Air Plooutin Aspects of Hazardous Waste Incineration and Control Starategies (유해폐기물소각의 대기오염 관련성 및 제어대책)

  • Dong, Jong-In
    • Applied Chemistry for Engineering
    • /
    • v.3 no.2
    • /
    • pp.207-212
    • /
    • 1992
  • Main disposal technology for industrial wasites in Korea has been landfilling, however, this is encountering serious problems such as the lack of landfill sites and objections of residents. Incineration, therefore, has become a final solution for this dilema. Various kinds of air pollutants generation are possible because of the variety of types and compositions of wastes generated in industry. In this paper, air pollutants produced while incinerating hazardous industrial wastes are discussed and some control technologies are surveryed with the purpose of optimal design of incinerators and emission reduction. From this initial stage of incinerator utilization, low-emission type should be developed and applied and intensive research on pollutant generation due to waste incineration and advanced control technologies should be also performed.

  • PDF

Applying a GIS to Solid and Hazardous Waste Disposal Site Selection (쓰레기매립장 부지선정을 위한 GIS 활용연구)

  • 김윤종;김원영;유일현;백종학;이현우;류중희
    • Korean Journal of Remote Sensing
    • /
    • v.6 no.2
    • /
    • pp.135-151
    • /
    • 1990
  • Solid and hazardous waste disposal site selection by using GIS(Geographic Information System) is the purpose of this study. The criteria of site selection are usually defined in accordance with geological, cultural and social characteristics. Unadequate adaptation of these criteria in a site selection may cause serious problem of water and soil pollution. The environmental information for extraction of these criteria consist of a lot of data : geology, geomorphology, hydrogeology, engineering geology, cultural and social information.... GIS could be easily applied to construct of this environmental information data base, and carry out cartography simulation using overlay mapping technique(polygon overlay). ARC/INFO(GIS system) was used for these studies, and AML(ARC/INFO Macro Language) in this system provided more variable and effective methods for cartography simulation. TM(Thematic Mapper) images were used for the evaluation of land cover/use in the studied area, by using ERDAS image processing system.

Glass Property Models, Constraints, and Formulation Approaches for Vitrification of High-Level Nuclear Wastes at the US Hanford Site

  • Kim, Dongsang
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.2
    • /
    • pp.92-102
    • /
    • 2015
  • Current plans for legacy nuclear wastes stored in underground tanks at the U.S. Department of Energy's Hanford Site in Washington are that they will be separated into high-level waste and low-activity waste fractions that will be vitrified separately. Formulating optimized glass compositions that maximize the waste loading in glass is critical for successful and economical treatment and immobilization of these nuclear wastes. Glass property-composition models have been developed and applied to formulate glass compositions for various objectives for the past several decades. Property models with associated uncertainties combined with composition and property constraints have been used to develop preliminary glass formulation algorithms designed for vitrification process control and waste-form qualification at the planned waste vitrification plant. This paper provides an overview of the current status of glass property-composition models, constraints applicable to Hanford waste vitrification, and glass formulation approaches that have been developed for vitrification of hazardous and highly radioactive wastes stored at the Hanford Site.

Characteristics of Hazardous Air Pollutant Emissions from Waste Incinerators (폐기물소각시설의 유해대기오염물질 배출특성 연구)

  • Park, J.M.;Lee, S.B.;Kang, J.G.;Kim, J.P.;Choi, E.S.;Hwang, W.G.;Kwon, O.S.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.2
    • /
    • pp.183-190
    • /
    • 2007
  • In this study, we have investigated waste incinerators which are one of the major HAPs emission sources. In order to obtain more reliable HAPs emission data from waste incinerators, direct sampling for the possible pollutants from the stack was carried out and the analysis was performed. The purpose of study was to understand the emission status from waste incinerators and recognize the problems and finally to set up a strategy to reduce the HAPs emissions from waste incinerators. The emission concentrations of 8 species of heavy metals and 16 species of PAHs have been analyzed for the first time in Korea. Not only the emission characteristics of HAPs from waste incinerators were identified, but also the analysis of reduction efficiencies for control devices such as BF and wet scrubbing systems was carried out.

The PVC Membrane Electrode for Measuring Hazardous Anion in Waste Water Process (폐수처리 공정중 유해음이온을 측정하기 위한 PVC 막 전극)

  • Woo, In-Sung;An, Hyung-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.4
    • /
    • pp.47-59
    • /
    • 1995
  • The perchlorate, thiocyanate, and nitrate ion-selective PVC membrance electrode for measuring hazardous anion in waste water were developed by incorporating the quaternary ammonium salts as active material. Ion-selective characteristics in waste water were studied by the useful pH range, the selective coefficients to various interfering anions, and the stability of electrode potential. DBP was best as a plasticizer. The effect of the membrane thickness on the electrode characteristics was improved with decreasing the membrane thickness, but below the optimum membrane thickness the electrode exhibited an inverse trend. The electrode potential of perchlorate, thiocyanate, and nitrate electrode with TDDA, as active material, was stable within the pH range 4-11, 3-12, and 4-10 repectively. And the long-term potential stability of these electrodes were 3.0, 3.5, and 3.5 months respectively. The order of the selectivity coefficients was as shown below ; $ClO_4{^-}$ > $SCN^-$ > $I^-$ > $NO_3{^-}$ > $Br^-$ > $CN^-$ > $F^-$ > $Cl^-$ > $Ac^-$ > $H_2PO_4{^-}$, $SO_4{^-}$.

  • PDF

Ignition and flame propagation in hydrogen-air layers from a geological nuclear waste repository: A preliminary study

  • Ryu, Je Ir;Woo, Seung Min;Lee, Manseok;Yoon, Hyun Chul
    • Nuclear Engineering and Technology
    • /
    • v.54 no.1
    • /
    • pp.130-137
    • /
    • 2022
  • In the geological repository of radioactive nuclear waste, anaerobic corrosion can generate hydrogen, and may conservatively lead to the production of hydrogen-air layer. The accumulated hydrogen may cause a hazardous flame propagation resulting from any potential ignition sources. This study numerically investigates the processes of ignition and flame propagation in the layered mixture. Simple geometry was chosen to represent the geological repository, and reactive flow simulations were performed with different ignition power, energy, and locations. The simulation results revealed the effects of power and energy of ignition source, which were also analyzed theoretically. The mechanism of layered flame propagation was suggested, which includes three stages: propagation into the hydrogen area, downward propagation due to the product gas, and horizontal propagation along the top wall. To investigate the effect of the ignition source location, simulations with eight different positions were performed, and the boundary of hazardous ignition area was identified. The simulation results were also explained through scaling analysis. This study evaluates the potential risk of the accumulated hydrogen in geological repository, and illustrates the layered flame propagation in related ignition scenarios.

A Case Study on Operation of Off-Gas Treatment System of Radioactive Waste Vitrification Facility (방사성폐기물 유리화설비의 배기가스 처리계통 운영 사례 연구)

  • Lee, Hye Hyun;Park, Kyu Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.5
    • /
    • pp.249-254
    • /
    • 2016
  • In this study, we investigated the main characteristics of off-gas generated from melting process and off-gas treatment system operation example to provide some primary data for commercial vitrification facility design. The purpose of vitrification facility operation is to treat hazardous materials in the radioactive wastes and harmful off-gas containing a variety of chemical species generated in the glass melting process. Constructing and operating vitrification facility essentially need to be licensed through safety analysis; it is very important to treat radionuclide and hazardous materials below the legal environment emissions regulation level. We must accurately understand the characteristics of off-gas and apply an appropriate off-gas treatment process accordingly. Thus, to design the appropriate off-gas treatment there must be a wide range of elements taken into account such as characteristics of waste and melter, regulation guidance of off-gas, characteristics of generated off-gas and off-gas treatment system performance assessment.

Mercury Exposure among Garbage Workers in Southern Thailand

  • Decharat, Somsiri
    • Safety and Health at Work
    • /
    • v.3 no.4
    • /
    • pp.268-277
    • /
    • 2012
  • Objectives: 1) To determine mercury levels in urine samples from garbage workers in Southern Thailand, and 2) to describe the association between work characteristics, work positions, behavioral factors, and acute symptoms; and levels of mercury in urine samples. Methods: A case-control study was conducted by interviewing 60 workers in 5 hazardous-waste-management factories, and 60 matched non-exposed persons living in the same area of Southern Thailand. Urine samples were collected to determine mercury levels by cold-vapor atomic absorption spectrometer mercury analyzer. Results: The hazardous-waste workers' urinary mercury levels (10.07 ${\mu}g/g$ creatinine) were significantly higher than the control group (1.33 ${\mu}g/g$ creatinine) (p < 0.001). Work position, duration of work, personal protective equipment (PPE), and personal hygiene, were significantly associated with urinary mercury level (p < 0.001). The workers developed acute symptoms - of head-aches, nausea, chest tightness, fatigue, and loss of consciousness at least once a week - and those who developed symptoms had significantly higher urinary mercury levels than those who did not, at p < 0.05. A multiple regression model was constructed. Significant predictors of urinary mercury levels included hours worked per day, days worked per week, duration of work (years), work position, use of PPE (mask, trousers, and gloves), and personal hygiene behavior (ate snacks or drank water at work, washed hands before lunch, and washed hands after work). Conclusion: Changing garbage workers' hygiene habits can reduce urinary mercury levels. Personal hygiene is important, and should be stressed in education programs. Employers should institute engineering controls to reduce urinary mercury levels among garbage workers.

Physicochemical Properties of Landfill Mined Wastes from Old Landfill Site (불량 매립지에서 굴착된 폐기물의 물리화학적 특성평가)

  • 남궁완;이노섭;박준석;인병훈
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.99-108
    • /
    • 2002
  • This study was carried out to evaluate the Physicochemical characteristics of mined waste(separated waste and soil) and to predict environmental effect of an old landfill site located at north of Seoul. Municipal solid waster(MSW) had been disposed of at the old landfill site used in this study for about 2 years(1990-1992). The old landfill site selected for this study had accepted mainly municipal solid waste. The landfill-mined waste contained separated waste (40.9%) and soil(59.1%) by wet weight basis. The separated waste consisted of combustible(91.0%) and non-combustible(9.0%). The combustible waste was mainly non-biodegradable plastics. The low heating value of the separated combustible waste, which is calculated by Dulong's equation, was as high as 3,470kcal/kg. According to the Korean Extraction Procedure, separated waste and soil were proved to be not hazardous. The total content of heavy metal in the separated waste and soil met standard of California State, USA. Therefore the separated waste may be relandfilled at a sanitary landfill site and/or burned up at an incinerator, and the separated old soil may be used ad landfill cover-soil at a sanitary landfill site. Water quality of two streams was grade IV, of which water could be used as industrial and agricultural water. The streams near the landfill site might not be contaminated by leachate from the old landfill site. It was estimated that organic matter in the old landfill site would not be actively biodegraded within a short period of time.