• Title/Summary/Keyword: hazardous

Search Result 2,780, Processing Time 0.03 seconds

Monitoring and Exposure Assessment of Pesticide Residues in Domestic Agricultural Products (국내 유통 다소비 농산물의 잔류농약 모니터링 및 노출평가)

  • Kang, Namsuk;Kim, Seongcheol;Kang, Yoonjung;Kim, Dohyeong;Jang, Jinwook;Won, Sera;Hyun, Jaehee;Kim, Dongeon;Jeong, Il-Yong;Rhee, Gyuseek;Shin, Yeongmin;Joung, Dong Yun;Kim, Sang Yub;Park, Juyoung;Kwon, Kisung;Ji, Youngae
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.1
    • /
    • pp.32-40
    • /
    • 2015
  • This study was implemented to evaluate food safety on residual pesticides in agricultural products of Korea and to use as a data base for the establishment of food policy. A total of 196 pesticide upon these products were analyzed using multi class pesticide multiresidue methods of Korean Food Code, and 232 samples of 15 agricultural products collected from 9 regions were supplied for this study. In the results, 64 kinds of pesticides were detected in 53 samples, chlorpyrifos and procymidone of them were shown a high frequency of detection in the analyzed pesticides. Among them, two samples (chlorpyrifos in perilla leaves and picoxystrobin in peach) were detected over Maximum Residue Limits (MRLs). The levels of the detected pesticide residues were within safe levels. Also, the intake assessment for pesticide residues including chlorpyrifos at multi pesticide residue monitoring were carried out. The result showed that the ratio of EDI (estimated daily intake) to ADI (acceptable daily intake) was 0.001~0.902% which means that the detected pesticide residues were in a safe range so that residual pesticides in the agricultural products in Korea are properly controlled.

Comparative Analysis of IEC Standard and Simulation Results for Hydrogen Hazardous Distance (수소 폭발위험범위에 대한 IEC기준과 시뮬레이션 결과의 비교분석)

  • Seung-Hyo An;Eun-Hee Kim;Seon-Hee Lee;Byung-Chol Ma
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.19-26
    • /
    • 2024
  • In workplaces handling flammable gas such as hydrogen, hazardous area is determined through KS C IEC 60079-10-1 standard. Because this standard determines the hazardous distance based on the release characteristic regardless of the type of gas, indoor/outdoor conditions, and atmospheric conditions, concerns are being raised about the effectiveness. In this study, simulations (PHAST, HyRAM) were performed to calculate the hazardous distance for hydrogen under various release characteristics and atmospheric conditions, and compared these results to IEC standard log-log graph. Also, we performed regression analysis according to each result. we found that the simulation results were 0.6 to 3.8 times less than the IEC standard, presented convenient linear regression equations. In addition, We confirmed that the results of hazardous distance varied based on wind velocity and atmospheric stability at the same release characteristic. In addition, we derived linear regression equations for release characteristics and hazardous distance that can be conveniently utilized. So, when classifying hazardous area in workplaces where they handle the hydrogen, the integrated graph and linear regression equation are helpful for confirming the hazardous area. Moreover, it is expected that the economic burden will be minimized by being able to classify reasonable hazardous area and to greatly reduce the risk of hydrogen explosion.

Brief study on Restriction of Hazardous Substances Directive (RoHS) (유해물질(有害物質) 제한지침(制限指針)(Restriction of Hazardous Substances Directive, RoHS)의 현황(現況))

  • Kumar, J. Rajesh;Lee, Jin-Young;Kim, Joon-Soo;Shhn, Jeong-Soo
    • Resources Recycling
    • /
    • v.17 no.6
    • /
    • pp.3-9
    • /
    • 2008
  • The Directive on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment commonly referred to as the Restriction of Hazardous Substances Directive or RoHS was adopted in February 2003 by the European Union. The RoHS directive took effect on 1 July 2006, and is required to be enforced and become law in each member state. This directive restricts the use of six hazardous materials in the manufacture of various types of electronic and electrical equipment. It is closely linked with the waste electrical and electronic equipment directive (WEEE) 2002/96/EC which sets collection, recycling and recovery targets for electrical goods and is part of a legislative initiative to solve the problem of huge amounts of toxic e-waste.

An Investigation of Ingredients and Hazardous Substances in Some Consumer Products - Focusing on Cleaners and Disinfectants - (일부 생활화학용품에 함유된 성분 및 유해물질 조사 - 세정제와 소독제를 중심으로 -)

  • Heo, Da-An;Huh, Eun-Hae;Park, Ji Young;Moon, Kyong Whan;Lee, Kiyoung
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.5
    • /
    • pp.314-326
    • /
    • 2015
  • Objectives: This study was conducted to identify the ingredients used in ten consumer product categories and determine hazardous substances among these ingredients. Methods: A total of 542 commercial products in ten consumer product categories were selected. The consumer products were sticker removers, washing machine cleaners, multi-purpose cleaners, mold removers, glass cleaners, chlorinated sanitizers, air conditioner cleaners, disposal cleaners, drain cleaners and disinfectant sprays. The company list was complied from governmental records and a market survey. The respective companies were contacted for a list of ingredients found in the 542 products. Results: The corresponding companies listed 163 ingredients. According to European Union (EU) Directive 67/548/EEC, 38 of the 163 ingredients were classified as dangerous substances. Among these substances, 28 ingredients were hazardous to the skin, 15 were hazardous to the eye, and nine were hazardous if inhaled. Three ingredients were classified as CMR (carcinogenic, mutagenic or toxic for reproduction) substances: liquefied petroleum gases (LPG) with carcinogenicity and mutagenicity, and VM&P naphtha and ligroine with carcinogenicity. Conclusion: Various chemicals, including hazardous substances, were used in consumer products. Risk assessment of consumer products is required in order to protect the population from health risks.

The effect of ventilation on reducing the concentration of hazardous substances in the indoor air of a Korean living environment

  • Kim, Hyunjoo;Kim, Jin Seog;Lee, Jongman;Kim, Dalho
    • Analytical Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.49-57
    • /
    • 2020
  • Controlling the quality of indoor air is important in order to maintain a healthy life. In this study, we investigated the correlation between the hazardous substance concentration of indoor air and circulation based on different ventilation methods in the apartment, which is one of the representative housing types in Korea. As target substances, we considered the hazardous substances which are generated during the cooking process and radon gas which is originated from building materials. We measured the concentrations of carbon dioxide and fine particles in relation to type of food and ventilation methods in order to determine the change in the concentration levels of hazardous substances which are generated during the cooking process. On the other hand, we measured the concentration of radon gas before and after letting fresh air into a room through windows in order to determine the change in the concentration level of radon gas which is originated from building materials. The results show that turning on the ventilation fan plays a major role in reducing the concentration levels of hazardous substances in the kitchen, and that it is more effective to turn on the ventilation fan during cooking than after cooking to prevent the diffusion of hazardous materials produced by cooking through the indoor air. Also, the results indicate that letting fresh air into a room through windows more than one time a day is necessary to reduce the concentration level of radon gas in the room to safe concentration range.

Hazardous Metal Pollution in the Republic of Fiji and the Need to Elicit Human Exposure

  • Park, Eun-Kee;Wilson, Donald;Choi, Hyun-Ju;Wilson, Colleen Turaga;Ueno, Susumu
    • Environmental Analysis Health and Toxicology
    • /
    • v.28
    • /
    • pp.17.1-17.3
    • /
    • 2013
  • The fact that hazardous metals do not bio-degrade or bio-deteriorate translates to long-lasting environmental effects. In the context of evidently rapid global industrialization, this ought to warrant serious caution, particularly in developing countries. In the Republic of Fiji, a developing country in the South Pacific, several different environmental studies over the past 20 years have shown levels of lead, copper, zinc and iron in sediments of the Suva Harbor to be 6.2, 3.9, 3.3 and 2.1 times more than the accepted background reference levels, respectively. High levels of mercury have also been reported in lagoon shellfish. These data inevitably warrant thorough assessment of the waste practices of industries located upstream from the estuaries, but in addition, an exposure and health impact assessment has never been conducted. Relevant government departments are duty-bound, at least to the general public that reside in and consume seafood from the vicinities of the Suva Harbor, to investigate possible human effects of the elevated hazardous metal concentrations found consistently in 20 years of surface sediment analysis. Furthermore, pollution of the intermediate food web with hazardous metals should be investigated, regardless of whether human effects are eventually confirmed present or not.

Risk Analysis of Transporting Hazardous Substances in Harbor Using Modeling Program (항만에서 위험물 운송 중 유해화학물질 누출 위험성에 관한 연구)

  • Yoon, Sukyoung;Yun, Jayeon;Han, Jiyun;Jung, Seungho
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.272-278
    • /
    • 2018
  • Recently, the use of hazardous chemicals has been continuously increasing. Therefore, the international trade volume is growing and chemical accidents have increased. Nowadays, the safety awareness of the public has increased. As a result, the management and supervision of hazardous chemicals have been strengthened. However, the port policy of Korea has focused on increasing the volume of cargo through facility development. Thus, the port management of hazardous chemicals has been relatively neglected. For national economic growth and society, the port management of hazardous chemicals should be considered to efficiently ensure safety and economic growth. Therefore, this study assumed scenarios where hazardous materials were moved in a dangerous container, not only on appropriate wharfs but also in ports that were close to a big city. The BTX substances were selected among the toxic chemicals with large import and export volumes, and the risk distance and damage effects were predicted using various risk assessment programs. It is expected that this could be used to improve a port safety management system and could be utilized to determine the safety distance in case of an accident.

Analysis of Hazardous Fog and Index Development in Korea (도로상 위험안개의 특징분석 및 발생지표의 개발)

  • 조혜진
    • Journal of the Korean Geographical Society
    • /
    • v.38 no.4
    • /
    • pp.478-489
    • /
    • 2003
  • The existing researches related to the fog have focused on mainly the fog itself and its spatial variation. This study defined the hazardous fog as the fog with visibility under 500 m which caused the severe dangerous situation on roads and might cause traffic accident due to insufficient visibility. This study aimed to develop the hazardous fog index which quantified the degree of danger and included frequency of fog, visibility and its duration. We applied the index to 3 years weather station data in Korea and the results showed the distribution of the hazardous fog and their priority in terms of safety management. This was the first study that introduced the fog index in Korea and that quantified the degree of hazardous fog. These application results were useful for identifying the dangerous area due to hazardous fog and contributing to ensure the safety of eventual road users and road authorities.

Current Status and Prospective of Hazardous VOC in Ambient Air (환경대기 중 유해성 VOC 측정에 관한 동향과 전망)

  • Seo, Young-Kyo;Chung, Sun-Ho;Baek, Sung-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.734-745
    • /
    • 2011
  • In this article, we reviewed the monitoring status of hazardous VOC in ambinet air in Korea and some developed countries such as USA, Japan, and UK. In many countries, two types of VOC monitoring stations are being operated, i.e., for hazardous VOC and photochemical VOC. Each country has different target VOC but all includes benzene. Korea, Japan, and UK have a national ambient air quality standard for benzene, but no national standard has been established in the USA. For sampling of the hazardous VOC, the adsorbent method is adopted in Korea and UK, while the canister method is used in the USA. Both of adsorbent and canister methods are used in Japan. USA and UK have only non-automatic method to measure the hazardous VOC, and the individual samples are being sent to their national laboratories for integrated analysis. On the other hand, Korea and Japan have automatic and nonautomatic methods to measure the hazardous VOC. Local governments or regional environmental agencies in Korea and Japan have the authorization for the sampling and analysis of VOC. According to a field study to evaluate the performance of automatic VOC monitoring system, controlling the moisture in the air sample was identified as the most important problem. However, careful attention must be given to using a moisture removing device such as Nafyon dryer, because of unexpected artifacts formation. In order to have reliable data, it is highly recommended not only to use internal standards, but to use appropriate hydrophobic adsorbents as a cold trap in any automatic on-line VOC monitoring system.

A Study on the Fire Risk Assesment of Solvent-based Paints (유성페인트의 화재 위험성평가에 관한 연구)

  • Lee, Bong-Woo;Kwon, Seong-Pil
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.1-7
    • /
    • 2017
  • Currently, flammable liquids account for more than 87 wt% of the hazardous materials in circulation in Korea, and paint products are the most commonly used mixed hazardous materials. Therefore, one of the most urgent and important issues is that we have to secure the safety for manufacturing, storage and transport of paint products. In this study we investigated and analyzed the domestic hazardous materials safety management method, the international GHS test method and so forth. We tested risks for a variety of oil paints and found a relation between the results. Furthermore, the risk test method and criteria adapted for domestic situation was presented. Paints were classified as hazardous or non-hazardous according to the results of the flash point test, the amount of flammable liquid or the UN-combustion persistence test. It was revealed from the test results of 6 kind of oil-based paints using different resins that they were hazardous materials with very high risks and belonged to the Category 1 or the Category 2.