• Title/Summary/Keyword: head model

Search Result 1,578, Processing Time 0.028 seconds

The study of shear bond strength of a self-adhesive resin luting cement to dentin (상아질에 대한 자가 접착 레진 시멘트의 전단결합강도에 관한 연구)

  • In, Hee-Sun;Park, Jong-Il;Choi, Jong-In;Cho, Hye-Won;Dong, Jin-Keun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.5
    • /
    • pp.535-543
    • /
    • 2008
  • Purpose: The objective of this study was to compare the bonding characteristics of a new self-adhesive resin cement to dentin, which does not require bonding and conditioning procedure of the tooth surface, and conventional resin cement. The effect of phosphoric acid etching prior to application of self-adhesive resin cement on the shear bond strength was also evaluated. Material and methods: Fortyfive non-carious human adult molars extracted within 6 months were embedded in chemically cured acrylic resin. The teeth were ground with a series of SiC-papers ending with 800 grit until the flat dentin surfaces of the teeth were exposed. The teeth were randomly divided into 3 experimental groups. In group 1, self-adhesive resin cement, RelyX Unicem (3M ESPE, Seefeld, Germany) was bonded without any conditioning of teeth. In group 2, RelyX Unicem was bonded to teeth after phosphoric acid etching. For group 3, Syntac Primer (Ivoclar Vivadent AG, Schaan, Liechtenstein) was applied to the teeth before Syntac adhesive (Ivoclar Vivadent AG, Schaan, Liechtenstein) and Helibond (Ivoclar Vivadent AG, Schaan, Liechtenstein) followed by conventional resin cement, Variolink II (Ivoclar Vivadent AG, Schaan, Liechtenstein). To make a shear bond strength test model, a plastic tuble (3 mm diameter, 3 mm height) was applied to the dentin surfaces at a right angle and filled it with respective resin cement, and light-polymerized for 40 seconds. All the specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before test. Universal Testing Machine (Z020, Zwick, Ulm, Germany) at a cross head speed of 1 mm/min was used to evaluate the shear bond strength. The failure sites were inspected under a magnifier and Scanning Electron Microscope. The data was analyzed with One way ANOVA and Scheffe test at ${\alpha}$= 0.05. Results: (1) The shear bond strengths to dentin of RelyX Unicem was not significantly different from those of Variolink II/Syntac. (2) Phosphoric acid etching lowered the shear bond strength of RelyX Unicem significantly. (3) Most of RelyX Unicem and Variolink II showed mixed fractures, while all the specimens of RelyX Unicem with phosphoric acid etching demonstrated adhesive failure between dentin and resin cement. Conclusion: Shear bond strength to dentin of self-adhesive resin cement is not significantly different from conventional resin cement, and phosphoric acid etching decrease the shear bond strength to dentin of self-adhesive resin cement.

The Design of Broadband Ultrasonic Transducers for Fish Species Identification - Dual Resonance Design of a Ultrasonic Transducer Using a Single Acoustic Matching Layer - (어종식별을 위한 광대역 초음파 변환기의 설계 II - 단일음향정합층을 이용한 이중공진형 변환기의 설계 -)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.1
    • /
    • pp.74-84
    • /
    • 1998
  • A doubly resonant ultrasonic transducer has been designed as an attempt to increase the bandwidth of underwater transducers. The dual resonance conditions were accomplished by attaching a single acoustic matching layer on the front face of a Tonpilz transducer consisted of an aluminum head, a piezoelectric ring, a brass tail and a prestress bolt. A modified Mason's model was used for the performance analysis and the design of transducers, and the constructed transducers were tested experimentally and numerically by changing the impedances and thicknesses of the head, tail and matching layers in the water tank. Two distinct resonance peaks in the transmitting voltage response(TVR) of a developed transducer were observed at 34.3 and 40.4 kHz, respectively, with the difference frequency of 6.1kHz and the center frequency of 37.2kHz. The values of TVR at these frequencies were 136.5 dB re $1\;\muPa/V$ at 34.3 kHz and 136.8 dB re $1\;\muPa/V$ at 40.4 kHz, respectively. Reasonable agreement between the experimental results and the numerical results was achieved. From this result, it is expected that the generation of the distinct resonances at any two desired frequencies can be achieved through the proper choice of the matching layer to provide the impedance transformation between the transducer and the medium.

  • PDF

A Study on the Diagnostic Reference Level of Skull Radiography in Digital Radiography (디지털 방사선 환경에서 두부 방사선검사 시 진단참고수준 검사조건에 대한 고찰)

  • Yeon-Jin, Jeong;Young-Cheol, Joo;Dong-Hee, Hong;Sang-Hyeon, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.897-904
    • /
    • 2022
  • The purpose of this study is to compare the difference in dose and image quality when applying the diagnostic reference level (DRL) test conditions for head radiography in a digital radiation environment and the test conditions currently applied in clinical practice. I would like to review the conditions of radiographic examination. In this study, the head model phantom was targeted, and the investigation conditions were divided into clinical conditions (Clinic), DRL value (DRL75), and DRL average value (DRLmean). For dose, Enterance surface dose (ESD) was measured, and for image quality, signal-to-noise ratio and contrast-to-noise ratio were measured and analyzed for comparison. The average values of skull anterior posterior(AP) ESD according to the changes in test conditions were Clinic 1214.03±4.21 µGy, DRL75 3017.83±8.14 µGy, DRLmean 2283.50±7.09 µGy, and skull lateral (Lat). The average value of ESD was statistically significant with Clinic 762.79±3.54 µGy, DRL75 2168.57±10.83 µGy, and DRLmean 1654.43±6.48 µGy (p<0.01). The average values of SNR and CNR measured in the orbital, maxillary sinus, frontal sinus, and sella turcica were statistically significant (p<0.01). As a result of this study, compared to DRL, the conditions used in clinical practice showed lower dose levels of about 58% for AP and about 70% for Lat., and there was no qualitative difference in terms of image quality. Through this study, it is necessary to consider a new diagnostic reference level suitable for the digital radiation environment, and it is considered that the dose should be reduced accordingly.

The Effect of Aquaplast on Surface Dose of Photon Beam (Aquaplast가 광자선의 표면선량에 미치는 영향)

  • Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.95-100
    • /
    • 1995
  • Purpose : To evaluate the effect on surface dose due to Aquaplast used for immobilizing the patients with head and neck cancers in photon beam radiotherapy Materials and Methods: To assess surface and buildup region dose for 6MV X-ray from linear accelerator(Siemens Mevatron 6740), we measured percent ionization value with the Markus chamber model 30-329 manufactured by PTW Frieburg and Capintec electrometer, model WK92. For measurement of surface ionization value, the chamber was embedded in $25{\times}25{\times}3cm^3$ acrylic phantom and set on $25{\times}25{\times}5cm^3$ polystyrene phantom to allow adequate scattering. The measurements of percent depth ionization were made by placing the polystyrene layers of appropriate thickness over the chamber. The measurements were taken at 100cm SSD for $5{\times}5cm^2$, $10{\times}10cm^2$ and $15{\times}15cm^2$ field sizes, respectively. Placing the layer of Aquaplast over the chamber, the same procedures were repeated. We evaluated two types of Aquaplast: 1.6mm layer of original Aquaplast(manufactured by WFR Aquaplast Corp.) and transformed Aquaplast similar to moulded one for immobilizing the patients practically. We also measured surface ionization values with blocking tray in presence or absence of transformed Aquaplast. In calculating percent depth dose, we used the formula suggested by Gerbi and Khan to correct overresponse of the Markus chamber. Results : The surface doses for open fields of $5{\times}5cm^2$, $10{\times}10cm^2$, and $15{\times}15cm^2$ were $79\%$, $13.6\%$, and $18.7\%$, respectively. The original Aquaplast increased the surface doses upto $38.4\%$, $43.6\%$, and $47.4\%$, respectively. For transformed Aquaplast, they were $31.2\%$, $36.1\%$, and $40.5\%$, respectively. There were little differences in percent depth dose values beyond the depth of Dmax. Increasing field size, the blocking tray caused increase of the surface dose by $0.2\%$, $1.7\%$, $3.0\%$ without Aquaplast, $0.2\%$, $1.9\%$, $3.7\%$ with transformed Aquaplast, respectively. Conclusion: The original and transformed Aquaplast increased the surface dose moderately. The percent depth doses beyond Dmax, however, were not affected by Aquaplast. In conclusion, although the use of Aquaplast in practice may cause some increase of skin and buildup region dose, reductioin of skin-sparing effect will not be so significant clinically.

  • PDF

Regional load deflection rate of multiloop edgewise archwire (Multiloop edgewise arch wire의 부위별 하중변형률)

  • Kim, Byoung-Ho;Yang, Won-Sik
    • The korean journal of orthodontics
    • /
    • v.29 no.6 s.77
    • /
    • pp.673-688
    • /
    • 1999
  • This study was conducted in order to analyze the mechanical characteristics of multiloop edgewise archwire (MEAW). The purposes were 1) to compare load deflection rate (LDR) of MEAW with that of various other arch wires in the individual interbracket span, 2) to compare the wire stiffness in the interbracket span with that in the multi-L-loop region (the span from distal border of the bracket of the lateral incisor to the mesial border of the buccal tube of the second molar), and 3) to verify the experimental results with theoretically derived formula. The single L-loops of five different horizontal lengths and multi-L-loops for the upper and lower arches were made out of .$016\times.022$ permachrome stainless steel wire. Straight segment of plain stainless steel, TMA and NiTi wire of the same dimension were prepared. The LDR was measured using Instron model 4466 with the load cell of 50N capacity at cross head speed of 1.0mm/min, and maximum deflection of 1.0mm. Five specimens were tested under each experimental condition. The wire stiffness number for each interbracket region and multi-L-loop region was calculated from the LDR and the interbracket spans. By dividing the theoretical model of multi-L-loop into 35 linear segments, the energy stored in each segment was obtained. Then the LDR and wire stiffness of single L-loop and multi-L-loop were calculated and compared. The findings were as follows : 1) The average LDR of MEAW in the individual interbracket region was 1/1.53 of that of the NiTi,1/2.47 of TMA and 1/5.16 of the plain stainless steel wire. 2) The wire stiffness of MEAW in the multi-L-loop region was 1.53 times larger than that in the interbracket region, and the LDR was almost twice as large as that of NiTi in that region. 3) According to the theoretically derived equation, the wire stiffness of the single L-loop was lower than that of multi-L-loop. The results of this study suggest that MEAW has the unique mechanical Property which could allow individual tooth movement and transmit elastic force effectively through the entire arch wire.

  • PDF

A Study of The planting Arrangement of Ornamental Trees And Shrubs in Intermane Buddhist Temples. (산지형 사찰에 있어 조경식물 배치형식에 관한 연구)

  • Shim, Jai-Sung;Bae, Jeong-Kwan;Seo, Byung-Key
    • The Journal of Natural Sciences
    • /
    • v.14 no.1
    • /
    • pp.63-81
    • /
    • 2004
  • It is the purpose of this study to arrange in ornamental trees and shrubs the planting that leads to an appropriate type of templescape. The study was designed primarily as an examples for each Buddhist temple which desires further decoration with several ornamental plants, doubles the effectiveness of the Sen-Buddhist meditation, and boosts tourists' attraction. To investigate the planting status and type of trees and shrubs in the precincts of Buddhism temples, We close three temples : They are Nagsansa, Boolgoogsa and Booseugsa, which are intermonatane area temples all together. The results investigated were summarized as follows :1. Planting status and pattern in temples Open spaces of the Daewoogjeon in all temples, a main Sanctuaries in temple buildings, where Buddha is enshrined in, we could not find any kind of trees of shrubs to be planted.Muryangsujeon, a symbol of "Future", which can be also found at Boosugsa temple, is living in Western Elysium world and takes mercy on mankind of this life. Taxus cuspidata was planted at this Muryangsujeon, known as an immeasurable bliss building, where an Amitabha is enshrined in.Total 25 species of trees and shrubs were planted around Birozani building of Buddhist temples, Birozani is enshrined at the Birojion of Boollgoogsa temple.The buddhist Goddess of Mercy which is a buddhist saint for pursuit of fortune and blessing to relieve the mankind is enshrined at Wonchonjeon, Daebijeon and Kwaneumjeon which are able to observe at both Boolgoogsa and Nagsnsa temples, where Euonymus japonicus trees including other 26 species could be found in common at both temples.2. Correlation between trees/shrubs and temple buildingsTrees and flowers symbolizing Buddha are often planted as material sources of gardening to decorate : They are Logerstroemia indica as Buddha's flower, Viburmum opulus var. calvescens resembling Buddha's head, Tilia mandshurica producing the beads of rosary, Gardenia jaminoides Ellis with white flower blade and flower of bliss, not flower to this day and Lotus flowering clearly in the pond filling with dirty water which is able to clarifies the world full of crime, infidelity and injustification. Among these Buddhist' plants, however, Logerstroemia indica could be found in all three temples, and Viburmum opulus var. calvescens at both Nagsansa and Boosugsa. Also, Lager stroemia indica was planted at all three temples and Viburmum opulus var. calvescens at both temples of Nagsansa and Boosugsa. Tilia mandshurica and Gardenia jasminoides Ellis were not found in any temples which might become the subject of investigation.In relation of the buildings of each temples as a sanctified space, the planting of trees and shrubs was not considered for the arrangement, templescape architecture or species. And, also, we could not find in the study any special relationship of trees/ shrubs with the characteristics of temples.With the results obtained through precise studies we presented here in this paper newly designed model of templescape in intermane buddhist temple which can be applied for planting and arrangement of trees or/and shrubs. Basic principles of model in mind are:To consider the correlation of the dominant between plants and temple buildings.To plant trees/shrubs for special functions as well as conditions of temple location.To make tree arrangement correlating to Buddhism spirit.To induce environment friendly plants to be planted, suitable to regional conditions.This redecorated model of templescape might be used as a canon of the tree planting and arrangement in the precincts of Buddhism temples.

  • PDF

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.

Anticipating the Need for Healthcare Resources Following the Escalation of the COVID-19 Outbreak in the Republic of Kazakhstan

  • Semenova, Yuliya;Pivina, Lyudmila;Khismetova, Zaituna;Auyezova, Ardak;Nurbakyt, Ardak;Kauysheva, Almagul;Ospanova, Dinara;Kuziyeva, Gulmira;Kushkarova, Altynshash;Ivankov, Alexandr;Glushkova, Natalya
    • Journal of Preventive Medicine and Public Health
    • /
    • v.53 no.6
    • /
    • pp.387-396
    • /
    • 2020
  • Objectives: The lack of advance planning in a public health emergency can lead to wasted resources and inadvertent loss of lives. This study is aimed at forecasting the needs for healthcare resources following the expansion of the coronavirus disease 2019 (COVID-19) outbreak in the Republic of Kazakhstan, focusing on hospital beds, equipment, and the professional workforce in light of the developing epidemiological situation and the data on resources currently available. Methods: We constructed a forecast model of the epidemiological scenario via the classic susceptible-exposed-infected-removed (SEIR) approach. The World Health Organization's COVID-19 Essential Supplies Forecasting Tool was used to evaluate the healthcare resources needed for the next 12 weeks. Results: Over the forecast period, there will be 104 713.7 hospital admissions due to severe disease and 34 904.5 hospital admissions due to critical disease. This will require 47 247.7 beds for severe disease and 1929.9 beds for critical disease at the peak of the COVID-19 outbreak. There will also be high needs for all categories of healthcare workers and for both diagnostic and treatment equipment. Thus, Republic of Kazakhstan faces the need for a rapid increase in available healthcare resources and/or for finding ways to redistribute resources effectively. Conclusions: Republic of Kazakhstan will be able to reduce the rates of infections and deaths among its population by developing and following a consistent strategy targeting COVID-19 in a number of inter-related directions.

Eye Tracking Using Neural Network and Mean-shift (신경망과 Mean-shift를 이용한 눈 추적)

  • Kang, Sin-Kuk;Kim, Kyung-Tai;Shin, Yun-Hee;Kim, Na-Yeon;Kim, Eun-Yi
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.44 no.1
    • /
    • pp.56-63
    • /
    • 2007
  • In this paper, an eye tracking method is presented using a neural network (NN) and mean-shift algorithm that can accurately detect and track user's eyes under the cluttered background. In the proposed method, to deal with the rigid head motion, the facial region is first obtained using skin-color model and con-nected-component analysis. Thereafter the eye regions are localized using neural network (NN)-based tex-ture classifier that discriminates the facial region into eye class and non-eye class, which enables our method to accurately detect users' eyes even if they put on glasses. Once the eye region is localized, they are continuously and correctly tracking by mean-shift algorithm. To assess the validity of the proposed method, it is applied to the interface system using eye movement and is tested with a group of 25 users through playing a 'aligns games.' The results show that the system process more than 30 frames/sec on PC for the $320{\times}240$ size input image and supply a user-friendly and convenient access to a computer in real-time operation.

Study on the Visual Cells in the Retina of Macropodus ocellatus (Pisces, Osphronemidae) Freshwater Fish from Korea (한국산 담수어류 버들붕어, Macropodus ocellatus (Pisces, Osphronemidae) 망막의 시각세포에 관한 연구)

  • Kim, Jae Goo;Park, Jong Yong
    • Korean Journal of Ichthyology
    • /
    • v.29 no.3
    • /
    • pp.218-223
    • /
    • 2017
  • Using both light and scanning electron microscopies, it was investigated on the visual cells as well as the eyes of Macropodus ocellatus (Pisces, Osphronemidae). This species had a circular lens and yellowish cornea. The eyes had $3.5{\pm}0.2mm$ which is $31.1{\pm}3.0%$ in a percentage of eye diameter relative to head length. The retina ($158.2{\pm}10.6{\mu}m$) was built of several layers, including the visual cell layer which consists of three types of cells: single cons ($27.8{\pm}1.6{\mu}m$) and equal double cone ($33.9{\pm}3.7{\mu}m$), and large rods ($57.3{\pm}1.3{\mu}m$). The visual cell layer then was classified into the correct pattern. All visual cells were clearly distinguished from two parts (inner and outer segments). The elongated rod cells were extend to the bottom of the retinal pigment epithelium. In scanning electron microscopy, the outer segment links to inner segment by so-called calyceal piles. The M. ocellatus single and double cones appearance form a flower-petal arrangement, which is a regular mosaic pattern that contains quadrilateral units by four double cones surrounding a single cone.