Compensation of Source Voltage Unbalance and Current Harmonics in Series Active and Shunt Passive Power Filters

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.586-590
    • /
    • 2001
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for hybrid active power filters is proposed, where no low/high-pass filters are used in compensation voltage composition. The phase angle and compensation voltages for source harmonic current and unbalanced voltage components are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. Since a balanced set of the source voltage obtained by scaling the positive sequence components is used as reference values for source current and load voltage, it is possible to eliminate the necessity of low/high-pass filters in the reference generation. Therefore the control algorithm is much simpler and gives more stable performance than the conventional method. In addition, the source harmonic current is eliminated by compensating for the harmonic voltage of the load side added to feedback control of the fundamental component.

  • PDF

The Harmonic Reduction Design of IPMSM No-load line-line Back-EMF for ISG (ISG용 매입형 영구자석 동기 전동기 무부하 선간 역기전력 고조파 저감설계)

  • Lee, Jin-Gyu;Jung, Jae-Woo;Kim, Sung-Il;Hong, Jung-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.754-755
    • /
    • 2008
  • This paper presents a method for reducing the Total Harmonic Distortion(THD) of line-line back_EMF of the IPMSM with distributed winding under the no-load condition. Firstly, the specific harmonic components of line-line back EMF are reduced considering with winding factor. Secondly, THD of line-line back EMF is minimized according to change of pole angle using by Space harmonic Analysis. Finally, the optimal design for minimizing the THD is conducted using response surface methodology with finite element analysis. The validity of the design method dealt with in this paper is demonstrated by comparison between the THD of optimal model and initial model.

  • PDF

500VA Hybrid filter development for harmonic elimination of a single phase power (단상 전원의 고조파 제거용 500VA급 Hybrid 필터 개발)

  • Park, Jong-Yeon;Lee, Hu-Chan;Lee, Bong-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.249-253
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to absorb harmonic currents of nonlinear loads and can also improve the power factor. They are not often optimal filters because the passive filters are designed with the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. By the experimental results using the proposed system for the 500VA rectifier load, we concluded that the researched hybrid filter is cost effective and the performance is better than the passive filter.

  • PDF

Case Study of Second Harmonic Generation under Nonlinear Load and Second Harmonic Elimination Method Based on Impedance Variation Scheme (비선형 부하 이차 고조파 발생 실증사례 분석 및 임피던스 변동 기법을 통한 이차 고조파 저감 기법)

  • Bang, Heegyun;Kim, Sikyung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.604-611
    • /
    • 2013
  • This paper presents an second harmonic elimination method based on the impedance variation scheme. Through the power quality analysis from the nonlinear loads connected on the power system, the second harmonic problems have been analyzed with a case study analysis and the experiments. In the paper, the second Harmonic generation was simulated with a single phase SCR rectifier and the analytical model is proposed for the second harmonic generation. A novel impedance variation scheme is proposed and analyzed to eliminate the second harmonic. The experiment has been performed on the 60(MVA) industry manufacturing plant. The experimental result demonstrates the proposed impedance variation scheme successfully operate on the 60(MVA) industry manufacturing plant.

Harmonics Modelling for Distribution System (배전시스템 고조파 모델링에 관한 연구)

  • Han, Hyeng-J.;Wang, Yong-P.;Chong, Hyeng-H.;Sung, Byung-H.;Park, Hee-C.;Park, In-P.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.205-207
    • /
    • 2005
  • In this paper, the Point of Common Coupling (PCC) is selected to analyze harmonic characteristic of distribution system by IEC 61000 - 3 - 6 in Electromagnetic Compatibility(EMC). Harmonic voltage and current were measured at the PCC of real distribution system. Harmonic distribution, nonlinear load component and Total Harmonic Distortion(THD) were verified by measurement. The effective and accurate modelling of real distribution system were proved through a analysis of harmonic impedance, voltage and current in steady-state. Harmonic transfer characteristic in distribution system were summarized and investigated through a analysis of harmonic voltage and harmonic current in harmonic current source.

  • PDF

A Power Regulation and Harmonic Current Elimination Approach for Parallel Multi-Inverter Supplying IPT Systems

  • Mai, Ruikun;Li, Yong;Lu, Liwen;He, Zhengyou
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1245-1255
    • /
    • 2016
  • The single resonant inverter is widely employed in typical inductive power transfer (IPT) systems to generate a high-frequency current in the primary side. However, the power capacity of a single resonant inverter is limited by the constraints of power electronic devices and the relevant cost. Consequently, IPT systems fail to meet high-power application requirements, such as those in rail applications. Total harmonic distortion (THD) may also violate the standard electromagnetic interference requirements with phase shift control under light load conditions. A power regulation approach with selective harmonic elimination is proposed on the basis of a parallel multi-inverter to upgrade the power levels of IPT systems and suppress THD under light load conditions by changing the output voltage pulse width and phase shift angle among parallel multi-inverters. The validity of the proposed control approach is verified by using a 1,412.3 W prototype system, which achieves a maximum transfer efficiency of 90.602%. Output power levels can be dramatically improved with the same semiconductor capacity, and distortion can be effectively suppressed under various load conditions.

A Study on the Harmonic Characteristics of SMPS Load in LED Display Board (LED 전광판용 SMPS의 고조파 특성에 관한 연구)

  • Park, Joon-Yeol;Ko, Man-Suk;Jang, Rae-Chang;Choi, Hong-Kyoo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.36-43
    • /
    • 2013
  • The prevalence of electronic devices in our modern life is accompanied with the generation of harmonics caused by the nonlinear characteristic load. Especially, the employment of LED have brought the rapid use of SMPS. SMPS is used for supplying the constant DC electric power to the LED display board, but it has a big problem which gives birth of harmonics causing by its high-speed switching. measurement HIOKI 3196 equipment to solve these harmonics were measured. In this study, we are LED Display Board Load Measuring the impedance response with $X_L$ changes for removing harmonics in the measured. And we adopted the suitable passive filter by the impedance response characteristic obtained in the $X_L$ variation experiments. We are trying to deeply the application of passive harmonic filter characteristics that generation in the LED Display Board through EDSA LED simulation.

Analysis of Reduction Effect of Three Harmonic Currents by Zigzag Wiring of Single Phase Transformer (단상 변압기 지그재그 결선에 의한 3고조파 전류 저감 효과 분석)

  • Kim, Jong-Gyeum;Kim, Ji-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.3
    • /
    • pp.99-104
    • /
    • 2017
  • The three-phase four-wire power distribution system can be used to supply power to single-phase and three-phase loads at the same time. There are linear loads and nonlinear loads as single-phase loads connected to each phase. The nonlinear load generates a harmonic current during the power energy conversion process. In particular, the single-phase nonlinear load has a higher proportion of generation of the third harmonic current than the harmonics of the other orders. In a three-phase four-wire system, the third harmonic current flows through the neutral wire to the power supply side, affecting the power supply side and the line. Furthermore, the magnitude of the current flowing in the neutral line can be higher than the current flowing in the individual phase. If the neutral current is higher than the phase current, the breaker may be blocked. Therefore, it is necessary to reduce the amount of current flowing in the neutral line by harmonics. There is a method of zigzag connecting a single phase transformer by a method of reducing 3 harmonic current. In this study, the method of reducing the magnitude of the three harmonic currents flowing through the zigzag wire by comparing the polarity and the negative polarity characteristics of the single phase transformer was compared through measurement and simulation.

An Enhanced Instantaneous Circulating Current Control for Reactive Power and Harmonic Load Sharing in Islanded Microgrids

  • Lorzadeh, Iman;Abyaneh, Hossein Askarian;Savaghebi, Mehdi;Lorzadeh, Omid;Bakhshai, Alireza;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1658-1671
    • /
    • 2017
  • To address the inaccurate load demand sharing problems among parallel inverter-interfaced voltage-controlled distributed generation (DG) units in islanded microgrids (MGs) with different DG power ratings and mismatched feeder impedances, an enhanced voltage control scheme based on the active compensation of circulating voltage drops is proposed in this paper. Using the proposed strategy, reactive power and harmonic currents are shared accurately and proportionally without knowledge of the feeder impedances. Since the proposed local controller consists of two well-separated fundamental and harmonic voltage control branches, the reactive power and harmonic currents can be independently shared without having a remarkable effect on the amplitude or quality of the DGs voltage, even if nonlinear (harmonic) loads are directly connected at the output terminals of the units. In addition, accurate load sharing can also be attained when the plug-and-play performance of DGs and various loading conditions are applied to MGs. The effects of communication failures and latency on the performance of the proposed strategy are also explored. The design process of the proposed control system is presented in detail and comprehensive simulation studies on a three-phase MG are provided to validate the effectiveness of the proposed control method.

A Case of the Distribution Power System PQMS Construction & Harmonic Voltage Analysis (배전계통 PQM 시스템 구축 및 고조파전압 분석사례)

  • Park, Yong-Up;Lee, Keon-Hang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.108-117
    • /
    • 2010
  • The main contents of this paper are the PQM system construction case and distribution system harmonic voltage analysis. The PQM system has constructed by KEPCO in order to investigate power quality of distribution power system for new power quality standard of KEPCO. In result, we have confirmed that voltage harmonic measurement value of the high voltage contract customer 8 households is suitable the KEPCO harmonic standard tentative plan. And the voltage harmonic value of distribution line end side is not always more high than source side by harmonic current offset effect. In the future, acquired data by season, region, load from the PQMS will be used on the resonable harmonic standard enactment in KEPCO.