• 제목/요약/키워드: half-depth

검색결과 415건 처리시간 0.023초

리브 형상을 갖는 반단면 프리캐스트 판넬의 휨 안전성 평가 연구 (Study on Safety Evaluation of the Half-Depth Precast Deck with RC Rib Pannel for the Flexural Behavior)

  • 황훈희
    • 한국안전학회지
    • /
    • 제34권4호
    • /
    • pp.76-84
    • /
    • 2019
  • The precast pannels are used as formwork in Half-depth precast deck systems. Therefore, it has many advantages, including safe and convenient construction and reduced construction period compared to cast-in-place construction method. In half-depth precast deck systems, the bonding of precast pannels to cast-in place concrete is very important. To enhance the performance of half-depth precast deck system, it is necessary to improve the composite efficiency of the interface or increase the stiffness of the precast pannel to reduce deformation or stress on the interface. In this study, a flexural test of half-depth precast deck system was performed, in which the shear connecting reinforcement was applied to increase the bonding performance at the interface, and the rib shape precast panels were applied to improve stiffness. In addition, the safety and serviceability of these systems were evaluated. Test results show that all of specimens have the required flexural strength under the ultimate strength limit design. It was also evaluated to have sufficient safety for the serviceability of deflection and crack under the serviceability limit design.

리브 형상을 갖는 반단면 프리캐스트 바닥판의 피로 안전성 평가 (Fatigue Safety Evaluation of the Half-Depth Precast Deck with RC Rib Panel)

  • 황훈희
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.103-110
    • /
    • 2019
  • In order to reduce the accidents occurring at construction sites, it is necessary to approach with harmonious measures considering various aspects such as systems, training, facilities, and protection equipments. Suggestion of safe construction method can be a good alternative. In the previous study, the half-depth precast deck with RC rib panel was proposed as an alternative method for safe bridge deck construction, and the performance required by the design code was verified through a four-point bending test. But the actual bridge deck is subjected to the repetitive action of the wheel load rather than the bending condition due to the four-point load. In this study, fatigue test was performed by repeating the wheel load $2{\times}10^6$ cycles to verify the safety of the half-depth precast deck with RC rib panel under actual conditions. As a result, fatigue effect due to repetition of wheel load was not significant in terms of serviceability such as crack width and deflection. In the residual strength test conducted after the fatigue test, the half-depth precast deck with RC rib panel failed by punching shear which is typical failure mode of bridge decks and the residual strength was similar to the punching strength of the RC and PSC bridge decks in spite of the fatigue effects.

롱라인 공법으로 제작한 반단면 프리캐스트 콘크리트 합성 슬래브의 휨강도 평가 (Flexural Strength Estimation of Half-Depth Precast Concrete Composite Slab Manufactured by the Long-Line Method)

  • 최진우;서수홍;주형중;윤순종
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.48-56
    • /
    • 2013
  • 프리텐션 방식을 사용한 PSC 휨부재는 시공이 간편하고 품질관리가 용이하기 때문에 최근 토목분야에서 적용된 사례가 증가하고 있다. 특히, PSC 휨부재의 종류 중 하나인 반단면 프리캐스트 콘크리트 합성 슬래브는 롱라인 공법을 적용하여 최근에 개발되었다. 반단면 프리캐스트 콘크리트 합성 슬래브는 프리캐스트 콘크리트와 현장타설 콘크리트를 합성하여 제작한다. 이 연구에서는 롱라인 공법으로 제작한 프리캐스트 PSC를 적용한 반단면 프리캐스트 콘크리트 합성 슬래브의 프리스트레스 도입 효율과 휨강도에 대한 실험을 실시하고 그 결과를 제시하였다. 롱라인 공법은 한번의 긴장력 도입으로 여러 개의 부재를 생산할 수 있는 장점이 있다. 또한, 프리캐스트 PSC 내에 매입되어 있는 철근의 영향을 고려하여 반단면 프리캐스트 콘크리트 합성 슬래브의 휨강도를 합리적으로 평가할 수 있는 식을 제시하였다.

프리텐션 반두께 바닥판을 갖는 바닥판의 구조성능 평가 (Structural Performance of Pre-tensioned Half-depth Precast Panels)

  • 김동욱;심창수
    • 대한토목학회논문집
    • /
    • 제34권6호
    • /
    • pp.1707-1721
    • /
    • 2014
  • 반단면 프리캐스트 바닥판 공법은 완전 프리캐스트 바닥판 공법과 현장타설 공법의 장점을 절충, 보완한 효과적인 공법으로 공기단축, 시공성 향상을 목적으로 개발된 바닥판이다. 이 논문에서는 프리텐션에 의한 반두께 바닥판의 상세를 제안하였으며, 이에 대한 검증을 위해 실험적 연구와 분석을 수행하였다. 프리텐션이 도입된 반두께 바닥판 실험체와 2경간을 갖는 반두께 바닥판 실험부재 총 5기를 제작하였다. 실험변수로는 프리스트레스 도입크기, 이음부에서의 보강철근유무로써 이에 대한 강도와 변형률, 균열폭을 분석하였다. 단경간 바닥판 실험에서 실험결과는 계산강도에 비해 1.55배 이상 높은 값을 보였고 텐던의 수를 2배 증가 시켜도 휨강도 증가는 10% 수준이고 균열폭 제어에 미치는 영향은 무시할 수준이었다. 2경간 연속 실험부재의 경우는 부재의 정모멘트 및 부모멘트부에서의 강도는 부재의 인장철근과 텐던의 변형률로 항복시점을 파악할 때, 보강철근이 있는 경우 텐던과 인장철근은 보강하지 않은 부재보다 각각 1.2배 1.38배 높은 수준에서 항복하였다. 이번 연구에 의해 검증된 프리텐션 반두께 바닥판은 급속 교체 혹은 급속 시공 현장에 효과적으로 사용될 것으로 기대된다.

하프피어싱에 의한 원형돌기의 성형 및 마킹공정에의 응용 (Forming of Circular Protrusion by Half-Piercing and its Application to Marking of Sheet Metal)

  • 정효기;김종호
    • 소성∙가공
    • /
    • 제21권3호
    • /
    • pp.202-206
    • /
    • 2012
  • Marking is a process that engraves letters or a pattern onto the surface of sheet metal. During marking, it is important to set the proper working conditions for clarity of the letters. In this study a simple case for forming circular protrusions by half-piercing and embossing was initially attempted to determine the working conditions which gave good results with respect to shape accuracy. Corner-radius and flatness of circular protrusions made under several experimental conditions were measured and compared. It is shown that the precision of protrusions by half-piercing is superior to that of embossing, and the clearance between punch and die exerts a strong influence on the shape accuracy rather than the penetration percentage into the thickness of the sheet metal. The marking dies for "SNUT" letters, as an example, by applying the above results were manufactured with four different clearances. The working variables for the experiment were clearance and marking depth. For the very shallow depth of 0.1mm the letters were not clearly read. Letters marked under other conditions were easily distinguished with increasing marking depth. It was confirmed that the half-piercing technique with proper values of the working variables gives good quality for the marking of sheet metal.

반단면 프리캐스트 판넬 이음부의 피로 안전성 및 사용성 평가를 위한 실험적 연구 (An Experimental Study on Evaluation of Fatigue Safety and Serviceability for the Precast Half Deck Panel Joints)

  • 박우진;황훈희;권남승
    • 한국안전학회지
    • /
    • 제34권3호
    • /
    • pp.50-56
    • /
    • 2019
  • Precast members have relatively good quality because they are manufactured in an environment suitable for quality control. A typical precast method in which pre-fabricated segments are assembled in the field requires a joint. Although the joint is a small part of the member, it greatly affects the behavior and quality of the structural member. In the previous study of this paper, the flexural strength of a joint, which is generally applied to half-depth precast deck systems, was verified to have higher strength than the design requirement. In addition, the proposed joint has been verified to have higher strength by reinforcing the connecting rebar. However, even if the flexural strength of the joints is sufficient, excessive deflection or lack of fatigue performance is likely to cause cracks in the half-depth precast deck system. In this study, the serviceability of the half-deck precast panel specimens with joints was evaluated and the experimental verification was conducted to evaluate the fatigue performance of the joint without connection rebar. As a result, the serviceability such as deflection and crack width was found to be higher than the design requirement in all the specimens. In the fatigue test, the fatigue effect was insignificant even in the absence of connection rebar.

반단면 프리캐스트 패널을 적용한 RC 슬래브의 내화성능 평가 (Evaluation of Fire Performance of RC Slabs with Half-Depth Precast Panels)

  • 정철헌;임초롱;김현준;주상훈
    • 대한토목학회논문집
    • /
    • 제30권4A호
    • /
    • pp.391-398
    • /
    • 2010
  • 본 연구에서는 반단면 프리캐스트 패널을 갖는 RC 슬래브에 대해서 비재하 상태에서 ISO-834 화재곡선을 적용한 가열시험을 수행하였다. 가열시험시 PP섬유 혼입되지 않은 실험체에서는 콘크리트의 폭렬이 발생되고, PP섬유가 혼입된 실험체에서는 폭렬이 발생되지 않았다. PP섬유가 혼입된 반단면 프리캐스트 패널을 적용한 RC 슬래브의 발생온도는 PP섬유가 혼입되지 않은 경우보다 낮은 수준을 보였다. 화재 가열실험 후 상온상태로 냉각된 RC 슬래브의 극한하중을 평가하기 위하여 3점 휨실험을 수행하였다. 실험결과, PP섬유가 혼입되지 않은 RC 슬래브는 PP섬유가 혼입된 실험체와 비교해 약 32.5% 정도 극한하중이 감소하는 결과를 보였다. 또한, PP섬유가 혼입된 반단면 프리캐스트 패널을 갖는 RC 슬래브의 극한하중은 PP섬유가 혼입된 전두께 RC 슬래브보다 큰 수준을 보였다. 이상의 결과에서 PP섬유의 혼입과 반단면 프리캐스트 패널 적용시 화재에 대한 저항능력이 향상됨을 확인하였다.

최근 감전재해의 발생특성과 재해원인 분석연구 (A Study on the In-depth Analysis of Cause and Characteristic for Recent Electric Shock Accident)

  • 최상원
    • 한국안전학회지
    • /
    • 제29권2호
    • /
    • pp.7-11
    • /
    • 2014
  • The electric shock victims were predominantly male, and more than half of the victims were found in companies with less than five employees in terms of the scale of company, and also more than half of victims had less than one month of experience for work experience. Considering the category of industry, more than half of the victims were engaged in construction, and considering the subcategory of industries, more than 60% of electric shock victims were found in building and other construction works. This study intended to conduct an in-depth analysis on the cause of electric shock accidents to provide basic data for policy proposing taking into considering the characteristics such as the electric shock path, low voltage, grounding and protection of workers. Also this study conducted an in-depth analysis of electric shock accidents for the past eleven years taking into account the necessity of a long-term plan.

열화상 기술에 의한 M.C 나일론의 내부 결함에 대한 평가 (The Estimation of Defect of Mono Cast Nylon by Infrared Thermography)

  • 한정섭
    • 한국해양공학회지
    • /
    • 제23권2호
    • /
    • pp.81-86
    • /
    • 2009
  • Infrared thermography was used to determine the location, size, and depth of defects under the surface of M.C nylon. Defects were created in a specimen by back-drilling circular holes. These defects were located at the maximum temperature difference that occurred. The sizes of the defects could be calculated by means of the full width at half of the maximum temperature difference. The depth of a defect could be calculated by the peak time and the maximum temperature difference. The maximum temperature difference between a defect and normal part was decreased with the depth of the defect. And the peak time also slowly appeared with the depth of the defect.

X-선 회절에 의한 SS41강의 피로파면해석 (X-ray diffraction study on fatigue fractured surface of SS41 Steel)

  • 오세욱;박수영;김기환;김태형
    • 한국해양공학회지
    • /
    • 제8권1호
    • /
    • pp.114-122
    • /
    • 1994
  • X-ray stress constant, K, was determined for the diffraction line of (211)plane by using Cr-K$\alpha$ radiation. K was -340.87 MPa/deg. Fatigue crack propagation tests of SS41 steel were conducted under stress ratios of 0.1, 0.3 and 0.5. The half-value breadth of X-ray diffraction profile was measured at and beneath the fracture surface. The half-value breadth, B, on the fracture surface was found to increase with increasing $K_max$. The value of B was influenced by stress ratio in SS41 steel. The half-value breadth took the maximum value at the borden of reversed plastic zone, while it approached to the initial (pre-fatigue) value near the boundary of monotonic plastic zone. The maximum depth of the plasticzone was evaluated on the basis of the half-value breadth distribution. The depth $\omega$$_y$ is related to $K_max$by the following equation : $\omega$$_y$ = $\alpha$($K_max$/$\sigma$$_y$$)^2$ where .sigma.$\sigma$$_y$ is the yield strength obtength obtained in tension test .alpha.is 0.136 for SS41 steel.

  • PDF