• Title/Summary/Keyword: harmonic peak

Search Result 152, Processing Time 0.026 seconds

Low-Frequency Electromagnetic Leakage Signal Analysis According to Fundamental Operations of Smartphones (스마트폰 기본 동작 모드에 따른 저주파 대역 누설 전자파 신호 특성 분석)

  • Lee, Young-Jun;Park, Heesun;Kwon, YoungHyoun;Lee, Jaeki;Choi, Ji-Eun;Cho, Sangwoo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.9
    • /
    • pp.1108-1119
    • /
    • 2016
  • This paper presents the spectral analysis and radiation pattern of low-frequency electromagnetic(EM) leakage signals according to the fundamental operations of smartphones. The EM leakage signals generated by the activation of four I/O sensor modules such as a touch-screen, a camera, a microphone and a speaker are captured by the commercial near-field magnetic probe with 1cm spatial resolution. The analysis results show that the leakage of the EM wave occurs strongly around the activated I/O sensor modules, AP(Application Processor) and memory modules. Also, the distinguishable frequency characteristic is shown in each spectrum of EM leakage signals.

Control of the Third Harmonics Injected PWM Inverter in Over Modulation Mode (과변조 영역에서의 3고조파 주입형 PWM 인버터 제어)

  • 김영렬
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.1
    • /
    • pp.101-110
    • /
    • 2002
  • A method to control the inverter output voltage lineally in over modulation mode of the third harmonics injected PWM inverter is proposed. The third harmonics injected PWM has a extended linear region compared with the sine PWM. But it still has a maximum voltage about 90% compared with the six step inverter. Therefore, to control the output voltage linearly in over modulation mode, analyzing the relationship between the modulation index and the peak of the fundamental component of the modified reference voltage, we can settle the problem in over modulation mode without iteration. Then we can increase the maximum fundamental component of the third harmonics injected PWM inverter comparative to six-step inverter continuously in over modulation mode. The simulation results of the inverter-induction motor system shows the validity of this method and experimental results prove it.

Visualization of Epidermis and Dermal Cells in ex vivo Human Skin Using the Confocal and Two-photon Microscopy

  • Choi, Sang-Hoon;Kim, Wi-Han;Lee, Yong-Joong;Lee, Ho;Lee, Weon-Ju;Yang, Jung-Dug;Shim, Jong-Won;Kim, Jin-Woong
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.61-67
    • /
    • 2011
  • The confocal laser scanning microscopy and two-photon microscopy was implemented based on a single laser source and an objective lens. We imaged and compared the morphology of identical sites of ex vivo human skin using both microscopes. The back-scattering emission from the sample provided the contrast for the confocal microscopy. The intrinsic autofluorescence and the second harmonic generation were used as the luminescence source for the two-photon microscopy. The wavelength of the Ti:Sapphire laser was tuned at 710 nm, which corresponds to the excitation peak of NADH and FAD in skin tissue. The various cell layers in the epidermis and the papillary dermis were clearly distinguished by both imaging modalities. The two-photon microscopy more clearly visualized the intercellular region and the nucleus of the cell compared to the confocal microscopy. The fibrous structures in the dermis were more clearly resolved by the confocal microscopy. Numerous cells in papillary dermal layer, as deep as $100\;{\mu}m$, were observed in both CLSM and two-photon microscopy. While most previous studies focused on fibrous structure imaging (collagen and elastin fiber) in the dermis, we demonstrated that the combined imaging with the CLSM and two-photon microscopy can be applied for the non-invasive study of the population, distribution and metabolism of papillary dermal cells in skin.

Dynamic analysis of buildings considering the effect of masonry infills in the global structural stiffness

  • de Souza Bastos, Leonardo;Guerrero, Carolina Andrea Sanchez;Barile, Alan;da Silva, Jose Guilherme Santos
    • Coupled systems mechanics
    • /
    • v.8 no.2
    • /
    • pp.169-184
    • /
    • 2019
  • This research work presents a study that aims to assess the dynamic structural behaviour and also investigate the human comfort levels of a reinforced concrete building, when subjected to nondeterministic wind dynamic loadings, considering the effect of masonry infills on the global stiffness of the structural model. In general, the masonry fills most of the empty areas within the structural frames of the buildings. Although these masonry infills present structural stiffness, the common practice of engineers is to adopt them as static loads, disregarding the effect of the masonry infills on the global stiffness of the structural system. This way, in this study a numerical model based on sixteen-storey reinforced concrete building with 48 m high and dimensions of $14.20m{\times}15m$ was analysed. This way, static, modal and dynamic analyses were carried out in order to simulate the structural model based on two different strategies: no masonry infills and masonry infills simulated by shell finite elements. In this investigation, the wind action is considered as a nondeterministic process with unstable properties and also random characteristics. The fluctuating parcel of the wind is decomposed into a finite number of harmonic functions proportional to the structure resonant frequency with phase angles randomly determined. The nondeterministic dynamic analysis clearly demonstrates the relevance of a more realistic numerical modelling of the masonry infills, due to the modifications on the global structural stiffness of the building. The maximum displacements and peak accelerations values were reduced when the effect of the masonry infills (structural stiffness) were considered in the dynamic analysis. Finally, it can be concluded that the human comfort evaluation of the sixteen-storey reinforced concrete building can be altered in a favourable way to design.

Fault Diagnosis of High-Speed Rotating Machinery With Control Moment Gyro for Medium and Large Satellite Using Envelope Spectrum Analysis (포락선 스펙트럼 분석을 이용한 중대형 위성용 제어모멘트자이로의 고속회전체 고장진단)

  • Kang, Jeong-Min;Song, Tae-Seong;Lee, Jong-Kuk;Song, Deok-Ki;Kwon, Jun-Beom;Lee, Il;Seo, Joong-Bo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.6
    • /
    • pp.413-422
    • /
    • 2022
  • In this paper, the fault analysis of the momentum wheel, which is a high-speed rotary machinery of 'Control Moment Gyro' for medium and large satellite, was described. For fault diagnosis, envelope spectrum analysis was performed using Hilbert transformation method and signal demodulation method to find the impact signals periodically generated from amplitude modulated signals. Through this, the fault of the momentum wheel was diagnosed by analyzing whether there was a harmonic component of the rotational frequency and a bearing fault frequency in a specific frequency band with a high peak.

Application Method and EMTP-RV Simulation of Series Resonance Type Fault Current Limiter for Smart Grid based Electrical Power Distribution System (스마트 그리드 배전계통을 위한 직렬 공진형 한류기 적용 방법 및 EMTP-RV 시뮬레이션 연구)

  • Yun-Seok Ko;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.2
    • /
    • pp.361-370
    • /
    • 2024
  • In this paper, a method was studied for applying a series resonant type fault current limiter that can be manufactured at low cost to the smart grid distribution system. First, the impact of the harmonic components of the short-circuit fault current injected into the series resonance circuit of the fault current limiter on the peak value of the transient response was analyzed, and a methodology for determining the steady-state response was studied using percent impedance-based fault current computation method. Next, the effectiveness of the method was verified by applying it to a test distribution line. The test distribution system using the designed current limiter was modeled using EMTP_RV, and a three-phase short-circuit fault was simulated. In the fault simulation results, it was confirmed that the steady-state response of the fault current accurately followed the design target value after applying the fault current limiter. In addition, by comparing the fault current waveform before and after applying the fault current limiter, it was confirmed that the fault current was greatly suppressed, confirming the effect of applying the series resonance type current limiter to the distribution system.

Study for Correlation between Objective and Subjective Voice Parameters in Patients with Dysphonia (발성장애 환자에서 주관적 음성검사와 객관적 음성검사의 연관성 연구)

  • Park, Jung Woo;Kim, Boram;Oh, Jae Hwan;Kang, Tae Kyu;Kim, Dong Young;Woo, Joo Hyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.30 no.2
    • /
    • pp.118-123
    • /
    • 2019
  • Background and Objectives Voice evaluation is classified into subjective tests such as auditory perception and self-measurement, and objective tests such as acoustic and aerodynamic analysis. When evaluating dysphonia, subjective and objective test results do not always match. The purpose of this study was to analyze the relationship between subjective and objective evaluation in patients with dysphonia and to identify meaningful parameters by disease. Materials and Method The total of 322 patients who visited voice clinic from May 2017 to May 2018 were included in this study. Laryngeal lesions were identified using stroboscopy. Pearson correlation test was performed to analyse correlation between subjective tests including GRBAS scale and voice handicap index, and objective tests including jitter, shimmer, noise to harmonic ratio (NHR), cepstral peak prominence (CPP), maximal phonation time (MPT), mean flow rate, and subglottic pressure. Results In vocal nodule and sulcus vocalis, among GRBAS system, grade and breathiness showed good correlation with CPP, and roughness showed good correlation with jitter or shimmer. In unilateral vocal cord paralysis (UVCP), grade and breathiness showed a very good correlation with CPP, and also good correlation with jitter, shimmer, NHR, and MPT. Also asthenia showed good correlation with CPP and MPT. Vocal polyp has a limited association with other diseases. Conclusion In patients with dysphonia, grade and breathiness showed good correlation with CPP, jitter, and shimmer, and reflect the state of voice change well especially in UVCP, CPP, and MPT.

An Innovative Solution for the Power Quality Problems in Induction Motor by Using Silica and Alumina Nano Fillers Mixed Enamel for the Coatings of the Windings

  • Mohanadasse, K.;Sharmeela, C.;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1621-1625
    • /
    • 2015
  • Power quality has always been a concern of power engineers. Certainly an argument can be successfully made that most parts of power engineering have the ultimate objective to improve power quality. AC motors were widely used in industrial and domestic applications. Generally, AC motors were of two types: Induction and Synchronous motors. In motor many parameters like different load cycling, switching, working in hot weather and unbalances creates harmonics which creates major reasons for temperature rise of the motors. Due to high peak value of voltage, harmonics can weaken insulation in cables, windings and capacitors and different electronic components. Higher value of harmonics increase the motor current and decrease the power factor which will reduce the life time of the motor and increase the overall rating of all electrical equipments. Harmonics reduction of all the motors in India will save more power. Coating of windings of the motor with nano fillers will reduce the amount of harmonics in the motor. Based on the previous project works, actions were taken to use the enamel filled with various nano fillers for the coating of the windings of the different AC motors. Ball mill method was used to convert the micro particles of Al2O3, SiO2, TiO2, ZrO2 and ZnO into nano particles. SEM, TEM and XRD were used to augment the particle size of the powder. The synthesized nano powders were mixed with the enamel by using ultrasonic vibrator. Then the enamel mixed with the nano fillers was coated to the windings of the several AC motors. Harmonics were measured in terms of various indices like THD, VHD, CHD and DIN by using Harmonic analyzer. There are many other measures and indices to describe power quality, but none is applicable in all cases and in many instances, these indices may hide more than they show. Sometimes power quality indices were used as a basis of comparison and standardization. The efficiency of the motors was increased by 5 – 10 %. The thermal withstanding capacity of the motor was increased by 5º to 15º C. The harmonics of the motors were reduced by 10 – 50%.

Characteristics of Second Harmonic Generation in $LiB_3O_5 $ Crystals Grown by TSSG Method (TSSG 법으로 육성한 $LiB_3O_5 $ 단결정의 제2조화파 발생 특성)

  • 권택용;오학태;주정진;백현호;김정남;윤수인
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.1
    • /
    • pp.74-79
    • /
    • 1994
  • The characteristics of the type I and type II SHG in LiB305 crystals grown by TSSG method have been investigated using 1064 nm beam from a Q-switched Nd:YAG laser. The measured phase matching angles and angular acceptance bandwidths were $\theta_m=90^{\circ}, \phi_m=11.6^{\circ}$, <$\delta\theta_{int}L_{1/2}=3.3^{\circ}-cm^{1/2}, \theta\phi_{int}L=0.27^{\circ}-cm^{1/2}$ for type I SHG and $\theta_m=20^{\circ}, \phi_m=90^{\circ}$, TEX>$\delta\theta_{int}L_=0.65^{\circ}-cm, \theta\phi_{int}L^{1/2}=3.5^{\circ}-cm^{1/2}$ for type II SHG, respectively. Thp. type I NCPM temperature of 1064 nm beam was found to be $149^{\circ}C$ with the temperature bandwidth $\DeltaTL$of $4.8^{\circ}C-cm$. An energy conversion efficiency of about 1.8% with 2.6 mm thick LBO crystal at an incident power of TEX>$171 MW/\textrm{cm}^2$ was demonstrated. The measured $d_{32} was 0.74\pm0.05 pm/V$..

  • PDF

Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations (전동력설비의 운전에 의해 발생되는 자계의 측정과 해석)

  • 이복희;길경석
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.2
    • /
    • pp.58-67
    • /
    • 1995
  • The paper describes the variation of magnetic fields caused by the operation of induction motors. The measuring system consists of the self-integrating magnetic field sensor, amplifier, and active integrator. From the calibration experiments, the frequency bandwidth of the magnetic field measuring system ranges from 20[Hz] to 300[kHz] and sensitivity is 0.234(mV/$\mu\textrm{T}$]. The magnetic fields generated under steady state and starting operations of duction motor are recorded by the proposed measuring system, and the fast Fourier transformation(FFT) of the measured data is performed to analyze the harmonic components. A single pulsed magnetic field is strongly caused by direct starting the induction motor, and its peak value is greater than 5 times as compared with the steady state value. The long transient duration and high intensity originates from the large inductance and dynamic characteristic of the induction motor, During the steady state operation of induction motor, subharmonics of magnetic field components, which depend on the pole number of induction motor, are observed. The lower order power-line harmonics can be inferred from the voltage flicker and current ripple which are derived from the torque fluctuation of induction motor. In the case of the induction motor drived by inverter, the harmonics of magnetic field are much more than those caused by direct starting method and are found generally to increase with decreasing the driving frequency.

  • PDF