• Title/Summary/Keyword: head measurements

Search Result 477, Processing Time 0.026 seconds

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

Measurement of Skull Size on Computed Tomography Images for Developing a Bone Conduction Headset Suitable for the Korean Standard Head Size

  • Ku, Cheol Hyo;Kim, Soo Won;Kim, Ji Young;Paik, Seung Won;Yang, Hui Joon;Lee, Ji Hyeon;Seo, Young Joon
    • Korean Journal of Audiology
    • /
    • v.24 no.1
    • /
    • pp.17-23
    • /
    • 2020
  • Background and Objectives: We aimed to measure the head dimensions on computed tomography (CT) images, to compare them to directly measured head dimensions, and to predict a new parameter of bone thickness for aiding bone conduction implant (BCI) placement. Subjects and Methods: We reviewed the facial and mandibular bone CT images of 406 patients. Their head sizes were analyzed using five parameters included in the 6th Size Korea project, and they were divided into age groups (ranging from the 10s to the 80s). We compared the head length, head width, sagittal arc, bitragion arc, and head circumference in the CT and Size Korea groups. We also added the parameter bone thickness for aiding BCI placement. Results: All the head size parameters measured using CT were significantly smaller than those measured directly, with head length showing the smallest difference at 7.85 mm. The differences in the other four parameters between the two groups according to patient age were not statistically significantly different. Bone thickness had the highest value of 4.89±0.93 mm in the 70s and the lowest value of 4.10±0.99 mm in the 10s. Bone thickness also significantly correlated with head width (p=0.038). Conclusions: Our findings suggested that the CT and direct measurements yielded consistent data. Moreover, CT enabled the measurement of bone sizes, including bone thickness, that are impossible to measure directly. CT measurements may complement direct measurements in the Size Korea data when used for developing bone conduction hearing devices (BCIs and headsets) for the Korean population.

The Validity of Head Posture Aligner in Posteroanterior Cephalometry (정모 두부 방사선 사진 촬영시 Head Posture Aligner의 유용성에 관한 연구)

  • Kim, Eun-Hee;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.30 no.5 s.82
    • /
    • pp.543-552
    • /
    • 2000
  • The purposes of this study were to evaluate the reproducibility of posteroanterior(PA) cephalograms obtained by two methods, the Head Posture Aligner(HPA) method in natural head posture and the conventional method(operator-guided method), and to compare the vertical rotational differences of the head Posture between lateral and PA cephalograms according to the method. The sample was consisted of 30 adults. At first day, a PA cephalogram and a lateral cephalogram were obtained from each subject by two methods to investigate the difference of vertical rotational posture between lateral and PA cephalograms. Two weeks later, another PA cephalogram was obtained using each method to evaluate the reproducibility of head posture. Five height measurements and nine width measurements were used in the paired t-test to compare the reproducibility of the PA cephalometric measurements between two methods. The differences of vertical rotational posture between lateral and PA cephalograms were calculated from a computer program and compared according to the method used, and following results were obtained. 1. Height measurements obtained by operator-guided method showed significant differences according to the time interval and revealed low reproducibility. 2. Height measurements obtained by HPA method did not show significant differences according to the time interval and presented high reproducibility. 3. In the comparison of width measurement, two methods did not show distinct differences in reproducibility. 4. The difference of vertical rotational posture between lateral and PA cephalograms showed $0.8^{\circ}$ in the HPA method, more less than $2.5^{\circ}$ in the operator-guided method. The results of the present study suggest that the HPA may be helpful in the PA cephalometric radiography in terms of reproducibility.

  • PDF

Intra-Rater and Inter-Rater Reliability of Various Forward Head Posture Measurements

  • Yoo, Won-Gyu;Kim, Min-Hee;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.12 no.4
    • /
    • pp.41-47
    • /
    • 2005
  • The purpose of this study was to determine the intra-rater and inter-rater reliability of various forward head posture measurements. Ten healthy adults (age, $20.4{\pm}2.2$ yrs; height, $164.0{\pm}5.5$ cm; weight, $58.7{\pm}7.3$ kg) participated in the study. They were free of injury and neurologic deficits in the upper extremities and neck at the time of testing. The subjects were asked to perform head forward posture by under the guidance of physical therapists. Markers were placed on the C7 spinous process, mastoid process, tragus of the ear, outer canthus, and forehead. Measurement 1 for forward head posture assessment was measured as the angle between the horizontal line through C7 and the line connecting the C7 spinous process with the tragus of the ear. Measurement 2 was measured as the angle between the C7 spinous process, the mastoid process and the outer canthus. Measurement 3 was measured as two kinds of angles the HT (head tilt) angle is between the line from the midpoint of forehead to the tragus line and Y-axis at the tragus point. The NF (neck flexion) angle is between the line from the tragus to the C7 line and the Y-axis at the C7. Intra-rater, inter-rater reliability and coefficient of variation was assessed by comparing the measured values from three kinds of measurements of forward head posture. The intra-rater reliability was indicated by intraclass correlation coefficients [ICC(1,1)] and inter-rater reliability was shown by intraclass correlation coefficients [ICC(3,k)]. The results of study were as follows: ICC(1,1) values for intra-rater reliability of three measurements were in the 'excellent' category. ICC(3,k) values for inter-rater reliability of three measurements were also in the 'excellent' category. The coefficient of variation of method 2 had a lower value than method 1 and method 3. This data means that the measured value of method 2 was less scattered. Further research is needed to determine whether the validity of all measurements is revealed in the 'excellent' category.

  • PDF

Effects of Deep Cervical Flexors Strengthening Exercise on Cervical-Shoulder Angle, Disability index and pain and in Patients with Chronic Neck Pain (깊은목굽힘근 강화운동이 만성 목통증 환자의 통증과 목-어깨각도, 장애지수 및 통증에 미치는 영향)

  • Kim, Jin-young
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.21 no.2
    • /
    • pp.33-37
    • /
    • 2015
  • Background: The purpose of this study on the effects of deep cervical flexors strengthening exercise to forward head posture and pain of neck in patients with chronic neck pain. Method: We selected 30 subjects among neck pain patients and carried out measurements. The subjects' forward head posture was measured including head tilt angle (HTA), neck flexion angle (NFA) and forward shoulder angle (FSA), neck disability index (NDI), numeric rating scale (NRS). The subjects underwent deep cervical flexors muscle strengthening with pressure bio-feedback device for 4 weeks. Then, after intervention, the subjects' forward head posture was measured again. It was performed Wilcoxon signed-ranks test for confirming the effect of deep cervical flexor muscles strengthening exercise. Results: As a result of comparison of measurements before and after intervention, we found that there were statistically significant improvement in the subjects' NDI, NRS and forward head posture including head tilt angle, neck flexion angle and forward shoulder angle. Conclusion: We concluded that deep cervical flexors strengthening exercise has the effect of alleviation of neck pain patients and is effective for forward head posture.

  • PDF

Effects of Angular Velocity Components on Head Vibration Measurements (각속도 성분들이 머리진동 측정치에 미치는 영향)

  • Park Yong Hwa;Cheung Wan Sup
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.1E
    • /
    • pp.7-15
    • /
    • 2005
  • This paper addresses issues encountered in measuring the general, 6-degree-of-freedom motion of a human head, A complete mathematical description for measuring the head motion using the six-accelerometer configured bite-bar is suggested, The description shows that the six-axis vibration cannot be completely obtained without the roll, pitch and yaw angular velocity components, A new method of estimating the three orthogonal (roll, pitch and yaw) angular velocities from the six acceleration measurements is introduced. The estimated angular velocities are shown to enable further quantitative error analysis in measuring the translational and angular accelerations at the head. To make this point clear, experimental results are also illustrated in this paper. They show that when the effects of angular velocities are neglected in the head vibration measurement the maximum percentage errors were observed to be more than $3 \%$ for the angular acceleration of the head and to be close to $5 \%$ for its translational acceleration, respectively. It means that the inclusion of all the angular velocity dependent acceleration components gives more accurate measurement of the head vibration.

Vibration Behavior and Dynamic Stress of Runners of Very High Head Reversible Pump-turbines

  • Tanaka, Hiroshi
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.289-306
    • /
    • 2011
  • In the development of very high head pumped storage projects, one of the critical problems is the strength of pumpturbine runners. Data obtained by stress measurements of high head pump-turbine runners indicated that dynamic stress due to the vibration of runner might be detrimental, possibly to cause fatigue failure, if the runner were designed without proper consideration on its dynamic behaviour. Numerous field stress measurements of runners and model tests conducted with hydrodynamic similarity revealed that the hydraulic excitation force developed by the interference of rotating runner blades with guide vane wakes sometimes would induce such heavy vibration of runner. Theoretical and experimental investigations on both the hydraulic excitation force and the natural frequencies of runner have been conducted to explore this forced vibration problem.

A Study on the Sizing System of Head Wears According to the Head Types (머리의 형태별 특성에 따른 모자류 치수체계 연구)

  • Lim Jiyoung
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.1 s.203
    • /
    • pp.105-113
    • /
    • 2005
  • The purpose of this study was to suggest a standard sizing system for college female students' head wears according to their head types. The subjects were 193 college women, of 20 to 25 years-old. The subjects were directly measured anthropometrically and indirectly analyzed photographically. In previous tudy (Lim, 2004), 3 clusters as their head types were categorized. the sizing system, which had frequencies more than $4\%$ was classified 6 cases, 7 cases and 9 cases, respectively, by head 3 types. 3 types of size system, which were 56-28-38, 56-30-38 and 57-28-38(Eds note: which of the measurements are head girth, surface length 1 and surface length 2), which were included in 3 clusters. Although head girths were as the same, head surface length was different in size. On the contrary, head surface length was same, head girth was different. The result will contribute to fitness of head wear fitness of consumer, and the amount of production.

Establishment of prediction table of parturition day by ultrasonography in Korean Jindo bitches (진도개에서 초음파검사에 의한 분만일 예정표 확립)

  • Kim, Se-ra;Kang, Hyun-gu;Oh, Ki-seok;Park, In-chul;Park, Sang-guk;Kim, Sung-ho;Son, Chang-ho
    • Korean Journal of Veterinary Research
    • /
    • v.40 no.2
    • /
    • pp.373-381
    • /
    • 2000
  • Serial ultrasonographic examinations were performed on pregnant Korean Jindo bitches. Measurements of inner chorionic cavity diameter and fetal head diameter were made from pregnancy day 15 to parturition. These measurements were converted retrospectively based on the day of parturition (day 0). The data of inner chorionic cavity diameter obtained from day -42 to day -25 and fetal head diameter obtained from day -24 to day -1 were used to prediction of parturition day. Formulas for the prediction of parturition day using the method of least squares were derived. These formulas were then used to predict parturition dates based on single measurements of inner chorionic cavity diameter or fetal head diameter in 17 additional pregnant Korean Jindo bitches. Predicted date of parturition was then compared to actual whelping date. In the prediction of parturition based on inner chorionic cavity diameter, 7 of 10 bitches were coincided prediction date and actual whelping date, and the prediction was accurate to within 1 day in 3 of 10 bitches. The prediction of parturition based on fetal head diameter was accurate to within 1 day in 6 of 7 bitches and within 2 days in 1 of 7 bitches. In conclusion, the ultrasound measurement of inner chorionic cavity diameter and fetal head diameter are practical and accurate tool in the prediction of parturition.

  • PDF

Anthropometric study of the head for the development of firefighting hoods for firefighters (소방공무원의 방화두건 제작을 위한 머리 치수 연구)

  • Jeong, Da Wun;Jang, Mina;Kwon, Chae-Ryung;Kim, Dong-Eun;Lee, In Seong
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.5
    • /
    • pp.670-681
    • /
    • 2017
  • Firefighting hoods protect the head, face, and neck areas of officials while they perform firefighting services. The purpose of this study is to investigate the head size of Korean firefighting officials in order to establish the dimensions necessary to construct firefighting hoods. A total of 98 male firefighting officials participated in this study and 11 body dimensions, necessary for the construction of firefighting hoods, were measured. The data collected from the firefighting officials were compared to the general adult male data from the Size Korea national anthropometric study. The heights, weights, head circumferences, head heights, and bitragion arcs of the firefighters were significantly larger than those of general adult males, which shows that firefighting officials generally have larger body and head sizes than general adult males. Based on the results of Pearson's correlation coefficients, head circumference and head height were judged to be the important measurements for the construction of the firefighting hoods. Thus, these two measurements were chosen as the basic dimensions of the cross tabulation analysis. As a result, head circumferences of 57.00~60.99cm and head heights of 23.00~25.99 cm were found to be important measurement ranges among the firefighters. This study is expected to be used as the basis for the creation of firefighting hoods that help to ensure the safe rescue activities for firefighting officials.