• Title/Summary/Keyword: header

Search Result 647, Processing Time 0.023 seconds

A Study on Application Analysis Using RETRAN Computer Code for the Environmental Qualification Flood Analysis Following the Main Feed Water Line Break (주급수관 파단에 따른 내환경검증 침수분석용 전산코드 RETRAN의 적용 해석연구)

  • Park, Young-Chan;Cho, Cheon-Hwey;Hong, Sung-In
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.103-112
    • /
    • 2007
  • Flood issue for nuclear power plants designed and built in 1970 is extremely severe for main steam header compartment and main feedwater line region of intermediate building and lower floor. A calculation for flood level at the main feedwater line isolation compartment is now performing by hand calculation. But, this methodology is quite conservative assumption. The goal of this study was to develop method to analyze flowrate using the RETRAN-3D computer code, and the developed method was applied to flood level analysis following main feedwater line break. As a result of analysis, flood level was low remarkably.

Creep life Prediction for W.M. of High Cr-Mo Steel using Modified Power-law (고 Cr-Mo강의 수정멱수법칙을 이용한 W.M. 크리프 수명예측)

  • An, Jong-Kyo;Yu, Hyo-Sun;Yang, Sung-Mo;Kang, Hee-Yong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.11
    • /
    • pp.951-956
    • /
    • 2008
  • The high temperature creep properties of the generating plant's high temperature tube, pipe and header and such are very significant in accordance with long-time exposure to the high temperature and pressure environment. Not only this, but as the welding procedure is compulsory for the cohesion of components, the creep properties regarding the local microstructures of steel weldment are very important. In order to understand the creep properties regarding the local microstructures of steel weldment, the SP-Creep test which is easy to get sample from the field component was conducted. The local microstructure of steel weldment, that is, W.M. and B.M.'s microstructures were observed using the SEM. The rupture time of W.M. was longer as 110 % averagely in a same condition, which is the consequence of the difference of the microstructure. Each lethargy coefficient of B.M. and W.M. is evaluated by the relation among the temperature, load and the rupture time from SP-Creep Test. The life estimation equation can be induced by the transformation of Power-law. B.M. and W.M. for each $550\;^{\circ}C$ and $575\;^{\circ}C$, the very similar to normal temperature of the domestic thermal power generation in working, are estimated.

Cellular IP and RSVP based on IPv6 (IPv6 기반의 셀룰러 IP와 RSVP)

  • 박승균;오영환
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.12C
    • /
    • pp.1245-1250
    • /
    • 2002
  • For recent years, the environment of use on internet has been changed from the wired internet access to the wireless internet access increasingly, and the use of real time application data has been increased. Therefore the research and evolution of wireless network for providing of user's mobility and QoS at the same time must be essential. IETF already proposed Mobile IPv6 for providing mobility and RSVP for QoS through resource reservation. These future are expected to be used not only wired network but also wireless network. But there are not yet proposed the integration and efficient interworking of two mechanism. For the solution of problem on efficient interworking issue, for instance signaling overhead and reservation delay increasing due to often handoff, this paper first proposed to use of IETF Cellular IP based on Mobile IPv6 for wireless network model with fast mobility and a improved RSVP mechanism using the flow label field in IPv6 header.

Performance Improvement of Traffic Identification by Categorizing Signature Matching Type (시그니쳐 매칭 유형 분류를 통한 트래픽 분석 시스템의 처리 속도 향상)

  • Jung, Woo-Suk;Park, Jun-Sang;Kim, Myung-Sup
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.7
    • /
    • pp.1339-1346
    • /
    • 2015
  • The traffic identification is a preliminary and essential step for stable network service provision and efficient network resource management. While a number of identification methods have been introduced in literature, the payload signature-based identification method shows the highest performance in terms of accuracy, completeness, and practicality. However, the payload signature-based method's processing speed is much slower than other identification method such as header-based and statistical methods. In this paper, we first classifies signatures by matching type based on range, order, and direction of packet in a flow which was automatically extracted. By using this classification, we suggest a novel method to improve processing speed of payload signature-based identification by reducing searching space.

Ship Detection by Satellite Data: Radiometric and Geometric Calibrations of RADARS AT Data (위성 데이터에 의한 선박 탐지: RADARSAT의 대기보정과 기하보정)

  • Yang, Chan-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.1-7
    • /
    • 2004
  • RADARSAT is one of many possible data sources that can play an important role in marine surveillance including ship detection because radar sensors have the two primary advantages: all-weather and day or night imaging. However, atmospheric effects on SAR imaging can not be bypassed and any remote sensing image has various geometric distortions, In this study, radiometric and geometric calibrations for RADARSAT/SAT data are tried using SGX products georeferenced as level 1. Even comparison of the near vs. far range sections of the same images requires such calibration Radiometric calibration is performed by compensating for effects of local illuminated area and incidence angle on the local backscatter, Conversion method of the pixel DNs to beta nought and sigma nought is also investigated. Finally, automatic geometric calibration based on the 4 pixels from the header file is compared to a marine chart. The errors for latitude and longitude directions are 300m and 260m, respectively. It can be concluded that the error extent is acceptable for an application to open sea and can be calibrated using a ground control point.

  • PDF

CANDU-6 Heat Transport System Stability Analysis With Canflex Fuel Bundle (CANFLEX 핵연료를 사용한 CANDU-6의 열수송계통 안정성 분석)

  • Shin, Jung-Cheol;Park, Ju-Hwan;Kim, Tae-Han;Suk, Ho-Chun
    • Nuclear Engineering and Technology
    • /
    • v.27 no.3
    • /
    • pp.358-373
    • /
    • 1995
  • The Heat Transport system loop stability of CANDU-6 reactor using the CANFLEX fuel bundle was studied. The Thermal-hydraulic behavior of CANFLEX fuel bundle is similar to the conventional 37-element fuel bundle since the reactor power and the frictional pressure drop through the fuel channel is almost the same each other, Mounter the CANFLEX fuel bundle gives higher critical channel power and more homogeneous enthalpy distributions in the subchannels than 37-element fuel bundle. The SOPHT modelling or the CANFLEX fuel bundle and the Reactor outlet Header(ROH) interconnection line was made and the stability analysis response of Wolsong-1 reactor with CANFLEX fuel bundle was obtained. Without the ROH interconnection line the Heat Transport system loop using 43-element fuel bundle is unstable like the current 37-element fuel bundle. With the ROH interconnection line, however, the Heat Transport system is stable within $\pm$1% of nominal flow. In the Heat Transport system loop stability point of view for Wolsong-1 plant therefore, the CANFLEX fuel loading is considered to be acceptable.

  • PDF

Stateful SIP Protocol with Enhanced Security for Proactive Response on SIP Attack (SIP 공격 대응을 위한 보안성이 강화된 Stateful SIP 프로토콜)

  • Yun, Ha-Na;Lee, Hyung-Woo
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.1
    • /
    • pp.46-58
    • /
    • 2010
  • The user valence of VoIP services with SIP protocol is increasing rapidly because of cheap communication cost and its conveniency. But attacker can easily modify the packet contents of SIP protocol as SIP header is transmitted by using UDP methods in text form. The reason is that SIP protocols does not provide an authentication function on the transmission session. Therefore, existing SIP protocol is very weak on SIP Packet Flooding attack etc. In order to solve like this kinds of SIP vulnerabilities, we used SIP status codes under the monitoring module for detecting SIP Flooding attacks and additionally proposed an advanced protocol where the authentication and security function is strengthened about SIP packet. We managed SIP session spontaneously in order to strengthen security with SIP authentication function and to solve the vulnerability of SIP protocol. The proposed mechanism can securely send SIP packet to solves the security vulnerability with minimum traffic transmission. Also service delay in SIP proxy servers will be minimized to solve the overload problem on SIP proxy server.

Architecture of SIP-based Effective Hybrid-type Multimedia Conference (SIP 기반의 효율적인 혼성형 멀티미디어 컨퍼런스 구조)

  • Lee, Ki-Soo;Jang, Choon-Seo;Jo, Hyun-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.3
    • /
    • pp.17-24
    • /
    • 2007
  • SIP-based tightly coupled conference, which has a centrally located conference server for controlling and management, can be classified several models according to location of focus and mixer. These are centralized server model, endpoint server model, media server component model and distributed mixing model. However each model has its strength and weakness. In this paper, we propose and implement a SIP-based effective hybrid-type conference model which decreases amount of SIP signaling messages, lowers load of server media mixer, and can be easily expandable to large scale conference. In this model, when the number of participants exceeds a pre-defined limit, the conference server selects some participants which posses specific functions and let them share functions of notifications of conference state event package and media mixing. When each participant subscribes conference state event package to the server, it can indicates its possession of such functions by a specific header message. The server stores the indication to the conference information database, and later uses it to select participants for load sharing. The performance of our proposed model is evaluated by experiments.

Intercooler for Multi-stage Turbocharger Design and Analysis of the Hydrogen Reciprocating Engine for HALE UAV (고고도 장기체공 무인기용 수소 왕복 엔진의 다단터보차저용 인터쿨러 설계 및 해석)

  • Lee, Yang Ji;Rhee, Dong Ho;Kang, Young Seok;Lim, Byoeung Jun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.20 no.1
    • /
    • pp.65-73
    • /
    • 2017
  • Intercoolers for multi-stage turbocharger of the hydrogen reciprocating engine for HALE UAV are installed for reducing the charged air inlet temperature of the engine. The intercooler is air to air, cross flow, plate-fin type and the fin configuration is offset-strip fin which is referenced from the heat exchanger of the ERAST. Most of HALE UAV's cruising altitude is 60,000 ft and the density of air for this altitude is very low compared to sea level. Therefore the required heat transfer area for the HALE UAV is about three-times bigger than the sea level. Consequently, it is essential to design to meet the required efficiency of intercooler in the range of not excessively growing the weight of the heat exchanger. The quasi-one dimensional heat transfer design/analysis for satisfying the requirement of the engine are written in this paper. The numerical analyses for estimating the coolant flow rate of the engine bay and pressure loss in the header and core are also summarized.

Study on Single-Phase Thermal and Hydrodynamic Characteristics in the Entry Region of a Mini-Channel Heat Sink (히트싱크 미세채널 내의 입구유동 영역에서의 단상 열유동 특성에 관한 연구)

  • Jang, Yong-Hee;Kim, Yong-Chan;Lee, Kyu-Jeong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1007-1016
    • /
    • 2006
  • Although the advance in electronic technology enables a large number of circuity to be packed in a small volume, it is simultaneously required to remove the high heat load produced by them. In this study, the heat transfer and pressure drop characteristics of a mini-channel heat exchanger, which is designed for liquid cooling of electronic components, are investigated by varying operating conditions. Water and FC-72 were used as working fluids. The mini-channel heat exchanger was made with circular shape channels having din-meters of 2, 3, and 4 mm in regular intervals, and the channel length was 100 mm. The header and inlet guide pathway to provide uniform inflow were attached at the inlet of the test section. Copper block including the heaters was attached at the sidewall of the test section as a heat source, which provided the heat flux from 5 to $15W/cm^2$. The entrance effects enhanced the heat transfer coefficient in the mini-channel significantly. In addition, the single-phase pressure drop in the mini-channel was very similar to that predicted by the laminar flow correlation except that the transition Re decreased due to flow instability in the entrance region.