• Title/Summary/Keyword: hand assist device

Search Result 9, Processing Time 0.021 seconds

A Tactilely Transparent Soft Glove with High Grasping Force (높은 파지력을 가지며 촉감을 전달할 수 있는 유연한 글러브)

  • Jeong, Yong-Jun;Kim, Jong-In;Jeon, Hyeong-Seok;Lee, Deok-Won;Kim, Yong-Jae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.12
    • /
    • pp.1011-1020
    • /
    • 2016
  • This paper introduces a tactilely transparent soft glove composed of soft materials and flexible structures. Although it is hard to achieve a high grasping force with conventional grip-assist gloves made from soft material, the proposed glove can exert a high force by using a novel structure. This structure has a triangular shape composed of flexible structural frames, soft fabric, and belts. It can produce grip-assist moment compliantly without harmful force or misalignment with the human fingers. The whole finger part that comes into contact with objects is made of thin and soft fabric in order to facilitate sensation transference. The proposed tactilely transparent soft glove enables the user to manipulate various objects owing to both the softness and high grasping force; it helps lifting heavy weight objects as well as permitting delicate tactile feeling on the palm and fingers. The proposed concept was applied to a two-finger grip-assist device for validation. In addition, the experimental results regarding grasping objects, fingertip force, and grasping force are presented.

A Self-Reconfigurable System of Contents among Smart Devices

  • Ren, Hao;Kim, Paul;Kim, Sangwook
    • Journal of Multimedia Information System
    • /
    • v.2 no.2
    • /
    • pp.223-232
    • /
    • 2015
  • In this system, mobile devices are not independent, they can communicate with each other, one device's change can affect the whole system or other devices. To achieve the above mentioned A Self-Reconfigurable System of Contents, through discover the device and connect process, to establish the connection between the mobile devices. After user assigns two dimension display type, the user can select content to input the system, contents are portioning and broadcast to devices. The system can self-reconfigure contents rapidly and exactly. This technique supports contents self-reconfiguration for devices remove, addition and position exchange. In this paper, when the user uses the hand contacts device, the device sends a signal to assist the system to detection device's position. The system does not need to get accurate devices moving direction, just according to all changed devices position to judge where the devices destination is. This research develops an application according to this technique, and the real machine tests the application using Android platform. Some communication protocols and mathematical modeling methods are proposed. These methods can also be used in other Internet of Things (IoT) fields, such as Drones Navigation, Smart Home, and Informational City management.

Development of a Mouse for Alternative Computer Access Using Smart Device (스마트기기를 이용한 컴퓨터 대체접근 마우스 개발)

  • Jang, U.H.;Hong, W.K.;Kim, C.G.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2014
  • Almost of alternate computer access devices which assist people with disabilities to utilize the computer connected to computer by some cables or installed in as a S/W program. These devices have some spatial limitations to the people with disabilities, it can't guarantee the free and diverse access to the computer. For these reasons, in this paper, an Android-based mouse program for alternative computer access was developed. A people with physical disabilities who has some limitation of hand movements can use it in anywhere and anytime using only the fine motor skill of the upper limbs. The developed device recognizes the user's point touch and transforms it into the location of mouse cursor. The location information transferred to the computer via Bluetooth communication module equipped in smart devices. Also the group scanning method which can reduce the user's fatigue degree was employed and click, double click, drag & drop functions by hand's movements were equipped. The developed device will help the people with disabilities to use computer with brief touch and convenient operation without spatial limitation.

  • PDF

Mobile remote assistant robot using flex sensor and mecanum wheel (플렉스 센서와 메카넘 휠을 사용한 이동식 원격 작업보조 로봇)

  • Yoon, DongKwan;Park, CheolYoung
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.27 no.2
    • /
    • pp.53-59
    • /
    • 2022
  • In this paper, a mobile robot capable of remote control is designed in consideration of the user's various work environments. Specifically, a mobile remote work robot that moves in a predetermined direction and can perform a series of tasks in synchronization with the user's hand movements, and a control system and control method for controlling the robot were proposed. It was implemented using a robot hand and a wheel for movement to assist in tasks such as transporting dangerous goods or heavy goods. In order to evaluate the performance of the developed robot, the maximum weight that can be carried by the robot hand and the movable inclination of the robot were tested, and the test evaluation results satisfied most of the targeted design specifications.

A Comparative Study on UCP 500 and ISP98 as the Governing Law for Standby Letters of Credit (스탠드바이 신용장(信用狀)의 준거법(準據法)으로서의 UCP 500과 ISP98의 비교연구(比較硏究))

  • Park, Seok-Jae
    • THE INTERNATIONAL COMMERCE & LAW REVIEW
    • /
    • v.20
    • /
    • pp.295-315
    • /
    • 2003
  • Since the end of World War II, the standby letters of credit have been used as a surety device, serving as a performance bond and guarantee in the world. UCP has been used a governing rule for standby letters of credit transactions in international commercial transactions. But the UCP may be sufficient for certain simple standbys, it is not fully applicable nor appropriate for standbys - as is recognized in UCP 500 Article 1. On the other hand, the International Standby Practices(ISP98) provide rules of practice drafted specifically for standby letters of credit intended as an alternative to UCP 500. It became effective on January 1, 1999. In addition to restating general rules applicable to all independent undertakings with greater precision than does UCP 500, thereby reducing the possibility of litigation, it addresses issues that commonly arise in standby practice not addressed in UCP 500. UCP 500 is valid and still applies to standby letter of credit "to the extent to which they may be applicable." Since ISP98 and UCP 500 coexist and may be applicable to standby letters of credit by incorporation, applicants, beneficiaries and issuers have a choice. This study will assist all interested parties in establishing the right rules for the right product, for the right standby letters of credit.

  • PDF

A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible (하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구)

  • Kim, Gwang-Ho;Lee, Dong-Woon;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.

INVESTIGATION ON MECHANICAL AND BIO-MECHANICAL PERFORMANCE OF A CENTRIFUGAL BLOOD PUMP (혈액 펌프의 기계적 성능과 생체 역학적 성능에 대한 연구)

  • Chang, M.;Moshfeghi, M.;Hur, N.;Kang, S.;Kim, W.;Kang, S.H.
    • Journal of computational fluids engineering
    • /
    • v.20 no.2
    • /
    • pp.88-95
    • /
    • 2015
  • Blood pump analysis process includes both mechanical and bio-mechanical aspects. Since a blood pump is a mechanical device, it has to be mechanically efficient. On the other hand, blood pumps function is sensitively related to the blood recirculation; hence, bio-factors such as hemolysis and thrombosis become important. This paper numerically investigates the mechanical and bio-mechanical performances of the Rotaflow in the extracorporeal membrane oxygenation(ECMO), Ventricular Assist Device(VAD), and full-load conditions. The operational conditions are defined as(400[mmHg], 5[L/min.]), (100[mmHg], 3[L/min.]), and (600[mmHg], 10[L/min.]) for ECMO, VAD, and full-load conditions, respectively. The results are presented and analyzed from the mechanical aspect via performance curves, and from bio-mechanical aspect via focusing on hemolytic characteristics. Regions of top and bottom cavities show recirculation in both ECMO and VAD condtions. In addition, Eulerian-based calculation of modified index of hemolysis(MIH) has been investigated. The results demonstrate that the VAD condition has the least risk of hemolysis among the others, while the full-load condition has the highest risk.

Color Vision System for Intelligent Rehabilitation Robot mounted on the Wheelchair (휠체어 장착형 지능형 재활 로봇을 위한 칼라 비전 시스템)

  • Song, Won-Kyung;Lee, He-Young;Kim, Jong-Sung;Bien, Zeung-Nam
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.11
    • /
    • pp.75-87
    • /
    • 1998
  • KARES (KAIST Rehabilitation Engineering System) is the rehabilitation robot system in the type of the 6 degrees of freedom robot arm mounted on the wheelchair, in order to assist the independent livelihood of the disabled and the elderly. The interface device for programming and controlling of the robot arm is essential in the rehabilitation robotic system. Specially, in the case of the manual operation of the robot arm, the user has the burden of cognition and the difficulty for the operation of the robot arm. As a remedy, color vision system for the autonomous performance of jobs is proposed, and four basic desired jobs are specified. By mounting the camera in eye-in-hand type, color vision system for KARES is set up. The desired jobs for picking up the target and moving it to the user's face for drinking are successfully performed in real-time at the indoor environment.

  • PDF

A Study on the Development Direction of Medical Image Information System Using Big Data and AI (빅데이터와 AI를 활용한 의료영상 정보 시스템 발전 방향에 대한 연구)

  • Yoo, Se Jong;Han, Seong Soo;Jeon, Mi-Hyang;Han, Man Seok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.11 no.9
    • /
    • pp.317-322
    • /
    • 2022
  • The rapid development of information technology is also bringing about many changes in the medical environment. In particular, it is leading the rapid change of medical image information systems using big data and artificial intelligence (AI). The prescription delivery system (OCS), which consists of an electronic medical record (EMR) and a medical image storage and transmission system (PACS), has rapidly changed the medical environment from analog to digital. When combined with multiple solutions, PACS represents a new direction for advancement in security, interoperability, efficiency and automation. Among them, the combination with artificial intelligence (AI) using big data that can improve the quality of images is actively progressing. In particular, AI PACS, a system that can assist in reading medical images using deep learning technology, was developed in cooperation with universities and industries and is being used in hospitals. As such, in line with the rapid changes in the medical image information system in the medical environment, structural changes in the medical market and changes in medical policies to cope with them are also necessary. On the other hand, medical image information is based on a digital medical image transmission device (DICOM) format method, and is divided into a tomographic volume image, a volume image, and a cross-sectional image, a two-dimensional image, according to a generation method. In addition, recently, many medical institutions are rushing to introduce the next-generation integrated medical information system by promoting smart hospital services. The next-generation integrated medical information system is built as a solution that integrates EMR, electronic consent, big data, AI, precision medicine, and interworking with external institutions. It aims to realize research. Korea's medical image information system is at a world-class level thanks to advanced IT technology and government policies. In particular, the PACS solution is the only field exporting medical information technology to the world. In this study, along with the analysis of the medical image information system using big data, the current trend was grasped based on the historical background of the introduction of the medical image information system in Korea, and the future development direction was predicted. In the future, based on DICOM big data accumulated over 20 years, we plan to conduct research that can increase the image read rate by using AI and deep learning algorithms.