• Title/Summary/Keyword: harmonic-to-noise ratio

Search Result 111, Processing Time 0.026 seconds

A Correlation Study among Acoustic Parameters of MDVP and Dr. Speech (MDVP와 Dr. Speech의 음향학적 측정치에 관한 상관연구)

  • Yoo Jaeyeon;Ahn Jongbok;Jeong Ok-ran;Jang Taeyeoub
    • Proceedings of the KSPS conference
    • /
    • 2002.11a
    • /
    • pp.133-136
    • /
    • 2002
  • The purpose of this study was to determine the correlation between the Average Fundamental Frequency, Fo-Tremor Frequency, Jitter, Shimmer, Amplitude Tremor Intensity Index, and Noise to Harmonic Ratio of MDVP and Fo, Fo Tremor, Jitter, Shimmer, Amp Tremor, HNR, and NNE of Dr. Speech. The Pearson correlation coefficient was used for analysis. The results showed that there was a strong correlation between Fo and Shimmer of both instruments. However, the remaining parameters did not show a significant correlation.

  • PDF

A Study on the Vibration Characteristics of Steel and Plain Weave Composite Cylindrical Shells Combined with Internal Plate Structures (내부판 구조물이 결합된 강 및 평직 복합재료 원통셸의 구조진동 특성 연구)

  • 이영신;최명환
    • Journal of KSNVE
    • /
    • v.9 no.1
    • /
    • pp.149-162
    • /
    • 1999
  • A method for the analysis of free vibrations of steel and plain weave composite cylindrical shells with a longitudinal, interior rectangular plate is developed by using the receptance method. This method is based on the ratio of a deflection (or slope) response to a harmonic force(or moment) at the joint. In this study, after getting the free vibration characteristics of the simply supported plate and shell, the frequency equation of the combined system is obtained by considering the continuity condition at the joint between the plate and the shell. The numerical results are compared with published results and experiment results in order to show the validate of the formulation, and shown that the analytical results agreed with those from other methods. The effects of the location and the thickness of the plate on the natural frequencies are also investigated.

  • PDF

Evaluation of 2D Shear Wave Velocity Imaging of Subground Using HWAW Method (HWAW 기법을 이용한 지반의 2차원 전단파 속도 평가)

  • Kim, Jong-Tae;Park, Hyung-Choon;Bang, Eun-Seok;Park, Heon-Joon;Kim, Dong-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.2
    • /
    • pp.105-114
    • /
    • 2007
  • Two-dimensional imaging of $V_s$ profile becomes more important in Korea because of the large horizontal variation of soil stiffness. To obtain a shear-wave velocity profile in geotechnical practice, various seismic nondestructive investigation methods are being frequently used. In this study, harmonic wavelet analysis of wave (HWAW) method is applied to the determination of $V_s$ profile to overcome some of weaknesses in the existing surface wave methods. HWAW method which is based on time-frequency analysis using harmonic wavelet transform has been developed to determine phase and group velocities of waves. Field testing of this method is relatively simple and fast because one experimental setup which consists of one pair of receivers is needed to determine $V_s$ profile of site. The proposed method uses the signal portion of the maximum local signal/noise ratio to evaluate the phase velocity to minimize the effects of noise, and uses single array inversion which considers receiver locations. Field tests were performed in 2 sites in order to evaluate accuracy of test method and estimate the applicability of 2-D imaging by HWAW method. Through field applications and comparison with other test results, the good accuracy and applicability of the proposed method were verified.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

가중 쳐프 신호를 사용한 초음파 고조파 영상 기법

  • 김동열;이종철;권성재;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.61-72
    • /
    • 2002
  • In this parer, a new harmonic imaging technique is Proposed and evaluated experimentally. In the Proposed method. a weighted chirp signal with a hanning window is transmitted. The RF samples obtained on each array element are individually compressed by correlating with the reference signal defined as the 2nd harmonic component($2f_0$) of a transmitted chirp signal generated in a square-law system. The correlator output will then consist of the compressed version of the $2f_0$ component generated in tissue and the crosscorrelation sequence of the fundamental($f_0$) and 2f$_{0}$components. The Proposed method uses the compressed $2f_0$ component to form an image. for which the crosscorrelation term should be suppressed below at least -50dB. The Proposed method has two process, 2f$_{0}$-correlation and $2f_0$-correlation(PI) . $2f_0$-correlation can successfully eliminate the $f_0$ component with a single transmit-receive events and therefore is more efficient than the conventional Pulse inversion method in terms of the frame rate. 2i)-correlation(Pl) Performs pulse compression after applying pulse inversion method for the 2nd harmonic image with high resolution and SNR. Another advantage of the proposed method is that the SNR of 2nd harmonic imaging can be improved without limitation by increasing the duration of the chirp signal. The proposed method was verified through both the computer simulations and actual experiments .ts .

A New Measurement Method of the Ground Resistance Using a Low-pass Filter in Energized Substations (지역필터를 이용한 수변전실 접지저항의 새로운 측정방법)

  • Lee, Bok-Hui;Eom, Ju-Hong;Lee, Seung-Chil;Kim, Seong-Won;An, Chang-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.8
    • /
    • pp.387-393
    • /
    • 2001
  • This paper describes an advanced measuring method and precise evaluation of the ground resistance for the grounding system of energized substations and power equipments. A grounding system of substations consists of all interconnected grounding connections of grounded conductors, neutral ground wires, underground conductors of distribution lines, cable shields, grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding terminals of equipments, and etc. It is very difficult to measure the accurate ground resistance of the grounding system of high voltage energized substations because of harmonic components caused by switched power supplies or overloads. The conventional fall-of-potential method may be subject to big error if stray ground currents and potentials are present. In this work, to improve the precision in measurements of the ground resistance by eliminating the effects of harmonic components and stray currents and potentials, the investigations of the ground resistance measurement by using a low pass filter in a model energized grounding system were conducted. The accuracy of ground resistance mesurements was evaluated as a function of the ratio of the test signal to noise (S/N). The errors due to the proposed ground resistance measurement method were decreased with increasing S/N and were less than 5[%] as S/N is 10. The proposed ground resistance measurement method appears to be considerably more accurate than the conventional fall-of -potential method. It is allows cancellation of the parasitic resistance of energized grounding systems, to employ the measurement method that allows cancellation of the parasitic effects due to other circulating ground currents and ground potential rises in practical situations.

  • PDF

Feature Extraction Algorithm for Distant Unmmaned Aerial Vehicle Detection (원거리 무인기 신호 식별을 위한 특징추출 알고리즘)

  • Kim, Juho;Lee, Kibae;Bae, Jinho;Lee, Chong Hyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.3
    • /
    • pp.114-123
    • /
    • 2016
  • The effective feature extraction method for unmanned aerial vehicle (UAV) detection is proposed and verified in this paper. The UAV engine sound is harmonic complex tone whose frequency ratio is integer and its variation is continuous in time. Using these characteristic, we propose the feature vector composed of a mean and standard deviation of difference value between fundamental frequency with 1st overtone as well as mean variation of their frequency. It was revealed by simulation that the suggested feature vector has excellent discrimination in target signal identification from various interfering signals including frequency variation with time. By comparing Fisher scores, three features based on frequency show outstanding discrimination of measured UAV signals with low signal to noise ratio (SNR). Detection performance with simulated interference signal is compared by MFCC by using ELM classifier and the suggested feature vector shows 37.6% of performance improvement As the SNR increases with time, the proposed feature can detect the target signal ahead of MFCC that needs 4.5 dB higher signal power to detect the target.

Performance Analysis of Nonlinear Satellite Communication System in the CCI And ACI Interference Channel (간섭채널에서 비선형 위성 통신 시스템의 특성 분석)

  • 박주석;유흥균;김기근;이대일;김도선
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2A
    • /
    • pp.166-173
    • /
    • 2004
  • Satellite communication system uses a high non-linear HPA(high power amplifiers) in the earth station and satellite transponder. Therefore, it is important to consider the nonlinear effect of HPA on the communication system. In this paper, we find the variation of power spectrum density by nonlinearity HPA and the change of harmonic component according to IBO (input back-off). When the BPSK is used for satellite communication system, we analyze BER performance including the external co-channel interference (CCI) and the adjacent channel interference (ACI) resulting from the HPA nonlinearity. BER degrades as ACI magnitude grows up when the uplink SNR, uplink SIR (signal to co-channel interference power ratio) and downlink SIR are constant at some level. In case there is only non-linear HPA in the satellite, it is shown that BER considerably depends on the ACI magnitude ACI. When there are two non-linear HPAs in the both earth station and satellite, much BER degradation results from the CCI and ACI.

Acoustic Characteristics of Patients with Total Laryngectomees via Voice Rehabilitation Techniques (후두적출술 환자의 발성법에 따른 음향학적 특성)

  • Jang, Hyo-Ryung;Shim, Hee-Jeong;Ko, Do-Heung
    • Phonetics and Speech Sciences
    • /
    • v.5 no.4
    • /
    • pp.25-32
    • /
    • 2013
  • This research is aimed at finding the acoustic characteristics of different voice rehabilitation techniques, the electrolaryx (EL), standard esophageal (SE), and tracheoesophageal (TE), used on 17 patients with laryngectomees. The analysis of the voice qualities was achieved using MDVP. In order to compare the acoustic characteristics, patients were asked to produce the vowel /a/ sound. The acoustic analysis included fundamental frequency (f0), jitter, shimmer, and noise-to-harmonic ratio (NHR). The main acoustic results showed no significant statistical differences between the average measurements of SE and TE speakers. It was found that the current study showed the same tendency found in previous studies. There was also a significant difference between SE and EL speakers. On the other hand, there were no significant statistical differences between the average measurements of TE and EL speakers on all acoustic measurements. This research will contribute to establishing a baseline related to speech characteristics in voice rehabilitation for patients with laryngectomees. In future, the present findings and issues should be considered in the context of gender. Specifically, the number of women who are diagnosed with laryngeal cancer continues to rise and their acoustic characteristics may indeed differ from those of men.

Acoustic Analysis of Voice Change According to Extent of Thyroidectomy (갑상선 수술범위에 따른 음성의 음향적 분석)

  • Kang, Young Ae;Koo, Bon Seok
    • Phonetics and Speech Sciences
    • /
    • v.7 no.4
    • /
    • pp.77-83
    • /
    • 2015
  • Voice complication without the laryngeal nerve injury can occur after thyroidectomy. The purpose of this study is to investigate voice changes according to extent of thyroidectomy with acoustic analysis. Thirty-five female patients with papillary thyroid carcinoma took voice evaluation at before and 1 month, and 3 months after thyroidectomy. Acoustic analysis parameters were speaking fundamental frequency(SFF), min $F_0$, max $F_0$, dynamic range $F_0$, jitter, shimmer, noise-to-harmonic ratio(NHR), and Cepstral prominence peak(CPP). Repeated-measured analysis of variance was applied. Time-related voice changes showed significant differences in all parameters except NHR. At 1 month after surgery, voice quality was worse and pitch was decreasing, but voice quality and pitch were improving at 3-month follow-up. Voice changes according to the extent of surgery were in SFF, max $F_0$, and dynamic range $F_0$. Time by surgery-related voice change existed only in min $F_0$. The result showed that the severity of voice complication depended on the extend of thyroidectomy which had a negative impact on $F_0$-related parameters. The deterioration of voice quality at 1 month after thyroidectomy may be affected by the loss of thyroid hormone in the blood. The descent of $F_0$-related parameters may be impacted by laryngeal fixation of surgical site adhesion.