• Title/Summary/Keyword: harmonics compensation

Search Result 195, Processing Time 0.028 seconds

Control Method for Reducing the THD of Grid Current of Three-Phase Grid-Connected Inverters Under Distorted Grid Voltages

  • Tran, Thanh-Vu;Chun, Tae-Won;Lee, Hong-Hee;Kim, Heung-Geun;Nho, Eui-Cheol
    • Journal of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.712-718
    • /
    • 2013
  • This paper proposes a control method for reducing the total harmonic distortion (THD) of the grid current of three-phase grid-connected inverter systems when the grid voltage is distorted. The THD of the grid current caused by grid voltage harmonics is derived by considering the phase delay and magnitude attenuation due to the hardware low-pass filter (LPF). The Cauchy-Schwarz inequality theory is used in order to search more easily for the minimum point of the THD. Both the gain and angle of the compensation voltage at the minimum point of the THD of the grid current are derived with the variation of cut-off frequencies of the hardware LPF. Simulation and experimental results show the validity of the proposed control methods.

Control Method of Output of PV Generation System using Shunt Active Filter (엑티브필터를 사용한 태양광 발전시스템의 출력제어)

  • Seong, Nak-Gueon;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.04a
    • /
    • pp.225-227
    • /
    • 2002
  • In this paper, novel concept of a photovoltaic(PV) power generation system adding the function of active filter(AF) is proposed. Even PV power generation system can be treated to a harmonics source for the power distribution system, it is necessary that the function of AF system in grid connected PV power generation system. Active Filters intended for harmonic solutions are expending their functions from harmonic compensation of nonlinear loads into harmonic isolation between utilities and consumer, and harmonic damping throughout power distribution system. So, the PV system combined the function of AF system can be usefully applied in power distribution system. Here, the control strategy of PV-AF system is introduced.

  • PDF

An Improvement of Torque Characteristics of Permanent Magnet Flat Type DC Brushless Motor (영구자석 편평형 DC 브러시레스 전동기의 토오크 특성 개선)

  • 임달호;임태빈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1153-1162
    • /
    • 1990
  • The torque ripple reduction method is studied to improve the speed fluctuation of permanent magnet flat type brushless DC motors. To reduce the torque ripple, this study developed the compensation method of the 5'th harmonics component of air gap flux waveform which pass through the driving coils. 1/2 inch VTR was considered. As the result of this study, we can reduce the torque ripple and the speed fluctuation of the capstan motor about 20% then before and we can obtain not only better characteristics of wow/flutter but more useful capstan motors which can be applied in the multi-function VTRs.

  • PDF

Simulator Development for Evaluating Compensation Performance. of Active Power Filter using Three-Dimensional Space Current Co-ordinate (3차원(次元) 전류좌표(電流座標)에 의한 능동전력(能動電力)필터의 보상성능(補償性能) 평가(評價)를 위한 시뮬레이터 개발(開發))

  • Lim, Young-Choel;Jung, Young-Gook;Na, Suk-Hwan;Choi, Chan-Hak;Chang, Young-Hak
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.337-341
    • /
    • 1994
  • This paper describes an effort to develop a simulator of Active Power Filter (APF) by three dimentional(3-D) space current co-ordinate. System current is represented by 3-D vector composed of three current components - active, reactive and distorted. %THD (%Total Harmonics Distortion) can be converted to height-angle of system current vector and power factor can be defined on 3-D space current co-ordinate without loss of generality. Current of APF and power system can be analyzed by 3-D visualization of current vector trajectory. So, the computer simulation results show that the proposed method by 3-D space current co-ordinate make up for disadvantages of performance evaluation on time / frequency domain.

  • PDF

A Study on Condenser Characteristics at the Series Connection of Condenser and Reactor Under Voltage Unbalance (전압 불평형에서 콘덴서와 리액터의 직렬 연결시의 콘덴서의 특성 분석)

  • Kim, Il-Jung;Kim, Jong-Gyeum;Park, Young-Jeen;Kim, Sung-Hun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.3
    • /
    • pp.325-329
    • /
    • 2010
  • Capacitor has been used principally for the power factor compensation long ago. However now it does as passive filter to reduce harmonics of nonlinear load with reactor. Most of the customer's low-voltage feeder has been designed with approximately balanced and connected at the 3 phase four wire system. But voltage and current unbalance is appeared by the mixing operation of single or three phase load etc. The addition of reactor at the condenser may rise its terminal voltage. Voltage and current values above rating can act on electrical stress on the condenser. In this paper, we calculated and measured that voltage, current and capacity of condenser are changed under the voltage balance. We conclude that magnitude and deviation of phase voltage act on major point of electrical stress.

An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters with LCL Filter (LCL필터를 가진 3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 전향보상기법)

  • Park, Byong-Jun;Choi, Ki-Young;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.214-215
    • /
    • 2013
  • 본 논문은 계통 연계형 인버터 제어에 있어서 계통 임피던스에 의한 계통전압 왜곡을 분석하고 있다. 특히 계통 연계형 인버터의 설계단계에서는 고려되지 않지만, 실제 시스템 구현 시에는 일반적으로 널리 사용되는 저주파트랜스의 누설 인덕턴스에 의한 영향을 살펴보았다. 계통 임피던스에 의해 계통 전압의 왜곡이 발생하고 이로 인해 저차 고조파 성분의 전류가 계통으로 유입되게 되는데, 본 논문에서는 이 저차 고조파에 대해 분석하고, 이를 감쇄시키는 기법을 소개한다. 제안하는 방법은 1.5kW 전압형 인버터의 시물레이션을 통해 검증하였다.

  • PDF

Four Switch Three-Phase Z-Source Active Power Filter (Four-Switch 3상 Z-소스 능동전력필터)

  • Qiu, Xiao-Dong;Jung, Young-Gook;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.224-225
    • /
    • 2013
  • This paper describes the four switch three-phase Z-source active power filter. This novel configuration has many advantages like reduction of cost, switching loss and smaller drive circuit. The paper presents an application of direct current control(DCC) method in a three-phase parallel Z-source active power filter to reduce the harmonics generated by the nonlinear load. The compensation principles and dynamics of the system are discussed in detail. The results show that the proposed control strategy is feasible and efficient.

  • PDF

An Improvement of PWM Method for Single Phase Current Source Type Active Power Filter (단상 전류원형 능동전력필터를 위한 펄스폭 변조법의 개선)

  • 박인규;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.3
    • /
    • pp.254-262
    • /
    • 1990
  • In the active power filter, the PWM method for controlling the power converter plays an important role for the performance and the efficiency of the filter. In this paper, a new PWM method for the single phase current source type active power filter is presented, which is intended particularly for obtaining the maximum efficiency of the compensation. This method is basically based upon the optimized injection method, but in contrast to the existing method, this method adapts the optimized injection method by putting not only the pulse width, but also the pulse position into control variables. By doing this, when the number of pulses per one cycle is N, lower order harmonics up to the Nth order can be completely eliminated by the filter. So, this method is much more efficient than any other existing method. These characteristics are well verified by the computer simulations and the experiments.

  • PDF

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.

Novel Structure of 3-Phase Phase-Locked Loop with Stiffness against Disturbance (외란에 강인한 새로운 구조의 3상 Phase-Locked Loop)

  • Bae Byung-Yeol;Han Byung-Moon;Park Yong-Hee;Cho Yun-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.39-46
    • /
    • 2006
  • PLL is a key item of power converter for power quality compensation and power flow control. This paper proposes a novel 3-phase PLL that is composed of ALC and PI controller. The operational principle was investigated through theoretical approach, and the performance was verified through computer simulations with MATLAB and experimental works with TMS320VC33 DSP board. The proposed 3-phase PLL shows accurate performance under the voltage disturbances such as sag, harmonics. phase-angle jump, and frequency change.