• 제목/요약/키워드: half-power method

검색결과 356건 처리시간 0.026초

토크 리플 저감을 위한 새로운 비대칭 하프-타입 영구자석 매입형 브러시리스 직류 모터 구조 (A Novel Asymmetrical Half-type IPM BLDC Motor Structure for Reducing Torque Ripple)

  • 심요섭;니구치 노보루;히라타 카츠히로
    • 전력전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.134-143
    • /
    • 2016
  • This paper proposes a novel asymmetrical interior permanent magnet (IPM) brushless DC (BLDC) motor structure, which utilizes half-type permanent magnet (PM) configuration and has asymmetrical side gaps (slot next to the PMs) for reducing torque ripples. This structure uses 24% less volume of PMs than conventional IPM BLDC motor with a full set of magnets. The characteristics of the proposed motor are compared with three other half-type IPM BLDC motors through finite elements method (FEM) analysis, and the usefulness of the proposed motor was verified through experimental evaluation on prototypes of the conventional motor and proposed motor under various torque load conditions. This research obtained a high-performance IPM BLDC motor while decreasing manufacturing cost at the same time.

전류제어를 이용한 등기구 전원장치에 관한 연구 (A Study of Lighting Flxtures Power Supply That Use Current Control)

  • 이병선;김영선
    • 전자공학회논문지
    • /
    • 제49권11호
    • /
    • pp.199-204
    • /
    • 2012
  • 지지구 온난화 등과 관련하여 에너지 개발과 절약에 대한 연구가 활발하다. 본 연구에서는 전체 전기에너지 사용의 19%를 차지하는 조명기구 소비전력의 효율적인 절감과 수명연장을 위해 주파수변조와 펄스폭 변조를 혼용한 전류제어 방식의 새로운 형태인 하프브리지형 전원장치를 제안한다. 제안한 전원장치가 갖는 우수성과 안정성에 대해 입증하고 그 특성을 분석 하였다.

Folding 기법을 이용한 전력분석 공격에 대응하는 고속 스칼라 곱셈 (A Fast Scalar Multiplication to Resist again t Power Attacks by Folding the Scalar in Half)

  • 하재철;곽동진;문상재
    • 정보보호학회논문지
    • /
    • 제13권3호
    • /
    • pp.57-64
    • /
    • 2003
  • 최근 스마트 카드와 같은 정보보호 장치에 대한 물리적 공격 중 소비 전력 분석을 통해 비밀키를 알아내는 전력분석 공격이 위협적이다. 본 논문에서는 전력분석 공격 중 단순 전력분석(SPA) 공격 및 차분 전력분석(DPA) 공격에 대응할 수 있는 방안을 분석하고 타원곡선 암호시스템에 대해 스칼라 곱셈의 연산량을 줄일 수 있는 방안을 제안한다. 제안하는 스칼라 곱셈 알고리듬은 DPA 공격을 방어하기 위해 비밀키에 랜덤성을 부여하였으며 SPA 공격에 대응하면서 계산 효율을 높이기 위해 비밀키를 절반으로 folding하는 기법을 사용하였다. 제안 알고리듬은 하나의 사전 계산정보를 이용하여 SPA와 DPA 공격을 방어하면서도 스칼라 곱셈 연산량을 이진 방식에 비해 약 33%정도 개선하였다.

Half-Bridge 직렬 공진형 인버터를 단위인버터로 한 시분할방식 고주파 인버터의 특성해석에 관한 연구 (A Study on Characteristics Analysis of Time Sharing Type High Frequency Inverter Consisting of Three Unit Half-Bridge Serial Resonant Inverter)

  • 조규판;원재선;서철식;배영호;김동희;노채균
    • 조명전기설비학회논문지
    • /
    • 제15권1호
    • /
    • pp.90-97
    • /
    • 2001
  • 본 논문은 고주파 유도가열용 전원에 사용되는 Half-Bridge 직렬 공진형 인버터를 단위인버터로 한 고주파 인버터 회로를 제시하였다. 제안한 인버터의 구동신호 제어기법으로는 아날로그와 디지털 통신에서 신호전송용으로 널리 사용되는 TDM(Time Division Multiplexing) 방식을 응용한 시분할 구동법을 사용하였다. 회로의 해석은 정규화 파라메타를 도입하여 범용성 있게 기술하였고, 인버터 특성은 스위칭 주파수와 제 파라메타에 따라 특성평가를 행하였다. 또한, 이론해석에서 얻은 특성값을 기초로 한 회로 설계 기법의 일 예도 제시하였다. 범용 시뮬레이션 툴인 Pspice를 통해 이론해석의 타당성을 검증하였으며, 향후 유도가열 응용, DC-DC 컨버터 등의 전원 시스템에 응용 가능성을 보여주고 있다.

  • PDF

Hybrid Double Direction Blocking Sub-Module for MMC-HVDC Design and Control

  • Zhang, Jianpo;Cui, Diqiong;Tian, Xincheng;Zhao, Chengyong
    • Journal of Power Electronics
    • /
    • 제19권6호
    • /
    • pp.1486-1495
    • /
    • 2019
  • Dealing with the DC link fault poses a technical problem for an HVDC based on a modular multilevel converter. The fault suppressing mechanisms of several sub-module topologies with DC fault current blocking capacity are examined in this paper. An improved half-bridge sub-module topology with double direction control switch is also designed to address the additional power consumption problem, and a sub-module topology called hybrid double direction blocking sub module (HDDBSM) is proposed. The DC fault suppression characteristics and sub-module capacitor voltage balance problem is also analyzed, and a self-startup method is designed according to the number of capacitors. The simulation model in PSCAD/EMTDC is built to verify the self-startup process and the DC link fault suppression features.

A Real-Time Method for the Diagnosis of Multiple Switch Faults in NPC Inverters Based on Output Currents Analysis

  • Abadi, Mohsen Bandar;Mendes, Andre M.S.;Cruz, Sergio M.A.
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1415-1425
    • /
    • 2016
  • This paper presents a new approach for fault diagnosis in three-level neutral point clamped inverters. The proposed method is based on the average values of the positive and negative parts of normalized output currents. This method is capable of detecting and locating multiple open-circuit faults in the controlled power switches of converters in half of a fundamental period of those currents. The implementation of this diagnostic approach only requires two output currents of the inverter. Therefore, no additional sensors are needed other than the ones already used by the control system of a drive based on this type of converter. Moreover, through the normalization of currents, the diagnosis is independent of the load level of the converter. The performance and effectiveness of the proposed diagnostic technique are validated by experimental results obtained under steady-state and transient conditions.

모발건조기의 전기화재 위험요소에 따른 화재 감정기법 연구 (Study of Fire Appraisal Method According to Electrical Fire Hazards of Hair Dryer)

  • 문현욱;이기연;김동우;길형준;김향곤
    • 조명전기설비학회논문지
    • /
    • 제25권12호
    • /
    • pp.113-118
    • /
    • 2011
  • In this study, investigation and appraisal method for the scene of a fire according to electrical fire hazards of hair dryer which is usually used at living space are presented. Hair dryer is briefly composed of heating part, wind part and control part. Electrical fire hazards of hair dryer are insulation destruction of power cord, ignition by overheat of heating coil, scattering spark on inside dust, overheat of motor by fan shackle, ignition by carelessness of user, and so on. Fire cause by hair dryer can be perceived through investigation about half-disconnection of power cord, contact badness of power plug, verification of heating coil, fan and switch. These results are expected to be utilized effectively in a countermeasure to prevent an electrical fire by hair dryer.

A New Sustain Driving Method for AC PDP : Charge-Controlled Driving Method

  • Kim, Joon-Yub
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제2C권6호
    • /
    • pp.292-296
    • /
    • 2002
  • A new sustain driving method for the AC PDP is presented. In this driving method, the voltage source is connected to a storage capacitor, this storage capacitor charges an intermediate capacitor through LC resonance, and the panel is charged from the intermediate capacitor indirectly. In this way, the current flowing into the AC PDP when the sustain discharge occurs is reduced because the current is indirectly supplied from a capacitor, a limited source of charge. Thus, the input power to the output luminance efficiency is improved. Since the voltage supplied to the storage capacitor is doubled through LC resonance, this method call drive an AC PDP with a voltage source of about half of the voltage necessary in the conventional driving methods. The experiments showed that this charge-controlled driving method could drive ail AC PDP with a voltage source of as low as 107V. Using a panel of the conventional structure, luminous efficiency of 1.28 lm/W was achieved.

새로운 단상 3전위 인버터회로의 구성에 관한 연구 (A Study on Composition of A Novel Single Phase 3 Level Inverter Circuit)

  • 이종수;백종현
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권5호
    • /
    • pp.51-56
    • /
    • 1995
  • The transistors of single phase 3 level PWM Inverter compose output power transistors and neutral point clamping transistors, which are NPN transistors. Waveforms of driving signals for this are PWM waves for power transistors and period operating waves for neutral point clamping transistors, which signals made W-type modulation from rectangular and sine wave. The output power transistors operate at ON-time complementary and neutral point clamping transistors operate at OFF-time complementary respectively. Therefore, each transistors operate in half period at parallel. Characteristics of this inverter circuit is parallel switching method about series switching method of general inverter. As modulation of 3 level drive signals made from full-wave rectifier of sine wave and rectangular wave, which are level wave about 3 level of complementary transistor inverter. So, this circuit composed complementary operation inverter of NPN transistors only compare with PNP-NPN complementary inverter, which have high power 3 level inverter of complementary operation.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF