• 제목/요약/키워드: grounding system

검색결과 467건 처리시간 0.022초

EMTP를 이용한 지중 송전 케이블의 시스 순환전류 분석 (EMTP-Analysis of Sheath Circulating Current on Underground Transmission Cables)

  • 하체웅;김정년;이수길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.213-215
    • /
    • 2001
  • This paper describes an improved analysis method for sheath circulating current on three-underground transmission cables using EMTP(Electromagnetic Transient Program). Author studied diversely the sheath circulating current on three-underground cables depending on the various length rate, the phase arrangement, and the grounding resistance of the sheath in the cross-bonded section. It was clear that very large circulating current is generated in cable systems due to unbalanced length rate and phase arrangement in the cross-bonded section. The analysing method for two or more underground cables will be really Improved for cable system utility.

  • PDF

서울월드컵경기장 전기설계 (Seoul World Cup Stadium Electric Plan)

  • 최용민
    • 기술사
    • /
    • 제34권5호
    • /
    • pp.40-43
    • /
    • 2001
  • 상암동 월드컵 주정기장은 축구 전용경기장으로서 2002년 월드컵 축구경기를 위한 꿈과 감동의 라이브 스테이지로서의 스타디움 시설로 각종 국내외 축구경기는 물론 문화행사를 효율적으로 운영할 수 있도록 계획되었다. 이에 효율적인 경기장 시스템 구성과 적정한 전기시설물 설치로 최상의 경기운영을 할 수 있도록 전력시스템을 안정화 하였으며, 월드컵 경기 이후 스포츠공간과 상업시설, 공공시설 등 복합화된 스포츠 문화시설에 부합할 수 있도록 수변전 설비 및 방재센타 등을 다분화하여 시설하였으며 국제적 행사의 장에 전기인으로서 일익을 담당할 수 있었음에 감사한 마음이다.

  • PDF

철도고배 전송선로 분로리액터 설치에 대한 모델링 (A modelling on Shunt Reactors in Railway Power Transmission System)

  • 이종수;이종우
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1262-1268
    • /
    • 2015
  • I In power transmission systems, voltage changes continuously as reactive power is whether over supply or shortage. Reactive power produces in generators and consumes in transmission lines, and loads. Voltages at end points of transmission lines rise which is called Ferranti effect. Excessive voltage rising can reduce transmission equipment life, the voltage rising is usually permitted within the limit of 10%~30% excess. Shunt reactors are installed in transmission lines to put a curb on voltage rising. In this paper, we tried to do modelling for shunt reactor configuration types which are no grounding, grounded and grouded neutral reactor. Simulation are carried out for reactor magnitude for compensating transmission line capacitance.

전차선로에서의 뇌격에 의한 가공지선과 피뢰기의 차폐효과 (Effects of an Overhead Ground Wire and Surge Arrester in the Railway due to Lightning Strokes)

  • 임성정;한병덕;오정환;윤상윤;김재철;정용철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.468-470
    • /
    • 1999
  • Using the EMTP(Electro Magnetic Transient Program) for the analysis of lightning direct voltage on the railway system, the shielding effects of overhead grounding wire on the railway were studied quantitatively. Installation of overhead ground wire and sap-type arrester such as s-horn provides a 6.6kV HV distribution line with goof protection effects. Even severe lightning induced voltage were create, 6.6kV HV lines can be withstand.

  • PDF

정상시 접지계통의 접지 임피던스 특성 (Ground Impedance Characteristics for Grounding System on Power Substation)

  • 김재이;고영혁;고영권;김정부;정길조;기현찬;최종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2207-2209
    • /
    • 2000
  • 본 논문에서는 접지 모델을 활용하여 접지계의 임펄스 임피던스를 계산하고, 선로 임피던스에 연결된 접지 임피던스의 반사계수를 계산하여 대지로 유입되는 분류율을 평가하였다. 따라서 접지 저항을 낮추는 경우 평상시 전위 상승효과를 줄일 수는 있지만 위험전압의 인가시에는 인축의 안전과 기기의 절연 측면에서 악조건의 상황이 될 수 있다. 또한 접지 모델에서 용량의 변화와 접지 저항의 변화에 따른 반사계수의 변화를 확인하였고, 상용 주파수 근처에서는 저항 성분만 존재하고 리액턴스 효과는 없음을 확인하였다.

  • PDF

HID 램프용 안정기의 점화기 특성부석 및 제어용 IC의 동작영향 분석 (Ignitors analysis of characteristics in the ballast of the HID lamps and analysis of its effect on the control IC operations)

  • 박종연;임병노
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.9-14
    • /
    • 2007
  • In this paper, four types of igniters were modeled and their characteristics were researched. And then we analyzed and experimented the effect on the control IC operation in this system. Due to the high ignition voltage, the DC power line on control IC is contaminated with the impulsive noise voltage. So the control IC operation is stopped. Therefore we have found that contamination of DC power noise is reduced by shielding, grounding pattern, and filtering method. We showed that the experimental results are agreed with the theoritical value obtained by the four types of ignitor models.

  • PDF

국내 송전 케이블 시스 순환전류 실측 및 분석 (Measurement and Analysis of Sheath Circulating Current in Domestic Underground Transmission Cables)

  • 하체웅;김정년;이수길;김동욱;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권4호
    • /
    • pp.193-200
    • /
    • 2003
  • The use of underground transmission tables has continuously increased in densely inhabited urban and suburban area. Due to a increasing demand of underground cables, two or more circuits are installed in parallel for several kilometers. It, however, has not been realized that the sheath circulating current is generated in the system where a large number of cables are laid in the same route. In this paper, Author studied diversely the sheath circulating current on underground cables depending on the various length rate, the phase arrangement, and the grounding resistance of the sheath in the cross-bonded section. It was clear that very large circulating current is generated in cable systems due to unbalanced length rate and phase arrangement in the cross-bonded section.

노이즈 및 서지제거를 위한 접지시스템 설계 엔지니어링 (Engineering of Grounding System Design for Protection of Surge & Noise)

  • 조대훈;이기식;정철희;유청희;박우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.5-9
    • /
    • 2007
  • 본 논문에서는 실제 운용 중인 현장에서 노이즈 및 서지 신호를 측정 분석하여, 그 결과를 토대로 이들 노이즈 신호를 제거할 수 있는 접지시스템 및 내부 보호 설비를 제안하여 시공하였다. 실제 운용 중인 설비 내에 유도 흑은 침입하는 전원 계통의 sag, Swell, Transient, 서지 그리고 고조파와 같은 노이즈와 접지시스템을 통해 유입되는 다양한 노이즈 신호를 차단하여 빠르고 안전하게 제거하는 방안을 연구하였다. 이를 위해 운용 중인 설비의 다양한 노이즈 신호를 실측하였고, 실측된 결과로부터 전달 및 침입 경로를 예측하여, 기존 접지 구성 및 내부 배선의 문제점의 개선하고 노이즈 및 서지의 실제적 차단을 위한 접지시스템과 내부 보호 설비를 설계 제안하였다. 또한 설계 시뮬레이션 결과와 현장 시공 결과를 비교하여 제안된 설비의 성능을 확인하였고, 시공 후 설비 운용 중에 노이즈 및 서지 신호를 재 측정하여 기존 설비 운용시 측정했던 결과를 비교 분석하여 제안 보호 설비의 개선된 성능을 최종 확인하였다.

  • PDF

회로모델을 이용한 봉상전극 접지임피던스의 분석 (Analysis of Ground Impedance of a Ground Rod Using Circuit Models)

  • 이복희;이태형;엄주홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.95-99
    • /
    • 2004
  • A systematic approach of measurement, modeling and analysis of grounding system impedance in the field of lightning protection systems is presented. The measurement and analysis of ground impedance are based on a computer aided technique. The magnitude and phase of ground impedance were measured and analyzed by the modified fall-of-potential method and the proposed computer program algerian using the waveforms of the test current and potential rise. The theoretical analysis of ground impedance were performed with the equivalent circuit models, and the theoretical results were compared with the measured data.

  • PDF

초전도 전력케이블의 전류 불평형에 관한 연구 (A Study on the Unbalanced Current Distribution of HTS Power Cable)

  • 김재호;박충화
    • 한국안전학회지
    • /
    • 제27권6호
    • /
    • pp.43-47
    • /
    • 2012
  • The unbalance currents flow the High Temperature Superconducting (HTS) power cable caused by asymmetrical fault, harmonic distortion and unbalanced load. That problem causes additional loss and leakage field in the HTS power cable, and deteriorates the electric power quality and stability. In addition, large amounts of unbalanced current can cause negative sequence and ground relays to operate. This paper presents an analysis unbalanced three-phase current distribution in HTS power cable caused by unbalanced load condition and grounding methods using PSCAD/EMTDC. The results obtained through the analysis would provide important data for the design of HTS power cables and valid information for their installation in power system.