signal. The noise of ERG signal was filtered by using haar, db7, bior mother function. The filtering performance of each mother functions was compared using Fourier transform spectrum and SNR(signal to noise ratio). Results. In the haar functioin, the result of the Fourier transform spectrum was that the power supply noise is removed and the white noise performance is not good. The SNR was 27.0404. In the db7 function, the results of Fourier transform spectrum was that the power supply noise is removed and the white noise performance is good. The SNR was 35.1729. In the db7 function, the results of Fourier transform spectrum was that the power supply noise is removed and the white noise performance is the bset. The SNR was 35.4445. Conclusions. The db7, bior function was good results in power supply noise and white noise filtered. The bior function is suitable for filtering noise of the ERG signal.

Implementation of Network System for Bio-physical signal Communication

  • Kim, Jeong Lae;Kang, Jeong Jin;Rothwell, Edward J.
    • International Journal of Advanced Culture Technology
    • /
    • v.1 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • This network system for home care realized communication by the bio-physical signal, to convey physical rhythm. Four function of displacement had point of a Vision, Somatosensory, Vestibular and CNS. Bio-physical signal was decided to design a maximum points and minimum points with 0.01unit in reference level. Bio-physical signal was checked to compound physical condition of body posture for sensory organ. There detected a measurement of Vision, Somatosensory, Vestibular, CNS and BMI. The service of network system of home can be used to support a health care system for health assistant in health care center. It will expect to manage a physical parameter for network communication.

  • PDF

PRELIMINARY STUDY OF WATER CONTENTS AND SIGNAL BEHAVIOR IN FINGERNAIL/EPR DOSIMETRY

  • Choi, Hoon;Choi, Sul A;Lee, Byungil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.4
    • /
    • pp.185-188
    • /
    • 2013
  • Heating method using electric heater was used to reduce water content in fingernail clippings. Authors found that low water content is helpful to measure EPR signal of fingernail sample with enhanced variability. Generally, natural dehydration happens in normal room condition at least one month and needs much time for using in experiment. So, artificial heating method is applied in this study for time savings. Fingernail samples were tested to find effect of water content to the EPR signal on microwave power levels for dosimetry. Low water content in fingernail reduced variability of EPR signal and makes it possible to measure accurate EPR signal. It also made it possible to measure constant movement of EPR signals on several microwave power levels. Although this method was difficult to apply directly in fingernail/EPR dosimetry, we, authors, believe that this heating method would be useful to differentiate MIS2 and RIS which are generally located at the same g-factor and almost impossible to be identified with each other.

Application assessments of concrete piezoelectric smart module in civil engineering

  • Zhang, Nan;Su, Huaizhi
    • Smart Structures and Systems
    • /
    • v.19 no.5
    • /
    • pp.499-512
    • /
    • 2017
  • Traditional structural dynamic analysis and Structural Health Monitoring (SHM) of large scale concrete civil structures rely on manufactured embedding transducers to obtain structural dynamic properties. However, the embedding of manufactured transducers is very expensive and low efficiency for signal acquisition. In dynamic structural analysis and SHM areas, piezoelectric transducers are more and more popular due to the advantages like quick response, low cost and adaptability to different sizes. In this paper, the applicable feasibility assessment of the designed "artificial" piezoelectric transducers called Concrete Piezoelectric Smart Module (CPSM) in dynamic structural analysis is performed via three major experiments. Experimental Modal Analysis (EMA) based on Ibrahim Time Domain (ITD) Method is applied to experimentally extract modal parameters. Numerical modal analysis by finite element method (FEM) modeling is also performed for comparison. First ten order modal parameters are identified by EMA using CPSMs, PCBs and FEM modeling. Comparisons are made between CPSMs and PCBs, between FEM and CPSMs extracted modal parameters. Results show that Power Spectral Density by CPSMs and PCBs are similar, CPSMs acquired signal amplitudes can be used to predict concrete compressive strength. Modal parameter (natural frequencies) identified from CPSMs acquired signal and PCBs acquired signal are different in a very small range (~3%), and extracted natural frequencies from CPSMs acquired signal and FEM results are in an allowable small range (~5%) as well. Therefore, CPSMs are applicable for signal acquisition of dynamic responses and can be used in dynamic modal analysis, structural health monitoring and related areas.

Accident Prevention Model Using Signal Detection Theory: Case of Shipbuilding Industry

  • Pyo, Yeon;Park, Myoung Hwan;Jeong, Byung Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.3
    • /
    • pp.221-230
    • /
    • 2017
  • Objective: The purpose of this study is to draw the accident prevention model using the signal detection theory, and to implement accident prevention program, based on a health promotion and support activities in a shipbuilding company. Background: Workers' health management is perceived important from the human resource management perspective, as well as from the personal perspective. Method: This study developed an accident prevention model by analyzing the correlation between 704 workers' health examination variables, and reviewed the verification of the model through a follow-up survey on the control variables and status of hazards targeting 650 workers for four years from 2007 to 2010. Also, a health promotion program was implemented targeting a production division to improve alcohol habits, smoking, musculoskeletal pain complaints and hearing control indices, which are the control variables of the model. Results: As a result of four years' implementation, the following effects were obtained: the days away from work fell 87.5%, and accident rate dropped 71.5% in 2010, respectively, compared to 2006, before the activity was implemented. Conclusion: This study shows that the accident prevention activities based on workers' health promotion activities are effective to prevent industrial accidents and injuries. Application: The research findings will serve as a practical guideline for establishing preventive measures in the shipbuilding company.

Implementation of Noise Reduction Methodology to Modal Distribution Method

  • Choi, Myoung-Keun
    • Journal of Ocean Engineering and Technology
    • /
    • v.25 no.2
    • /
    • pp.1-6
    • /
    • 2011
  • Vibration-based Structural Health Monitoring (SHM) systems use field measurements of operational signals, which are distorted by noise from many sources. Reducing this noise allows a more accurate assessment of the original "clean" signal and improves analysis results. The implementation of a noise reduction methodology for the Modal Distribution Method (MDM) is reported here. The spectral subtraction method is a popular broadband noise reduction technique used in speech signal processing. Its basic principle is to subtract the magnitude of the noise from the total noisy signal in the frequency domain. The underlying assumption of the method is that noise is additive and uncorrelated with the signal. In speech signal processing, noise can be measured when there is no signal. In the MDM, however, the magnitude of the noise profile can be estimated only from the magnitude of the Power Spectral Density (PSD) at higher frequencies than the frequency range of the true signal associated with structural vibrations under the additional assumption of white noise. The implementation of the spectral subtraction method to MDM may decrease the energy of the individual mode. In this work, a modification of the spectral subtraction method is introduced that enables the conservation of the energies of individual modes. The main difference is that any (negative) bars with a height below zero after subtraction are set to the absolute value of their height. Both noise reduction methods are implemented in the MDM, and an application example is presented that demonstrates its effectiveness when used with a signal corrupted by noise.

High Signal Intensities on T1-Weighted MRI as a Biomarker of Manganese

  • Kim, Yang-Ho
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.105-139
    • /
    • 2005
  • Increased signal in T1-weighted images was observed in the experimental manganese (Mn) poisoning of the non-human primate and a patient with Mn neurointoxication. However, our study showed that the increased signals in magnetic resonance images (MRI) were highly prevalent (41.6%) in Mn-exposed workers. Blood Mn concentration correlated with pallidal index. These changes in MRI tend to disappear following the withdrawal from the source of Mn accumulation, despite permanent neurological damage. Thus increased signal intensities on a T1-weighted image reflect exposure to Mn, but not necessarily manganism. Our study also showed that the concentration of Mn required to produce increased signal intensities on MRI is much lower than the threshold necessary to result in overt clinical signs of manganism. Increased signal intensities in the globus pallidus were determined by manganese accumulation in the animal experiment. Reanalysis of the previous data with the structural equation model revealed that pallidal index (Pl) on MRI reflects target organ dose of occupational Mn exposure

  • PDF

A Study on MsS Guided Wave Scattering from Defects (MsS Guided Wave를 이용한 결함 신호의 분석에 관한 연구)

  • Choi, Boo-Il;Cho, Youn-Ho;Lee, Joon-Hyun;Shin, Dong-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.442-449
    • /
    • 2009
  • An investigation has been made on the relationship between characteristics of torsional mode signal in MsS and SH mode signal in BEM modeling for the defect of stainless steel pipe. In order to compare torsional mode signal with SH mode signal of defect in stainless steel pipe, specimens were made by changing size of depth and width along to circumferential direction 360 degrees. All the defects was detected by torsional mode signal of MsS, especially according to the change of depth size, amplitude of signal was changed. But width change for the circumferential defects has no certain tendency. SH mode signal of BEM modeling shows similar results with torsional mode, with change makes amplitude variation of signal. In this paper, the characteristics of torsional mode and SH mode signals were found. It is possible to predict the circumferential defects for the pipe by SH mode modeling.

The study for electric readout of X-ray signal using MOSFET (MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구)

  • Park, S.K.;Kang, Y.S.;Seo, J.H.;Park, J.K.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

A Novel Transmission Scheme for Compressed Health Data Using ISO/IEEE11073-20601

  • Kim, Sang-Kon;Kim, Tae-Kon;Lee, Hyungkeun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.12
    • /
    • pp.5855-5877
    • /
    • 2017
  • In view of personal health and disease management based on cost effective healthcare services, there is a growing need for real-time monitoring services. The electrocardiogram (ECG) signal is one of the most important of health information and real-time monitoring of the ECG can provide an efficient way to cope with emergency situations, as well as assist in everyday health care. In this system, it is essential to continuously collect and transmit large amount of ECG data within a given time and provide maximum user convenience at the same time. When considering limited wireless capacity and unstable channel conditions, appropriate signal processing and transmission techniques such as compression are required. However, ISO/IEEE 11073 standards for interoperability between personal health devices cannot properly support compressed data transmission. Therefore, in the present study, the problems for handling compressed data are specified and new extended agent and manager are proposed to address the problems while maintaining compatibility with existing devices. Extended devices have two PM-stores enabling compression and a novel transmission scheme. A variety of compression techniques can be applied; in this paper, discrete cosine transformation (DCT) is used. And the priority of information after DCT compression enables new transmission techniques for performance improvement. The performance of the compressed signal and the original uncompressed signal transmitted over the noisy channel are compared in terms of percent root mean square difference (PRD) using our simulation results. Our transmission scheme shows a better performance and complies with 11073 standards.