• Title/Summary/Keyword: head model

Search Result 1,596, Processing Time 0.035 seconds

Seismic pounding effects on adjacent buildings in series with different alignment configurations

  • Abdel Raheem, Shehata E.;Fooly, Mohamed Y.M.;Abdel Shafy, Aly G.A.;Abbas, Yousef A.;Omar, Mohamed;Abdel Latif, Mohamed M.S.;Mahmoud, Sayed
    • Steel and Composite Structures
    • /
    • v.28 no.3
    • /
    • pp.289-308
    • /
    • 2018
  • Numerous urban seismic vulnerability studies have recognized pounding as one of the main risks due to the restricted separation distance between neighboring structures. The pounding effects on the adjacent buildings could extend from slight non-structural to serious structural damage that could even head to a total collapse of buildings. Therefore, an assessment of the seismic pounding hazard to the adjacent buildings is superficial in future building code calibrations. Thus, this study targets are to draw useful recommendations and set up guidelines for potential pounding damage evaluation for code calibration through a numerical simulation approach for the evaluation of the pounding risks on adjacent buildings. A numerical simulation is formulated to estimate the seismic pounding effects on the seismic response demands of adjacent buildings for different design parameters that include: number of stories, separation distances; alignment configurations, and then compared with nominal model without pounding. Based on the obtained results, it has been concluded that the severity of the pounding effects depends on the dynamic characteristics of the adjacent buildings and the input excitation characteristics, and whether the building is exposed to one or two-sided impacts. Seismic pounding among adjacent buildings produces greater acceleration and shear force response demands at different story levels compared to the no pounding case response demands.

Facial Contour Extraction in PC Camera Images using Active Contour Models (동적 윤곽선 모델을 이용한 PC 카메라 영상에서의 얼굴 윤곽선 추출)

  • Kim Young-Won;Jun Byung-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2005.11a
    • /
    • pp.633-638
    • /
    • 2005
  • The extraction of a face is a very important part for human interface, biometrics and security. In this paper, we applies DCM(Dilation of Color and Motion) filter and Active Contour Models to extract facial outline. First, DCM filter is made by applying morphology dilation to the combination of facial color image and differential image applied by dilation previously. This filter is used to remove complex background and to detect facial outline. Because Active Contour Models receive a large effect according to initial curves, we calculate rotational degree using geometric ratio of face, eyes and mouth. We use edgeness and intensity as an image energy, in order to extract outline in the area of weak edge. We acquire various head-pose images with both eyes from five persons in inner space with complex background. As an experimental result with total 125 images gathered by 25 per person, it shows that average extraction rate of facial outline is 98.1% and average processing time is 0.2sec.

  • PDF

Effects of a Ventilator-associated Pneumonia Prevention Program on Incidence Rate and Endotracheal Colonization (인공호흡기 관련 폐렴 예방 프로그램이 폐렴 발생률과 기관내 균집락화에 미치는 효과)

  • Song, Ui Rim;Kim, Sook Young
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.6
    • /
    • pp.628-636
    • /
    • 2016
  • Purpose: This study examined the effects of a program designed to prevent ventilator-associated pneumonia (VAP) on VAP rate and endotracheal colonization. The program focused on aspiration prevention and oral care. Methods: A nonequivalent control group post-test only design was utilized. One hundred patients admitted to a medical intensive care unit (MICU) or coronary care unit (CCU) were assigned to either a experimental group (n=50) or a control group (n=50). The participants were selected 48 hours following an endotracheal intubation. VAP prevention program given to the experimental group includes keeping the head of the bed to $30^{\circ}{\sim}45^{\circ}$ high, maintaining continuous endotracheal cuff pressure at 25 cm $H_2O$, performing endotracheal suction before change position, and providing oral care with 0.1% chlorhexidine every four hours. The control group received usual care. Data were analyzed using t-test, $x^2$ test, Mantel-Haenszel $x^2$ and Cox proportional harzard regression model. Results: The experimental group showed a lower VAP rate than the control group although the difference was not statistically significant ($x^2=0.79$, p=.375). The experimental group showed lower colonization in tracheal secretion than the control group ($x^2=14.59$, p<.001). Conclusion: Results showed that a VAP prevention program is effective in reducing colonization of tracheal secretion. Therefore, VAP prevention programs are recommended as an ICU nursing intervention.

An Estimation of Head Loss Coefficients at Surcharged Manhole with 90 Degree Bend Using Numerical Model (수치모형을 이용한 과부하 $90^{\circ}$ 접합맨홀에서의 손실계수 산정)

  • Kim, Jung-Soo;Lim, Ga-Hui;Han, Chyung-Suck;Yoon, Sei-Eui
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.165-165
    • /
    • 2011
  • 현재 계획 또는 설계 단계에서 수행되고 있는 관거 시설의 수리계산에는 연결관 내에서의 마찰손실만을 감안하여 수행하고 있으며, 맨홀에서의 에너지 손실은 고려되지 않는 실정이다. 그러나 연결관 내부와 맨홀의 내부는 여러 가지 수리학적 조건이 다르므로 에너지 손실이 발생하게 된다(최원석과 송호면, 2002). 더욱이 직선으로 연결된 중간맨홀보다 유입관과 유출관이 $90^{\circ}$의 각도로 접합된 합류맨홀은 연결 구조상 유수교란에 의한 에너지 손실이 커질 것으로 예상됨에도 불구하고 현재 실무에서 우수 배수시설의 설계 시 직선 연결맨홀과 $90^{\circ}$ 접합맨홀의 손실을 구별하지 않고 사용하고 있는 실정이다. 그러므로 $90^{\circ}$ 접합맨홀에서 우수관거 시스템의 우수 배제 능력을 증가시켜 도심지의 침수를 방지하기 위한 관거시설의 적정 설계 기준이 필요하며, 합리적인 설계 기준을 제시하기 위하여 $90^{\circ}$ 접합맨홀 내에서의 수두 손실을 분석할 필요가 있다. 본 연구에서는 수리모형 실험의 물질적 및 시간적 한계를 극복하기 위하여 일반적으로 3차원 유체거동의 특성분석에 많이 사용되는 Fluent 6.3 모형을 이용하여 과부하 $90^{\circ}$ 접합맨홀에서의 흐름특성을 수치모의 하였으며, 맨홀 내 손실수두의 변화를 계산하여 손실계수를 산정하였다. 맨홀 및 접합 관거의 기하 모형의 격자망은 수치해석의 안정성 확보를 위하여 그림 1과 같이 6면체 격자로 구성하였다. 또한 $90^{\circ}$ 접합맨홀에서 급격한 와류에 의해 발생하는 에너지 손실을 저감하기 위하여 $90^{\circ}$ 접합맨홀의 내부 형상 및 접합 조건을 변화시켜 손실계수를 산정하였다. 수치모형의 적용 결과 맨홀 내에서의 유속변화, 수심변화 및 압력변화에 대해서는 수리모형 실험 결과와 유사한 경향을 나타내고 있으며, 수치모형에 의하여 산정된 $90^{\circ}$ 접합맨홀에서 에서의 손실계수 값과 수리모형에 의하여 산정된 손실계수 값이 거의 유사하게 나타났다.

  • PDF

Effect of Dietary Fat on Structure and Function of Mammalian Cell Membrane (식이지방이 생체막 구조와 기능에 미치는 영향)

  • Cho, Sung-Hee
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.13 no.4
    • /
    • pp.459-468
    • /
    • 1984
  • The currently accepted model of membrane structure proposes a dynamic, asymmetric lipid matrix of phospholipids and cholesterol with globular proteins embedded across the membrane to various degrees. Most phospholipids are in the bilayer arrangement and also closely associated with integral membrane proteins or loosely associated with peripheral proteins. Biological functions of membrane, such as membrane-bound enzyme functions and transport systems, are influenced by the membrane physical properties, which are determined by fatty acid composition of phospholipids, polar head group composition and membrane cholesterol content. Polar and non-polar region of the phospholipid molecule can interact, with changes in the conformation of a membrane-associated protein altering either its catalytic activity or the protein's interaction with other membrane proteins. Mammalian dietary studies attempted to change the lipid composition of a few cell membranes have shown comparisons, using essential fatty acid-deficient diets. In recent years, Clandinin and a few other workers have pioneered the study proving the influence of dietary fat fed in a nutritionally complete diet on composition of phospholipid classes of cell membrane. Modulation caused by diet fat was rapid and reversible in phospholipid fatty acyl composition of membranes of cardiac mitochondria, liver cell, brain synaptosome and lymphocytes. These changes were at the same time, accompanied by variety of membrane associated functions controlled by membrane-bound enzymes, tranporter and receptor proteins. The findings suggest the basic concept of the necessity of dietary fatty acid balance if consistency of optimal membrane structural lipid composition is to be maintained, as well as the overall inadequacy of describing the nutritional-biochemical quality of a dietary fat solely by its content of linoleic acid. Furthermore, they give light on the possible application to clinical and preventive medicine.

  • PDF

Assessment of Factors Associated with the Safety Depth of GV15 Yamen -Factors Associated with the Safety Depth of GV15-

  • Park, Soo-Jung;Jin, Ming;Joo, Jong-Cheon;Kwon, Young-Mi
    • Journal of Pharmacopuncture
    • /
    • v.17 no.1
    • /
    • pp.70-73
    • /
    • 2014
  • Objectives: Yamen is the fifteenth acupoint of the Governor Vessel Meridian (GV15). It is anatomically close to the medulla oblongata, so finding the safety depth of the acupoint is very important. However, few studies on the safety depth of GV15 have been done. Methods: This study tried to measure the safety depth of GV15 by using magnetic resonance imaging (MRI) scans and to analyze the factors affecting the safety depth through multiple regression analyses. This study was carried out for patients who had a brain MRI scan while visiting Jeonju Wonkwang Hospital, Korea. The shortest distance between the glabella and the occipital protuberance (DGO), the horizontal distance between the glabella and the back of the head (DGB) and the dangerous depth (DD) were measured from the sagittal views of the MRI images. The DD is the horizontal distance from the skin's surface at GV15 to the spinal dura mater. Results: The model suggested that the safety depth (SD) was significantly associated with gender (${\beta}$ = 0.474, P < 0.0001), DGO (${\beta}$ = 0.272, P = 0.027), and BMI (${\beta}$ = 0.249, P = 0.005) and the combination of three variables can explain the SD, with $R^2$ = 0.571 (Table 3). A longer SD was associated with males and with greater BMI and DGO. Conclusion: This study suggests that gender, BMI and DGO may be important factors when the SD of GV15 is considered clinically through a multiple regression analysis of GV15.

A Study on Changes in Biomechanical Characteristics of the Foot with Respect to Wedge-type Insole Thickness (키높이 인솔두께에 따른 족부의 생체역학적 특성변화에 대한 연구)

  • Park, T.H.;Jung, T.G.;Han, D.W.;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.80-90
    • /
    • 2013
  • Recently, functional insoles of wedge-type it is for the young to raise their height inserted between insole and heel cause foot pain and disease. Additionally, these have a problem with stability and excessively load-bearing during gait like high-heel shoes. In this study, we compared the changes in biomechanical characteristics of foot with different insole thickness then we will utilize for the development of the insole with the purpose of relieving the pain and disease. Subjects(male, n = 6) measured COP(center of pressure) and PCP(peak contact pressure) on the treadmill(140cm/s) using F-scan system and different insole thickness(0~50 mm) between sole and plantar surface during gait. Also, we computed changes of stresses at the foot using finite element model with various insole thickness during toe-off phase. COP moved anterior and medial direction and, PCP was increased at medial forefoot surface, $1^{st}$ and $2^{nd}$ metatarsophalangeal, ($9%{\uparrow}$) with thicker insoles and it was show sensitive increment as the insole thickness was increased from 40 mm to 50 mm. Change of the stress at the soft-tissue of plantar surface, $1^{st}$ metatarsal head represents rapid growth($36%{\uparrow}$). Also, lateral moments were increased over the 100% near the $1^{st}$ metatarsal as the insole thickness was increased from 0 mm to 30 mm. And it is show sensitive increment as the insole thickness changed 10 mm to 20 mm. As a result, it was expected that use of excessively thick insoles might cause unwanted foot pain at the forefoot region. Therefore, insole thickness under 30 mm was selected.

Design of a low frequency, high power acoustic transducer to use in the echo sounder (어군탐지기용 저주파.고출력 음향 변환기의 설계)

  • 이대재
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • A low frequency, high power hydroacoustic transducer with 7 tonpilz piston elements assembled in a circular array suitable for marine application, such as the transmission of underwater information and the development of new fisheries resources in the deep sea zone was designed. A modified Mason's model was applied to monitor and to simulate the transducer behavior at each step during the fabrication. The in air, and in water constructed tonpilz transducer was tested experimentally and numerically by changing the size and the type of the material for head, tail and acoustic window. Also, the developed transducer was excited by pulse signals and the received waveform was analyzed. The resonance peaks in the transmitting voltage response(TVR) of a single tonpilz element without housing were observed at 11.33kHz in air and 10.93kHz in air and 10.93 kHz in water, respectively, with the overall electrical-acoustic efficiency of 43.7%. The value of TVR of single tonpilz element with aluminum housing in water was 129.87dB re 1 $\mu$Pa/V at 12.25 kHz with the frequency bandwith of 2.15 kHz and half beam angle of 30.2$^{\circ}$at -3dB.The resonance peaks in the transmitting voltage response of the 7 element circular transducer were observed at 11.50 kHz in air and 11.45 kHz in water, respectively. The value of TVR in water 144.84 dB re 1$\mu$Pa/V at 11.5kHz with the frequency bandwith of 4.25 kHz and the half beam angle of $22.3^{\circ} $ at -3dB.Reasonable agreement between the experimental measurements and the theoretical predictions for the directivity patterns, TVRs and the impedance characteristics of the designed transducer was achieved.

  • PDF

Application Effects of Chitosan Fertilizer on the Growth of Cabbage and GABA Contents in the Cabbage (배추의 생장 및 배추 중의 ${\gamma}-aminobutyric$ acid 함량에 미치는 키토산비료의 시비효과)

  • Seo, Kyung-Won;Choi, Dong-Seong;Han, Kwang-Soo;Choi, Won-Gyu;Oh, Suk-Heung
    • Applied Biological Chemistry
    • /
    • v.43 no.1
    • /
    • pp.34-38
    • /
    • 2000
  • To investigate the effects of chitosan on growth and quality improvement of vegetables, we utilized cabbage as a model plant system and SL-chitosan as a chitosan fertilizer. The chitosan fertilizer treatment increased the leaf lengths of cabbage seedlings compared with those of control groups. In addition, the content of ${\gamma}-aminobutyric$ acid (GABA) in the fertilizer-treated cabbage seedlings was higher than that in the control group. Peripheral lengths and head weights of cabbages along with their GABA contents were also measured during the growth of cabbages in field. The fertilizer treatment, without changing the physico-chemical properties of main field soil after the cultivation of cabbage, significantly increased the peripheral length, average weight and GABA content compared with control treatment. These results may suggest that the quality and quantity of cabbage can be improved by chitosan treatments.

  • PDF

Dual Stage Actuator System for High Density Magnetic Disk Drives Using a Rotary-type Electrostatic Microatuator (회전구동 정전형 마이크로 액추에이터를 이용한 고트랙밀도 HDD용 이단 구동 시스템)

  • Jung Sunghwan;Choi Jae-Joon;Park Jihwang;Lee Chang-Ho;Kim Cheol-Soon;Min Dong-Ki;Kim Young-Hoon;Lee Seung-Hi;Jeon Jong Up
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.10 s.175
    • /
    • pp.174-185
    • /
    • 2005
  • This paper presents the design, fabrication, and testing results of a dual stage actuator system for a fine positioning of magnetic heads in magnetic disk drives. A novel rotary microactuator which is electrostatically driven and utilized as a secondary actuator was designed. The stator and rotor electrodes in the microactuator was revised to have the optimal shapes and hence produces much higher rotational torque compared with the conventional comb-shape electrodes. The microactuators were successfully fabricated using SoG(silicon on glass) processing technology, which is known as being cost-effective. The fabricated microactuator has the structural thickness of $45{\mu}m$ with the gap width of approximately $3{\mu}m$. The dynamic characteristic of microactuator/slider assembly was investigated, and its natural frequency and DC gain were measured to be 3.4kHz and 32nm/V, respectively. The microactuator/slider assembly was integrated into a HDD model V10 of Samsung Electronics Co. and a dual servo algorithm was tested to explore the tracking performance of dual stage actuator system where the LDV signals instead of magnetic head signals were used. Experimental results indicate that this system achieves the tracking accuracy of 30nm. This value corresponds to a track density of 85,000 track per inch(TPI), which is about 3 times greater than that of current hard disk drives.