• Title/Summary/Keyword: groundwater velocity

Search Result 140, Processing Time 0.024 seconds

A Study on the Infiltration Porperties of Cement Grout Material (시멘트계 주입재의 침투특성에 관한 실험적 연구)

  • 천병식;신동훈;이종욱;김진춘;이준우;안익균;이승범
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.297-304
    • /
    • 2002
  • This study is about penetrability of Micro Cement(MC) used for ground improvement. In this study, the characteristics of chemical grouting such as solidification, penetrability were analyzed experimentally by changing permeability of ground, grain size and relative density of grout material. For evaluating applicability of grout material, solidification test and penetrability test were performed. From the results of the tests, effective solidification ratio and penetrability ratio of MC was each 75%, 86% to be excellent when ground permeability was in the range of 10$^{-2}$ and 10$^{-4}$ cm/sec. Otherwise, those of Ordinary Portland Cement(OPC) were both lower than 50% to be poor. When penetrability of grout material is needed for improvement of dam foundation and soft ground, application of MC Is much superior to that of the other materials. The results of the grouting tests in the water flowing ground show that solidification effect of long gel-time grout material is excellent as injection pressure increases when groundwater velocity is relatively low. But when groundwater velocity is relatively high, solidification effect of long gel-time grout material is very poor because most grout materials are outflowed. Therefore, as groundwater velocity is high, effective solidification ratio of long gel-time grout material is better than that of short gel-time grout material, also penetration distance of long gel-time grout material is longer than that of short gel-time grout material.

  • PDF

Significant Parameters for Assessing Soil Contaminant-Leaching to Groundwater and Determining Soil Sample Size in Field Survey

  • Jeong, Seung-Woo;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • For a given soil-contaminated site, a level of soil contamination is characterized and decisions on risk may be made from the risk assessment. The study evaluated critical design factors for the determination of sample size in the sampling design plan and the assessment of soil contaminant- leaching to groundwater. Two variables, the minimum relative detectable difference (T) and coefficient of variation (CV) were evaluated for the sample size determination. The minimum number of samples can be appropriately determined by CV under a T value greater than or equal to 0.2. Soil-contaminant leaching to groundwater was evaluated by using the Soil Screening Level equation of U.S. Environmental Protection Agency and the Risk Based Screening Level equation of American Society for Testing and Materials, with the same input parameters. The groundwater concentrations estimated from soil contaminant concentrations were significantly affected by the Darcy velocity of groundwater and the organic content of soil.

현장 규모 biobarrier의 수리학적 특성과 기초 설계

  • 최영화;오재일;왕수균;배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.426-430
    • /
    • 2003
  • Subsurface biobarrier technology has potential applications to contain contaminated groundwater and/or to degrade toxic pollutants in groundwater. Effective biobarrier formation is need to assess of hydrogeologic characteristics and to conduct practical operation strategies and design based on this prior to design biobarrier. Thus, in this study, we examined hydrogeologic characteristics in biobarrier construction site. Hydraulic conductivities which calculated from slug test data have shown difference with each well as 1.20$\times$10$^{-3}$ -6.00$\times$10$^{-5}$ cm/sec. Tracer test is a method in which concentration of tracer solution during withdrawal in each well by vacuum extraction system is measured with time. Tracer solution was continuously injected by constant head tank. Measured tracer concentration versus time data were fitted to analytical solution of convection dispersion equation (CDE). The fitting data of CDE to the measured data at each extraction well yielded were 0.61cm/min(pore velocity), 5.38$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.47 1/min and 1.75cm/min(pore velocity), 36.34$\textrm{cm}^2$/min(dispersion coefficient) for discharge rate of 0.93 1/min. As a result, we acquired fundamental parameters which need to design biobarrier and operation strategies.

  • PDF

Applicability of Relative Effective Porosity Model to Tracer Tests

  • Hwang, Hyeon-Tae;Lee, Gang-Geun;Suleiman, A.A.
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.341-345
    • /
    • 2004
  • An attempt has been made in this study to evaluate an applicability of Relative Effective Porosity Model (REPM) as a method for estimating saturated hydraulic conductivity (K$_{s}$) for homogeneous coarse, medium, and fine sands. The saturated hydraulic conductivities obtained from REPM are converted into average linear velocities using Darcy's Law and compared with the results from experimental tracer tests for homogeneous coarse, medium, and fine sand layer. Two types of tracer tests analyses, analytical solution using CXTFIT and moment methods, are performed to obtain reasonable linear velocity range for each layer. For the coarse and medium sands, the converted average linear velocity from REPM is in the velocity range obtained from tracer tests. However, small difference between the results from REPM and tracer tests is found for the fine sands. These results show that REPM gives reasonable estimates of saturated hydraulic conductivity.y.

  • PDF

Suitable Use of Capillary Number for Analysis of NAPL Removal from Porous Media

  • Jeong, Seung-Woo,
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.09a
    • /
    • pp.25-28
    • /
    • 2004
  • The capillary number is used to represent the mobilization potential of organic phase trapped within porous media. The capillary number has been defined by three different forms, according to types of flow velocity and viscosity used in the definition of capillary number. This study evaluated the suitability of the capillary number definitions for representing TCE mobilization by constructing capillary number-TCE saturation relationships. The results implied that the capillary number should be correctly employed, according to interest of scale and fluid flow behavior. This study suggests that the pore-scale capillary number may be used only for investigating the organic-phase mobilization at the pore scale because it is defined by the pore-velocity and the dynamic viscosity. The Newtonian-fluid capillary number using Darcy velocity and the dynamic viscosity may be suitable to quantify flood systems representing Newtonian fluid behavior. For viscous-force modified flood systems such as surfactant-foam floods, the apparent capillary number definition employing macroscopic properties (permeability and potential gradient) may be used to appropriately represent the desaturation of organic-phases from porous media.

  • PDF

The Characteristics of Hydrogeological Parameters of Unconsolidated Sediments in the Nakdong River Delta of Busan City, Korea

  • Khakimov, Elyorbek;Chung, Sang Yong;Senapathi, Venkatramanan;Elzain, Hussam Eldin;Son, JooHyeong
    • Journal of Soil and Groundwater Environment
    • /
    • v.22 no.3
    • /
    • pp.27-41
    • /
    • 2017
  • This study dealt with the characteristics and the interrelations of hydrogeological parameters such as hydraulic conductivity, dispersivity and effective porosity of unconsolidated sediments for providing the basic data necessary for the planning of the management and preservation of groundwater quality in the Nakdong River Delta of Busan City, Korea. Groundwater quality in this area has been deteriorated due to seawater intrusion, agricultural fertilizer and pesticide, industrial wastewater, and contaminated river water. The physical properties (grain size distribution, sediment type, sorting) and aquifer parameters (hydraulic conductivity, effective porosity, longitudinal dispersivity) were determined from grain size analysis, laboratory permeability test and column tracer test. Among 36 samples, there were 18 Sand (S), 7 Gravelly Sand (gS), 5 Silty Sand (zS), 5 Muddy Sand (mS), and 1 Sandy Silt (sZ). Hydraulic conductivity was determined through a falling head test, and ranged from $9.2{\times}10^{-5}$ to $2.9{\times}10^{-2}cm/sec$ (0.08 to 25.6 m/day). From breakthrough curves, dispersivity was calculated to be 0.35~3.92 cm. Also, effective porosity and average linear velocity were obtained through the column tracer test, and their values were 0.04~0.46 and 1.06E-04~6.49E-02 cm/sec, respectively. Statistical methods were used to understand the interrelations among aquifer parameters of hydraulic conductivity, effective porosity and dispersivity. The relation between dispersivity and hydraulic conductivity or effective porosity considered the sample length, because dispersivity was affected by experimental scale. The relations between dispersivity and hydraulic conductivity or effective porosity were all in inverse proportion for all long and short samples. The reason was because dispersivity was in inverse proportion to the groundwater velocity in case of steady hydrodynamic dispersion coefficient, and groundwater velocity was in proportion to the hydraulic conductivity or effective porosity. This study also elucidated that longitudinal dispersivity was dependent on the scale of column tracer test, and all hydrogeological parameters were low to high values due to the sand quantity of sediments. It is expected that the hydrogeological parameter data of sediments will be very useful for the planning of groundwater management and preservation in the Nakdong River Delta of Busan City, Korea.

Feasibility Evaluation for Remediation of Groundwater Contaminated with Heavy Metal using Calcium Polysulfide in Homogeneous media (균질한 매질 내 Calcium polysulfide 주입에 따른 고농도 중금속 오염 지하수 정화 타당성 검토)

  • Hyeon Woo Go;Jin Chul Joo;Kyoungphile Nam;Hee Sun Moon;Sung Hee Yoon;Dong Hwi Lee;So Ye Jang
    • Journal of Soil and Groundwater Environment
    • /
    • v.28 no.1
    • /
    • pp.1-14
    • /
    • 2023
  • In this study, column tests using relatively uniform Jumunjin sand media were conducted to evaluate the feasibility of calcium polysulfide (CaSx, CPS) in removing high concentration of Zn2+ in groundwater. The injected CPS solution reacted rapidly with Zn2+ in artificial groundwater and effectively reduced Zn2+ by more than 99% through metal sulfide precipitation. Since the density (d = 1.27 g/cm3 ) of CPS solution was greater than that of water, CPS solution settled down rapidly while capturing Zn2+ and formed stable CPS layer similar to dense nonaqueous phase liquid. Mass balance analysis on Zn2+ in CPS solution suggested that CPS solution effectively reacted with Zn2+ to form metal sulfide precipitates except for high groundwater seepage velocity of 400 cm/d. With greater groundwater seepage velocity, injected CPS did not completely dissolve at the CPS-water interface, but a partially-misible CPS layer continuously moved and reacted with Zn2++ in the direction of groundwater flow. Since hydraulic conductivity (Kh) decreased slightly due to the generated metal precipitates in the inter-pores of media, injection of CPS solution should be optimized to prevent clogging. As evidenced by both XRF and SEM/EDS results, ZnS precipitates were clearly observed through the reaction between the CPS solution and Zn2+. Further study is warranted to evaluate the feasibility of CPS to remove high-concentration heavy metalcontaminated groundwater in complex and heterogeneous media.

Simulation of aquifer temperature variation in a groundwater source heat pump system with the effect of groundwater flow (지하수 유동 영향에 따른 지하수 이용 열펌프 시스템의 대수층 온도 변화 예측 모델링)

  • Shim, Byoung-Ohan;Song, Yoon-Ho
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.701-704
    • /
    • 2005
  • Aquifer Thermal Energy Storage (ATES) can be a cost-effective and renewable geothermal energy source, depending on site-specific and thermohydraulic conditions. To design an effective ATES system having influenced by groundwater movement, understanding of thermo hydraulic processes is necessary. The heat transfer phenomena for an aquifer heat storage are simulated using FEFLOW with the scenario of heat pump operation with pumping and waste water reinjection in a two layered confined aquifer model. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at the both wells during 365 days. The average groundwater velocities are determined with two hydraulic gradient sets according to boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions of three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.00 1 are shaped circular, and the center is moved less than 5m to the groundwater flow direction in 365 days simulation period. However at the hydraulic gradient of 0.01, the contour center of the temperature are moved to the end of boundary at each slice and the largest movement is at bottom slice. By the analysis of thermal interference data between two wells the efficiency of the heat pump system model is validated, and the variation of heads is monitored at injection, pumping and no operation mode.

  • PDF

Application of a Pilot-Scale Electrodialysis System for Groundwater Polluted with Arsenic and Manganese (파일롯 규모 전기투석 막여과 시스템을 이용한 비소와 망간오염 지하수 처리)

  • Choi, Su Young;Kwon, Min Wook;Park, Ki Young;Cha, Ho Young;Kim, Hee Jun;Kweon, Ji Hyang
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.3
    • /
    • pp.334-340
    • /
    • 2017
  • A pilot-scale electrodialysis system was designed and constructed to treat groundwater polluted with arsenic and manganese. Synthetic groundwater, in which some amount of arsenic and manganese was added to make 500 mg/L of Mn and $50{\mu}g/L$ of As, was used as a feed for the ED system. The limiting current density, linear water velocity, applied voltage, and membrane surface area were investigated to obtain efficient and economic operation of the ED system. The linear water velocity was increased 0.74 cm/s to 11 cm/s based on evaluation of limiting current density. The water quality of diluate for 85 minutes of operation was satisfied with water quality criteria for drinking water using the ED system with 14 pairs of ion exchange membranes. The increased membrane pairs to 21 and 42 pairs were very effective to reduce conductivities of the diluate. The operation cost of the ED system was assessed using specific energy consumption, which was $1.065{\sim}1.2kWh/m^3$. Considering low salt concentrations of the groundwater, improvement of the ED system are required to increase current utilization and to apply low voltage while the ED system was applicable to produce drinking water.

Effect of Groundwater Flow on Ice-wall Integrity (얼음벽 형성에 대한 지하수 흐름의 영향)

  • Shin, Hosung;Kim, Jinwook;Lee, Jangguen
    • Journal of the Korean Geotechnical Society
    • /
    • v.34 no.11
    • /
    • pp.43-55
    • /
    • 2018
  • AGF (Artificial Ground Freezing) method is a temporary ground improvement method which can apply to all types of soil with the purpose of high stiffness and low hydraulic conductivity. However, the groundwater flow and the heterogeneity of the ground increase the uncertainty of the ice-column formation which hinders the reliability of this method. The effects of groundwater flow and layered heterogeneity on ice-wall integrity by AGF method were analyzed using finite element analysis program for a coupled thermo-hydro phenomena in the freezing ground. Groundwater flow changes circular ice-column into elliptical shapes and increases the time required for the formation of ice walls. The previous theoretical formula overestimated the completion time of the ice wall and the critical groundwater velocity by neglecting the thermal interaction between adjacent ice-columns. Numerical results presented the corrected formula and verified the proposed equation for the dimensionless ice-wall completion time. In the layered heterogeneous ground, the thickness of the layer with higher hydraulic conductivity and its relative magnitude were found to be important factors in the ice-wall completion time and critical velocity.