• Title/Summary/Keyword: harmonics spectrum

Search Result 101, Processing Time 0.023 seconds

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

Refinement of GRACE Gravity Model Including Earth's Mean Mass Variations (지구 평균 질량 변화를 포함한 GRACE 중력 모델 보정)

  • Seo, Ki-Weon;Eom, Jooyoung;Kwon, Byung-Doo
    • Journal of the Korean earth science society
    • /
    • v.35 no.7
    • /
    • pp.537-542
    • /
    • 2014
  • The Gravity Recovery and Climate Experiment (GRACE) has observed the Earth's mass redistribution mainly caused by the variations of groundwater, ice sheet, and sea level since its launch in April 2002. The global gravity model estimated by the GRACE observation is corrected by barometric pressure, and thus represents the change of Earth mass on the Earth's surface and below Earth's surface excluding air mass. However, the total air mass varies due to the water exchange between the Earth's surface and the atmosphere. As a result, the nominal GRACE gravity model should include the Earth's gravity spectrum associated with the total air mass variations, degree 0 and order 0 coefficients of spherical harmonics ($C_{00}$). Because the water vapor content varies mainly on a seasonal time scale, a change of $C_{00}$ (${\delta}C_{00}$) is particularly important to seasonal variations of sea level, and mass balance between northern and southern hemisphere. This result implies that ${\delta}C_{00}$ coefficients should be accounted for the examination of continental scale mass change possibly associated with the climate variations.

Prediction of Near Magnetic Field Distribution of Switching ICs (스위칭 IC의 근접 자계 분포 예측)

  • Kim, Hyun-Ho;Song, Reem;Lee, Seungbae;Kim, Byung-Sung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.10
    • /
    • pp.907-913
    • /
    • 2015
  • This work presents a method to predict the near magnetic field distribution on the digital switching circuit mounted on PCB using co-simulation of circuit and electromagnetic fields. The proposed method first obtains the normalized near field distribution by exciting the signal and power ports of the switching circuit using sinusoidal sources. Then the real near magnetic field distribution is determined by weighting the normalized field distribution using the current spectrum of the switching circuit. To confirm the proposed method, a switching IC with a ring oscillator and a output buffer is fabricated and measured in the form of chip-on-board. The surface magnetic field distribution is measured using a magnetic probe above the PCB and compared with the simulation results. Experimental results show the correspondence between simulation and measurement results within 10 dB up to fifth harmonics.

Modeling and Detent Torque Hormonic Analysis of Hybrid Type Step Motor (하이브리드형 스텝모터의 모델링 및 디텐트 토크 고조파 분석)

  • Yoon, Shin-Yong;Baek, Soo-Hyun;Kim, Yong;Kim, Cherl-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.14-21
    • /
    • 2002
  • This paper did the study target for modeling, characteristics analysis and harmonic reduce with the detent torque of a 4 phase and 5 phase hybrid type step motor. For this, it was attempted to derive the mathematical modeling and used the permeance method for flux field analysis. Through this analysis result, this paper acquired the detent torque of this model. To compare the characteristics analysis of phase difference with two motors structure it have obtained to derive the operating detent torque with this model. Here, 5 phase motor has known the harmonic reduce of detail torque compare with 4 phase motor. Also, that has showed to improved the step response. The analysis result has represent the effect that a fundamental component of the permeance distribution produces the average torque and that harmonic components produce the ripple torque.

Harmonic Analysis and Filter Design on Distribution System using SuperHarm (배전계통에서의 SuperHarm을 이용한 고조파.분석 및 필터 설계)

  • 이종포;김철환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.5
    • /
    • pp.36-42
    • /
    • 2000
  • The increasing application of power electronic equipment 'especially (ASDs: adjustable speed drives)] on distribution systems has led to a growing concern for harmonic distortion and the resulting impacts on system equipment and operations. Therefore, harmonic studies have become an important aspect of power system analysis and design in recently years. Computer simulations which is related harmonic are used to quantify the distortion in voltage waveforms in a power system. Many digital computer programs are available for harmonic analysis. In frequency spectrum analysis, Simulation using SuperHarm program is superior to simulation using others. Therefore, Computer simulation using SuperHarm program is one of the effective ways to assess the harmonic effects of ASDs. The purpose of this study is to calculate the quantity of harmonic voltage by varying the ASD side load and to design the optimal harmonic filter for the elimination of harmonics.

  • PDF

2.4kbps Speech Coding Algorithm Using the Sinusoidal Model (정현파 모델을 이용한 2.4kbps 음성부호화 알고리즘)

  • 백성기;배건성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.3A
    • /
    • pp.196-204
    • /
    • 2002
  • The Sinusoidal Transform Coding(STC) is a vocoding scheme based on a sinusoidal model of a speech signal. The low bit-rate speech coding based on sinusoidal model is a method that models and synthesizes speech with fundamental frequency and its harmonic elements, spectral envelope and phase in the frequency region. In this paper, we propose the 2.4kbps low-rate speech coding algorithm using the sinusoidal model of a speech signal. In the proposed coder, the pitch frequency is estimated by choosing the frequency that makes least mean squared error between synthetic speech with all spectrum peaks and speech synthesized with chosen frequency and its harmonics. The spectral envelope is estimated using SEEVOC(Spectral Envelope Estimation VOCoder) algorithm and the discrete all-pole model. The phase information is obtained using the time of pitch pulse occurrence, i.e., the onset time, as well as the phase of the vocal tract system. Experimental results show that the synthetic speech preserves both the formant and phase information of the original speech very well. The performance of the coder has been evaluated in terms of the MOS test based on informal listening tests, and it achieved over the MOS score of 3.1.

The Performance Analysis of the Parameter Extracting Technique for the Vibration Monitoring System in High Voltage Motor (고압전동기용 진동 감시 시스템의 계수 추출기법 성능 분석)

  • Park, Jung-Cheul;Lee, Dal-Ho
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.5
    • /
    • pp.529-536
    • /
    • 2019
  • In this paper, the signals of the sensor for extracting characteristic parameters of the rotor are collected and the performance of the extraction technique is analyzed. To this end, a vibration test league was developed for conducting model tests to analyze the signal characteristics under normal operation. As a result, it is judged that no change in the measured the raw data amplitude will occur in the acceleration sensor with the unbalanced mass measured from the acceleration sensor. Performing FFT showed a significant increase in amplitude of the rotational frequency of 20 Hz as the unbalanced mass increased. The analysis results according to the change in the unequal mass of the speed sensor also showed a significant increase in the 1X Harmonics component, such as the acceleration sensor. There was no change in the amplitude of the acceleration sensor data when the misalignment occurred, and for the Envelope data, the amplitude of 2X (40 Hz) was increased depending on the degree of misalignment. The velocity sensor at change of misalignment also showed similar results to the acceleration sensor, and the peak was reduced at 600 Hz as the load increased in the frequency spectrum.

A CELP Coder using the Band-Divided Long Term Prediction (대역 분할 장구간 예측을 이용한 CELP 부호화기)

  • Choi, Young-Soo;Kang, Hong-Goo;Lim, Myoung-Seob;Ahn, Dong-Soon;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.4
    • /
    • pp.38-45
    • /
    • 1995
  • In this paper a way to improve the performance of the long term prediction is proposed, which adopts the Multi-band Excitation (MBE) method in addition to the Code-Excited Linear Prediction (CELP) method at low bit rates below 4.8 kbps. In the proposed method, the multiband long term prediction is performed on the periodic components which still remain after the long term prediction of the conventional CELP method. At this point, the whole frequency region is divided into subbands whose size is equal to the spacing between the harmonics of the fundamental frequency, and the periodic multiband excitation signals. are represented as the sum of sine waves approximately as large as the spectrum of the excitation signals, so that the actual characteristics of the excitation signals can be better taken into account. To evaluate the performance of the proposed method, computer simulation is performed at 4.8 kbps. The 4.8 kbps DoD CELP and the 4.4 kbps IMBE were chosen as the reference vocoders for the speech quality measure. The result of the perceptual speech quality measure showed that the performance of the proposed method is better than that of the 4.8 kbps DoD CELP vocoder, and similar to that of the 4.4 kbps IMBE vocoder.

  • PDF

A Study on the Implementation of the 2-Dimension Magnetic Fluxgate Sensor (2차원 Magnetic Fluxgate센서의 구현에 관한 연구)

  • Park, Yong-Woo;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.67-76
    • /
    • 2002
  • We have presented a 2-dimensional fluxgate sensor with ferrite core, excitation, and pick-up coil. This fluxgate sensor system consists of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through the excitation coil of 80 turns. The second harmonic output of pick-up coil(x and y axis: 100 turns) is measured by FFT spectrum analyzer. This result is compared with output of PSD(phase sensitive detector) unit for detecting the second harmonic component. The measured maximum sensitivity is about 1580 V/T at driving frequency of 1.5 kHz and excitation current of 2 App. The nonlinearity of this system is measured about 2.3%(PSD) and about 1%(second harmonics of the pick-up). The angle error of the system is ${\pm}2$ %/FS.

Hand Motion Signal Extraction Based on Electric Field Sensors Using PLN Spectrum Analysis (PLN 성분 분석을 통한 전기장센서 기반 손동작신호 추출)

  • Jeong, Seonil;Kim, Youngchul
    • Smart Media Journal
    • /
    • v.9 no.4
    • /
    • pp.97-101
    • /
    • 2020
  • Using passive electric field sensor which operates in non-contact mode, we can measure the electric potential induced from the change of electric charges on a sensor caused by the movement of human body or hands. In this study, we propose a new method, which utilizes PLN induced to the sensor around the moving object, to detect one's hand movement and extract gesture frames from the detected signals. Signals from the EPS sensors include a large amount of power line noise usually existing in the places such as rooms or buildings. Using the fact that the PLN is shielded in part by human access to the sensor, signals caused by motion or hand movement are detected. PLN consists mainly of signals with frequency of 60 Hz and its harmonics. In our proposed method, signals only 120 Hz component in frequency domain are chosen selectively and exclusively utilized for detection of hand movement. We use FFT to measure a spectral-separated frequency signal. The signals obtained from sensors in this way are continued to be compared with the threshold preset in advance. Once motion signals are detected passing throng the threshold, we determine the motion frame based on period between the first threshold passing time and the last one. The motion detection rate of our proposed method was about 90% while the correct frame extraction rate was about 85%. The method like our method, which use PLN signal in order to extract useful data about motion movement from non-contact mode EPS sensors, has been rarely reported or published in recent. This research results can be expected to be useful especially in circumstance of having surrounding PLN.