• 제목/요약/키워드: harmonic currents

검색결과 343건 처리시간 0.036초

2단계 직접형 전력변환시스템의 최적제어기법 고찰 (Optimal Control Scheme for Two-Stage Direct Power Converter)

  • 조춘호;모동영;이상철;최창영;이건식;김태웅;박귀근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.158-159
    • /
    • 2010
  • Two-Stage Direct Power Converter(TSDPC) has many merits that possible bidirectional power flow, input power factor own control and system using imaginary DC-link. But TSDPC has some demerits that need many switching devices and switching loss. This paper suggest optimal TSDPC control scheme for improvement for switching loss part by changing the space vector approval times. This paper is verified that 9% improvement in switching efficiency and proposed system has lower harmonic of input currents and output voltage.

  • PDF

Digital-Controlled Single-Phase Unified Power Quality Conditioner for Non-linear and Voltage Sensitive Loads

  • Ryoo Hong-Je;Kim Jong-Soo;Kisck Dragos Ovidiu
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권4호
    • /
    • pp.374-381
    • /
    • 2005
  • The ability to provide quality power has become a significant issue in power systems. The main causes of poor power quality are harmonic currents, poor power factor, supply-voltage variations, etc. A technique of achieving both active current distortion compensation, power factor correction and also mitigating the supply-voltage variation (sag or swell) at the load side is presented in this paper. The operation and rating issues of the proposed Single-phase Unified Power Quality Conditioner are also highlighted. To reduce the total cost while simultaneously increasing the performance, the system is fully digitally controlled using the fixed-point TMS320F240 digital signal processor. The performances of the UPQC, which is composed by shunt and series PWM controlled-converters, have been verified on a laboratory prototype.

韓國周邊 海洋表面水溫의 季節的 變化 (Seasonal Variation of Surface Temperatures in the Neighbouring Seas of Korea)

  • 강용규;진명신
    • 한국해양학회지
    • /
    • 제19권1호
    • /
    • pp.31-35
    • /
    • 1984
  • 15년간 (1961∼1975) 182정점에서 정기적으로 관측된 수산진흥원 자료를 조화 분석함으로써 한국주변해양 포면수온의 계절적 변화를 연구하였다. 서해 평균수온 은 동해에서보다 낮으나, 서해수온의 년교차는 동해에서보다 훨씬 크다. 한국주변해양의 최대표면수온은 8월중순부터 9월 초순 사이에 나타난다. 본 논문 에서는 한국주변해양 표면수온의 년변화에 대한 물리적 원인을 규명하고, 특히 태양복사 에너지 뿐만 아니라 해류와 기류에 의한 열의 이류가 표면수온에 미치는 영향을 고찰하였다.

  • PDF

고조파 저감을 위한 다중 레벨 PWM 인버터 (A multilevel PWM Inverter for Harmonics Reduction)

  • 강필순;박성준;김철우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권11호
    • /
    • pp.645-651
    • /
    • 2002
  • In this paper, a multilevel PWM inverter employing a cascaded transformer is presented to reduce the harmonics of output voltage and load currents. The proposed PWM inverter consists of two full-bridge modules and their corresponding transformers. The secondarics of each transformer are series-connected. So continuous output voltage levels can be synthesized from the suitable selection of the turns ratio of trasformer. And it appears an integral ratio to input DC source. Because of the cascaded connection of transformers, output filter inductor is not necessary. The operational principles and analysis are explained, and it is compared with a conventional isolated H-bridge PWM inverter. The validity of proposed multilevel inverter is verified through simulated and experimental waveform and their FFT results.

단락시험용 대전류변압기 돌입전류특성에 관한 연구 (THE STUDY 01 CHARACTERISTICS OF INRUSH CURRENTS FOR HIGH POWER SHORT-CIRCUIT TESTING TRANSFORMER)

  • 노창일;나대열;김선구;정흥수;김원만;이동준;김선호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.695-696
    • /
    • 2006
  • The inrush current of transformer cause saturation effects of recovery voltage for short-circuit power testing. the inrush current depends on the residual flux of the transformer core. when inrush current occurs, it is contains a d.c. component and the high harmonic content of the current are of importance to relay protection of testing circuit. this paper describes of decrease method of inrush current for high power short-circuit testing transformer.

  • PDF

Poling된 실리카 유리의 2차비선형광학효과와 공간전하분극의 관계 (Induced Second Order Optical Nonlinearity in Thermally Poled Silica Glasses)

  • 신동욱
    • 한국세라믹학회지
    • /
    • 제36권12호
    • /
    • pp.1374-1380
    • /
    • 1999
  • The cause of Scond Harmonic Generation (SHG) in thermally poled silica glass is suggested basedon the electrical and dielectric relaxation measurements. The absorption currents as functions of time were measured for various types of silica glasses and analyzed by the theory of Space Charge Polarization. Space charge polarization occurs when an ionic conducting material is subjected to dc electric field with blocking electrode. Thermal poling performed to induce SHG in silica glass is basically identical to the process generating space charge polarization. Hence it was found that gene-ration removal reproduction and temperature dependence of SHG in poled silica is directly related to those of space charge polarization. It turned out that the fundamental parameters governing the SHG in poled silica are charge carrier concentration and mobility. Based on the theory of space charge polarization and experimental results of electrical rela-xation the method to increase the intensity of SHG is proposed.

  • PDF

고조파 영향에 의한 위상 변화가 적은 분류기 (Resistive shunt with low phase angle under harmonic effect)

  • 이진호;박영태;이민명;서진호;장석명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.285-287
    • /
    • 1997
  • An AC shunt with low phase angle has been designed for an AC current measurement, such as currents with harmonics. This $0.2\;{\Omega}$ shunt of 5 A rated current is composed of fifty $10\;{\Omega}$ metal film resistors and applicable to the frequency band of DC to 1 kHz.

  • PDF

Modulated Carrier Control for Single-Phase Active Power Filter

  • Son, Gibong;Kim, Hyejin;Cho, Bo-Hyung
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.218-219
    • /
    • 2013
  • In this paper, an improved modulated carrier control for a single-phase shunt active power filter(SAPF), which eliminates harmonic currents at the ac main drawn by nonlinear loads, is introduced. In contrast to conventional methods, since this control method does not need to generate a current reference for SAPF, only the ac main current is sensed instead of the load current and SAPF current. With the proposed control method, the ac main current is directly controlled to be sinusoidal and in phase with the supplied ac voltage by simply comparing the modulated carrier signal with the ac main current. The operation of the proposed SAPF is analyzed and simulation results verify its performance.

  • PDF

개선된 ZVT AC/DC PFC Boost 컨버터 (Improved ZVT AC/DC PFC Boost Converter)

  • 유종규;김용;배진용;계상범;권순도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.172-175
    • /
    • 2005
  • Recently international regulations governing the amount of harmonic currents(e.g IEC 61000-3-2) became mandatory and active Power factor correction (PFC) pre-regulator circuit became inevitable for the AC/DC converters. Among these topologies, the boost topology represents an optimum solution for a PFC pre-regulation in a high power application. This paper propose improved ZVT(Zero Voltage Transition) AC/DC PFC Boost using the average current control employing a soft-switching technique of the auxiliary switch with a minimum number of components. The conventional ZVT PFC Boost Converter has a disadvantage that the auxiliary switch turns off hard, which influences the overall efficiency and the EMI problem. In this paper, an improved ZVT PFC Boost converter using active snubber is proposed to minimize the switching loss of the auxiliary. The prototype of 100kHz, 640W system was implemented to show the improved performance.

  • PDF

VSI-IM 구동 시스템에 벡터제어를 이용한 전류제어 PWM 방식의 제어특성 (Control Characteristics of Current Controlled PWM Using Vector Control in VSI-IM Drive System)

  • Dong Hwa Chung
    • 전자공학회논문지B
    • /
    • 제28B권12호
    • /
    • pp.38-50
    • /
    • 1991
  • A current-controlled scheme of pulse width modulation voltage source inverter (PWM VSI) has attracted considerable attention due to its fast response with current limit and especially suitable for potentially high performance applications such as AC motor drives and UPS systems. These features yield near-sinusoidal currents in the load with reduced current peaks, lower inverter switching frequency and reduce inverter and load stresses. A high performance current-controlled inverter must have a quick response in transient state and low harmonic current in steady state. This paper compares and shows the controlled-characteristics with hysteresis controller(HC), ramp comparison controller(RCC) and predictive controller(PC) of PWM inverter to control actual current of VSI-IM.

  • PDF