• 제목/요약/키워드: guide impeller

검색결과 47건 처리시간 0.022초

상용 CFD코드를 이용한 입형 다단 원심펌프 성능해석 (Performance Analysis of the Vertical Multi-stage Centrifugal Pump using Commercial CFD Code)

  • 모장오;강신정;송근택;남청도;이영호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 추계 학술대회논문집
    • /
    • pp.150-155
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pump including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is not only to confirm how much the effect of three kinds of blade inlet breadth (11mm, 11.5mm, 12mm) of impeller has influence on the performance of vertical multi-stage pump but also to make clear the cause about performance difference at the exit side of impeller and guide vane. The vertical multi-stage pump consisit of the impeller, guide, vane and cylinder. The grid of numerical analysis used to the vertical multi-stage pump is 18,000, 45,000, and 100000 cells in case of the impeller, guide vane, cylinder and total grid is 730,000 cells. The characteristics such as total pressure coefficient, total head, shaft horse power, power efficiency at the exit side of impeller and guide vane, discharge coefficient are represented according to flow rage changing.

  • PDF

혼류임펠러를 갖는 관류형팬의 성능특성 (Performance Characteristics of In-Line Duct Fan Having Mixed Flow Impellers)

  • 박진욱;이철형;박완순;허종철
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.79-85
    • /
    • 2007
  • The performance of in-line duct fan depends on the design parameters of impeller and guide vane such as sweep back angle of impeller hub, guide vane angle etc. In this study four kinds of impellers having different sweep back angles, $0^{\circ}$, $17.5^{\circ}$, $35^{\circ}$, $52.5^{\circ}$ with 8 guide vanes, and different guide vane angles, $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ were selected and their performance measured to investigate the effects of design parameters. The results show that both sweep back angle of impeller hub and the guide vane angle have large effect on the efficiency. Especially, it was found that the mixed flow impellers having sweep back angle between $17.5^{\circ}$ and $35^{\circ}$ gave good performances for in-line duct fan.

CFD에 의한 입형 다단 원심펌프 유동특성에 관한 연구 (A Study on Flow Characteristics of Vertical Multi-stage Centrifugal Pump by CFD)

  • 모장오;남구만;김유택;이영호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.402-407
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pimp including impeller with 6 blades and guide vane with 11 blades and is performed by changing flow rate from 10 to $26\;m^3/h$ at the constant 3500rpm. The purpose of this 3-D numerical simulation is to confirm how much the effect of blade inlet angle of guide vane has an influence on the performance of vertical multi-stage centrifugal pimp. these results performed by $20^{\circ},\;30^{\circ}$ inlet angle of guide vane are compared with grundfos performance data. The vertical multi-stage pump consist of the impeller, guide vane, and cylinder. The characteristics such as total pressure coefficient total heat shaft horse power, power efficiency, discharge coefficient are represented according to flow rate changing.

  • PDF

관류형팬의 설계변수 특성에 관한 연구 (A Study on Characteristics of Design Parameters for In-line Duct Fan)

  • 박진욱;허종철;이철형;박완순
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.373-377
    • /
    • 2005
  • The Performance of in-line duct fan depends on the design parameters of impeller and guide vane. such as sweep back angle of impeller, the number of blades, outlet blade angle, guide vane angle etc. In this experimental study total four kinds of impellers having different sweep back angles, $90^{\circ},\;72.5^{\circ},\;55^{\circ},\;37.5^{\circ}$ with 8 guide vanes, different the number of blades, 6ea, 8ea, 10ea, 12ea, different kinds of outlet blade angles, $30^{\circ},\;45^{\circ}.\;60^{\circ}$ and different kinds of guide vane angles, $15^{\circ},\;30^{\circ},\;45^{\circ}$ were selected and their performance measured to investigate the effects of them. The results were non-dimensionalized to compare their performance.

  • PDF

입형 다단 원심펌프 유동특성에 관한 수치해석 (A Numerical Analysis on Flow Characteristics of Vertical Multi-stage Centrifugal Pump)

  • 모장오;강신정;송근택;김성동;이영호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.589-592
    • /
    • 2002
  • A commercial CFD code is applied to analyze the 3-D viscous flow field within vertical multi-stage centrifugal pump including impeller of centrifugal pump with 6 blades and guide vain with 11 blades. The numerical analysis of vertical multi-stage centrifugal pump is performed by changing flow rate from $8\;to\;26\;m^{3}/h$ at the constant 3500rpm. The characteristics such as total pressure coefficient, total head, water horse power, power efficiency are represented according to flow rate changing. In the future, we will need to perform flow calculation of vertical multi-stage centrifugal pump by considering meridional shape of impeller.

  • PDF

고해상도 CCD 카메라를 이용한 디퓨져펌프 내부 유동특성에 대한 PIV 계측 (A PIV Measurement on Flow Characteristics inner Diffuser Pump Using High Resolution CCD Camera)

  • 김성윤;김범석;김정환;김유택;이영호
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2002년도 춘계학술대회논문집
    • /
    • pp.161-166
    • /
    • 2002
  • The resent experimental study is focused on the application of multi-point simultaneous measurement by PIV Particle Image Velocimetry) to guide vane region within diffuser pump. Various different kinds of rotational veto ity and changing clearance between Guide Vane and Impeller were selected as experimental condition. Optimized ross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coeffi cients. Fine optical setup concerned with PW performance is arranged for the accurate PW measurement of high peed complex flow. Variable flow pattern are represented quantitatively at the stator region.

  • PDF

다단 원심펌프 임펠러의 개량 수력설계 (Impeller Redesign of Multi-stage Centrifugal Pumps)

  • 오종식;김동수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2001년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.177-184
    • /
    • 2001
  • For two kinds of the multi-stage centrifugal pump with diffuser vanes and return channel vanes the meanline performance prediction is applied to get information of hydraulic performance at each internal flow station, because only flange-to-flange test curves are available. As a first step of redesign fur higher efficiency, the impeller geometry is numerically investigated in the present study. Quasi-3D inviscid loading distributions are obtained, for the two impellers, using the state-of-the-art method of impeller 3D design, which provides a guide to optimal redesign. Full 3D turbulent flow fields are thereafter analyzed, using the specialized CFD code, to confirm the redesign results. The inherent limitation of the traditional graphic method of impeller design, which most of domestic pump manufacturers are now employing, is found.

  • PDF

고마력 터보 블로어의 최적 깃배치각에 관한 수치 예측 (NUMERICAL PREDICTION OF THE OPTIMAL STAGGER ANGLES FOR A HIGH-POWER TURBO BLOWER)

  • 박태규;정희택;박준영;성병일
    • 한국전산유체공학회지
    • /
    • 제16권3호
    • /
    • pp.75-81
    • /
    • 2011
  • The turbo blowers having large power capacity are generally composed of the variable inlet guide vane, the impeller and the variable diffuser. In the present study, the effect of the stagger angles on the aerodynamic performances has been investigated by CFD methods. The design specifications of the reference model having 400kW power were given as 7.43kg/s of mass flow rate, 1.66 of pressure ratio with 12000rpm of impeller rotating speed. As the first simulation parameter, the diffuser vane angle was varied in the range of ${\pm}$20 degree from the initial-design point. The inlet guide vane angles, as the second one, was changed in the range of ${\pm}$40 degree from the initial-design point. The commercial Navier-Stokes solver, ANSYS-CFX, was applied to solve the three-dimensional unsteady flow fields inside the turbo blower. Through the numerical results, the desirable setting angles were proposed to fit the best performance to the variation of the operating conditions.

Optimum Design of a Cross Flow Fan

  • Kim Dong-Hoon;Park Hyung-Koo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 The Fifth Asian Computational Fluid Dynamics Conference
    • /
    • pp.260-262
    • /
    • 2003
  • Cross-flow fans are widely used in various applications, due to their large capacity of mass flow and size compactness. The flow field of the cross-flow fan is, however, complex and has many design parameters. Thus, the general design guide has not been sufficiently established yet and the design strategies of cross-flow fans have been based on experiments. In the present study, the performance and their two-dimensional flow characteristics are numerically analyzed by using the STAR-CD(commercial computational fluid dynamics code). The simulation is done by varying the several design parameters such as the impeller blade shapes and the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally some helpful guides for the optimum design of cross-flow fans are proposed.

  • PDF

횡류팬의 최적설계방안 (Optimum Design of a Cross Flow Fan)

  • 김동훈;박형구
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.176-181
    • /
    • 2003
  • The cross-flow fans are widely used in various applications, due to their large capacity of mass flow and the size compactness. The flow fields of the cross-flow fan is, however, complex and it has many design parameters. Thus the general design guide has not sufficiently established yet, and the design strategies of cross-flow fans have been based on experiments. In the present study, the cross-flow fan performance and its two-dimensional flow characteristics are numerically analyzed by using the STAR-CD. The simulation is done by varying the several design parameters such as impeller blade shapes, the gap between the stabilizer and impeller. The computational results are compared with the experimental data at the fan outlet region. Finally some helpful guides for the optimum design of the cross-flow fan are proposed.

  • PDF