Comparison of total energy expenditure between the farming season and off farming season and accuracy assessment of estimated energy requirement prediction equation of Korean farmers

  • Kim, Eun-Kyung;Yeon, Seo-Eun;Lee, Sun-Hee;Choe, Jeong-Sook
    • Nutrition Research and Practice
    • /
    • v.9 no.1
    • /
    • pp.71-78
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: The purposes of this study were to compare total energy expenditure (including PAL and RMR) of Korean farmers between the farming season and off farming season and to assess the accuracy of estimated energy requirement (EER) prediction equation reported in KDRIs. SUBJECTS/METHODS: Subjects were 72 Korean farmers (males 23, females 49) aged 30-64 years. Total energy expenditure was calculated by multiplying measured RMR by PAL. EER was calculated by using the prediction equation suggested in KDRIs 2010. RESULTS: The physical activity level (PAL) was significantly higher (P < 0.05) in the farming season (male $1.77{\pm}0.22$, female $1.69{\pm}0.24$) than the off farming season (male $1.53{\pm}0.32$, female $1.52{\pm}0.19$). But resting metabolic rate was significantly higher (P < 0.05) in the off farming season (male $1,890{\pm}233kcal/day$, female $1,446{\pm}140kcal/day$) compared to the farming season (male $1,727{\pm}163kcal/day$, female $1,356{\pm}164kcal/day$). TEE ($2,304{\pm}497kcal/day$) of females was significantly higher in the farming season than that ($2,183{\pm}389kcal/day$) of the off farming season, but in males, there was no significant difference between two seasons in TEE. On the other hand, EER of male and female ($2,825{\pm}354kcal/day$ and $2,115{\pm}293kcal/day$) of the farming season was significantly higher (P < 0.05) than those ($2,562{\pm}339kcal/day$ and $1,994{\pm}224kcal/day$) of the off farming season. CONCLUSIONS: This study indicates that there is a significant difference in PAL and TEE of farmers between farming and off farming seasons. And EER prediction equation proposed by KDRI 2010 underestimated TEE, thus EER prediction equation for farmers should be reviewed.

A Study of Forecast System for Clear-Air Turbulence in Korea, Part II: Graphical Turbulence Guidance (GTG) System (한국의 청천난류 예보 시스템에 대한 연구 Part II: Graphical Turbulence Guidance (GTG) 시스템)

  • Kim, Jung-Hoon;Chun, Hye-Yeong;Jang, Wook;Sharman, R.
    • Atmosphere
    • /
    • v.19 no.3
    • /
    • pp.269-287
    • /
    • 2009
  • CAT (clear-air turbulence) forecasting algorithm, the Graphical Turbulence Guidance (GTG) system developed at NCAR (national center for atmospheric research), is evaluated with available observations (e.g., pilot reports; PIREPs) reported in South Korea during the recent 5 years (2003-2008, excluding 2005). The GTG system includes several steps. First, 44 CAT indices are calculated in the domain of the Regional Data Assimilation and Prediction System (RDAPS) analysis data with 30 km horizontal grid spacing provided by KMA (Korean Meteorological Administration). Second, 10 indices that performed ten best forecasting scores are selected. Finally, 10 indices are combined by measuring the score based on the probability of detection, which is calculated using PIREPs exclusively of moderate-or-greater intensity. In order to investigate the best performance of the GTG system in Korea, various statistical examinations and sensitivity tests of the GTG system are performed by yearly and seasonally classified PIREPs. Performances of the GTG system based on yearly distributed PIREPs have annual variations because the compositions of indices are different from each year. Seasonal forecasting is generally better than yearly forecasting, because selected CAT indices in each season represent meteorological condition much more properly than applying the selected CAT indices to all seasons. Wintertime forecasting is the best among the four seasonal forecastings. This is likely due to that the GTG system consists of many CAT indices related to the jet stream, and turbulence associated with the jet stream can be activated mostly in wintertime under strong jet magnitude. On the other hand, summertime forecasting skill is much less than other seasons. Compared with current operational CAT prediction system (KITFA; Korean Integrated Turbulence Forecasting System), overall performance of the GTG system is better when CAT indices are selected seasonally.

A Statistical Analysis of Joint Moments Acting on Men Performing a Seated Dynamic Task (앉은 자세에서 동적 작업을 수행할 때 작용하는 관절 모멘트의 통계학적 해석)

  • Jung, Ho-Il;Son, Kwon
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.161-173
    • /
    • 1991
  • A statistical approach was carried out to analyze joint moments acting on the six subjects performing a right-handed seated task. The dynamic task analyzed consisted of moving a hand-held weight of lkg mass back and forth in front of a subject's chest at the shoulder level in an upright seated position. We used experimental data obtained in the Biomechanics Laboratory of the University of Michigan. Based on the acquired data from three trials by each subject, moments were calculated using a 3-dimensional biomechanical model at such articulations as wrist, elbow, shoulder, the third lumbar spine, hip, knee, and ankle joints. The linear correlation and the two way analysis of variance were applied to the calculated joint moments in order to investigate inter-subject and inter-trial varations. The results obtained showed that the largest magnitude and deviation of moment was found at the third lumbar spine, that any linear relationship could not be found between moment and its equivalents attempted in this study, and that the maximum value and deviation of moment acting on each joint were statistically the same for all three trials but those were statistically not the same for all six subjects.

  • PDF

Horizontal Ratio of the Korean University Student's Face and Facial Golden Mask (황금 분할 마스크를 이용한 대학생 안면의 수평적 분석)

  • Lee, Jun Ho;Park, Gun Wook;Kim, Yong Ha
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.514-520
    • /
    • 2008
  • Purpose: Many attempts have been made to describe ideal facial proportions for over two thousands year and constantly lasted till now. Dr. Marquardt has derived supposedly ideal facial proportions from the facial golden mask using golden ratio of 1 : 1.618. On the other hand, facial reducing surgeries such as mandible angle reduction are popularized in Asia because the width of mid and lower face of Korean is recognized to be wider. The purpose is to analyze characters of Korean university students' faces in horizontal plane and establish the objective data for facial width distributions and clinical applications. Methods: We applied the facial golden mask to the photographs in 1000 cases, compared the width of mid and lower face between the facial golden mask and Korean university students' faces. And we first calculated the horizontal ratio(HR) of middle and lower face each for using comparative scale of width, facial golden mask. We divided 1,000 cases into 3 groups by degrees of HR and analyzed data of HR on each groups. Using calculated horizontal ratio, we newly invented the cumulative frequency of distribution graphs in Korean university students' faces. Results: Mean data of HR were over 1.0 in all groups, which means that Korean university students' faces are typically wider than facial golden mask in horizontal planes. And this study was statistically significant(p- value < 0.05). Clinically using the cumulative frequency distributions of Korean university students' face width, we can easily explain changes of facial width to patient after facial reducing surgery and describe the changes into objective data. Conclusion: This study concludes thatKorean university students' faces are wider than facial golden mask is significantly true and the cumulative frequency of distribution graphs are expected to be widely used for comparison of results in facial reducing surgery.

A Study on Pattern Recognition to Compute Guidelines Based on Evidence for Ecological Healing Environment at Agha Khan Hospital in Karachi - Focused on Human Thermal Comfort Model (HTCM), for Karachi, using Climate Consultant Program

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.27-35
    • /
    • 2015
  • Purpose: Healthcare is on the whole a personal and critical service that consumer's use, whereas hospitalization is as a rule painful, because nature nurtures and Sun Light Luminosity for healthcare settings is considered healing. The performance and design of climate responsive buildings such as AKU requires a detailed study of attributes of climate both at micro as well as macro level. The therapeutic value of contact with nature through window view, greenery and landscape is calculated there. Method: A two prong strategy is been devised for this article, at micro level three typical morphologies are analysed by creating same environment of neighboring building on sun shading chart, radiation and temperature range. Since the analysis of local climate helps to determine the design strategies for hospital Healing Environment which is suitable for Karachi climate; in order to track the macro climatic behaviour, a considerable analysis of psychometrics chart for AKU Karachi are designed on Climate Consultant (CC) and analysed by Machine Learning. Climate Consultant proposes different design strategies suitable for Karachi. And on the other hand time wise illumination sources for clinical area which are then measured on psychrometric chart- according to singular space: multi patient admission, secondly: acute ambulatory ward, and tertiary: multi windowed space according to the mushrabiyah and sky light pattern. Result: Our findings support the hypothesis that windowed wall is 75-80% more healing wall; an accelerated evidence was found for healing at macro level if the form of the hospital is designed according to the climatologically preferences, whereas at micro level: the light resource becomes the staff attentiveness determinant. In Conclusion evidence was provided that the actual form of luminosity results consequently in satisfaction while light entering from several set of windows and other sources might be valued if design according to the healing environment. The data added on the sun shading chart to calculate rays entraining into space in patient room equal to 124416.21 Watts/ meter $m^2$ is calculated as precise healing rate-and is confirmed by questionnaire from patients belonging from each clinical stage having different illnesses.

MONTE-CARLO RADIATIVE TRANSFER MODEL OF THE DIFFUSE GALACTIC LIGHT

  • Seon, Kwang-Il
    • Journal of The Korean Astronomical Society
    • /
    • v.48 no.1
    • /
    • pp.57-66
    • /
    • 2015
  • Monte-Carlo radiative models of the diffuse Galactic light (DGL) in our Galaxy are calculated using the dust radiative transfer code MoCafe, which is three-dimensional and takes full account of multiple scattering. The code is recently updated to use a fast voxel traversal algorithm, which has dramatically increased the computing speed. The radiative transfer models are calculated with the generally accepted dust scale-height of 0.1 kpc. The stellar scale-heights are assumed to be 0.1 or 0.35 kpc, appropriate for far-ultraviolet (FUV) and optical wavelengths, respectively. The face-on optical depth, measured perpendicular to the Galactic plane, is also varied from 0.2 to 0.6, suitable to the optical to FUV wavelengths, respectively. We find that the DGL at high Galactic latitudes is mostly due to backward or large-angle scattering of starlight originating from the local stars within a radial distance of r < 0.5 kpc from the Earth. On the other hand, the DGL measured in the Galactic plane is mostly due to stars at a distance range that corresponds to an optical depth of $${\sim_\sim}$$ 1 measured from the Earth. Therefore, the low-latitude DGL at the FUV wavelength band would be mostly caused by the stars located at a distance of $r{\leq}0.5$ kpc and the optical DGL near the Galactic plane mainly originates from stars within a distance range of $1{\leq}r{\leq}2kpc$. We also calculate the radiative transfer models in a clumpy two-phase medium. The clumpy two-phase models provide lower intensities at high Galactic latitudes compared to the uniform density models, because of the lower effective optical depth in clumpy media. However, no significant difference in the intensity at the Galactic plane is found.

A Monitor Unit Verification Calculation in IMRT as a Dosimetry QA

  • Kung, J.H.;Chen, G.T.Y.;Kuchnir, F.T.
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.68-73
    • /
    • 2002
  • In standard teletherapy, a treatment plan is generated with the aid of a treatment planning system, but it is common to perform an independent monitor unit verification calculation (MUVC). In exact analogy, we propose and demonstrate that a simple and accurate MUVC in Intensity Modulated Radiotherapy (IMRT) is possible. We introduce a concept of Modified Clarkson Integration (MCI). In MCI, we exploit the rotational symmetry of scattering to simplify the dose calculation. For dose calculation along a central axis (CAX), we first replace the incident IMRT fluence by an azimuthally averaged fluence. Second, the Clarkson Integration is carried over annular sectors instead of over pie sectors. We wrote a computer code, implementing the MCI technique, in order to perform a MUVC for IMRT purposes. We applied the code to IMRT plans generated by CORVUS. The input to the code consists of CORVUS plan data (e.g., DMLC files, jaw settings, MU for each IMRT field, depth to isocenter for each IMRT field), and the output is dose contribution by individual IMRT field to the isocenter. The code uses measured beam data for Sc, Sp, TPR, (D/Mu)$\_$ref/ and includes effects from MLC transmission, and radiation field offset. On a 266 MHZ desktop computer, the code takes less than 15 sec to calculate a dose. The doses calculated with MCI algorithm agreed within +/- 3% with the doses calculated by CORVUS, which uses a 1cm x 1cm pencil beam in dose calculation. In the present version of MCI, skin contour variations and inhomogeneities were neglected.

  • PDF

Iron Nutritional Status of Female Students in Kangnung National University (강릉대 일부 여대생의 철분영양상태에 관한 연구)

  • 이규희;김은경;김미경
    • Korean Journal of Community Nutrition
    • /
    • v.2 no.1
    • /
    • pp.23-32
    • /
    • 1997
  • To evaluate iron nutritional status of female college students, fasting blood samples were taken from 76 female students of Kangnung National University. Hemoglobin(Hb), hematocrit(Hct), serum iron(Fe), total iron binding capacity(TIBC) and serum ferritin concentrations were measured and transferrin saturation was calculated. Mean values for Hb, Hct, Fe, TIBC, TS and serum freeitin were 13.64$\pm$1.42g/dl, 40.99$\pm$4.31%, 103.0$\pm$33.3$\mu\textrm{g}$/이, 395.3$\pm$9.07$\mu\textrm{g}$/dl, 26.58$\pm$9.07$\%$and 26.76$\pm$17.5ng/ml, respectively. Prevalence of iron deficiency greatly varied by indices from 6.8% when judged by Hct to 26.0$\%$ by serum ferritin concentration. The Hb concentration was positively correlated with hematocrit (r=0.5402), serum iron(r=0.2819) and transferrin saturation(r=0.2777)(p<0.05). on the other hand, serum ferritin concentration showed significantly negative correlation with TIBC(r=-0.3196). Two-day dietary intake records were collected from subjects to estimate mean daily iron intake and bioavailability of dietary iron. Mean daily intake of iron was 13.15mg and heme iron intake was 0.83mg which was 6.4% of total iron intake. Total absorbable iron calculated by the method of Monsen was 1.27mg and bioavailability of dietary iron was 9.6%. In the light of high prevalence of iron deficiency based of serum ferritin concentration and low bioavailability of iron in the diet, guidelines about diet should be made to increase the content and bioavailability of iron in the diet if female college students.

  • PDF

The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images (재구성 알고리즘 변화에 따른 CT 영상의 화질 평가)

  • Han, Dong-Kyoon;Park, Kun-Jin;Ko, Shin-Kwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

Radiotherapy for gastric mucosa-associated lymphoid tissue lymphoma: dosimetric comparison and risk assessment of solid secondary cancer

  • Bae, Sun Hyun;Kim, Dong Wook;Kim, Mi-Sook;Shin, Myung-Hee;Park, Hee Chul;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • v.35 no.1
    • /
    • pp.78-89
    • /
    • 2017
  • Purpose: To determine the optimal radiotherapy technique for gastric mucosa-associated lymphoid tissue lymphoma (MALToma), we compared the dosimetric parameters and the risk of solid secondary cancer from scattered doses among anterior-posterior/ posterior-anterior parallel-opposed fields (AP/PA), anterior, posterior, right, and left lateral fields (4_field), 3-dimensional conformal radiotherapy (3D-CRT) using noncoplanar beams, and intensity-modulated radiotherapy composed of 7 coplanar beams (IMRT_co) and 7 coplanar and noncoplanar beams (IMRT_non). Materials and Methods: We retrospectively generated 5 planning techniques for 5 patients with gastric MALToma. Homogeneity index (HI), conformity index (CI), and mean doses of the kidney and liver were calculated from the dose-volume histograms. Applied the Biological Effects of Ionizing Radiation VII report to scattered doses, the lifetime attributable risk (LAR) was calculated to estimate the risk of solid secondary cancer. Results: The best value of CI was obtained with IMRT, although the HI varied among patients. The mean kidney dose was the highest with AP/PA, followed by 4_field, 3D-CRT, IMRT_co, and IMRT_non. On the other hand, the mean liver dose was the highest with 4_field and the lowest with AP/PA. Compared with 4_field, the LAR for 3D-CRT decreased except the lungs, and the LAR for IMRT_co and IMRT_non increased except the lungs. However, the absolute differences were much lower than <1%. Conclusion: Tailored RT techniques seem to be beneficial because it could achieve adjacent organ sparing with very small and clinically irrelevant increase of secondary solid cancer risk compared to the conventional techniques.