• 제목/요약/키워드: groundwater level variation

검색결과 124건 처리시간 0.022초

댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구 (A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body)

  • 오석훈;김중열;박한규;김형수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

부력저항 영구앵커의 장기거동 특성에 관한 연구 (A Study on the Long-Term Behavior Characteristics of Buoyancy-Resistant Permanent Anchor)

  • 허병주;김찬기;정용건;천병식
    • 한국지반환경공학회 논문집
    • /
    • 제11권12호
    • /
    • pp.27-35
    • /
    • 2010
  • 지하공간에 설치되는 구조물 중 지하수위 아래에 위치하는 부분은 상향으로 정수압인 부력이 작용하게 된다. 최근 큰 규모의 중요구조물 즉, 부력이 크게 발생하는 구조물은 공사비가 고가이나 안전율을 확실하게 증가시키는 방법인 부력저항 영구앵커를 많이 적용하고 있는 실정이다. 그러나, 부력저항 영구앵커의 저항 메커니즘 규명은 미흡한 실정이다. 특히, 시공 후 앵커의 장기거동에 대한 규명은 계측 관리의 어려움으로 이루어지지 않고 있는 것이 현실이다. 본 연구에서는 부력 저항 영구앵커의 설계 시 합리적인 구조물 거동 평가를 위하여 앵커두부에 하중계를 설치하여 앵커축력을 자동화계측 및 수동계측을 통해 시공초기부터 10년간 계측 분석하였으며, 이를 토대로 건물의 자중증가에 따른 앵커의 시공단계별 거동과 시간 경과에 따른 앵커의 장기거동(시공 후 10년 이내의 거동)을 분석하였다.

A Study on Unsaturated Zone Characterization and Feasibility of Soil Vapor Extraction at a DNAPL-contaminated Site in Korea

  • Lee, Man Na Mi;Yeo, In Wook
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제18권6호
    • /
    • pp.48-55
    • /
    • 2013
  • This study aimed at characterizing unsaturated zone at the source zone area contaminated by DNAPL and investigating feasibility of soil vapor extraction (SVE). Five boreholes with three multi-level screens at the depth of 3.0~4.5 m, 5.5~7.0 m, and 8.0~12.0 m were installed at the source zone. Pneumatic tests were performed to determine the permeability of porous medium. Permeability was estimated to be 81.6 to 203.7 darcy, depending on the applied solutions, which was contradicted by grain size analysis of cored soil samples leading to 3.51 darcy. This is due to air flow through gravel pack during the early stage of pneumatic test. Pressure-drawdown curve in the late stage also well showed the leaky aquifer type, indicating air leakage to the ground. Air flow tests were also carried out to investigate air flow connectivity between multi-level wells, indicating that the horizontal air flow was well developed between the lower screens of the wells, not between the upper and middle screens due to the leakage to the surface. For the SVE test, there was no noticeable variation in TCE vapor concentration between three different test runs: 1. 8 hours daily for 5 days, 2. 24 hours together with air blowing at another well (BH1), 3. five consecutive days. Even for five-day consecutive test, total amount of removed TCE was estimated only to be as low as 46.5 g.

Modeling the effects of excess water on soybean growth in converted paddy field in Japan 1. Predicting groundwater level and soil moisture condition - The case of Biwa lake reclamation area

  • Kato, Chihiro;Nakano, Satoshi;Endo, Akira;Sasaki, Choichi;Shiraiwa, Tatsuhiko
    • 한국작물학회:학술대회논문집
    • /
    • 한국작물학회 2017년도 9th Asian Crop Science Association conference
    • /
    • pp.315-315
    • /
    • 2017
  • In Japan, more than 80 % of soybean growing area is converted fields and excess water is one of the major problems in soybean production. For example, recent study (Yoshifuji et al., 2016) suggested that in the fields of shallow groundwater level (GWL) (< 1m depth), rising GWL even in a short period (e.g. 1 day) causes inhibition of soybean growth. Thus it becomes more and more important to predict GWL and soil moisture in detail. In addition to conventional surface drainage and underdrain, FOEAS (Farm Oriented Enhancing Aquatic System), which is expected to control GWL in fields adequately, has been developed recently. In this study we attempted to predict GWL and soil moisture condition at the converted field with FOEAS in Biwa lake reclamation area, Shiga prefecture, near the center of the main island of Japan. Two dimensional HYDRUS model (Simuinek et al., 1999) based on common Richards' equation, was used for the calculation of soil water movement. The calculation domain was considered to be 10 and 5 meter in horizontal and vertical direction, respectively, with two layers, i.e. 20cm-thick of plowed layer and underlying subsoil layer. The center of main underdrain (10 cm in diameter) was assumed to be 5 meter from the both ends of the domain and 10-60cm depth from the surface in accordance with the field experiment. The hydraulic parameters of the soil was estimated with the digital soil map in "Soil information web viewer" and Agricultural soil-profile physical properties database, Japan (SolphyJ) (Kato and Nishimura, 2016). Hourly rainfall depth and daily potential evapo-transpiration rate data were given as the upper boundary condition (B.C.). For the bottom B.C., constant upward flux, which meant the inflow flux to the field from outside, was given. Seepage face condition was employed for the surrounding of the underdrain. Initial condition was employed as GWL=60cm. Then we compared the simulated and observed results of volumetric water content at depth of 15cm and GWL. While the model described the variation of GWL well, it tended to overestimate the soil moisture through the growing period. Judging from the field condition, and observed data of soil moisture and GWL, consideration of soil structure (e.g. cracks and clods) in determination of soil hydraulic parameters at the plowed layer may improve the simulation results of soil moisture.

  • PDF

산악지역의 터널건설에 의한 지하수위 변동분석 (Analysis of Groundwater-Level Variation Caused by Tunnel Construction at a Mountain Area)

  • 강동환;정상용;심병완;김병우;정상원
    • 대한지질공학회:학술대회논문집
    • /
    • 대한지질공학회 2002년도 정기총회 및 학술발표회
    • /
    • pp.137-146
    • /
    • 2002
  • 수락산 터널구간 기반암의 평균투수계수는 $2.64{\times}10^{-6}cm/sec$, 평균RQD는 78%, 평균공극율 은 0.51% 이다. 지하수위와 표고간의 상관성분석을 이용하여 수락산 정상부에서 지하수위를 추정한 결과, 터널구간의 전체 평균수리경사는 0.267로서 산출되었다. 수리분석에 의한 수락산 터널구간에서의 지하수 유출량은 약 $66,378~121,574\textrm{m}^3/yr$, 함양량은 $863,500\textrm{m}^3/yr$로 산정 되었다. 3차원 지하수유동모델링 소프트웨어 MODFLOW를 이용하여 터널건설에 의한 지하수위 변동을 분석한 결과, 1년 후에는 터널 중심부에서의 지하수위 강하가 각각 40~45m로 나타났으며 터널구간의 지하수위는 3년 후에, 그리고 모델 영역 전체 지하수위는 4,5년 후에 완전하게 정류상태로 회복되었다.

  • PDF

부산광역시 사상공단지역의 지하수 및 토양 위해성 평가 (Risk Assessment of Groundwater and Soil in Sasang Industrial Area in Busan Metropolitan City)

  • 전항탁;함세영;정재열;류상민;장성;이정환;이수형
    • 지질공학
    • /
    • 제19권3호
    • /
    • pp.295-306
    • /
    • 2009
  • 본 연구는 지하수, 토양, 대기의 노출경로에 따라서 부산광역시 사상공단의 지하수와 토양이 인체와 환경에 미치는 영향을 평가하였다. 토양과 대기의 노출경로에 따른 발암 위해는 나타나지 않았으나, 지하수에서는 TCE와 PCE의 발암 위해성이 각각의 기준 한계값인 1.0E-6과 1.0E-5에 대해서 각각 6.7E-6과 1.0E-5로 나타나 발암 위해가 있는 것으로 판단되었다. 대기에서는 비발암성 위해가 나타나지 않았다. 토양의 위해계수와 위해지수는 각각 3.4E-5와 5E-5로서 기준 한계값(1.0) 보다 낮게 나타났으나, 지하수의 위해계수와 위해지수는 각각 0.7 (위해성이 없음)과 1.4(위해성이 있음)로 나타났다. TCE의 최소성분감소비(CRF)는 2.5로서 TCE의 정화작업이 요구된다. 18개의 노출인자에 대한 민감도 분석 결과, 8개의 노출 인자(비 발암 물질에 대한 평균 수명, 발암 물질에 대한 평균 수명, 체중, 노출기간, 노출빈도, 피부노출빈도, 토양 섭취율, 물 섭취율)의 변화에 따라서 위해도가 변화하는 것으로 나타났다.

지표수-지하수 통합모형을 이용한 무심천 유역의 수문과정 해석 (Analysis of Hydrological Processes for Musim River Basin by Using Integrated Surface water and Groundwater Model)

  • 김남원;정일문;이정우;원유승
    • 한국수자원학회논문집
    • /
    • 제40권5호
    • /
    • pp.419-430
    • /
    • 2007
  • 지표수와 지하수의 통합모델링은 지속가능한 수자원과 수질개선에 대한 점증하는 요구를 만족시키기 위해 점차 중요성을 더해가고 있다. 본 연구에서는 준분포형 유역유출모형인 SWAT과 완전분포형 지하수 모형인 MODFLOW의 통합모형을 무심천 유역에 작용하여 유역단위의 수문과정을 재생하였다. 모의결과 2001-2004년의 관측수문곡선과 모의유량수문곡선간의 적합이 잘 나타나는 한편 계산된 지하수위 분포와 관측지하수위와의 보정결과도 양호하게 나타났다. 통합모형은 서로 다른 기간의 강수평균이 하천유출, 침루, 함양, 지하수 유출의 동적과정에 미치는 영향을 평가하는데도 활용되었다. 나아가, 윌별강수와 각 수문성문간의 관계를 살펴보고 함양량의 시공간적 변동성을 분석하기 위한 종합적인 모의를 수행한 결과, 수문성분 상호간에 높은 상관성을 보이며 소유역경사, 토지이용, 토양종류 같은 유역특성의 비균질성이 함양량의 공간변화에 주요 원인인 것으로 확인됐다. 통합모형은 시공간적으로 변모하는 유역단위의 지표수와 지표하 수문과정을 전반적으로 잘 표현하는 것으로 나타났다.

지진 전조인자로서 지하수내 라돈 및 화학성분의 상관성 연구 (Relationship of Radon-222 and Chemical Composition of Groundwater as a Precursor of Earthquake)

  • 정찬호;박준식;이용천;이유진;양재하;김영석;오송민
    • 지질공학
    • /
    • 제28권2호
    • /
    • pp.313-324
    • /
    • 2018
  • 한반도 지진에 대한 전조인자 연구를 위해 대전, 청원지역 지하수 관측정에서 심도별(-60 m, -100 m)로 화학성분과 라돈, 수위변화를 주기적으로 측정하였다. 관측정 특정심도 지하수의 pH와 전기전도도 값이 포항지진 발생에 따라 큰 폭으로 증가하는 등 비교적 뚜렷한 상관성을 보였다. 주요화학 성분 중에는 대전관측정에서는 ${HCO_3}^-$, $Cl^-$의 농도가 지진과의 연관성 있는 변동을 보이며, 청원지역 관측정에서는 $Mg^{2+}$, $Cl^-$, ${NO_3}^-$의 농도가 변화를 보였다. 그러나 지하수의 주요 화학성분의 변화는 지진발생과의 상관성이 명확하지는 않다. 대전관측정 지하수내 라돈 함량은 지진 발생 전 최저 162 Bq/L에서 지진발생 직후 573 Bq/L로 크게 증가하는 경향을 보여 지진과의 뚜렷한 상관성을 보여주었다. 지하수위의 경우에는 지진발생과의 상관성은 확인되지 않고 갈수기로 인한 지속적인 하강의 양상을 보여주었다. 그러나 포항 진앙지 10 km 이내 국가 지하수 관측정에서는 지진발생 직전 뚜렷한 지하수위의 하강 현상을 보여주었다. 결론적으로 포항지진 진앙지와 약 180 km 이상 떨어진 지역이지만 대전 관측정에서 라돈가스는 지진과 가장 뚜렷한 상관성을 보여 지진전조인자로서의 신뢰성할 수 있는 후보로서 가능성을 확인하였다. pH, 전기전도도, ${HCO_3}^-$, $Cl^-$성분은 지진과 일정 부분 상관성을 보여주었지만 보다 더 장기적인 모니터링을 통하여 지진전조로서 가능성을 확인할 수 있을 것으로 보인다.

흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석 (Analysis of temperature monitoring data for leakage detection of earth dam)

  • 오석훈;서백수
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

수리영역 개념을 적용한 단열암반의 지하수유동체계 해석 (Analysis of a Groundwater Flow System in Fractured Rock Mass Using the Concept of Hydraulic Compartment)

  • 조성일;김천수;배대석;김경수;송무영
    • 지질공학
    • /
    • 제16권1호
    • /
    • pp.69-83
    • /
    • 2006
  • 본 연구는 지하유류저장공동 굴착 시 조사된 단열체계 및 수리 인자를 토대로 투수성구조영역과 수리암반영역으로 세분화하여 연구지역의 불규칙하고 복잡한 지하수유동체계를 해석해 보고자 하였다. 지하공동 내에서 확인된 단열분포특성과 지하공동굴착과 동시에 지표관측공 28개를 통해 측정된 지하수위 및 수평수벽공 95개와 수직수벽공 63개에 의해 일별로 계측된 압력 및 주입량을 통해 연구지역은 지하수의 방벽역할을 하는 3개의 투수성구조영역과 4개의 수리암반영역으로 구분이 가능하였다. 공동심도에 발달된 투수성 구조는 국지적 큰 규모 단열대인 NE-1과 2개의 국지규모 단열대로 구성되고 있으나, 수리암반영역은 국지규모 단열대에 의하여 4개 영역으로 구분된다. FZ-2 구조대와 인접한 수리암반영역 Domain-A와 B는 수평수벽공의 초기압이 최대 약 $15kg/cm^2$까지 높으며, 지하공동 굴착 시 상 하부의 지하수위변화의 차이가 $10\sim40m$로 상 하부의 수리적 연결성이 양호한 것으로 평가된다. 반면, FZ-1 구조대와 인접한 Domain-C와 D는 이중수위측정 시설 설치시 상부와 하부의 지하수위차는 최대 약 120 m로 매우 크게 나타났으며, 상부 지하수는 공동굴착 시 수위 가 크게 변화하지 않았다. Domain C, D의 하부암반의 수리 전도도$(7.2X10^{-10}m/sec)$는 상대적으로 낮은 지하수 함양량의 원인을 제공하고 있으며, 연속체개념 의 지하수유동모델링을 통해 계산된 4개 영역의 함양량은 연구지역의 20년간 평균 강수량(1,356 mm/year)의 2%로 계산되었다.