A Proposal of Baseflow using Discharge Measurement Method in the Streams of Island (도서지역 하천의 기저유출량 산정을 위한 유량측정방법 제안)

  • Lee, Jun-Ho;Yang, Sung-Kee;Jung, Woo-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.561-569
    • /
    • 2014
  • The water resources system of Jeju-do Island entirely depends on groundwater. This study is making a precision observation of baseflow, surface water, water shortage that might be vulnerable to climate change and drought in future. The field observation of baseflow discharges in Akgeuncheon stream has regularly been made with ADCP and ADC and Flowmate every two weeks for twenty-two (22) months (July 8, 2011 to April 27, 2013). This paper represent the results of calculating discharge of a number of hydraulic structures (broad-crested weirs) with comparing and has been calculated more accurate discharges with suitability of different observation methods. The average discharge has been observed 0.851 $m^3/s$, whereas the average ADC and Flowmate is 0.709 $m^3/s$. Meanwhile, stream discharge has been calculated 0.709 $m^3/s$ through the broad-crested weir equation. The discharge has calculated with the weir equation greatly changed according to even a small change in the water level. However, it showed a similar trend to one of the observed discharge. Although, in past there were generating errors caused by observers' strides, vertical and horizontal flow velocity distribution when the average flow velocity had been measured, non-prismatic flow, turbulent flow and others in ADC. This study comes up with the weir equation is more suitable for the characteristics of Jeju-do could be presented through an observations of baseflow discharge.

A Study on the Characteristics of Physical and the Adsorption of Heavy Metals (갯벌의 물리적 특성과 중금속 흡착에 관한 연구)

  • Na, Young;Lee, Seong-Baeg
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.3
    • /
    • pp.25-33
    • /
    • 2001
  • The study was performed to examine the influence of sea tide on a tideland composition by Saemankeum reclamation and to evaluate a correlation between the characteristics of physical and the pollution level of heavy metals. Also, it was investigated the characteristics of heavy metal adsorption through a batch experiment and applied to adsorption isotherm equations. In the results, the flow of sea tide occurred to accumulation action and had an effect on the content of heavy metals. It suggests that influence factors for the content of heavy metals in the tidal flat be grain size, cation exchange capacity and organic matter content. Adsorption capacity of heavy metals occurs to 90% adsorption rate for injection concentration within 30 minutes. The flow patterns in Saemankeum area will undergo a change for soil size distribution. In result, this soil size changed will effect the adsorption capacity of heavy metals.

  • PDF

Study on Concentration Variation of 222Rn for Various Scintillators Using Low-Level Liquid Scintillation Counter (저 준위 액체섬광계수기를 이용한 섬광체 종류에 따른 222Rn 농도 변화 연구)

  • Jeon, JaeWan;Lee, Deuk-Hee;Kim, Jin-Seop
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.847-856
    • /
    • 2019
  • The various environmental issues arose with the development of today's economy. naturally, people were increased interest in environment and the importance of research on drinking water and contamination are emerging especially. A number of country areas, uranium and 222Rn in ground water have been detected to people using as drinking water. So this study evaluated the way for more accurate measurements than when measuring 222Rn concentrations in the ground water containing. the experiment was performed using the low-level liquid scintillation counter with an alpha, beta analysis easy PSA function of pulse. the scintillator as the preparation of the ground water samples are mixed, the measure value detection is lowered over prepare period and expiration date. Energy spectrum was also moved to a lower side channel. As a long time to buy the scintillator and over time after opening, it was confirmed that detection is lowered. if the purpose is to use a different scintillator can see the energy through the channel change.

Analysis of long-term water level change of Dongrae hot spring using time series methods (시계열 방법을 이용한 동래온천 수위의 장기적인 변화 분석)

  • Jeon, Hang-Tak;Hamm, Se-Yeong;Cheong, Jae-Yeol;Lee, Cheol-Woo;Lee, Jong-Tae;Lim, Woo-Ri
    • Journal of the Geological Society of Korea
    • /
    • v.54 no.5
    • /
    • pp.529-544
    • /
    • 2018
  • Dongrae hot spring belongs to the residual magma type and has a long history of bathing since the Silla dynasty in Korea. Due to long development of hot spring water, it is expected that the amount of hot spring water in Dongrae hot spring has been changed. In this study, long-trem water level data of Dongrae hot spring were examined for recognizing the change of the hot spring. By the fluctuation analysis of the hot spring water level from January 1992 to July 2018, the maximum and minimum annual drawdowns of no. 27 well were 137.70 and 71.60 meters, respectively, with an average drawdown of 103.39 m. On the other hand, the maximum and minimum annual drawdowns of no. 29 well were 137.80 and 71.70 meters, with an average drawdown of 103.49 m. Besides, drawdown rate became bigger in recent years. As a result of analyzing autocorrelation of the two wells, the correlation coefficient ranged from 0.919 to 0.991, showing seasonal groundwater level fluctuation. The cross correlation analysis between water level and precipitation as well as water level and hot spring discharge resulted in the correlation coefficients of -0.280 ~ 0.256 and 0.428 ~ 0.553, respectively. Therefore, using Dongnae hot-spring water level data from 1992 to 2018, the Mann-Kendall test and Sen's test showed that the continuous decline of water level was mainly caused by the pumping of the hot spring water among various reasons.

A Process-based Relative Sea-level Budget Along the Coast of Korean Peninsula Over 1993-2018 (1993-2018년 한반도 연안 상대해수면 수지 분석)

  • Hyeonsoo Cha;Seongbae Jo;Jae-Hong Moon
    • Ocean and Polar Research
    • /
    • v.46 no.1
    • /
    • pp.31-42
    • /
    • 2024
  • Due to physical processes varying in space and time, regional sea-level rise (SLR) significantly deviates from the global mean. Thus, understanding and quantifying the contribution of each process to regional sea-level change is crucial to prevent low-lying inundation in preparation for future ocean conditions. In this study, we assessed to what degree sterodynamic (SD) effects (i.e., density-driven steric expansion and mass redistribution due to ocean circulation), contemporary mass redistribution (CMR), and glacial isostatic adjustment (GIA) contribute relative sea-level rise around the Korean coast from 1993 to 2018, with independent observations and reanalysis datasets. The assessment showed that the tide gauge-observed SLR trend can be explained by the sum of each component at 16 of 19 locations. The major contributors to relative SLR are SD effects of 2.03±0.27 mm/yr and CMR components of 1.31±0.05 mm/yr, while GIA drives sea-level decreasing of -0.27±0.15 mm/yr on the Korean coast. It was also found that the spatial deviations of SLR are primarily caused by the SD effects. In addition, the evaluation of vertical land motion (VLM) based on altimetry and tide gauge indicates that most tide gauge locations have experienced uplift during at least altimetry period, whereas Wido station has experienced particularly high rate of subsidence that contributed to the SLR acceleration. Further examination of the impact of earth deformation due to CMR, GIA, and local process on the VLM trends demonstrated that the GIA and CMR contribute to land uplift with the average of 0.35±0.15 mm/yr and 0.17±0.05 mm/yr, respectively. On the other hand, the local processes like groundwater depletion and sediment compaction showed a wide range of variability, from -1.61 to 0.58 mm/yr, indicating a significant contribution to regional differences in vertical land motion.

Technological Development Trends for Underground Safety in Urban Construction (도심지 공사시 지하안전 확보를 위한 기술개발 동향)

  • Baek, Yong;Kim, Woo Seok
    • Tunnel and Underground Space
    • /
    • v.27 no.6
    • /
    • pp.343-350
    • /
    • 2017
  • Amid increasingly saturated ground space, development of underground space has been booming throughout the world and excavation has been underway near the structure above or under the ground level. But the ground subsidence caused by improper or poor construction technologies, underground water leakage, sudden changes of stratum and the problem with earth retaining system component has been emerged as hot social issue. To deal with such problems nationwide, establishment of preventive and proactive disaster management and rapid restoration system has been pushed now. In this study, collection of the data on technology development trend to secure the underground safety was made, taking into account of internal change elements (changing groundwater level, damage to underground utilities, etc) and external change elements (vehicle load, earthquake and ground excavation, etc) during excavation. Amid the growing need of ground behavior analysis, ground subsidence evaluation technology, safe excavation to prevent ground subsidence and reinforcement technology, improvement of rapid restoration technology in preparation for ground subsidence and development of independent capability, this study is intended to introduce the technology development in a bid to prevent the ground subsidence during excavation. It's categorized into prediction/evaluation technology, complex detect technology, waterproof reinforcement technology, rapid restoration technology and excavation technology which, in part, has been in process now.

Analysis of groundwater level change using groundwater monitoring network in Miryang area. (지하수관측망을 이용한 밀양지역의 지하수 변화 분석)

  • Baek, Mi Kyung;Sim, Gyu Sung;Kim, Sang Min
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.221-221
    • /
    • 2019
  • 기후변화로 인한 가뭄대비가 상시체제가 된 요즈음, 농업용수의 안정적인 공급을 위하여 가뭄 등의 비상시 지표수는 물론이고 지하수의 공급 가능량에 대해서도 국가적 관리가 필요한 실정이다. 지하수관리를 위해 국가 최상위 계획인'지하수관리기본계획(2012~2021)'이 수립되었고, 지하수의 장기적인 수량, 수질 관리를 위해 국가지하수관측망, 지역지하수관측망(보조지하수관측망), 수질측정망, 해수침투관측망 등 광역과 지역단위로 크게 나누어 지하수관측이 이루어지고 있다. 국가지하수관측망은 지하수법에 의거하여 전국의 주요지점(2016년 말 기준 412개소)에 관측소를 설치하여 수위 및 수질의 변동실태를 광역적으로 분석함이 목적이며, 보조지하수관측망은 국가지하수관측망과 연계하고 보완하기 위한 기능으로서, 지역별 주요 관측지점의 수위, 수질자료를 획득하며, 2018년 9월 현재 3,429개소가 설치되어있다. 본 연구에서는 지역지하수 관측망 중 경남밀양지역에 설치된 관측정 31개소에 대해 수위와 수질을 장기 분석하였다. 밀양지역의 보조지하수관측망 설치는 지하수관리계획의 하부계획인'경상남도 지하수관리계획(2015~2025)'에 의거 2012년에 6개소의 관측공이 설치를 시작으로, 2013년 7개소, 2014년 10개소, 2015년 8개소를 설치하여 총 31개소의 설치를 완료하였고, 2016년부터 2019년 현재까지 전체 관측정 31개소에 대하여 관측 운영 중이다. 본 연구에서는 2013년 1월~2019년 1월까지 지역의 누적강수량과 지하수위 및 수질변화를 관측하였다. 전 관측정에 대해 수위(GL.m), 수질(온도, EC)은 1시간 주기로 관측하였으며, 연 2회 생활용수 기준(19항목)의 수질검사를 실시하고, 지하수성분의 지질학적 기원분석을 위한 양음이온 분석을 연 1회 실시하였다. 관측정의 양수능력 변화관측을 위해 대수성 시험을 연 1회 실시하였고, 관측정의 특성상 장기간 미사용 관정이므로 최적의 상태유지를 위해 연1회 공내세척을 실시하였다. 또한, 관측정의 지형별 차이를 분석하기 위해 관측정의 설치위치를 산악, 강변, 기타 지역으로 구분하고, 각각의 대표관정에 대해 지형에 의한 서로 다른 영향을 분석하였고, 관측정의 심도별 변화를 알기위해 동일지역에 충적, 안반 관측정을 따로 설치하고 관측하여 지표수와 지하수의 심도별 영향의 차이를 분석하였다. 동일지역의 관측결과 평균 5m이하의 수위변화를 보이나, 5m 이상의 수위변동을 보이는 관측망은 15년 14개소 17년 19개소로 증가추세를 보이며, 이는 주로 밀집된 시설하우스 단지의 수막재배를 위한 겨울철 지하수 사용량 증가가 원인인 것으로 판단된다. 밀양지역은 강변지역에 밀집된 시설하우스단지의 동절기 수막재배를 위한 지하수 과다사용으로 수위급감 및 수량부족현상이 반복되고 있어, 예방과 대책강구를 위해 지표수의 함양과 지하수사용량의 상관관계 분석과 자료축적 및 추가연구를 위한 장기관측이 요구된다.

  • PDF

Understanding Chemical Characteristics of Seepage Water and Groundwater in a Coastal LPG Storage Cavern using Factor and Cluster Analyses (인자 및 군집분석을 통한 해안 LPG공동 유출수 및 지하수 수질특성의 이해)

  • Jo, Yun-Ju;Lee, Jin-Yong
    • Economic and Environmental Geology
    • /
    • v.42 no.6
    • /
    • pp.599-608
    • /
    • 2009
  • This study was conducted to examine chemical characteristics and correlations among seepage water, subsurface waters and inland groundwater in and around a coastal underground LPG cavern using factor and cluster analyses. The study area is located in western coast of Incheon metropolitan city and is about 8 km off the coast. The LPG cavern storing propane and butane was built beneath artificially reclaimed island. Mean bathymetry is 8.5 m and maximum sea level change is 10 m. Water sampling was conducted in May and August, 2006 from 22 sampling points. Correlation analysis showed strong correlations among $Fe^{2+}$ and $Mn^{2+}$ (r=0.83~0.99), and Na and Cl (r=0.70~0.97), which indicated reductive dissolution of iron and manganese bearing minerals and seawater ingression effect, respectively. According to factor analysis, Factors 1 (May) and I (August) showed high loadings for parameters representing seawater ingression into the cavern and effect of submarine groundwater discharge, respectively while Factors 2 and IV showed high loadings for those representing oxidation condition (DO and ORP). Factors 4 and II have large positive loadings for $Fe^{2+}$ and $Mn^{2+}$. The increase of $Fe^{2+}$ and $Mn^{2+}$ was related to decomposition of organic matter and subsequent their dissolution under reduced condition. Cluster analysis showed the resulting 6 groups for May and 5 groups for August, which mainly included groups of inland groundwater, cavern seepage water, sea water and subsurface water in the LPG storage cavern. Subsurface water (Group 2 and Group III) around the underground storage cavern showed high EC and major ions contents, which represents the seawater effect. Cavern seepage water (Group 5 and Group II) showed a reduced condition (low DO and negative ORP) and higher levels of $Fe^{2+}$ and $Mn^{2+}$.

Characteristics of Subsurface Movement and Safety of the Songsanri Tomb Site of the Baekje Dynasty using Tiltmeter System (경사도변화 계측을 통한 백제 송산리 고분군의 지하 벽체거동특성과 안정성)

  • 서만철;박은주
    • The Journal of Engineering Geology
    • /
    • v.7 no.3
    • /
    • pp.191-205
    • /
    • 1997
  • Measurements on subsurface movement of the Songsanri tomb site including the Muryong royal tomb was conducted using a tiltmeter system for the period of 15 months form July 7, 1996 to September 30, 1997. Two coordinate tilt monitoring data shows the biggest movement rate of 2.3mm/m/yr toward south in the frontal wall(N-S tilt) of the Muryong royal tomb. Southward tilting of bricks above the southern fire place in the western wall of the Muryong royal tomb is a proof of southward tilting of the royal tomb since its excavation in 1971. The eastern wall of the Muryong royal tomb is also tilting toward inside the tomb with the rate of 1.523mm/m/yr. Furthermore, tilting rate of wall increases twice in rainy season. It is interpreted tbat infiltration of water into the tomb and nearby ground in rainy season results in dangerous status for the safety of tomb structure. On the whole, normal component tilting of the walls of the 5th tomb is large than its shear component. It shows a small displacement toward one direction without no abrupt change in its direction and amount of tilting. The tilting rate of walls of the 6th tomb is about 8.8mm/m/yr in the dry season which is much bigger than those of other tombs in rainy season. Deformation events of walls of the tombs are closely related to amount of precipitation and variation of temperature. In comparison with different weather conditions, tilting is much bigger during the period of rainy weather than sunny weather. It is interpreted that rainwater flew into the turm through faults and nearby ground. High water content in nearby ground resulted strength of ground. The tilting event of walls shows a hysterisis phenomenon in analysis of temperature effect on tilting event. The walls tilt rapidly with steep rising of temperature, but the tilted walls do not come back to original position with temperature falling. Therefore, a factor of steep increase of the temperature must be removed. It means the tomb have to be kept with constant temperature. The observation of groundwater level using three boreholes located in construction site and original ground represented that groundwater level in construction site is higher than that of original ground during the rainy season from the end of June to August. It means that the drainage system of the Muryong royal tomb is worse than original ground, and it is interpreted that the poor drainage system is related to safety of tomb structure. As above mentioned, it is interpreted that artificial changes of the tomb environment since the excavation, infiltration of rainwater and groundwater into the tomb site and poor drainage system had resulted in dangerous situation for the tomb structure. According to the result of the long period observation for the tomb site, it is interpreted that protection of the tomb site from high water content should be carried out at first, and the rise of temperature by means of the dehumidifier inside the tomb must be removed.

  • PDF

Evaluation on the leakage of ground-water through fractured rock under a spillway (여수로 구조물 하부 암반 내 발달한 절리들을 통한 지하수 누수량 분석)

  • Kim, Hyoung-Soo;Lee, Ju-Hyun;Jeong, Ui-Jin;Lee, Joong-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.69-74
    • /
    • 2006
  • Recently, spillways are need to control stable water level for supporting main dams because of floods by unusual change of weather such as Typhoon Rusa. This study has been focused on the amount of leakage through the rock mass distributed fractures and joints under the opened emergency spillway. It is very important to evaluate the amount of leakage as these affect stability of spillway by interaction between effective stress and pore pressure. The commercial program MAFIC has been used for analyzing groundwater flow in fractured rock mass. The results showed that the values of range, average and deviation of leakage were $2.85\sim\;3.79\times10^{-1}$, $3.32\times10^{-1}$ and $1.70\times10^{-2}\;m^3/day/m^2$ respectively. Secondary, we have estimated the effect of grouting after the transmissivity$(T_f)$ of joint 1 as main pathway of leakage known from above results was changed from $1.78\times10^{-7}$ to $1.59\times10^{-9}\;m^2/s$. The results showed that the values of range, average and deviation of leakage were $7.80\times10^{-4}\sim1.53\times10^{-3}$, $1.18\times10^{-3}$ and $1.32\times10^{-4}\;m^3/day/m^2$ respectively. As the result, the amount of leakage after grouting has been decreased by a ratio of 1 to 277.

  • PDF