• 제목/요약/키워드: harmonic-to-noise ratio

검색결과 111건 처리시간 0.025초

성대 기능 훈련이 성대결절 환자의 음성개선에 미치는 효과 (The Effect of Vocal Function Exercise on Voice Improvement in Patients with Vocal Nodules)

  • 임혜진;김정규;권도하;박준영
    • 말소리와 음성과학
    • /
    • 제1권2호
    • /
    • pp.37-42
    • /
    • 2009
  • The purpose of the present study was to determine the effect of the management program known as vocal function exercise (VFE) on voice quality. Typical VFE was modified and applied to patients with vocal nodules by controlling intensity of voice and relieving the vocal fold to solve hyperfunctional problems in VFE. Eight female subjects aged between 28 and 54 who had been diagnosed with vocal nodules took part in the study. The patients performed VFEs once a week for eight weeks. Vocal function exercises consist of voice hygiene, respiratory training, phonation training, and glide training. The subjects' voices were analyzed pre and post therapy on the aspects of acoustics, maximum phonation time (MPT), GRBAS, and voice handicap index (VHI). As a result, it was found that fundamental frequency ($F_o$) was significant increased, shimmer decreased remarkably and that noise to harmonic ratio (NHR) lowered obviously in the acoustic parameter. In addition, MPT was increased significantly. The scale of GRBAS indicated significant improvement in grade, roughness, and strained voice. VHI indicated significant improvement in an emotional part. In conclusion, VFE was effective in improving voice quality for patients with vocal nodules.

  • PDF

선분 근사법과 곡선의 적합성을 이용한 피아노 음의 모델링 (Modeling of Piano Sound Using Method of Line-Segment Approximation and Curve Fitting)

  • 임훈;정의필
    • 한국음향학회지
    • /
    • 제19권3호
    • /
    • pp.86-91
    • /
    • 2000
  • 본 논문에서는 피아노 음을 FFT(Fast Fourier Transform)를 이용하여 주파수 영역으로 변환한 후, 크기(magnitude)와 위상(phase)에 대한 특성들을 분석한다. 이 분석한 결과로 크기와 위상을 모델링하여 파라미터를 생성한다. 크기의 특성에서 기본주파수와 고조파 부분은 다른 부분에 비해 크기가 매우 크다. 그래서 이 부분의 모델링은 오차를 줄이기 위해 곡선의 적합성(Curve Fitting) 방법을 이용하였고, 노이즈 부분의 모델링은 기본주파수 전후의 노이즈가 피아노 음색 특성에 중요한 역할을 하고 불규칙하므로 선분 근사법을 이용하였으며, 크기가 작고 완만하게 변하는 나머지 노이즈 부분은 곡선의 적합성을 이용하였다. 위상은 크기에 적응한 방법과 동일하게 적용하였다. 생성된 파라미터로 크기와 위상을 만들어 역변환 FFT를 하면 피아노 원음에 매우 근접한 음을 얻을 수 있다.

  • PDF

성대 결절 환자를 대상으로 한 음성치료의 효과 (The Efficiency of Voice Therapy for the Patients with Vocal Nodules)

  • 표화영;김명상;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제8권2호
    • /
    • pp.178-184
    • /
    • 1997
  • Vocal nodule due to vocal hyperfunction is one of the representative chronic diseases of vocal folds, and it can be cured by surgical movement, and/or voice therapy. The present study is, focusing on the latter, to compare the acoustic and aerodynamic results of the pretreatment with those of posttreatment, and then to investigate the objective date on the efficiency of the voice therapy for the patients with vocal nodules. 11 females(age : 7-49) and 5 males(age : 8-40), total 16 patients wi vocal nodules treated by voice therapy were participated as subjects. Six measurements and comparisons of pretreatment and posttreatment of the results were performed : litter, shimmer, and noise-to-harmonic ratio as acoustic analyses ; maximum phonation time, mean flow rate, and the subtraction of mean flow rate from maximum flow rate as aerodynamic analyses. As a result, 14 of 16 subjects showed improvement at more than 4 of 6 measurements, and in group data, every measurements of posttreatment was improved significantly than the pretreatment. On the whole, the improvement of aerodynamic aspects was more statistically significant than that of acoustic ones.

  • PDF

측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정 (Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems)

  • 이복희;엄주홍;김성원
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권8호
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

목사들의 음성발성에 대한 음향분석학적 특징 (Acoustic and Stroboscopic Characteristics in Clergies)

  • 진성민;박상욱;강현국;이경철;이용배;김보형
    • 대한후두음성언어의학회지
    • /
    • 제9권1호
    • /
    • pp.47-52
    • /
    • 1998
  • Objectives : To compare the objective differences in voice quality and voice problems between clergies and normal male control group. Materials and Methods : The sustained vowel sound of 46 clergies and 40 normal persons were analyzed, using a videostroboscopy and acoustic analyzer. Together with these analyses, a questionnaire associated with current and past voice problems was handed over to the patients. Results : The most common symptom in subjective group was the voice fatigue. Stroboscopic findings in subjective group were as following 23 cases(50%) of pachydermia, 17 cases(37%) of phase difference, 12 cases(25%) of anterior-posterior contracture, 6 cases(13%) of vocal polyp and 3 cases(7%) of vocal nodule. The mean maximal phonation time in clergies was 17.8 seconds and in control group was 19 seconds. litter, pitch perturbation quotient and shimmer were significantly increased in subjective group than in control group(p<0.05), but there were no significant differences between two groups in fundamental frequency, vFo, amplitude perturbation quotient and noise to harmonic ratio. Conclusion : In the clergies using loud and forceful voice, vocal polyp and functional voice disorder findings were frequently noted in stroboscopic examination. litter and shimmer, reflecting the roughness of voice, were increased in acoustic analysis. Therefore, clergies, classified into untrained professional voice users, need professional career guidance and counseling.

  • PDF

Joint Relay Selection and Power Allocation for Two-way Relay Channels with Asymmetric Traffic Requirements

  • Lou, Sijia;Yang, Longxiang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제7권8호
    • /
    • pp.1955-1971
    • /
    • 2013
  • This paper studies relay selection and power allocation for amplify-and-forward (AF) based two-way relay networks (TWRN) with asymmetric traffic requirements (ATR). A joint relay selection and power allocation algorithm is proposed to decrease the outage probability of TWRN with ATR. In this algorithm, two sources exchange information with the help of the relay during two time slots. We first calculate the optimal power allocation parameters based on instantaneous channel state information (CSI), and then derive a tight lower bound of outage probability. Furthermore, we propose a simplified relay selection criterion, which can be easily calculated as harmonic mean of instantaneous channel gains, according to the outage probability expressions. Simulation results verified the theoretical analyses we presented. It is shown that the outage probability of our algorithm improves 3-4dB comparing with that of other existing algorithms, and the lower bound is tight comparing with actual value for the entire signal-to-noise ratio (SNR) region.

Experimental study on a new damping device for mitigation of structural vibrations under harmonic excitation

  • Alih, Sophia C.;Vafaei, Mohammadreza;Ismail, Nufail;Pabarja, Ali
    • Earthquakes and Structures
    • /
    • 제14권6호
    • /
    • pp.567-576
    • /
    • 2018
  • This manuscript introduces a new damping device which is composed of a water tank and a pendulum. The new damping device can be tuned to multiple frequencies. In addition, it has a higher energy dissipation capacity when compared with the conventional Tuned Liquid Dampers (TLDs). In order to evaluate the efficiency of this new damping device a series of free vibration and forced vibration tests were conducted on a scaled down single-story one-bay steel frame. Two different configurations were studied for the mass of the pendulum that included a completely and a partially submerged mass. It was observed that the completely submerged configuration led to 44% higher damping ratio when compared with the conventional TLD. In addition, the completely submerged configuration reduced the peak displacement response of the structure 1.6 times more than the conventional TLD. The peak acceleration response of the structure equipped with the new damping device was reduced twice more than the conventional TLD. It was also found that, when the excitation frequency is lower than the resonance frequency, the conventional TLD performs better than the partially submerged configuration of the new damping device.

HWAW방법을 이용한 지반의 전단파 속도 3-D 영상화 (3-Dimensional Imaging of Shear Wave Velocity in the Soil Site using HWAW Method)

  • 박형춘;황혜진;조성은
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.176-181
    • /
    • 2010
  • The evaluation of shear modulus (or shear wave velocity) profile of the site is very important in various fields of geotechnical engineering. In the field, there exist spatial variations of shear modulus that case uncertainty in the geotechnical analysis or design. So it is necessary to evaluate the spatial variation of shear wave velocities of the soil site. In this study, the HWAW method is applied to the determination of a 3-D Vs map of soil site. The HWAW method, which is based on harmonic wavelet transforms, has been developed to determine phase and group velocities of waves. The HWAW method uses only the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity in order to minimize the effect of the noise. The field testing of this method is relatively simple and fast because only one experimental setup, which consists of one pair of receivers on the surface, is needed using a short receiver spacing setup (1~3m). These characteristics make it possible to determine detailed local Vs profile in the site with lateral Vs variation and to evaluate 3-D Vs map by performing a series of tests on the grid. To estimate the applicability of the proposed method, field tests were performed. Through field applications validity and applicability of the proposed method were verified.

  • PDF

교환수들의 음성발성에 대한 평가 (Objective Measures of Voice Production in Telephone Operators)

  • 진성민
    • 대한후두음성언어의학회지
    • /
    • 제8권1호
    • /
    • pp.38-43
    • /
    • 1997
  • Backgroud : Now a days, most studies for professional voice user have been performed after artificial voice abuse without consideration of environmental and personal factors, and occupational specificity, therefore those studies have some problems. Objectives : To make a basic guideline for the management of untrained professional voice user, practically we ananalyzed the voice of experimental group. Materials and methods : Just after working, the sustained vowel sounds of the 15 female telephone operators (subjective group) and the 20 normal female persons (control group) were analysed, using a history paper, acoustic analyzer and videostroboscopy. Results : The most common symptom in subjective group was dysphonia. Stroboscopic findings in subjective group were as following ; posterior chink 11 cases (73%), incomplete closure 2 cases (13%), anterior chink 1 case (7%). The mean maximal phonation time in telephone operators was 12.8 seconds and in control group was 16.8 seconds. Jitter, pitch pertubation quotient (PPQ), shimmer and amplitude pertubation quotient (ASQ) were significantly increased in subjective group than control group, but there is no difference between two group in fundamental frequency and noise to harmonic ratio. Conclusion : Untrained professional voice user needs professional career guidance and counseling. And when we manage the untrained professional voice user, we should consider specific occupational, personal and environmental factors as well as laryngeal factors.

  • PDF

Low-Power and High-Efficiency Class-D Audio Amplifier Using Composite Interpolation Filter for Digital Modulators

  • Kang, Minchul;Kim, Hyungchul;Gu, Jehyeon;Lim, Wonseob;Ham, Junghyun;Jung, Hearyun;Yang, Youngoo
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권1호
    • /
    • pp.109-116
    • /
    • 2014
  • This paper presents a high-efficiency digital class-D audio amplifier using a composite interpolation filter for portable audio devices. The proposed audio amplifier is composed of an interpolation filter, a delta-sigma modulator, and a class-D output stage. To reduce power consumption, the designed interpolation filter has an optimized composite structure that uses a direct-form symmetric and Lagrange FIR filters. Compared to the filters with homogeneous structures, the hardware cost and complexity are reduced by about half by the optimization. The coefficients of the digital delta-sigma modulator are also optimized for low power consumption. The class-D output stage has gate driver circuits to reduce shoot-through current. The implemented class-D audio amplifier exhibited a high efficiency of 87.8 % with an output power of 57 mW at a load impedance of $16{\Omega}$ and a power supply voltage of 1.8 V. An outstanding signal-to-noise ratio of 90 dB and a total harmonic distortion plus noise of 0.03 % are achieved for a single-tone input signal with a frequency of 1 kHz.