DOI QR코드

DOI QR Code

Current Status and Prospective of Hazardous VOC in Ambient Air

환경대기 중 유해성 VOC 측정에 관한 동향과 전망

  • Seo, Young-Kyo (Department of Environmental Engineering, Yeungnam University) ;
  • Chung, Sun-Ho (Department of Environmental Engineering, Yeungnam University) ;
  • Baek, Sung-Ok (Department of Environmental Engineering, Yeungnam University)
  • Received : 2011.11.03
  • Accepted : 2011.11.30
  • Published : 2011.12.31

Abstract

In this article, we reviewed the monitoring status of hazardous VOC in ambinet air in Korea and some developed countries such as USA, Japan, and UK. In many countries, two types of VOC monitoring stations are being operated, i.e., for hazardous VOC and photochemical VOC. Each country has different target VOC but all includes benzene. Korea, Japan, and UK have a national ambient air quality standard for benzene, but no national standard has been established in the USA. For sampling of the hazardous VOC, the adsorbent method is adopted in Korea and UK, while the canister method is used in the USA. Both of adsorbent and canister methods are used in Japan. USA and UK have only non-automatic method to measure the hazardous VOC, and the individual samples are being sent to their national laboratories for integrated analysis. On the other hand, Korea and Japan have automatic and nonautomatic methods to measure the hazardous VOC. Local governments or regional environmental agencies in Korea and Japan have the authorization for the sampling and analysis of VOC. According to a field study to evaluate the performance of automatic VOC monitoring system, controlling the moisture in the air sample was identified as the most important problem. However, careful attention must be given to using a moisture removing device such as Nafyon dryer, because of unexpected artifacts formation. In order to have reliable data, it is highly recommended not only to use internal standards, but to use appropriate hydrophobic adsorbents as a cold trap in any automatic on-line VOC monitoring system.

Keywords

References

  1. Badol, C., A. Borbon, N. Locoge, T. Leonardis, and J.C. Galloo (2004) An automated monitoring system for VOC ozone precursors in ambient air: development, implementation and data analysis, Anal. Bioanal. Chem., 378(7), 1815-1824. https://doi.org/10.1007/s00216-003-2474-0
  2. Baek, S.O. (1996) Sampling and analytical methods for the determination of volatile organic compounds in ambient air, Korean J. of Atmos. Environ., 12(1), 1-13. (in Korean with English abstract)
  3. Baek, S.O., M.H. Kim, and Y.K. Seo (2003) Evaluation of fugitive emission characteristics of airborne volatile organic compounds from different source categories, Korean J. of Atmos. Environ., 19(4), 363-376. (in Korean with English abstract)
  4. Choi, Y.J., K.H. Kim, S.I. Oh, and Z.H. Shon (2004) Continuous measurements of reduced sulfur gases in urban air, Korea, Korean J. of Atmos. Environ., 20(2), 195-204. (in Korean with English abstract)
  5. Japan MOE (1997) Guidelines of hazardous air pollutants monitoring.
  6. Kim, J.C. (2006) Trends and control technologies of volatile organic compound, Korean J. of Atmos. Environ., 22(6), 743-757. (in Korean with English abstract)
  7. Kim, K.H., D.W. Ju, Y.J. Choi, Y.J. Hong, E.C. Jeon, C.R. Choi, and Y.S. Koo (2006) An on-line GC analysis of odorous VOCs and S gas in ambient air from a residential area at Ansan city, Korea, Korean J. of Atmos. Environ., 22(6), 929-939. (in Korean with English abstract)
  8. Korea MOE (2009a) Notification No. 2009-198 of the Ministry of the Environment.
  9. Korea MOE (2009b) Atmosphere environment annual report, 71 pp.
  10. Korea MOE (2010a) Guidelines of air pollutants measurement station installation and operation, 31 pp.
  11. Korea MOE (2010b) Guidelines of air pollutants measurement station installation and operation, 182 pp.
  12. Lee, J.H., J.S. Han, H.K. Yun, and S.Y. Cho (2007) Evaluation of incremental reactivity and ozone production contribution of VOC using the PAMS data in Seoul metropolitan area, Korean J. of Atmos. Environ., 23(3), 286-296. (in Korean with English abstract) https://doi.org/10.5572/KOSAE.2007.23.3.286
  13. Parrish, D.D. and F.C. Fehsenfeld (2000) Methods for gas-phase measurements of ozone, ozone precursors and aerosol precursors, Atmos. Environ., 34(12-14), 1921-1957. https://doi.org/10.1016/S1352-2310(99)00454-9
  14. Son, E.S., Y.K. Seo, D.H. Lee, M.D. Lee, J.S. Han, and S.O. Baek (2009) A study on the performance optimization of a continuous monitoring method for hazardous VOC in the ambient atmosphere, Korean J. of Atmos. Environ., 25(6), 523-538. (in Korean with English abstract) https://doi.org/10.5572/KOSAE.2009.25.6.523
  15. Su, Y.C., C.C. Chang, and J.L. Wang (2008) Construction of an automated gas chromatography/mass spectrometry system for the analysis of ambient volatile organic compounds with on-line internal standard calibration, Journal of Chromatography A, 1201(2), 134-140. https://doi.org/10.1016/j.chroma.2008.03.071
  16. UK DOE (2011) http://uk-air.defra.gov.uk/networks/networkinfo?view=nahc (searching date: 2011.7.8.)
  17. US EPA (1999a) Compendium of Methods TO-14A, Determination of volatile organic compounds in ambient air using specially prepared canisters with subsequent analysis by gas chromatography, 2nd Ed., EPA/625/R-96/010b.
  18. US EPA (1999b) Compendium of method TO-17, Determination of volatile organic compounds in ambient air using active sampling onto sorbent tubes, 2nd Ed., EPA/625/R-96/010b.
  19. US EPA (2006) Urban air toxics monitoring program (UATMP) final report, EPA-454/R-07-001.
  20. WHO(2000) Guidelines for air quality, geneva, 2000.
  21. Yamamoto, N., H. Okayasu, T. Hiraiwa, S. Murayama, T. Maeda, M. Morita, and K. Suzuki (1998) Continuous determination of volatile organic compounds in the atmosphere by an automated gas chromatographic system, Journal of Chromatography A, 819(1-2), 177-186. https://doi.org/10.1016/S0021-9673(98)00422-1

Cited by

  1. Management Changes of Hazardous Air Pollutants Sources and Its Proposed Improvement in Korea vol.29, pp.5, 2013, https://doi.org/10.5572/KOSAE.2013.29.5.536
  2. The Concentrations of Ambient VOCs at Industrial Complex Area in Daegu City vol.36, pp.7, 2014, https://doi.org/10.4491/KSEE.2014.36.7.498