• 제목/요약/키워드: half-power method

검색결과 356건 처리시간 0.024초

Rogowski Coil 기반의 전류 센싱 회로를 적용한 SiC MOSFET 단락 보호 회로 설계 (Short-circuit Protection Circuit Design for SiC MOSFET Using Current Sensing Circuit Based on Rogowski Coil)

  • 이주아;변종은;안상준;손원진;이병국
    • 전력전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.214-221
    • /
    • 2021
  • SiC MOSFETs require a faster and more reliable short-circuit protection circuit than conventional methods due to narrow short-circuit withstand times. Therefore, this research proposes a short-circuit protection circuit using a current-sensing circuit based on Rogowski coil. The method of designing the current-sensing circuit, which is a component of the proposed circuit, is presented first. The integrator and input/output filter that compose the current-sensing circuit are designed to have a wide bandwidth for accurately measuring short-circuit currents with high di/dt. The precision of the designed sensing circuit is verified on a double pulse test (DPT). In addition, the sensing accuracy according to the bandwidth of the filters and the number of turns of the Rogowski coil is analyzed. Next, the entire short-circuit protection circuit with the current-sensing circuit is designed in consideration of the fast short-circuit shutdown time. To verify the performance of this circuit, a short-circuit test is conducted for two cases of short-circuit conditions that can occur in the half-bridge structure. Finally, the short-circuit shutdown time is measured to confirm the suitability of the proposed protection circuit for the SiC MOSFET short-circuit protection.

연소 후 $CO_{2}$ 포집공정이 적용된 500MWe 석탄화력발전소의 성능 및 경제성평가 (Performance and Economic Analysis of 500 MWe Coal-Fired Power Plant with Post-Combustion $CO_{2}$ Capture Process)

  • 이지현;김준한;이인영;장경룡;심재구
    • Korean Chemical Engineering Research
    • /
    • 제49권2호
    • /
    • pp.244-249
    • /
    • 2011
  • 연소 후 $CO_{2}$ 포집기술이 적용된 500 MWe 석탄화력발전소의 경제성평가를 수행하고 $CO_{2}$ 저감비용(Cost of $CO_{2}$ avoided)을 산출하였다. 본 연구에서 고려된 $CO_{2}$ 포집기술은 이미 상업적으로 적용이 가능하고, 기존의 화력발전에 적용이 용이한 화학 흡수법을 기초로 하였으며 투자비용 산출을 위해 IEA Greenhouse Gas R&D Programme에서 제시하는 데이터를 활용하였다. 또한 $CO_{2}$ 포집공정 중 가장 많은 발전효율 저하를 가져오는 재열기(리보일러)에 투입되는 열에너지(재생에너지)를 대상으로 민감도분석을 수행하고 각각의 경우에서의 $CO_{2}$ 저감비용을 산출하였다. 분석결과 $CO_{2}$ 포집공정에 적용될 흡수제로 MEA(모노에탄올아민)가 사용되고 재생탑에서 필요한 재생에너지가 3.31 GJ/ton$CO_{2}$ 인 경우 발전효율은 $CO_{2}$ 포집설비 설치 전의 41.0에서 31.6%로 9.4% 감소하고 이때의 $CO_{2}$ 저감비용은 43.3 $/ton$CO_{2}$ 로 산출되었다. 그러나, 흡수제 재생에너지를 변수로 한 민감도분석에서 재생에너지가 2.0 GJ/ton$CO_{2}$로 낮아질 경우 $CO_{2}$ 저감비용은 36.7 $/ton$CO_{2}$까지 낮아질 것으로 분석되었다.

압축 유동하에 있는 시멘트 페이스트의 유변학적 거동에 관한 모델링 (Modeling on Rheological Behavior of Cement Paste under Squeeze Flow)

  • 민병현
    • 한국산학기술학회논문지
    • /
    • 제21권9호
    • /
    • pp.405-413
    • /
    • 2020
  • 압축 유동하에서 측정된 시멘트 페이스트의 수직 응력은 변형률의 증가에 따라 변형률이 0.0003에서 0.003 사이 구간인 탄성 고체 구간과 변형률이 0.003에서 0.8 사이 구간인 변형률 경화 구간으로 나누어진다. 두 구간 중 변형률 경화 영역에서 유변학적 특성을 분석하기 위해 모델링 식이 제안되었다. 첫째, 유체 거동의 관점에서, 지수법칙 일관성 지수 m=700 및 멱지수 n=0.2를 갖는 지수법칙 비뉴토니언 모델이 적용되었다. 적용 결과는 탄성 고체 구간을 제외하고는 실험 결과와 좋은 일치를 보여주었다. 둘째, 연성 고체 거동의 관점에서 힘 평형 모델이 적용되었으며, 하중을 측정하는 센서부와 시멘트 페이스트 표면 간의 마찰 계수가 실험데이터에 반구간탐색법을 적용하여 변형률의 다항식으로 도출되었다. 적용 결과는 변형률이 0.003에서 0.3 사이 구간인 중간 영역에서만 실험 결과와 좋은 일치를 보여주었다. 따라서, 압축 유동 하의 시멘트 페이스트의 유변학적 거동은 변형률 경화 구간에서 연성 고체 거동의 관점보다는 지수법칙 비뉴토니언 유체 거동의 관점에서 실험 결과와 더 일치함을 보여주었다.

85~115GHz 전파망원경용 컬러게이트 급전 혼 제작 (Fabrication of the Corrugated Feed Horn for 85~115GHz Radio Telescope System)

  • 손태호;한석태
    • 한국전자파학회논문지
    • /
    • 제19권6호
    • /
    • pp.640-646
    • /
    • 2008
  • 밀리미터파 대역에서 동작하는 컬러게이트 혼 안테나의 설계법을 나타낸다. 컬러게이트 혼 설계에 있어서 가장 중요한 하이브리드 조건을 계산한다. 본 논문에서는 파장이 짧은 밀리미터파에서 평형 하이브리드 모드의 변환과 제작이 가능한 크기의 컬러게이트 프로파일을 구한다. 모드 이론을 적용하여 혼 내부 및 컬러게이트 내 전자계를 유도한다. 혼의 전파 특성은 모드 임피던스 정합과 경계 조건으로부터 계산하고, 혼 개구면 전자계로부터 Kirchhoff-Hyugen 원리를 적용하여 방사 전자계를 구한다. $85{\sim}115GHz$ 대역에서 동작하는 밀리미터파 컬러게이트 혼 안테나를 설계하고, 전기 포밍 방식으로 제작한다. 측정 결과, 동작 주파수 대역에서 1.3:1 이하의 VSWR과 주파수 85, 100 및 110 GHz에서 각각 9.2, 9.16 및 9.02도의 반치각이 측정됨으로써 이론적 결과와 잘 부합되고 있음을 보인다.

진동대 실험에 의한 강재 액체저장탱크의 동특성 분석 (Estimation of Dynamic Properties of Steel Liquid Storage Tank by Shaking Table Test)

  • 최형석;박동욱;김성완;김재민;백은림
    • 한국지진공학회논문집
    • /
    • 제21권4호
    • /
    • pp.153-161
    • /
    • 2017
  • Liquid storage tank is one of the major infrastructures and generally used to store gases, drinking and utilizing water, dangerous fluids, fire water and so on. According to the recent reports and experiences, the tank structures are damaged in many earthquakes due to their low energy dissipating capacity. Therefore, many researchers have been tried to know the dynamic properties of the tanks including liquids. However, vary limited experimental studies are carried out using relatively small tank models. In this study, a series of shaking table tests are performed with maximum 2 m cubic rectangular liquid storage tanks made of steel to measure the natural frequency and estimate damping coefficient of impulsive and convective mode of the tanks. Especially, the damping values under different shapes and excitation methods are estimated by logarithmic decrement method and half power band-pass method and compared with current design code and standards such as ASCE 7, Eurocode 8 and NZS. Test results show that the impulsive mode damping is around 2% which is proposed by general standards and codes but the impulsive mode damping is 0.13% average that is slightly lower than the code recommendation.

전치 증폭기 공유 기법을 이용한 8-bit 10-MSample/s Folding & Interpolation ADC (A 8-bit 10-MSample/s Folding & Interpolation ADC using Preamplifier Sharing Method)

  • 안철민;김영식
    • 전기전자학회논문지
    • /
    • 제17권3호
    • /
    • pp.275-283
    • /
    • 2013
  • 본 논문에서는 8bit 10Ms/s CMOS Folding and Interpolation ADC를 제안한다. 회로에 사용한 구조는 FR(Folding Rate)이 3, NFB(Number of Folding Block)가 4, IR(Interpolation rate)이 8이며, 제안된 전치 증폭기(Preamplifier) 공유 기법을 회로에 사용하여 같은 구조에서 요구하는 전치 증폭기 수를 절반으로 줄여서 전력소모와 유효면적을 줄이도록 설계하였다. 제안된 ADC는 0.35[um] CMOS 디지털 공정을 사용하여 제작하였고, 유효칩 면적은 3.8[$mm^2$] ($1.8[mm]{\times}2.11[mm]$) 이고, 3.3[V], 샘플링 주파수 10[MHz]에서 20[mA]의 DC 전류소모를 나타내었다. INL은 -0.57, +0.61 [LSB], DNL은 -0.4, +0.51 [LSB]으로 측정되었고, 주파수 100[kHz] 정현파 입력신호에서 SFDR은 48.9[dB], SNDR은 47.9[dB](ENOB 7.6b)로 측정되었다.

Evaluation of a New Fine-mapping Method Exploiting Linkage Disequilibrium: a Case Study Analysing a QTL with Major Effect on Milk Composition on Bovine Chromosome 14

  • Kim, JongJoo;Georges, Michel
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제15권9호
    • /
    • pp.1250-1256
    • /
    • 2002
  • A novel fine-mapping method exploiting linkage disequilibrium (LD) was applied to better refine the quantitative trait loci (QTL) positions for milk production traits on bovine chromosome 14 in the pedigree comprising 22 paternal half-sib families of a Black-and-White Holstein-Friesian grand-daughter design in the Netherlands for a total of 1,034 sons. The chromosome map was constructed with the 31 genetic markers spanning 90 Kosambi cM with the average inter-marker distance of 3.5 cM. The linkage analyses, in which the effects of sire QTL alleles were assumed random and the random factor of the QTL allelic effects was incorporated into the Animal Model, found the QTL for milk, fat, and protein yield and fat and protein % with the Lod scores of 10.9, 2.3, 6.0, 25.4 and 3.2, respectively. The joint analyses including LD information by use of multi-marker haplotypes highly increased the evidence of the QTL (Lod scores were 25.1, 20.9, 11.0, 85.7 and 17.4 for the corresponding traits, respectively). The joint analyses including DGAT markers in the defined haplotypes again increased the QTL evidence and the most likely QTL positions for the five traits coincided with the position of the DGAT gene, supporting the hypothesis of the direct causal involvement of the DGAT gene. This study strongly indicates that the exploitation of LD information will allow additional gains of power and precision in finding and localising QTL of interest in livestock species, on the condition of high marker density around the QTL region.

Applications of Hilbert-Huang transform to structural damage detection

  • Chiou, Dung-Jiang;Hsu, Wen-Ko;Chen, Cheng-Wu;Hsieh, Chih-Min;Tang, Jhy-Pyng;Chiang, Wei-Ling
    • Structural Engineering and Mechanics
    • /
    • 제39권1호
    • /
    • pp.1-20
    • /
    • 2011
  • This study investigates the feasibility of detecting structural damage using the HHT method. A damage detection index, the ratio of bandwidth (RB) is proposed. This index is highly correlated or approximately equal to the change of equivalent damping ratio for an intact structure incurring damage from strong ground motions. Based on an analysis of shaking table test data from benchmark models subjected to adjusted Kobe and El Centro earthquakes, the damage detection index is evaluated using the Hilbert-Huang Transform (HHT) and the Fast Fourier Transform (FFT) methods, respectively. Results indicate that, when the response of the structure is in the elastic region, the RB value only slightly changes in both the HHT and the FFT spectra. Additionally, RB values estimated from the HHT spectra vs. the PGA values change incrementally when the structure response is nonlinear i.e., member yielding occurs, but not in the RB curve from the FFT spectra. Moreover, the RB value of the top floor changes more than those from the other floors. Furthermore, structural damage is detected only when using the acceleration response data from the top floor. Therefore, the ratio of bandwidth RB estimated from the smoothed HHT spectra is an effective and sensitive damage index for detecting structural damage. Results of this study also demonstrate that the HHT is a powerful method in analyzing the nonlinear responses of steel structures to strong ground motions.

에틸렌글리콜 양 조절에 의해 제조된 팔라듐구리 촉매를 이용한 개미산연료전지 성능평가 (Performance Evaluations of Direct Formic Acid Fuel Cell (DFAFC) using PdCu Catalysts Synthesized by Control in Amount of Ethylene Glycol)

  • 양종원;김래현;권용재
    • 한국수소및신에너지학회논문집
    • /
    • 제27권3호
    • /
    • pp.283-289
    • /
    • 2016
  • In this study, electrochemical characterizations of PdCu/C catalysts that are synthesized by modified polyol method are investigated. Most of all, amount of ethylene glycol (EG) that is used as main component for catalyst synthesis is mainly modulated to optimize synthetic condition of the PdCu/C catalyst, For evaluations about catalytic activity and performance of direct formic acid fuel cell (DFAFC), half cell and full cell tests are implemented. As a result, when amount of EG is 4M, catalytic activities of the PdCu/C catalyst such as peak current of formic acid oxidation and active surface area are best, while maximum power density of DFAFC using the optimized PdCu/C catalyst is better than that using commercial Pd/C (30 wt%) by 6%. Based on that, PdCu/C catalyst synthesized by modified polyol method plays a critical role in improving (i) catalytic activity for formic acid oxidation and (ii) DFAFC performance by employing as anodic catalyst.

골격근 심실의 역학 (Skeletal Muscle Ventricle Mechanics)

  • 오중환
    • Journal of Chest Surgery
    • /
    • 제32권5호
    • /
    • pp.428-432
    • /
    • 1999
  • 배경: 전기적인 자극에 의하여 골격근의 피로현상이 극복됨으로써 골격근을 심장보조장치에 이용할 수 있게 되었다. 인공심장이나 심실보조기구는 에너지원의 전원장치가 크고 거추장스러운 단점이 있어 아직 해결해야될 문제이다. 반면 골격근을 이용한 심실보조장치는 에너지원으로 환자 자신의 골격근 수축력을 이용할 수 있는 장점이 있어 이의 임상응용 가능성을 제시하고자 한다. 대상 및 방법: 8예의 광배근을 이용하여 골격근 심실의 모형을 만들었다. 물이 담긴 라텍스 주머니를 골격근이 한바퀴 반 감싸도록 고안하였고 골격근의 수축압력은 연결된 관을 통하여 변환기에 기록되도록 하였다. 전극은 흉배신경 주위에 설치한 후 Itrel 7420 박동기에 연결하였다. 프로그래머로 박동기를 조절하였으며 3.0Volt, cyclic burst, 0.31초 on time, 6.0초 off time의 자극을 주었다. 라텍스 주머니 내에 액체의 양을 25cc 씩 증가시키면서 전부하의 변화에 따른 골격근 심실의 박출량과 압력 및 수축력을 측정하였다. 결과: 골격근 심실의 전부하가 0인 경우 일회박출량은 76.3ml 이고, 전부하가 점차 증가함에 따라 일회박출량이 감소하는 경향을 보였다. 전부하가 75cc 이상이 되면 일회박출량은 70ml 이하로 감소하는 양상을 볼 수 있었다. 압력을 측정한 결과도 전부하가 75cc 이하인 경우 정상의 혈압과 비슷한 107mmHg 이상의 혈압을 보이고 있으나 전부하가 100cc 이상 증가하는 경우 혈압이 100mmHg 이하로 감소하는 것을 볼 수 있었다. 또한 최대의 골격근 수축력은 50cc의 전부하에서 16.6 W/kg의 힘을 분출하였다. 결론: 골격근 심실은 전부하의 변화에 따라 정상 심장보다도 강한 박출량과 압력의 변화를 관찰할 수 있었으며 임상 응용의 가능성을 볼 수 있었다.

  • PDF