• Title/Summary/Keyword: harmonic currents

Search Result 343, Processing Time 0.023 seconds

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.

A Study on the Unbalanced Current Distribution of HTS Power Cable (초전도 전력케이블의 전류 불평형에 관한 연구)

  • Kim, Jae-Ho;Park, Chung-Hwa
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.

Power Quality Analysis and Failure of Earth Leakage Breakers in Plant (공장전기설비에서의 누전차단기 오동작과 전력품질 분석)

  • Lee, S.J.;Yoo, J.G.;Jeon, J.C.;Jeon, H.J.;Heo, H.S.;Choe, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.479-481
    • /
    • 2007
  • This paper presented a actual conditions on a false-tripping of ELB(Earth Leakage Breakers) and an assessment of the harmonics due to non-linear electronic equipment such as personal computers, rectifier, electric furnace and test equipments in plant installations. Actual conditions on a failure of ELB were surveyed and analyzed by making up a question to safety managers of plant installations. Also, power quality measurements such as harmonic currents, voltage and current waveform and current imbalance were made at various plant installations where nuisance tripping of ELB is often occurred. The results of this study can be used in making decisions regarding cause of ELB trip and operating and tripping characteristics test of ELB when subjected to distorted current waveform.

  • PDF

High Pulse SCR Inverter for Utility Interactive Renewable Power Generation System (계통연계형 대체에너지 발전시스템을 위한 고펄스 SCR 인버터)

  • Jung, Jae-Hyuck;Kim, Hyun-Jung;Choi, Se-Wan;Kim, Young-Seok;Won, Chung-Yuen
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.85-89
    • /
    • 2001
  • In this paper, a new line-commutated SCR inverter for renewable power generation system is proposed. The proposed inverter system includes a 6-pulse SCR inverter and an auxiliary circuit. By the proper operation of the auxiliary circuit, the pulse number of the inverter system is increased and the output harmonic currents are reduced. Analysis, control and simulation for 24 pulse operation of the proposed scheme is presented and the experimental results will be provided in the final paper.

  • PDF

Three-Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory (순시 무효전력 이론 기반의 능동전력필터 기능을 가지는 삼상 지-소스 정류기)

  • ANVAR, IBADULLAEV;Hong, Seung-Pyo;Lim, Young-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.365-366
    • /
    • 2015
  • Shunt active power filter is a complete current source which can provide an effective and adjustable solution for elimination of harmonic currents in power system. Its performance depends on strategy employed in reference current generation, control technique and topology of converter used in the design.[1-2]. In this paper Three Phase Six switch Z-source rectifier with active power filtering capability based on instantaneous reactive power theory is described. Thanking to the theory power factor and THD value are significantly improved. Experiment results and conclusions are presented.

  • PDF

Analysis of Current/Vibration Characteristics for Vertical Pump Induction Motors in Power Plant (발전소 입형펌프 전동기의 전류/진동신호 특성 분석)

  • Kim, Yeon-Whan;Lee, Doo-Young;Gu, Jea-Rayng;Bae, Yong-Chae;Lee, Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.400-405
    • /
    • 2005
  • The diagnosis of mechanical load and of power transmission system failures is usually carried out through mechanical signals such as vibration signals, acoustic emissions, motor speed envelope. If the mechanical load comes from an electrical machine the mechanical failures could be detected previously. Mechanical rotor imbalances and rotor eccentricities are reflected in electric, electromagnetic and mechanical quantities. Therefore, many surveillance schemes apply to the Fourier spectrum of a line current in order to monitor the motor condition. Due to the interaction of the currents and voltages, both these current harmonics are also reflected by a single harmonic component in the frequency spectrum of the electric power. Motor Current Signature Analysis is the usuful technique to assess machine electrical condition.

  • PDF

Spatial Distribution and Time Variation of M2 Tide and M4 Tide in the Western Coast of Korea (서해 연안해역에서 M2 분조와 M4 분조의 분포 및 변화)

  • Jung, Tae Sung;Jeong, Jin Kwang
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.4
    • /
    • pp.255-265
    • /
    • 2013
  • In the coastal region of Korea, historical tide harmonic constants were collected. Long-term tides and short-term tides observed by the KHOA were analyzed by a tide harmonic analysis method. Based on the harmonic constants, tidal characteristics such as tide asymmetry in Korean coastal waters were investigated. The harmonic constants obtained from the long-term tide data in the western coast have been used to show the relation between tide variation and reclamation project. $M_2$ amplitudes in the western coast have been decreased and $M_2$ phases were faster. $M_4$ amplitudes also were reduced and $M_4$ phases were faster in overall. In Mokpo and Kunsan tidal nonlinearity is relatively conspicuous. Overall, non-linearity of tidal currents is higher in the tidal channels flowing fast. The tidal non-linearity has increased by the development projects including large reclamation. The flood dominant characteristic in the northern and central part of Korean western coastal waters and the ebb dominant characteristic in the southern part have been intensified. The construction of Saemangeum sea dike has significantly changed the tidal characteristic in Korean western coastal waters.

A Study on the Development of Harmonic Limit Device for Stabilizing Main Circuit Equipment of Train (열차운행 안정화를 위한 주회로 기기의 고조파 제한장치 개발에 관한 연구)

  • Kim, Sung Joon;Chae, Eun Kyung;Kang, Jeong Won
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.8 no.6
    • /
    • pp.853-861
    • /
    • 2018
  • This paper proposes the application of harmonic constraints to address the problems caused by abnormal voltage increases when electric railway vehicles are running. The AC line that supplies the train with power during operation is used to provide electricity of 25kV/60 Hz, but gradually the size and frequency of harmonics involved in the line are varied with the technological evolution of the railroad vehicle electrical equipment. An increase in heat losses due to the failure of the instrument transformer (PT), the main circuit device, which is a serious problem with the recent train safety operation, or to the main displacement voltage. When high frequency components are introduced through low frequency Transformers of the main circuit device, the high intensity of the components is caused by the high intensity of the core and the current flow of the parasitic core is increased, thus generating heat. To solve this problem, the recent adjustment of the sequence has applied artificial NOTCH OFF of the power converter. However, the method of receiving and controlling the OFF signal operates by interaction between the ground and the vehicle's devices, thus it is invalid in the event of failure, and an actual accident is occurring. Therefore, the harmonic currents were required to prevent possible flow of harmonics, and conducted a study to prevent accidental occurrence of train accidents and to verify feasibility of the device through the simulations of the train's experimental analysis and the simulations of the train for safe operation.

New Dead Time Compensation Method in Voltage-Fed PWM Inverter (전압형 PWM 인버터에서의 새로운 데드 타임 보상 기법)

  • Ryu, Ho-Seon;Kim, Bong-Suck;Lee, Joo-Hyun;Lim, Ick-Hun;Hwang, Seon-Hwan;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.395-403
    • /
    • 2006
  • This paper has proposed a new dead time compensation method for a voltage-fed PMW inverter. In the voltage-fed PMW inverter, a voltage distortion is generated by the dead time effect and the nonlinear characteristics of the switching devices. Especially, the distorted voltage causes 5th and 7th harmonics in the stationary phase currents, and 6th harmonic in the synchronous phase currents. As a result, the integrator output of the synchronous PI current regulator has the ripple corresponding to six times of the inverter output frequency. In this paper, the signal of the integrator output of the d-axis current regulator is used as the control signal for the dead time compensation. The experimental and simulation results are presented to verify the validity of the proposed method.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.