• Title/Summary/Keyword: health monitoring technique

Search Result 348, Processing Time 0.028 seconds

Determination of Oxycarboxin Residues in Agricultural Commodities Using HPLC-UVD/MS (HPLC-UVD/MS를 이용한 농산물 중 Oxycarboxin의 분석)

  • Choung, Myoung-Gun
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.2
    • /
    • pp.117-124
    • /
    • 2018
  • BACKGROUND: Oxycarboxin(5,6-dihydro-2-methyl-N-phenyl-1,4-oxathiin-3-carboxamide-4,4-dioxide) as oxanthiin is a systemic fungicide commonly used for control of various pathogens in agronomic and horticultural crops. In an effort to develop an analytical method to trace the fungicide, a method using HPLC equipped with UVD/MS was studied. METHODS AND RESULTS: Oxycarboxin was extracted with acetone from hulled rice, soybean, Kimchi cabbage, green pepper, and apple samples. The extract was diluted with saline water, followed by liquid-liquid extraction with methylene chloride. Florisil column chromatography was employed for the purification of the extracts. Oxycarboxin was determined on a Zorbax SB-AQ $C_{18}$ column by HPLC with UVD. Accuracy of the proposed method was validated by the recovery tests from crop samples fortified with oxycarboxin at 3 levels per crop. CONCLUSION: Mean recoveries ranged from 78.3% to 96.1% in five representative agricultural commodities. The coefficients of variation were less than 10%, and limit of quantitation of oxycarboxin was 0.04 mg/kg. A confirmatory technique using LC/MS with selected-ion monitoring was also provided to clearly identify the suspected residue. The method was reproducible and sensitive to determine the residue of oxycarboxin in agricultural commodities.

Neurobiochemical Analysis of Abnormal Fish Behavior Caused by Copper Toxicity (구리 독성에 기인하는 비정상적인 어류행동의 신경생화학적 분석)

  • 신성우;조현덕;전태수;김정상;이성규;고성철
    • Environmental Analysis Health and Toxicology
    • /
    • v.18 no.2
    • /
    • pp.145-153
    • /
    • 2003
  • The goal of this study is to develop a biomarker used in monitoring abnormal behaviors of Japanese medaka (Oryzias latipes) as a model organism caused by hazardous chemicals. Japanese medaka was treated by copper of appropriate sublethal concentrations after starvation for 48 hr. The untreated individuals showed common behavioral characteristics (i.e. , smooth and linear movements). Locomotive activity of the fish was monitored using an image processing and automatic data acquisition system. When treated with copper (100 ppb), the fish showed shaking patterns more frequently. As the concentration of copper increased to 1,000 ppb, activity decreated, and the fish showed an erratic movement. Fish were exposed to copper at various concentrations (0,100 and 1,000 ppb) for 24 hrs, and acetylcholine esterase (AChE) activity was observed. When fish were exposed to 1,000 ppb of copper, the body AChE activities appeared to decrease but the head AChE activities showed little change. Expressions of tyrosine hydroxylase (TH) protein in the different organs from both head (brain) and body (kidney) portions affected by the copper treatment were analyzed using immunohistochemical technique compared with control. Five organs of the fish (olfactory bulb, hyothalamus, optic lobe, pons and myelencephalon regions) showed a relatively strong TH protein expression in the control experiment. A differential expression of TH, however, was observed in the treatment (100 ppb and 1,000 ppb). The treatment (1,000 ppb) significantly suppressed TH protein production in the brain regions. In kidney, however, the same treatment caused little suppression compared with the control. Copper appeared to be less effective in suppression of TH than diazinon, a known TH suppressor. It was concluded that TH could be used at a potential biomarker to monitor the acute copper toxicity in Japanese medaka.

Reliable Transmission of Bio-Data for IEEE 11073 PHD Standards at 6LoWPAN Multi-Hop Wireless Sensor Networks (6LoWPAN 멀티-홉 무선 센서 네트워크에서의 IEEE 11073 PHD 표준을 위한 신뢰성 있는 생체 정보 전송)

  • Woo, Yeon Kyung;Park, Jong Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.10
    • /
    • pp.116-123
    • /
    • 2013
  • In mobile healthcare applications, the reliable transmission of the bio-data is very important. In this article, we present a reliable bio-data transmission technique for mobile healthcare monitoring service at 6LoWPAN multi-hop wireless networks. In particular, we expand IEEE 11073-20601 protocol, and propose the reliable path construction for 6LoWPAN aimed to reliably provide mobile healthcare service over wireless sensor network, using IPv6 network. 6LoWPAN is recognized possibility because it is agree with sensor network by raising Adaptation layer on the MAC layer to transmit IPv6 packets. In this article proposed minimize the algorithm complexity and reliability routing protocol because the 6LoWPAN devices are suitable for low cost, small size and battery that can be used to health care system environment. And detailed procedures and algorithms are presented. We the proposed method to prove the superiority of using NS-3 for compareing with AODV protocol.

Study on the Short Term Exposure Level (STEL) of the Benzene for the Tank Lorry Truck Drivers during Loading Process

  • Park Doo Yong
    • International Journal of Safety
    • /
    • v.3 no.1
    • /
    • pp.27-31
    • /
    • 2004
  • Some of the petroleum products contain benzene which is well known as a confirmed human carcinogen. For example, gasoline products contain benzene ranging up to several percents by weight. High exposures to the benzene and other organic solvents would be likely to occur during intermittent tasks and or processes rather than continuous jobs such as sampling, repair, inspection, and loading/unloading jobs. The work time for these jobs is various. However, most of work time is very short and the representative time interval is 15 minutes. Thus, it is preferable to do exposure assessment for 15 minute time weighted average which is known as a short time exposure level(STEL) by ACGIH rather than for 8-hours TWA. It is particularly significant to the exposure monitoring for benzene since it has been known that the exposure rate plays an important role to provoke the leukemia. Due to the large variations, a number of processes/tasks, the traditional sampling technique for organic solvents with the use of the charcoal and sampling pumps is not appropriate. Limited number of samples can be obtained due to the shortage of sampling pumps. Passive samplers can eliminate these limitations. However, low sampling rates resulted in collection of small amount of the target analysts in the passive samplers. This is originated the nature of passive samplers. Field applications were made with use of passive samplers to compare with the charcoal tube methods for 15 minutes. Gasoline loading processes to the tank lorry trucks at the loading stations in the petroleum products storage area. Good agreements between the results of passive samplers and those of the charcoal tubes were achieved. However, it was found that special cautions were necessary during the analysis at very low concentration levels.

Damage detection in truss structures using a flexibility based approach with noise influence consideration

  • Miguel, Leandro Fleck Fadel;Miguel, Leticia Fleck Fadel;Riera, Jorge Daniel;Menezes, Ruy Carlos Ramos De
    • Structural Engineering and Mechanics
    • /
    • v.27 no.5
    • /
    • pp.625-638
    • /
    • 2007
  • The damage detection process may appear difficult to be implemented for truss structures because not all degrees of freedom in the numerical model can be experimentally measured. In this context, the damage locating vector (DLV) method, introduced by Bernal (2002), is a useful approach because it is effective when operating with an arbitrary number of sensors, a truncated modal basis and multiple damage scenarios, while keeping the calculation in a low level. In addition, the present paper also evaluates the noise influence on the accuracy of the DLV method. In order to verify the DLV behavior under different damages intensities and, mainly, in presence of measurement noise, a parametric study had been carried out. Different excitations as well as damage scenarios are numerically tested in a continuous Warren truss structure subjected to five noise levels with a set of limited measurement sensors. Besides this, it is proposed another way to determine the damage locating vectors in the DLV procedure. The idea is to contribute with an alternative option to solve the problem with a more widespread algebraic method. The original formulation via singular value decomposition (SVD) is replaced by a common solution of an eigenvector-eigenvalue problem. The final results show that the DLV method, enhanced with the alternative solution proposed in this paper, was able to correctly locate the damaged bars, using an output-only system identification procedure, even considering small intensities of damage and moderate noise levels.

Optimal Sensor Placement for Structural Parameter Estimation Using Genetic Algorithm (유전자 알고리즘을 이용한 구조계수추정 목적의 최적 계측점 선정)

  • Bahng, Eun-Young
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.4
    • /
    • pp.9-16
    • /
    • 2010
  • In the health monitoring of civil engineering structures, the optimal sensor placement has a major influence on the quality of the results. This paper considers the problem of locating sensors with the aim of maximizing the data information so that structural parameters or damage of structures can be assessed. An proposed technique using a genetic algorithm is introduced to find the optimal placement of sensors. The sensitivity on modal vectors by structural parameters and the orthogonality of modal vectors have been taken as the fitness function of the genetic algorithm. A simple tower structure is used for example analyses to investigate the feasibility and applicability of the proposed approach. The example analyses show the way how the modal sensitivity and the modal orthogonality in the fitness function have influence on the optimal sensor placement. It is shown that the present method using the proposed fitness function can provide the reliable results.

Safety and Effectiveness of Food Allergen Immunotherapy (Oral): A Systematic Literature Review and Meta-analysis

  • Mo, Jin-A;Joo, Yea-Il
    • International Journal of Contents
    • /
    • v.14 no.3
    • /
    • pp.39-45
    • /
    • 2018
  • Purpose: Food Allergen Immunotherapy (Oral) is a form of immunotherapy administered to patients who are allergic to foods such as egg, milk, and peanut. The food allergen is orally administered to the patient in an escalating dose for desensitization or tolerance development. The safety and effectiveness of the therapy were assessed using a systematic literature review and meta-analysis. Methods: For a literature search, 8 national databases and a number of international databases including Ovid-MEDLINE, Ovid-EMBASE, and Cochrane Library were used; and 13 articles (all from international databases) were selected. The target of Food Allergen Immunotherapy (Oral) included patients with food allergy, and the intervention was food allergen immunotherapy without limiting the food type. The safety and effectiveness of Food Allergen Immunotherapy (Oral) were assessed by reviewing all the articles reporting on the therapy. The control group received standard therapies including aversion therapy, no treatment, anti-histamine treatment, and placebo. Safety was assessed through the incidence of complication and emergency medication. Effectiveness was assessed based on therapy success rate, symptomatic improvement, and quality of life. Results: Although Food Allergen Immunotherapy (Oral) was shown to have successful desensitization in patients with food allergy, the safety of the technique has not yet reached an acceptable level; the possible reason is due to the high rate of complication and frequency of emergency medication. Also, each study employed varying protocols while relying on a small number of participants and a short monitoring period. Conclusion: The results of assessment suggest that the level of evidence from current literature review is low and further research is necessitated for the verification of the safety and effectiveness of the therapy (Grade of Recommendation: A; Level of Technology: II-b).

Damage Detection of Building Structures Using Ambient Vibration Measuresent (자연진동을 이용한 건물의 건전도 평가)

  • Kim, Sang Yun;Kwon, Dae Hong;Yoo, Suk Hyeong;Noh, Sam Young;Shin, Sung Woo
    • KIEAE Journal
    • /
    • v.7 no.4
    • /
    • pp.147-152
    • /
    • 2007
  • Numerous non-destructive tests(NDT) to assess the safety of real structures have been developed. System identification(SI) techniques using dynamic responses and behaviors of structural systems become an outstanding issue of researchers. However the conventional SI techniques are identified to be non-practical to the complex and tall buildings, due to limitation of the availability of an accurate data that is magnitude or location of external loads. In most SI approaches, the information on input loading and output responses must be known. In many cases, measuring the input information may take most of the resources, and it is very difficult to accurately measure the input information during actual vibrations of practical importance, e.g., earthquakes, winds, micro seismic tremors, and mechanical vibration. However, the desirability and application potential of SI to real structures could be highly improved if an algorithm is available that can estimate structural parameters based on the response data alone without the input information. Thus a technique to estimate structural properties of building without input measurement data and using limited response is essential in structural health monitoring. In this study, shaking table tests on three-story plane frame steel structures were performed. Out-put only model analysis on the measured data was performed, and the dynamic properties were inverse analyzed using least square method in time domain. In results damage detection was performed in each member level, which was performed at story level in conventional SI techniques of frequency domain.

A Study of the Strain Measurement for Al 6061-T6 Tensile Specimen using the Digital Image Correlation (디지털 이미지 상관관계를 이용한 Al 6061-T6 인장시험편의 변형률 측정에 관한 연구)

  • Kwon, Oh Heon;Kim, Sang Tae;Kang, Ji Woong
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.4
    • /
    • pp.26-32
    • /
    • 2013
  • A digital image correlation(DIC) method is a whole-field measurement technique that acquires surface displacements and strains from images information which characterized a random speckle as intensity grey levels. Recently years, this DIC method is being developed and used increasingly in various research. In this study, we tried to apply to aluminum alloy(Al 6061-T6) using DIC method and strain gauge. DIC results demonstrated the usefulness and ability to determine a strain. The test specimen used in this study was an aluminum alloy(Al 6061-T6, thickness 1 mm). For a strain measurement, a strain gauge was attached at the center of a specimen. A specimen was lightly sprayed with a white paint and a black dot pattern was sprayed on its fully dried white surface to obtain a random speckle. The experimental apparatus used to perform the tensile test consisted of universal dynamic tester(5 kN; T.O. Co.) under displacement speed of 0.5, 1.0 and 3.0 mm/min. A Model 5100 B Scanner(V. Co.) used to obtain a strain. A CCD camera connected to a PC uses to record the images of the specimen surface. After acquisition, the images were transferred to PC where the DIC software was implemented. An acquired image was evaluated by the DIC program. DIC method for displacement and strain was suggests and it results show a good consistent remarkably. DIC results demonstrated the usefulness and ability to determine surface strain was better than by using classical measurements. The strain field measurement using a DIC is so useful that it can be applied to map strain distributions at a full area. DIC method can evaluate a strain change so it can predict a location of fracture. The findings of the investigation suggest that the DIC method is an efficient and reliable tool for full-field monitoring and detailed damage characterization of materials.

Prevalence of Opisthorchis viverrini Infection in Nakhon Ratchasima Province, Northeast Thailand

  • Kaewpitoon, Soraya J.;Rujirakul, Ratana;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.10
    • /
    • pp.5245-5249
    • /
    • 2012
  • Background: Opisthorchis viverrini infection is a serious public-health problem in Southeast Asia especially in Lao PDR and Thailand. It is associated with a number of hepatobiliary diseases and the evidence strongly indicates that liver fluke infection is the major etiology of cholangiocarcinoma. Objectives: This study aimed to determine actual levels of Opisthorchis viverrini infection in Nakhon Ratchasima province, Northeast Thailand. Methods: A cross-sectional survey was conducted during a one year period from October 2010 to September 2011. O. viverrini infection was determined using a modified Kato's thick smear technique and socio-demographic data were collected using predesigned semi-structured questionnaires. Results: A total of 1,168 stool samples were obtained from 516 males and 652 females, aged 5-90 years. Stool examination showed that 2.48% were infected with O. viverrini. Males were slightly more likely to be infected than females, but the different was not statistically significant. O. viverrini infection was most frequent in the 51-60 year age group and was found to be positively associated with education and occupation. Positive results were evident in 16 of 32 districts, the highest prevalence being found in Non Daeng with 16.7%, followed by Pra Thai with 11.1%, Kaeng Sanam Nang with 8.33%, and Lam Ta Men Chai (8.33%) districts. Conclusion: This study indicates that O viverrini is still a problem in some areas of Nakhon Ratchasima, the patients in this study bing suitable for the purpose of monitoring projects.