• Title/Summary/Keyword: harmonics compensation

Search Result 195, Processing Time 0.027 seconds

Hybrid Current Mode Controller with Fast Response Characteristics for DC/DC Converter (빠른 응답특성을 갖는 DC/DC 컨버터 하이브리드 전류 모드 제어기)

  • Oh, Seung-Min;Baek, Seung-Woo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.2
    • /
    • pp.134-137
    • /
    • 2019
  • A wide-bandwidth current controller is required for fast charging/discharging of super capacitor applications. Peak current mode is generally used to accomplish fast charging/discharging because this mode has fast response characteristics. However, the peak current mode control must have a slope compensation function to restrain sub-harmonics oscillation. The slope must be changed accordingly if the controlled output voltage is varied. However, changing the slope for every changed output voltage is not easy. The other solution, selecting the slope as the maximum value, causes a slow response problem to occur. Therefore, we propose a hybrid mode controller that uses a peak current and a newly specified valley current. Through the proposed hybrid mode control, the sub-harmonic oscillation does not occur when the duty is larger than 0.5 because of the fast response.

Output Voltage Harmonics Analysis of NPC Type Three-level Inverter (NPC형 3레벨 인버터의 출력전압 고조파 분석)

  • Kwon, Kyoung-Min;Choi, Jae-Ho;Chung, Gyo-Bum
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.472-480
    • /
    • 2009
  • This paper describes the overmodulative SVPWM technique and harmonics analyses of three phase NPC type three-level inverter to the modulation index. Three phase NPC type three-level inverter adopted SVPWM to extend the linear region to 0.907, moreover, the following voltage compensation using Fourier series was adopted in the region of overmodulation to make it work to six-step level. PD type of multi carrier method is used with the double Fourier series for the analysis of output power harmonics characteristic. Simulation was performed by PSIM, and the harmonics characteristics of 3-level inverter in each region are analyzed. The side band harmonics of carrier frequency are dominant in the linear region, but these harmonic components are decreased as the inveter goes to overmodulation region, and the harmonics due to the fundamental frequency is increased gradually at the same time. The harmonic analyses are verified through the simulation and experimental results under the same condition.

Power Control Strategies for Single-Phase Voltage-Controlled Inverters with an Enhanced PLL

  • Gao, Jiayuan;Zhao, Jinbin;He, Chaojie;Zhang, Shuaitao;Li, Fen
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.212-224
    • /
    • 2018
  • For maintaining a reliable and secure power system, this paper describes the design and implement of a single-phase grid-connected inverter with an enhanced phase-locked loop (PLL) and excellent power control performance. For designing the enhanced PLL and power regulator, a full-bridge voltage-controlled inverter (VCI) is investigated. When the grid frequency deviates from its reference values, the output frequency of the VCI is unstable with an oscillation of 2 doubling harmonics. The reason for this oscillation is analyzed mathematically. This oscillation leads to an injection of harmonics into the grid and even causes an output active power oscillation of the VCI. For eliminating the oscillation caused by a PLL, an oscillation compensation method is proposed. With the proposed method, the VCI maintains the original PLL control characteristics and improves the PLL robustness under grid frequency deviations. On the basis of the above analysis, a power regulator with the primary frequency and voltage modulation characteristics is analyzed and designed. Meanwhile, a small-signal model of the power loops is established to determine the control parameters. The VCI can accurately output target power and has primary frequency and voltage modulation characteristics that can provide active and reactive power compensation to the grid. Finally, simulation and experimental results are given to verify the idea.

Compensation of Source Voltage Unbalance and Current Harmonics in Series Active and Shunt Passive Power Filters

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.586-590
    • /
    • 2001
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for hybrid active power filters is proposed, where no low/high-pass filters are used in compensation voltage composition. The phase angle and compensation voltages for source harmonic current and unbalanced voltage components are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. Since a balanced set of the source voltage obtained by scaling the positive sequence components is used as reference values for source current and load voltage, it is possible to eliminate the necessity of low/high-pass filters in the reference generation. Therefore the control algorithm is much simpler and gives more stable performance than the conventional method. In addition, the source harmonic current is eliminated by compensating for the harmonic voltage of the load side added to feedback control of the fundamental component.

  • PDF

3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation (순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • 이승요
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.739-743
    • /
    • 2000
  • With significant development of power electronics technology the proliferation of nonlinear loads such as such as static power converters has deteriorated power quality in power transmission distribution systems. Notably voltage harmonics resulting from current harmonies produced by the nonlinear loads have become a serious problem in many systems Moreover momentary interruptions and voltage sags are responsible for many of the power quality problems found in typical industrial plants. Int his paper proposed 3 phase hybrid series active power filter is not only for harmonic compensation but also for harmonic isolation between supply and load and for voltage regulation and imbalance compensation Through computer simulations we have verified the effectiveness of the proposed system.

  • PDF

A Study on Active Power Filter for Compensation of Power Factor and Harmonic Currents (역률개선 및 고조파 보상을 위한 능동전력필터에 관한 연구)

  • Kim, Y.H.;Kim, J.S.;Kwon, G.H.;Chung, Y.H.;Choi, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1074-1076
    • /
    • 1992
  • By using nonlinear loads in power line, reactive power and harmonics are occured. In this thesis, on the basis of the instantaneous reactive power theory, the calculation method of compensation current commands and the current control characteristics of active power filter using voltage source PWM converter are presented. The calculation of compensation current is performed by DSP within 50 usec. And the Pl control of current is performed by analog devices. The compensations of harmonic current in rectifier loads and unbalance currents are proved by experiments.

  • PDF

3-Phase Hybrid Series Active Power Filter with Instantaneous Voltage Fluctuations Compensation (순간전압변동 보상 기능을 갖는 3상 하이브리드형 직렬 능동전력필터)

  • 한석우;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.5 no.6
    • /
    • pp.544-551
    • /
    • 2000
  • In this paper, 3-phase hybrid series active power filter for compensate current harmonics, voltage drop and unbalanced voltage in the network presented. The proposed system is implemented with a space vector modulation voltage source inverter and a high pass filter connected in parallel to the power system. Here the load is six-pulses thyristor rectifier. The phase angle detected in order to generation reference voltage at load terminal is synchronized with the positive sequence component of the unbalanced source by using symmetrical component transformation. The proposed system has an function harmonic isolation between source and load, voltage regulation, and unbalance compensation. Therefore, what the power system is improved quality, the source current is maintained as a nearly sinusoidal waveform and the load voltage is regulated with a rated voltage regardless of the source variation condition. To verify the validity of the proposed compensating system, the computer simulation and experiment are carried out.

  • PDF

Unified Active Power Filter System of control Power Flow (전력조류 제어에 의한 병.직렬 능동전력필터 시스템)

  • Kang, Min-Hyung;Yang, Lee-Woo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.984-985
    • /
    • 2006
  • This paper presents control algorithms for unified active power filter. The algorithm is based in the performance function. The performance function is defined, and the compensation voltage reference is calculated for harmonics voltage and the compensation current reference is calculated for power factor. The proposed control algorithm can be applied to 3-phase 3-wire system and has a superior compensation characteristics for both harmonic current sources and harmonic voltage sources.

  • PDF

Torque Ripple Reduction Using Torque Compensation Effect of an Asymmetric Rotor Design in IPM Motor

  • Hwang, Yong-Suk;Yoon, Myung-Hwan;Park, Jin-Cheol;Hong, Jung-Pyo
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.266-274
    • /
    • 2017
  • In this paper, torques of two motors are compared by Finite Element Analysis (FEA). One has a symmetric rotor structure and the other has an asymmetric rotor structure. The comparison shows that the asymmetric rotor structured motor has reduced torque ripple compared to the symmetric. The torque of the compared motor models was analyzed by separating into magnetic torque and reluctance torque. Through the analysis of torque component separated, it is shown that the magnetic torque and the reluctance torque compensate each other in the motor with the asymmetric structure rotor. Here "compensate" means decrementing the effect of one or more harmonics. It is shown how this compensation appears between the magnetic torque and the reluctance torque by looking into back electro motive force (emf) and the relative permeability distribution of rotor core.

Capacity Requirement Estimation of Shunt Active Power Filter for Thyristor Converter Load (싸이리스터 컨버터부하에 적용되는 병렬형 능동필터의 적정용량산정)

  • Park, No-Jung;Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.12
    • /
    • pp.715-726
    • /
    • 1999
  • This paper estimates the capacity of shunt type active power filters(APF) for harmonic/reactive power compensation with a thyristor converter load. The base capacity requirement of APF is defined for idealized converter load current waveform and the effect of commutation overlap on the APF capacity is examined. The APF capacity required for reactive power compensation in addition to the harmonic elimination is estimated to give maximum achievable power factor for various operating condition of the partially-loaded thyristor converter. The method of current limit of APF is introduced, and it is shown that the APF capacity can be considerably reduced by deliberately limiting the peak current while maintaining the filtering performance to meet the level std 519 regulation.

  • PDF