A Novel Non-contact Measurement Method for the Detection of Current Flowing Through Concealed Conductors

  • Yang, Fan;Liu, Kai;Zhu, Liwei;Hu, Jiayuan;Wang, Xiaoyu;Shen, Xiaoming;Luo, Hanwu;Ammad, Jadoon
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.43-48
    • /
    • 2017
  • In order to detect the current flowing through concealed conductor, this paper proposes a new method based on derivative method. Firstly, this paper analyzes the main peak characteristic of the derivative function of magnetic field generated by a current-carrying conductor, and a relationship between the current flowing through the conductor and the main peak of the derivative function is obtained and applied to calculate the current. Then, the method is applied to detect the conductor current flowing through grounding grids of substations. Finally, the numerical experimental and field experiment verified the feasibility and accuracy of the method, and the computing results show that the method can effectively measure the conductor current of grounding grids with low error, and the error is within 5 %.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

An Analysis of the Ground Surface Potential Rise and Hazardous Voltages Caused by Impulse Currents (임펄스전류에 의한 대지표면전위상승 및 위험전압의 분석)

  • Lee, Bok-Hee;Lee, Kyu-Sun;Choi, Jong-Hyuk;Seong, Chang-Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.117-123
    • /
    • 2011
  • Lightning and switching surges propagating through the grounding conductors lead to transient overvoltages, and electronic circuits in information technology systems are very susceptible to damage or malfunction from the electrical surges. Surge damages or malfunctions of electrical and electronic equipment may be caused by potential rises. To solve these problems, it is very important to evaluate the ground surface potential rises and hazardous voltages such as touch and step voltages at or near the grounding systems energized by electrical surges. In this paper, the performance of grounding systems against the surge current containing high frequency components on the basis of the actual-sized tests is presented. The ground surface potential rises and hazardous voltages depending on impulse currents for vertical or horizontal grounding electrodes are measured and analyzed. Also the touch and step voltages caused by the impulse currents are investigated. As a result, the ground surface potential rises, the touch and step voltages near the grounding electrodes are raised and the conventional grounding impedances are increased as the front time of the injected impulse currents is getting faster.

Design and A Safety Analysis and Assessment of a Grounding System according to International Standards (국제 표준(IEC)에 의한 접지 설계 및 이에 대한 안전성 분석·평가)

  • Kim, Doo-Ung;Cho, Man-Hyung;Kim, Han-Soo;Shin, Dae-Sung;Ryu, Ki-Hwan;Kim, Chul-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.54-59
    • /
    • 2015
  • In this paper, we evaluate safety of grounding system which is designed according to IEC standards. Safety assessment of construction site and grounding system of building is needed before construction for the safety of human in building. Until now, in case of domestic field, design of grounding system is proceeded based on methods which are proposed in IEEE Std. 80. In other words, it is not in the situation that grounding system is designed based on IEC standards. Therefore, we propose a method which designs grounding system and evaluates safety of it according to IEC standards. We measure ground resistance of construction site using measuring equipment of ground resistance. Using this value, soil structure and ground resistivity are obtained through program analysis. CDEGS program of SES company is used for simulation analysis.

A Study on a grounding system of electric railway (전기철도 접지시스템에 대한 연구)

  • Lee, Ho-Jong;Shin, Myoung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1482-1504
    • /
    • 2007
  • An electrical railway system uses high voltage system for train traction and low voltage system for train control. Railway systems are broadly distributed across mountains, sea sides and cities. Electrical accidents provoke the death and injury of a human being and the damage of the equipment by the overcurrent due to the catenary dropping and by the overvoltage due to lightning. Grounding systems are adopted for the protections of the system from the overcurrent and the overvoltage. Isolation grounding for each system can be easily installed. However, the closed circuits between grounding systems can be occurred. The currents flow through the closed circuits cause the abnormal operation of the system. To overcome the problem of the isolation grounding, the equipotential bonding is usually adopted. The equipotential bonding should have very small grounding resistance. In this paper, we showed the transition from the isolation grounding system to the common grounding system and presented the comparison and the analysis of two grounding systems by simulation. In addition, we proposed the direction for a new grounding system of electric railway.

  • PDF

A Study on the Grounding Resistance Effects of Power Transformer in Electric Distribution Systems (배전계통에서 전력용 변압기의 접지저항 영향에 관한 연구)

  • Kim, Kyung-Chul;Jung, Ji-Won;Lee, Kyu-Jin;Lee, Kang-Soo;Choi, Sun-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.113-119
    • /
    • 2010
  • A safe grounding design is used for providing means to carry electric currents into the earth under fault conditions without exceeding any operating limits and for assuring that a person in the vicinity of grounded facilities is not exposed to danger of critical electrical shock. Transformer neutral point grounding is for the purpose of controlling the voltage to earth within tolerable limits under a line-to-ground fault. Transformer frame grounding is for the purpose of minimizing the hazardous potential within safety criteria appearing at the faulted equipment. ills paper deeply investigates the grounding resistance effects of distribution power transformers by analysing the neutral to eatth voltages and touch voltages when the fault occurs.

The Construction of Safety Measurement Equipment of Grounding Electrode for Distribution System (배전용 접지전극의 안전성 분석 장치 구성)

  • Kang, Moon-Ho;Park, Young-Keun;Jang, Sang-Ok;Won, Yoon-Chan;Lee, Heung-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.218-221
    • /
    • 2005
  • Grounding electrodes as discharge paths to the earth are normally used to ensure the safety of human body and facilities from the over-voltages in distribution power system, and each grounding mode has a prescribed ground resistance value respectively which is applied by the utilities. As the various electrodes for distribution power system are recently developing to improve the performance of them and resolve the problem of space restriction, it is necessary to measure and investigate the safety of human body of developed electrodes. Therefore, in this paper, we provide briefly a technical comparison of two standards, i.e. IEEE Std 80 and the IEC 479-1, and describe the configuration of safety measurement system which can measure the step voltage and the touch voltage of grounding electrodes based on IEEE Std 80.

  • PDF

Analysis on the Method of Forward-Reverse Fault localization of Electric Railways for the Improvement of Accuracy (전기철도 정역방향 고장점표정 방법을 통한 정확도 향상을 위한 연구)

  • Kim, Myeong Su;Kim, Seong Cheol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1735-1742
    • /
    • 2018
  • The number of electric railway failures will increase due to the external and internal effects of electric railroads. The grounding test with 25,000V is to artificially test the transmission voltage to ground, and it is possible to cause risks of electric shock and other equipment insulation damage in neighboring enclosure. In 2016, method of fault localization changed to low - voltage at 380V from artificially high- voltage in the grounding tests since opening of Seoul Metropolitan Express Railway; The method is more accurate and safer rather than the previous one because it gets more data from unlimited grounding tests. However, an electric current falls on the track section where the track branches and vehicle bases with many lines. To precisely detect a transitive phenomenon, it is necessary to continuously study and additionally install.

Analysis of Human Safety and System Effect according to Grounding Scheme in LVDC Distribution System (LVDC 배전계통의 접지방식에 따른 인체안전 및 계통영향 분석)

  • Oh, Yun-Sik;Han, Joon;Gwon, Gi-Hyeon;Kim, Doo-Ung;Noh, Chul-Ho;Jung, Tack-Hyun;Kim, Chul-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.5
    • /
    • pp.608-614
    • /
    • 2014
  • Recent developments and trends in the electric power consumption clearly indicate an increasing use of DC in end-user equipment. According to the trends, new DC power distribution systems have been researched and developed although we presently enjoy a predominantly AC power distribution system. We can use various grounding schemes in DC distribution system as well as in AC distribution system to protect human body and equipments. However, we need to evaluate carefully which grounding scheme is appropriate for a specific system before applying those schemes. In this paper, we analyze the human safety and system effect according to various grounding schemes in Low Voltage DC (LVDC) distribution system. Some components in LVDC distribution system are modeled and computer simulations are conducted by using ElectroMagnetic Transient Program (EMTP).

구내통신 설비에 대한 접지 및 본딩 기술표준안

  • Kim, Nam;Lee, Hui-Sook;Yang, Su-Gyeong;Ryu, Myeong-Ju;Kim, Chang-Rak;Seo, Tae-Seok
    • Information and Communications Magazine
    • /
    • v.16 no.5
    • /
    • pp.114-127
    • /
    • 1999
  • Telecommunications provisions of the interior of a country which are established only for a voice service are inefficient in various rule of grounding and bonding that are not concerned with services. It is a essential part for planning out a efficiency when employing telecommunication, researching and writing standards bout grounding and bonding of materials that are established in telecommunication to consider reliability of telecommunication equipment for a wideband and high speed service. Therefore we investigated present conditions and problems of domestic grounding and observed foreign technical standards related to several grounding and bonding. The foreign technical standards are compared with the domestic immature parts. As a result, presenting a domestic technical standards about grounding and bonding fitted to telecommunicateion provision when building is constructed or reconstructed, all parts related to this can be given the efficiency and the generality to provide system which has reliability.