• Title/Summary/Keyword: harmonic cancellation

Search Result 17, Processing Time 0.023 seconds

Gate-Bias Control Technique for Envelope Tracking Doherty Power Amplifier (Envelope Tracking 도허티 전력 증폭기의 Gate-Bias Control Technique)

  • Moon, Jung-Hwan;Kim, Jang-Heon;Kim, Il-Du;Kim, Jung-Joon;Kim, Bum-Man
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.8
    • /
    • pp.807-813
    • /
    • 2008
  • The gate-biases of the Doherty power amplifier are controlled to improve the linearity performance. The linearity improvement mechanism of the Doherty amplifier is the harmonic cancellation of the carrier and peaking amplifier at the output power combining point. However, it is difficult to cancel the harmonic power for the broader power range because the condition for cancelling is varied by power. For the linearity improvement, we have explored the linearity characteristic of the Doherty amplifier according to the input power and gate biases of the carrier and peaking amplifier. To extend the region of harmonic power cancellation, we have injected the proper gate bias to the carrier and peaking amplifier according to the input power levels. To validate the linearity improvement, the Doherty amplifier is designed using Eudyna 10-W PEP GaN HEMT EGN010MKs at 2.345 GHz and optimized to achieve a high linearity and efficiency at an average output power of 33 dBm, backed off about 10 dB from the $P_{1dB}$. In the experiments, the envelope tracking Doherty amplifier delivers a significantly improved adjacent channel leakage ratio performance of -37.4 dBc, which is an enhancement of about 2.8 dB, maintaining the high PAE of about 26 % for the WCDMA 1-FA signal at an average output power of 33 dBm. For the 802.16-2004 signal, the amplifier is also improved by about 2 dB, -35 dB.

Maximum Power Point Tracking Controller Connecting PV System to Grid

  • Ahmed G. Abo-Khalil;Lee Dong-Choon;Choi Jong-Woo;Kim Heung-Geun
    • Journal of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.226-234
    • /
    • 2006
  • Photovoltaic (PV) generators have nonlinear V-I characteristics and maximum power points which vary with illumination level and temperature. Using a maximum power point tracker (MPPT) with an intermediate converter can increase the system efficiency by matching the PV systems to the load. This paper presents a maximum power point tracker based on fuzzy logic and a control scheme for a single-phase inverter connected to the utility grid. The fuzzy logic controller (FLC) provides an adaptive nature for system performance. Also the FLC provides excellent features such as fast response, good performance and the ability to change the fuzzy parameters to improve the control system. A single-phase AC-DC inverter is used to connect the PV system to the grid utility and local loads. While a control scheme is implemented to inject the PV output power to the utility grid at unity power factor and reduced harmonic level. The simulation results have shown the effectiveness of the proposed scheme.

Modular Multilevel Converter Based STATCOM Topology Suitable for Medium-Voltage Unbalanced Systems

  • Pirouz, Hassan Mohammadi;Bina, Mohammad Tavakoli
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.572-578
    • /
    • 2010
  • This paper discusses a transformerless shunt static compensator (STATCOM) based on a modular multilevel converter (MMC). It introduces a new time-discrete appropriate current control algorithm and a phase-shifted carrier modulation strategy for fast compensation of the reactive power and harmonics, and also for the balancing of the three-phase source side currents. Analytical formulas are derived to demonstrate the accurate mechanism of the stored energy balancing inside the MMC. Various simulated waveforms verify that the MMC based STATCOM is capable of reactive power compensation, harmonic cancellation, and simultaneous load balancing, while controlling and balancing all of the DC mean voltages even during the transient states.

Simulation for the analysis of distortion and electrical characteristics of a two-dimensional BJT (2차원 BJT의 전기적 특성 및 왜곡 해석 시뮬레이션)

  • 이종화;신윤권
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.4
    • /
    • pp.84-92
    • /
    • 1998
  • A program was developed to analyze the electrical characteristics and harmonic distrotion in a two-dimensional silicon BJT. The finite difference equations of the small signal and its second and thired harmonics for basic semiconductor equations are formulated treating the nonlinearity and time dependence with Volterra series and Taylor series. The soluations for three sets of simultaneous equations were obtained sequantially by a decoupled iteration method and each set was solved by a modified Stone's algorithm. Distortion magins and ac parameters such as input impedance and current gains are calculated with frequency and load resistance as parameters. The distortion margin vs. load resistancecurves show cancellation minima when the pahse of output voltage shifts. It is shown that the distortionof small signal characteristics can be reduced by reducing the base width, increasing the emitter stripe length and reducing the collector epitaxial layer doping concentration in the silicon BJT structure. The simulation program called TRADAP can be used for the design and optimization of transistors and circuits as well as for the calculation of small signal and distortion solutions.

  • PDF

A FPGA Implementation of Digital Protective Relays for Electrical Power Installation (전력설비를 위한 디지털보호계전기의 FPGA 구현)

  • Kim, Jong-Tae;Shin, Myong-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.2
    • /
    • pp.131-137
    • /
    • 2005
  • Protective relays provide important features to electrical power systems for protecting against faults and consequent short circuits. This research presents a novel VLSI design of the digital protective relay, which overcomes today's uP/DSP-based relays. This design features good cancellation of DC/k-th harmonic components, noticeable not performance and flexible Protection behavior in the minimized core area The proposed design was successfully implemented by a FPGA(Field Programmable Gate Array) device and can concurrently process over 16KSPS at less $0.03[\%]$ error rate.

Nonlinear Tidal Characteristics along the Uldolmok Waterway off the Southwestern Tip of the Korean Peninsula

  • Kang, Sok-Kuh;Yum, Ki-Dai;So, Jae-Kwi;Song, Won-Oh
    • Ocean and Polar Research
    • /
    • v.25 no.1
    • /
    • pp.89-106
    • /
    • 2003
  • Analyses of tidal observations and a numerical model of the $M_2$ and $M_4$ tides in the Uldolmok waterway located at the southwestern tip of the Korean Peninsula are described. This waterway is well known fer its strong tidal flows of up to more than 10 knots at the narrowest part of the channel. Harmonic analysis of the observed water level at five tidal stations reveals dramatic changes in the amplitude and phase of the shallow water constituents at the station near the narrowest part, while survey results show a decreasing trend in local mean sea levels toward the narrow section. It was also observed that the amplitudes of semi-diurnal constituents, $M_2$ and $S_2$ are diminishing toward the narrowest part of the waterway. Two-dimensional numerical modeling shows that the $M_2$ energy flux is dominated by the component coming from the eastern boundary. The $M_2$ energy is inward from both open boundaries and is transported toward the narrow region of the channel, where it is frictionally dissipated or transferred to other constituents due to a strong non-linear advection effect. It is also shown that the $M_4$ generation is strong around the narrow region, and the abrupt decrease in the M4 amplitude in the region is due to a cancellation of the locally generated M4 with the component propagated from open boundaries. The superposition of both propagated and generated M4 contributions also explains the discontinuity of the M4 phase lag in the region. The tide-induced residual sea level change and the regeneration effect of the $M_2$ tide through interaction with $M_4$ are also examined.

Design of an LCL-Filter for Grid-Connected Three-Level Inverter System (계통 연계형 3-레벨 인버터 시스템을 위한 LCL-필터 설계 방법)

  • Park, Joon Young;Kim, Seok-Min;Seo, SeungGyu;Park, Seong-Soo;Lee, Kyo-Beum
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.105-114
    • /
    • 2017
  • This paper proposes a design method of an LCL-filter for grid-tied three-level inverter systems. The demand for three-phase PWM inverters in applications such as wind or solar power generation systems has been increase in recent years. To reduce harmonic components caused by switching operation, such inverters are connected to the grid via an LCL filter. Although there are research results for designing LCL-filter, the modulation method should be fully considered to make the filter perform desired cancellation ability with minimized size. This paper presents the design methodology for an LCL-filter that is optimized for SVM switching operations. The simulation and experimental results verify the validity of the LCL-filter designed with proposed method in this paper.