• Title/Summary/Keyword: hazardous material

Search Result 327, Processing Time 0.024 seconds

Chemical Composition and Heavy Metal Contents in Commercial Liquid Pig Manures (국내유통 돈분액비의 화학성 및 중금속 함량)

  • Lee, Ji-Ho;Go, Woo-Ri;Kunhikrishnan, Anitha;Yoo, Ji-Hyock;Kim, Ji-Young;Kim, Won-Il
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.1085-1088
    • /
    • 2011
  • Heavy metal concentration as well as chemical composition were surveyed in commercial liquid pig manure to provide the basic information for mitigation research of hazardous material to agro-product. Seventy-five samples of liquid pig manure were collected and analyzed from 2009 to 2010 nationwide. Average contents of T-N, $P_2O_5$, and $K_2O$ were 0.29%, 0.08%, and 0.11%, respectively. The contents of heavy metals ranged from 0.001~0.083 for As, 0.001~0.108 for Cd, 0.002~0.495 for Cr, 0.07~47.8 for Cu, ND~0.005 for Hg, 0.035~1.033 for Ni, ND~0.291 for Pb, and $0.75{\sim}342.4mg\;L^{-1}$ for Zn, respectively. It was noted that among 75 samples, only four samples exceeded the Zn guideline ($130mg\;L^{-1}$) of liquid fertilizer derived from livestock manure but others were not exceeded the regulation.

A Study on the Spatial Position Problem of PM Monitoring Stations Using Voronoi Technique and Density Analysis (보로노이 기법과 밀도분석을 활용한 미세먼지 측정소 공간적 위치 문제 연구)

  • Jeong, Jong-Chul
    • Journal of Cadastre & Land InformatiX
    • /
    • v.48 no.2
    • /
    • pp.185-195
    • /
    • 2018
  • In the Seoul Metropolitan City, the PM(pariculate matter) application used by the citizens provides the PM concentration of the nearest monitoring stations located on the PM monitoring stations. Currently, the selecting method of the PM monitoring network considered by the Ministry of Environment is based on considering the monitoring station distribution and population density only. In this study, we analyzed the distance between PM monitoring station and the administrative center point in addition to the above considerations. The number of test sites was verified and the range of coverage of each monitoring stations was indicated by using the Voronoi algorithm and hexagon grid. The spatial position problem of the PM monitoring station was suggested by spatial data analysis. The variables of spatial data analysis are single-family houses, apartments, $1^{st}$ class neighborhood, $2^{nd}$ class neighborhood, garbage disposal plant, hazardous material disposal facility, factory, and the density map. The analysis result of the selection criterion considering the additional variables for new PM monitoring stations was presented, in addition to the selection criteria provided by the Ministry of Environment.

A Study on the Application of Digital Twin Technology for Container Terminals (컨테이너 터미널의 디지털 트윈 기술 적용에 관한 연구)

  • Choi, Hoon-Do;Yu, Jang-Ho
    • Journal of Navigation and Port Research
    • /
    • v.44 no.6
    • /
    • pp.557-563
    • /
    • 2020
  • Digital Twin Technology is currently being utilized in many industries and logistics seems soon to follow that trend. Currently, technology introduction to container terminals is restrictedly developing. In reviewing the existing literature, it became clear that research on the application of Digital Twin technology for container terminals is deficient. This study fulfilled AHP and IPA analysis causing fields to adjust priority at the container terminal. The result of analysis on the urgent necessity of adjustable fields' detailed elements from Digital Twin Technology, ATC, intelligent CCTV, and container yards, and showed that they were of the highest priority level. Also, VR/AR Equipment, AYT, Smart Container, Automated Container Delivery Facility, Refrigerated/Freezer Container, Wearable Device for Port Maintenance, and Smart Buoy were reviewed in detail. Our group suggests AQC, Berth, AGV, ASC, Apron, and Automated Mooring as potentially useful Digital Twin Technologies. Finally, our research suggests the OSS equipment, intermodal linkage facility, intelligent drone, and hazardous material storage are areas of low priority.

Adsorption Characteristics of Uranium (VI) Ion on OenNdien Resin with Styrene Hazardous Material (스타이렌 위험물을 포함한 OenNdien 수지에 의한 우라늄(VI) 이온의 흡착 특성)

  • Kim, Joon-Tae
    • Applied Chemistry for Engineering
    • /
    • v.22 no.6
    • /
    • pp.697-702
    • /
    • 2011
  • Ion exchange resins have been synthesized from chloromethylated styrene-1,4-divinylbenzene (DVB) with 1%, 2%, 5% and 15%-crosslinkage and macrocyclic ligand of $OenNdien-H_4$ by copolymerization. The adsorption characteristics of uranium (${UO_2}^{2+}$), potassium ($K^+$) and neodymium ($Nd^{3+}$) metallic ions have been investigated. The synthesis of these resins was confirmed by content of chlorine, element analysis, and IR-spectrum. The effects of pH, time, and crosslinkage on adsorption of metallic ions were also studied. The uranium ion showed the fast adsorption on the resins above pH 3. The optimum equilibrium time for the adsorption of metallic ions was about two hours. The adsorption selectivity determined in methanol solution was in increasing order uranium (${UO_2}^{2+}$) > potassium ($K^+$) > neodymium ($Nd^{3+}$) ion. Moreover, the adsorption was increased with the crosslinkage concentration in order of 1%, 2%, 5% and 15%-crosslinkage resin.

Fault Detection Method for Multivariate Process using ICA (독립성분분석을 이용한 다변량 공정에서의 고장탐지 방법)

  • Jung, Seunghwan;Kim, Minseok;Lee, Hansoo;Kim, Jonggeun;Kim, Sungshin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.2
    • /
    • pp.192-197
    • /
    • 2020
  • Multivariate processes, such as large scale power plants or chemical processes are operated in very hazardous environment, which can lead to significant human and material losses if a fault occurs. On-line monitoring technology, therefore, is essential to detect system faults. In this paper, the ICA-based fault detection method is conducted using three different multivariate process data. Fault detection procedure based on ICA is divided into off-line and on-line processes. The off-line process determines a threshold for fault detection by using the obtained dataset when the system is normal. And the on-line process computes statistics of query vectors measured in real-time. The fault is detected by comparing computed statistics and previously defined threshold. For comparison, the PCA-based fault detection method is also implemented in this paper. Experimental results show that the ICA-based fault detection method detects the system faults earlier and better than the PCA-based method.

Risk Assessment of Micro and Emerging Contaminants in Domestic Effluent Environment: Targeting on 80 First-class substances assigned by Ministry of Environment (미량 및 신종유해물질의 국내 방류 환경에서의 위해성 평가: 환경부 지정 1순위 80종 대상으로)

  • Lee, Jai-Yeop;Park, Saerom;Kim, Ilho
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.6
    • /
    • pp.501-509
    • /
    • 2021
  • In 2018, total 263 micro and emerging contaminants were selected as target substances by the Ministry of Environment, and 80 of them were first-class substance including endocrine disruptors, residual Pharmaceuticals and Personal Care Products (PPCPs), residual organic pollutants, pesticides and heavy metals. In this study, in order to evaluate the Hazard Quotient (HQ) of the 80 types in the domestic water environment the concentration of discharged effluent and nearby water environment reported by Korean institutes since 2010 was investigated. There were 45 substances reported to be detected, and Measurement Environment Concentration (MEC) were obtained by collectively converting them into water environment concentration. For biotoxicity, half maximal Effective Dose (EC50) to Daphnia magna, a water fleas species widely adopted in Material Safety Data Sheet (MSDS) was applied. As for the biotoxicity level, the Predicted No-Effect Concentration (PNEC) was obtained by applying the Assessment Factor (AF) and the HQ was derived by dividing it from the MEC. As a result of calculating the HQ, more than 1 substances were Cabamazepine, Mefenamic acid, Acetaminophen, Ibuprofen, Nonylphenol, Nickel, Erythromycin, Acetylslic acid, etc. Meanwhile, perfluorinated compounds were identified as hazardous substances in the water env ironment, with 5 out of 14 species included in the 20 ranks of first-class substance.

Seismic Retrofit Assessment of Different Bracing Systems

  • Sudipta Chakraborty;Md. Rajibul Islam;Dookie Kim;Jeong Young Lee
    • Architectural research
    • /
    • v.25 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Structural ageing influences the structural performance in a negative way by reducing the seismic resilience of the structure which makes it a major concern around the world. Retrofitting is considered to be a pragmatic and feasible solution to address this issue. Numerous retrofitting techniques are devised by researchers over the years. The viability of using steel bracings as retrofitting component is evaluated on a G+30 storied building model designed according to ACI318-14 and ASCE 7-16. Four different types of steel bracing arrangements (V, Inverted V/ Chevron, Cross/ X, Diagonal) are assessed in the model developed in commercial nu-merical analysis software while considering both material and geometric nonlinearities. Reducing displacement and cost in the structures indicates that the design is safe and economical. Therefore, the purpose of this article is to find the best bracing system that causes minimum displacement, which indicates maximum lateral stiffness. To evaluate the seismic vulnerability of each system, incremental dynamic analysis was conducted to develop fragility curves, followed by the formation of collapse margin ratio (CMR) as stipulated in FEMA P695 and finally, a cost estimation was made for each system. The outcomes revealed that the effects of ge-ometric nonlinearity tend to evoke hazardous consequences if not considered in the structural design. Probabilistic seismic and economic probes indicated the superior performance of V braced frame system and its competency to be a germane technique for retrofitting.

A Repository for Publications on Basic Occupational Health Services and Similar Health Care Innovations

  • Frank J. van Dijk;Suvarna Moti
    • Safety and Health at Work
    • /
    • v.14 no.1
    • /
    • pp.50-58
    • /
    • 2023
  • Background: Occupational health services are not available for more than 80% of the global workforce. This pertains especially to informal workers, workers in agriculture and in small enterprises, and self-employed. Many are working in hazardous conditions. The World Health Organization, the International Labor Organization, the International Commission on Occupational Health, and the World Organization of Family Doctors promote as part of a solution, basic occupational health services (BOHS) integrated in primary or community health care. Quality information on this topic is difficult to find. The objective of this study is to develop an open access bibliography, a repository, referring to publications on BOHS and similar innovations, to support progress and research. Methods: The database design and sustaining literature searches (PubMed, Google Scholar, SciELO) are described. For each publication selected, basic bibliographic data, a brief content description considering copyright restrictions, and a hyperlink are included. Results: Searches resulted in a database containing 189 references to publications on BOHS such as articles in scientific journals, reports, policy documents, and abstracts of lectures. A global perspective is applied in 43 publications, a national or regional perspective is applied in 146 publications. Operational and evaluative research material is still scarce. Examples of references to publications are shown. Conclusion: The repository can inspire pioneers by showing practices in different countries and can be used for reviews and in-depth analyses. Missing publications such as from China, Russia, Japan, Republic of Korea, and Spanish/Portuguese speaking countries, can be added in the future, and translated. Search functions can be developed. International collaboration for the promotion of occupational health coverage for all workers must be intensified.

Awareness Patterns Regarding Radiation Safety Management in Fields Related to Radiation Safety Regulations: Focusing on Companies that Must Report Radiation Sources

  • Eunok Han;Yoonseok Choi
    • Journal of Radiation Protection and Research
    • /
    • v.49 no.1
    • /
    • pp.19-28
    • /
    • 2024
  • Background: This study aims to analyze radiation safety management and regulatory perceptions, focusing on companies that must report radiation sources. The intent is to reduce the gap between regulation measures and addressing real concerns while improving practical safety management measures and regulations for all stakeholders. Materials and Methods: Radiation safety officers at a total of 244 reporting companies using radiation generators (79.8%) and sealed radioisotopes (15.1%) were surveyed using a questionnaire. Results and Discussion: The perception that regulation is stronger than the actual risk of the radiation source used was 3.47 points (out of 5 points), indicating a score above average. The most important factors and considerations were education and training (48%) as a human factor, safety devices of the radiation source (71.3%) as a hazardous material factor, the use of radiation (50.8%) as an organizational environment, and the radiation effect of nearby facilities (67.2%) as a physical environment. Radiation safety management educational experience (F= 5.030, p< 0.01), the group with high subjective knowledge (t= 6.017, p< 0.001), and the group with high objective knowledge (t= 1.989, p< 0.05) was found to be better at radiation safety management. Conclusion: It is necessary to standardize the educational experience regarding radiation safety management because each staff member has individual differences in educational experience. It is necessary to provide more information on how to solve radiation accidents via educational content. Applying radiation safety regulations based on the factors that significantly affect radiation safety management shown in this survey will help improve safety.

A Study on the Selectively Block Barrier for Prevent the Spread of TPH and Phenol in the Ground (지중 내 TPH, Phenol의 확산방지를 위한 선택적 차수재 제조에 관한 연구)

  • HoJin Lim;WooRi Cho;SeungJin Oh;SuHee Kim;JaiYoung Lee
    • Journal of the Korean Geosynthetics Society
    • /
    • v.23 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • In this study, a selecvively block barrier was developed to prevent the spread of contaminants (TPH, Phenol) in the ground only when contamination occurs. The materials were used Jumunjin sand, bentonite, polyolefin elastomer and spill hound marine. First, the properties and environmental hazards characteristics of materials were analyzed for evaluated their usability. Then, the possibility of use as a barrier material was confirmed by analyzing the water permeability characteristics that change after 24 hours of contact with contaminants. As a result of the analysis, the pH of each component was similar to the general groundwater pH range. In addition, the toxicity characteristics and the possibility of dissolution of hazardous substances, it was determined that there was no environmental hazard as the content was below the regulation value. Lastly, when comparing the permeability coefficient before and after contact with the contaminant, the permeability coefficient of approximately α × 10-3cm/sec before contact was reduced to α × 10-6cm/sec after contact with the contaminant.