• Title/Summary/Keyword: health monitoring technique

Search Result 348, Processing Time 0.029 seconds

The Development of Real Time Automatic Patient Position Correction System during the Radiation Therapy Based on CCD: A Feasibility Study (CCD기반의 방사선치료 중 실시간 자동 환자 위치보정 시스템 개발: 타당성 연구)

  • Shin, Dongho;Chung, Kwangzoo;Kim, Meyoung;Son, Jaeman;Yoon, Myonggeun;Lim, Young Kyung;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.191-197
    • /
    • 2013
  • Upon radiation treatment, it is the important factor to monitor the patient's motion during radiation irradiated, since it can determine whether the treatment is successful. Thus, we have developed the system in which the patient's motion is monitored in real time and moving treatment position can be automatically corrected during radiation irradiation. We have developed the patient's position monitoring system in which the patient's position is three dimensionally identified by using two CCD cameras which are orthogonal located around the isocenter. This system uses the image pattern matching technique using a normalized cross-correlation method. We have developed the system in which trigger signal for beam on and off is generated by quantitatively analyzing the changes in a treatment position through delivery of the images taken from CCD cameras to the computer and the motor of moving couch can be controlled. This system was able to automatically correct a patient's position with the resolution of 0.5 mm or less.

Visualization of Structural Shape Information based on Octree using Terrestrial Laser Scanning (3D레이저스캐닝을 이용한 옥트리기반 구조물 형상정보 가시화)

  • Cha, Gichun;Lee, Donghwan;Park, Seunghee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.8-16
    • /
    • 2016
  • This study presents the visualization of shape information based on Octree using 3D laser scanning. The process of visualization was established to construct the Octree structure from the 3D scan data. The scan data was converted to a 2D surface through the mesh technique and the surface was then converted to a 3D object through the Raster/Vector transformation. The 3D object was transmitted to the Octree Root Node and The shape information was constructed by the recursive partitioning of the Octree Root Node. The test-bed was selected as the steel bridge structure in Sungkyunkwan University. The shape information based on Octree was condensed into 89.3%. In addition, the Octree compressibility was confirmed to compare the shape information of the office building, a computer science campus in Germany and a New College in USA. The basis is created by the visualization of shape information for double-deck tunnel and it will be expected to improve the efficiency of structural health monitoring and maintenance.

Manufacturing Method for Sensor-Structure Integrated Composite Structure (센서-구조 일체형 복합재료 구조물 제작 방법)

  • Han, Dae-Hyun;Kang, Lae-Hyong;Thayer, Jordan;Farrar, Charles
    • Composites Research
    • /
    • v.28 no.4
    • /
    • pp.155-161
    • /
    • 2015
  • A composite structure was fabricated with embedded impact detection capabilities for applications in Structural Health Monitoring (SHM). By embedding sensor functionality in the composite, the structure can successfully perform impact localization in real time. Smart resin, composed of $Pb(Ni_{1/3}Nb_{2/3})O_3-Pb(Zr,\;Ti)O_2$ (PNN-PZT) powder and epoxy resin with 1:30 wt%, was used instead of conventional epoxy resin in order to activate the sensor function in the composite structure. The embedded impact sensor in the composite was fabricated using Hand Lay-up and Vacuum Assisted Resin Transfer Molding(VARTM) methods to inject the smart resin into the glass-fiber fabric. The electrodes were fabricated using silver paste on both the upper and bottom sides of the specimen, then poling treatment was conducted to activate the sensor function using a high voltage amplifier at 4 kV/mm for 30 min at room temperature. The composite's piezoelectric sensitivity was measured to be 35.13 mV/N by comparing the impact force signals from an impact hammer with the corresponding output voltage from the sensor. Because impact sensor functionality was successfully embedded in the composite structure, various applications of this technique in the SHM industry are anticipated. In particular, impact localization on large-scale composite structures with complex geometries is feasible using this composite embedded impact sensor.

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 무선 센서네트워크 환경구축을 위한 무선 스펙트럼 분석 및 전송시험에 관한 연구)

  • An, Tea-Ki;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3220-3226
    • /
    • 2011
  • In order to monitor internal risk factors such as fire, terror, etc. on the subway station, the surveillance systems using CCTV and various kinds of sensors have been implemented and recently, introduction of surveillance systems using an advanced IT technology, sensor network technology is tried on several areas. Since 2007, Korean government has made an effort to develop the intelligent surveillance and monitoring system, which can monitor fire, intrusion, passenger congestion, health-state of structure, etc., by using wireless sensor network technology and intelligent video analytic technique. For that purpose, this study carried out field wireless communication environment test on Chungmuro Station of Seoul Metro on the basis of ZigBee that is considered as a representative wireless sensor network before field application of the intelligent integrated surveillance system being developed, arranged and analyzed and ZigBee based wireless communication environment test results on the platform and waiting room of Chungmuro Station on this paper. Results of wireless spectrum analysis on the platform and waiting room showed that there is no radio frequency overlapped with that of ZigBee based sensor network and no frequency interference with adjacent frequencies separated 10MHz or more. As results of wireless data transmission test using ZigBee showed that data transmission is influenced by multi-path fading effect from the number and flow rate of passengers on the platform or the waiting room rather than effects from entrance and exit of the train to/from the platform, it should be considered when implementing the intelligent integrated surveillance system on the station.

Characteristics of Diurnal Variation of Volatile Organic Compounds in Seoul, Korea during the Summer Season (서울지역 여름철 VOCs 일변동 특성에 관한 연구)

  • Park, Jong-sung;Song, In-ho;Kim, Hyun-woong;Lim, Hyung-bae;Park, Seung-myung;Shin, Su-na;Shin, Hye-jung;Lee, Sang-bo;Kim, Jeong-su;Kim, Jeong-ho
    • Journal of Environmental Analysis, Health and Toxicology
    • /
    • v.21 no.4
    • /
    • pp.264-280
    • /
    • 2018
  • In this study, volatile organic compounds (VOCs) were measured using a proton transfer reaction-time of flight-mass spectrometer (PTR-ToF-MS) at the Seoul Metropolitan Area Intensive Monitoring Station (SIMS) in Korea during the summer season of 2018. The results revealed that oxygenated VOCs (OVOCs) contributed a large fraction (83.6%) of the total VOCs, with methanol being the most abundant constituent (38.6%). The VOCs measured at SIMS were strongly influenced by local conditions. Non-volatile organic compounds (NVOCs), such as pinene, increased due to northeasterly wind direction in the morning, and OVOCs and anthropogenic VOCS (AVOCs) increased with northwesterly wind direction during the daytime. This was the result of the eastward location of Bukhansan National Park and the westward location of urban area from the SIMS location. The VOCs included abundant oxidized forms of VOCs, which can affect the generation of fine dust through various response pathways in the atmosphere. The real-time measurement technique using PTR-ToF-MS suggested in this study is expected to contribute to an improved scientific understanding of high-concentration fine dust events because the high temporal resolution makes it possible to analyze the variations of VOCs reflected in dynamic events.

Delphi Survey for COVID-19 Vaccination in Korean Children Between 5 and 11 Years Old (국내 5-11세 소아의 코로나19 백신 접종에 대한 델파이 연구)

  • Choe, Young June;Lee, Young Hwa;Choi, Jae Hong
    • Pediatric Infection and Vaccine
    • /
    • v.29 no.1
    • /
    • pp.37-45
    • /
    • 2022
  • Purpose: During the coronavirus disease 2019 (COVID-19) pandemic, we conducted a Delphi survey that included the experts from the field of COVID-19 immunization in children aged 5-11 years. The aim was to organize collective expert opinions on COVID-19 vaccination in young children in the Republic of Korea, and so thus assist the vaccination policy. Methods: The panels included pediatric infectious disease specialists, preventive medicine experts, infectious disease physicians, and COVID-19 vaccine experts consulting the Ministry of Health and Welfare. The Delphi survey was conducted online using a questionnaire from February 14 to February 27, 2022. Results: The Delphi panels agreed that children were vulnerable to COVID-19, and the severity of illness was modest. Furthermore the panels reported that children with chronic illness were more susceptible to a worsening clinical course. There were generally positive opinions on the effectiveness of COVID-19 vaccination in children aged 5-11 years, and experts gathered a slightly positive opinion that the adverse events of pediatric COVID-19 were not numerous. The benefits of COVID-19 vaccination were evaluated at a level similar to the potential risks in children. Currently, the only approved mRNA platform vaccine in children seemed to be sustainable; however, the recombinant protein platform COVID-19 vaccines were evaluated as better options. Conclusions: Due to the surge of the Omicron variant and an increase in pediatric cases, the COVID-19 vaccination in young children may have to be considered. Panels had neutral opinions regarding the COVID-19 vaccination in children aged 5-11 years. Thus monitoring of the epidemiology and the data about the safety of COVID-19 vaccination should be continued.

Simultaneous Pesticide Analysis Method for Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor and Trifluralin Residues in Agricultural Commodities Using GC-ECD/MS (GC-ECD/MS를 이용한 농산물 중 Bifenox, Ethalfluralin, Metolachlor, Oxyfluorfen, Pretilachlor, Thenylchlor 및 Trifluralin의 동시 분석)

  • Ahn, Kyung Geun;Kim, Gi Ppeum;Hwang, Young Sun;Kang, In Kyu;Lee, Young Deuk;Choung, Myoung Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.104-116
    • /
    • 2018
  • BACKGROUND: This experiment was conducted to establish a simultaneous analysis method for 7 kinds of herbicides in 3 different classes having similar physicochemical property as diphenyl ether(bifenox and oxyfluorfen), dinitroaniline (ethalfluralin and trifluralin), and chloroacetamide (metolachlor, pretilachlor, and thenylchlor) in crops using GC-ECD/MS. METHODS AND RESULTS: All the 7 pesticide residues were extracted with acetone from representative samples of five raw products which comprised apple, green pepper, Kimchi cabbage, hulled rice and soybean. The extract was diluted with saline water and directly partitioned into n-hexane/dichloromethane(80/20, v/v) to remove polar co-extractives in the aqueous phase. For the hulled rice and soybean samples, n-hexane/acetonitrile partition was additionally employed to remove non-polar lipids. The extract was finally purified by optimized Florisil column chromatography. The analytes were separated and quantitated by GLC with ECD using a DB-1 capillary column. Accuracy and precision of the proposed method was validated by the recovery experiment on every crop samples fortified with bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin at 3 concentration levels per crop in each triplication. CONCLUSION: Mean recoveries of the 7 pesticide residues ranged from 75.7 to 114.8% in five representative agricultural commodities. The coefficients of variation were all less than 10%, irrespective of sample types and fortification levels. Limit of quantitation (LOQ) of the analytes were 0.004 (etahlfluralin and trifluralin), 0.008 (metolachlor and pretilachlor), 0.006 (thenylchlor), 0.002 (oxyfluorfen), and 0.02 (bifenox) mg/kg as verified by the recovery experiment. A confirmatory technique using GC/MS with selected-ion monitoring was also provided to clearly identify the suspected residues. Therefore, this analytical method was reproducible and sensitive enough to determine the residues of bifenox, ethalfluralin, metolachlor, oxyfluorfen, pretilachlor, thenylchlor, and trifluralin in agricultural commodities.

Development of the evaluation tool for the food safety and nutrition management education projects targeting the middle class elderly: Application of the balanced score card and the structure-process-outcome concept (중산층 노인대상 식품안전·영양관리 교육 사업 평가를 위한 도구 개발: 균형성과표와 구조·과정·성과 개념 적용)

  • Chang, Hyeja;Yoo, Hyoi;Chung, Harim;Lee, Hyesang;Lee, Minjune;Lee, Kyungeun;Yoo, Changhee;Choi, Junghwa;Lee, Nayoung;Kwak, Tongkyung
    • Journal of Nutrition and Health
    • /
    • v.48 no.6
    • /
    • pp.542-557
    • /
    • 2015
  • Purpose: The aim of this study is to develop an evaluation tool for operation of food safety and nutrition education projects for middle class elderly using the concept of the balanced score card. Methods: After the draft of the evaluation tool for the elderly training projects was completed, it was revised into the questionnaire and the validity of the indicators was tested by the Delphi group. The validity of the indicators was rated using a 5-point scale. The Delphi group consisted of 26 experts in the education sector, 16 government officials, and 24 professionals of the related area in communities. The first round test was conducted from July 9 to July 17, 2012, and 45 persons responded. The second round test was conducted from July 18 to July 25 and 32 persons responded. Results: The indicators, which were answered by more than 75 percent of the experts as 'agree' (4 points), 'strongly agree' (5 point) were included as the final indicators for the evaluation tool: 28 items out of 36 in outcome perspectives, 9 items out of 12 in process perspectives, and 17 out of 20 items in structure perspectives. The score was allocated as 50 points for outcome indicators, 20 points for process indicators, and 30 points for structure indicators. Conclusion: Completion of the evaluation tool is a prerequisite to determine whether the program is effectively implemented. The monitoring tool developed in the study could be applied for identification of the most optimal delivery path for the food safety and nutrition education program, for the spread of the food safety and nutrition education program for middle class elderly.