• Title/Summary/Keyword: hanging method

Search Result 118, Processing Time 0.024 seconds

Development of Sag and Tension Sensitivity Estimation Method for Configuration Control under PPWS Erection in a Suspension Bridge (현수교 PPWS 가설중 형상관리를 위한 PPWS 새그 및 장력민감도 산정법 개발)

  • Jeong, Woon;Seo, Ju Won;Lee, Won Pyo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.5A
    • /
    • pp.255-266
    • /
    • 2012
  • Main cable of a suspension bridge is the important member which shows the overall structure integrity at bridge completion. Configuration of main cable is a free hanging state at cable erection completion and is different from that at bridge completion supporting the dead loads such as hanger, girder, and so on. Accordingly, the configuration control under cable erection is considerably significant because the configuration at cable erection completion has direct influence on that at bridge completion. That is performed by sag adjustments at center, side span and tension adjustments at anchor span. The former needs the sag sensitivity which represents the control quantity of strand length corresponding to that of sag. The latter requires the tension sensitivity which shows the change of strand tension according to that of strand temperature. In this study, the fundamental equations of cable were derived with the assumption of either catenary or parabola shape, the differential-related equations using chain rule on horizontal tension were drawn from those and finally the estimation methods of the sag / tension sensitivity were proposed from both those. The nonlinear numerical analysis flow charts of sag sensitivity based on the catenary equations were proposed and the sag sensitivities grounded on the differential-related equations were compared with the results using them for various parameters of sag change. Also, considering the combinations of sag change parameters, the calculation method of the final variation for the cable sag was suggested. For the real suspension bridge under construction with PPWS method, the sag/tension sensitivity were estimated considering the construction conditions like the change of PPWS length, PPWS temperature, bridge span, etc.. We hope that this study will be a systematic guideline for the configuration control under main cable erection and improved highly by field verification in the real bridge site.

A theoretic study about western traditional wallpaper hanging (서양의 전통도배에 관한 이론적 고찰)

  • Lim, Sun-Yang
    • Archives of design research
    • /
    • v.19 no.2 s.64
    • /
    • pp.207-216
    • /
    • 2006
  • Even though the notion exists that wall paper has got a short durability for interior decoration in terms of paper's nature, it can be the most important element among the modern dosing wall papering because of the variation of the walls visual effect. Wall paper hasn't been preserved well according to the paper's character and official records haven't been done well. So, by studying a case in which a room is maintained well, seeing various commercial samples which were used for an advertisement and reading several booklets it is possible to study historical evidence. In regard to wall paper and Papering. data, the commercial historic nature of the traditional wall papering has been recognized again in order to study the root of the technical and commercial background. In theory, the historic background research of traditional wall paper in the past is said to have established its theoretical system and the development of modern wall papering in the middle of Britain in 18th century. Through the theoretical study of wall papering, the following things have been researched: handling don the method of the traditional wall papering and lining paper, stylization of pattern by using the method of continual linking, subdivision of commercial cost and specialization of wallpaper, handing down the past traditional adhesion method, the origin of string wallpaper, utility of traditional wallpaper and its various abilities, the change from the face to face linking to duplicated linking, the development of DIY products by women's wallpaper selections. Put against other materials, wallpaper remains the most popular and preferable product for managing a wall and provides a decorative, wall dosing technique. This study can estimate the source of wallpapering history in order to create a systemic approach towards the future's wallpaper industry. This is very important data in order to establish a theoretical system of traditional wallpapering according to its historical research about wallpapering skills and its commercial aspect.

  • PDF

An Experimental Study on Isolation System of Aerial Gas Pipeline for Vehicle Vibration (차량진동에 대한 노출가스관의 방진 시스템 개발을 위한 실험적 연구)

  • 박연수;강성후;박선주
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.11 no.5
    • /
    • pp.131-139
    • /
    • 2001
  • In this paper, aerials gas pipeline vibrations due to the passing of vehicles have been measured, and peak values and characteristics of vibration were analyzed. In order to develop isolation system for gas pipeline, six cases with various support condition and hanging method were tested. The hanger used instead of wore rope isolated almost all vibrations transmitted from main beam. In the results of test, we could decrease response of vibration velocity from 49 % to 56 % and response of vertical vibration acceleration from 49 % to 60 %, because hanger instead of wire rope was used and rubber pads instead of wooden shield plates at support positions for Proofing horizontal vibration were used.

  • PDF

Determination of Trace Germanium by Anodic Stripping Polarography (Anodic Stripping Polarograph에 의한 극미량 게르마늄의 분석(II))

  • Choi, Won-Hyung;Lee, Jong-Moo
    • Analytical Science and Technology
    • /
    • v.5 no.1
    • /
    • pp.17-24
    • /
    • 1992
  • Germanium(IV) was determinated in perchloric acid supporting electrolyte solution containing catechol derivates 3.4-dihydroxy benzoic acid, 3.4-dihydroxy benzaldehyde, adrenaline by hanging mercury electrode(HMDE) of anodic stripping polarography. And then to apply this experimental method for determination of germanium(IV) in natural samples. Germanium(IV) was determinated $300{\mu}g/L$ in ginseng and $210{\mu}g/L$ in mineral water.

  • PDF

Fundamental Study of an Integrated Control Method for a Linear Motor Driven Container Crane System

  • An, Sang-Beak;Taniguchi, Yuki;Yamamoto, Shigehiro;Azukizawa, Teruo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.1060-1067
    • /
    • 2009
  • The authors have proposed a linear motor driven container crane system, in which the linear motor to drive trolley chassis is also used to control swaying motion of a hanging container. To utilize the proposed system, it is needed to develop a power saving control system for the linear drive system. In this paper, an integrated control system to minimize required electric power to drive a trolley chassis with the suppressed swaying motion of a hanged container, is proposed. The validity of the proposed control system is investigated by the simulation using Simulink.

EVALUATION OF COMFORT OR PAIN BY VIRTUAL HUMAN IN USING OF SOME PRODUCT

  • Maekawa, Yoshinori;Hasegawa, Bunzo
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2002.05a
    • /
    • pp.34-38
    • /
    • 2002
  • A virtual human which can evaluate Kansei such as comfort, pain, etc. when the virtual human uses some product is developed. In this paper, method of the evaluation of Kansei by the virtual human is presented. The body of our virtual human is modeled as an uniform non-linear elastic one with a skeleton. The deformation of the body on the contact with some product is simulated using a FEM analysis, and by using of the simulated results (load distribution, strain, etc.) on the contact surface the Kansei is predicted. As examples of the application, comfort of buttocks on seating and pain of arm on hanging of bag are shown. This virtual human can apply for the design of virtual products and also the simulation of medical care.

  • PDF

PRELIMINARY X-Ray DIFFRACTION STUDY OF Pseudomonas sp. DJ77 GLUTATHIONE S-TRANSFERASE

  • Park, Heung-Soo;Chung, An-Sik;Ryu, Seong-Eon;Suh, Se-Won;Kim, Young-Chang;Chung, Yong-Je
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1996.07a
    • /
    • pp.20-20
    • /
    • 1996
  • Crystals of a bacterial glutathione S-transferase(pGST) from pseudomonas sp. DJ 77 have been grown by hanging drop method of vapour diffusion from ammonium sulfate solution. The low concentration of polyethylene glycol 400 as additive were found to be essential for the reproducible growth of large single crystal of pGST. (omitted)

  • PDF

Determination of Gallium by differential Pulse Adsorptive Stripping Voltammetry (펄스차이 흡착법김전압전류법에 의한 갈륨 정량)

  • Se Chul Sohn;Tea Yoon Eom
    • Journal of the Korean Chemical Society
    • /
    • v.36 no.6
    • /
    • pp.889-893
    • /
    • 1992
  • A very sensitive adsorptive stripping voltammetric method is studied on the gallium-morin complex at a hanging mercury drop electrode (HMDE) in 0.1 M acetate buffer solution. The effects of various analytical conditions are discussed on the reduction peak current of the adsorbed complex on the suface of HMDE. Interferences by other trace metals and surfactant are also discussed. Detection limit is 1.7 nM of gallium with 60 seconds deposition time, and the relative standard deviation (n = 7) at 4 ${\mu}$g/l gallium is 2.8%.

  • PDF

Inclination and Non-horizontal Error Correction of Magnetic Compass by the Law of Gravity (중력 법칙을 이용한 전자나침반의 경사오차 및 비 수평오차 보정)

  • Park, Gye-Do;Lee, Jang-Myung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.606-611
    • /
    • 2011
  • This paper proposes a correction method concerning the inclination error and non-horizontal error of magnetic compass when magnetic compass is vibrated. This system used the 2-axis variable resistance and pendulum. A pendulum hanging from the 2-axis variable resistance of this system is always maintain the horizontal because of gravity. but these data had some intrinsic error. So we used the low pass filter to solve this problem. So this system can get the accurate azimuth of magnetic compass. In conclusion, These results demonstrate convincingly by applied algorithm of experiment.

Epidural Catheter Malposition in a Failed Epidural Anesthesia Confirmed by Computed Tomography

  • Lee, Se-Jin;Kim, Sang-Ho;Park, Sun-Young;Kim, Mun-Gyu;Jung, Bo-Il;Ok, Si-Young
    • The Korean Journal of Pain
    • /
    • v.24 no.1
    • /
    • pp.44-47
    • /
    • 2011
  • We report a case of failed epidural anesthesia despite successful identification of the epidural space, loss of resistance technique, hanging drop method and drip infusion. This case evaluated the use of computed tomography to confirm epidural catheter position, which showed the catheter accidentally positioned at the T2 lamina. Because epidural anesthesia can even after successful procedure using standardized techniques such as loss of resistance, we recommend performing the procedure under fluoroscopic guidance to improve success rate and patient safety.