• Title/Summary/Keyword: ground-water level

Search Result 608, Processing Time 0.026 seconds

The Research of Storage Capacity & Sedimentation of Reservoirs in HONAM Province (호남지방에 저수지의 매몰상황과 저수량에 관한 조사연구(농학계))

  • 이창구
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.2
    • /
    • pp.2262-2275
    • /
    • 1971
  • Fourteenes rervoirs maintained by the local land improvement associations in the province of Chullabuk-Do and 20 reservoir maintained by thos in the province of Chullanam-Do, were surveyed in connection with a correction between storage capacity and sediment deposit. In addition to this survey, 3,347 of small reservoir, that lie scattered around in the above-mentioned two provinces were investigated by using existing two provinces were investigated by using existing records pertaining to storage capacity in the office of City and country, respectively. According to this investigation the following comclusions are derived. 1. A sediment deposition rate is high, being about $10.63m^3/ha$ of drainage area, and resulting in the average decreasc of storage capaity by 27.5%. This high rate of deposition coule be mainly attributed to the serve denudation of forests due to disorderly cuttings of trees. Easpecially, in small reservoir, an original average design storage depth of 197mm in irrigation water depth is decreased to about 140mm. 2. An average unit storage depth of 325.6mm as the time of initial construction is decreased to 226mm at present. This phenomena causes a greater shortage irrigation water, since it was assumed that original storage quantity was already in short. 3. Generally speaking, seepage rates through dam abutment intakepipe, etc, are high due to insufficient maintenance and management of reservoir. 4. It is recommended that sediment deposit should be dredged when a reservoir is dry in drought. 5. Farmers usually waste excessive irrigation water. 6. Water saving methods should be practiced by applying only necessary water for growing stage of rice. 7. In are as where water defficiency for irrigation is severe, a soil moisture content should be kept at about 70% by applying water once in several days. 8. Tube wells should be provided so as to exploit ground water and subsurface current below stream bed as much as possible. 9. If an intake weir was constructed, a water collection well should be built for the use in drought. 10. Water conservation should be forced by converting devastated forests contained in the drainage area of reservoir to protected forests so as to take priority of yrefor estation, gully control, the prohibition of disorderly cutting of trees, etc. 11. Collective rice nurseries should be adopted, and it should be recommended that irrigation water for rice nurseries is supplied by farmer themselves. 12. Sediment desposit in reservoir should be thoroughly dreged so as to secure a original design storage capacity. 13. The structure of overflow weir should be automatic so as to freely control flood level and not to increase dam height.

  • PDF

A Study on Soil Slope Stability Design Considering Seepage Analysis (침투해석을 고려한 비탈면 설계에 대한 연구)

  • Kim, You-Seong;Kim, Jae-Hong;Lee, Jin-Kwang;Kim, Seong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.1
    • /
    • pp.135-147
    • /
    • 2013
  • Most of slope failures are triggered by heavy rainfall during rainy season. If the rain keeps on for the season, the water content of the ground increases and its matric suction decrease, and then the safety factor of soil slope gets lower. The change of water table level for soil slope stability dose not describe the behavior of the soil slope in real situation, hence it may be necessary to modify the design standard for slope stability in association with rain infiltration. For correct design, economical construction, and maintenance of a soil slope, unsaturated flow analysis is needed for estimation of slope instability regarding water infiltration and soil behavior on unsaturated soil slopes. The entire soil slope cannot be saturated by prolonged rainfall and wetting band depth (saturated zone) just deepens from slope surface, hence the cause of the shallow surface slide is the wetting band depth depending on rainfall duration and intensity. Therefore, the paper presents the differences between theoretical equation and numerical analysis for wetting band depth on soil surface and its safety factor, and compares the slope stability obtained from unsaturated flow analysis with that obtained from conventional slope stability analysis.

Comparison of Nitrogen Removal in a Horizontal Subsurface-Flow Wetland Purifying Stream Water with and without Litter Layer on its Surface (하천수를 정화하는 수평흐름 여과습지의 표면 잔재물층 유무에 의한 질소제거 비교)

  • Yang, Hongmo
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.12 no.1
    • /
    • pp.111-122
    • /
    • 2009
  • Abatements of TN and ${NO_3}^-$-N in a horizontal subsurface-flow wetland with litter layer on its surface were compared with those without one. The wetland was constructed in 2001 on floodplain of the Gwangju Stream which flows through Gwangju City in Korea. Its dimensions were 29m in length, 9m in width and 0.65m in depth. A bottom layer of 45cm was filled with crushed granites (15~40mm in diameter) and a middle layer of 10cm had pea pebbles. An upper layer of 5cm contained coarse sands. Reeds (Phragmites australis) growing in natural wetlands were transplanted on its surface. Water of the stream was channelled into the wetland by gravity flow and its effluent was discharged back into the stream. Average Litter layer of 12.2cm was formed on its surface in 2007. The layer and above-ground parts of reeds were eliminated in April 2008. Volumes and water quality of influent and effluent of the wetland were analyzed from May to November in 2007 and 2008, respectively. Inflow into the wetland both in 2007 and 2008 averaged approximately 40$m^3$/day and hydraulic residence time both in 2007 and 2008 was about 1.5days. Influent TN concentration in 2007 and 2008 averaged 3.96 and 3.89mg/L, respectively and average influent ${NO_3}^-$-N concentration in 2007 and 2008 was 2.11 and 2.05mg/L, respectively. With a 0.05 significance level, influent concentrations of TN and ${NO_3}^-$-N, temperatures and pH of effluent, and heights and stem numbers of reeds showed no difference between the wetland with litter layer and without one. TN retention in the wetland with litter layer and without one averaged 64,76 and 54.69%, respectively and ${NO_3}^-$-N removal averaged 60.83 and 50.61%, respectively. Both TN and ${NO_3}^-$-N abatement rates in the wetland with litter layer were significantly high (TN abatement: p<0,001, ${NO_3}^-$-N abatement: p=0.001) when compared with those without one. The subsurface-flow wetland having litter layer on its surface was more efficient for TN and ${NO_3}^-$-N removal.

A study on the Use of Low and Wet Land By Underdrainage(1) (암반비수에 의한 저온지이용에 관한 연구(1))

  • 주재홍
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.10 no.2
    • /
    • pp.1454-1459
    • /
    • 1968
  • Althow underdrainage has been studied for long time, it is the first attempt in Korea to execute using PVC(Plastic) suction pipes in the low and wet field. First, an execution plot and a control plot were set, and the drainage method and soil temprature in the excuted plot have been examined. The growth of crops and the yeild, the improvement of soil and water quality of irrigation are to be dealt during the next experimental period. The experimental method and the results obtained through the experimentations are as follows: Method 1) Depth: 1meter. interval: 5meters Trench was performed by labor. 2) PVC(plastic) sucking pipe filters were wound with glass nylon. 3) Two. horizontal looks were set in the 5a. plot. Results 1) The soil temprature in the excuted plot went up by $1.2^{\circ}C$ in average than in the control plot during the two years(1966-67) of irrigation period, and the maximum temprature raised a day was $3^{\circ}C$ 2) The under ground water level in the executed plot went down by 45cm. 3) The yield increases were 64% in potato, 57% in barley, and 21% in rice. The yield, soil, and the quality of irrigated water will be experimented during the next experemental period.

  • PDF

A Study on the Method for Ecological Restoration on Abandoned Concrete-paved Road - Focused on the Experimental Construction Site in Young Dong Province of GyungBu Express Highway(227.24~229.04km) - (콘크리트 폐도의 생태복원 방안 모색에 관한 연구 - 경부선 영동군 황간지역 시험시공지를 중심으로(경부고속도로 227.24~229.04km 지점) -)

  • Kim, Nam Choon;Ann, Phil Gun;No, Su Dae;Kim, Do Hee
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.15 no.4
    • /
    • pp.119-132
    • /
    • 2012
  • The unmanaged abandoned concrete roads are vulnerable toward the issues on soil and water pollution, which requires flexible managing method such as eco-corridor after the process of ecological restoration. Among various alternations of abandoned concrete-paved roads, ecological restoration technique may be the most suitable method in sites including high quality of natural environment. Therefore, as in Young dong province, GyungBu express highway (227.24~229.04km), which is near to Hwang-gan IC, the survey to measure its effect of soil under the paving and water pollution by abandoned concrete roads was discussed. Then, the restoration method of plantings of landscape trees and hydro-seeding methods of artificial soil media was appraised through consecutive monitoring. The soil adequacy analysis shows lower percentage of heavy metal substance in each depth level compared to standard limit stated by the Ministry of Environment, along with low concerns raised after the analysis on heavy metal content of the spilled water on the concrete roads. Meanwhile, Korean Weigela (Weigela subsessilis L.H. Baily) was found to be withered in small-scale landscape trees planting sites. Among the seeding plants. the family of leguminosae, Silene armeria, Dendranthema boreale, Caryopteris incana and Aster yomena show good establishment results. Overall studies on planting of small and large landscape trees, planting method of container plants, planting method of ground cover plants, and germination and development trend of seeding plants of the experimental restoration site on abandoned concrete roads are revealing specific trends in the way landscape woody plants establishment and growth. Finally, this study suggests further studies and survey on varied plant restoration methods on abandoned concrete-roads for developed design guidelines of their methods.

Effects of Artificial Acid Mist on Leaf Injury and Surface Wettability of Several Broad-Leaved Species (인공산성연무(人工酸性煙霧)의 처리(處理)가 몇 활엽수종(闊葉樹種)의 엽피해(葉被害)와 엽표면(葉表面)의 친수성(親水性)에 미치는 영향(影響))

  • Kim, Gab Tae;Um, Tae Won
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.4
    • /
    • pp.577-585
    • /
    • 1996
  • To seek effective methods for evaluating air pollution and acid rain injury, artificial acid mist(pH 2.5, 3.5 and 4.5) and ground water(pH 6.5) were treated on the potted seedlings of Ligustrum obtusifolium, Cercis chinensis, Hibiscus syriacus and Sophora japonica. Leaf chlorophyll contents, characteristics of leaf-injury, wettability-measurement of diameter of water-droplets on the leaf surface-among treatments were investigated. The results were summarized as follows. 1. Chlorophyll contents of Ligustrum obtusifolium and Hibiscus syriacus measured on June 3 were highest in pH 2.5 plot, but those of Cercis chinensis and Sophora japonica were relatively low level. Chlorophyll contents of Ligustrum obtusifolium measured on August 24 was highest in pH 2.5 plot, but those of Cercis chinensis, Hibiscus syriacus and Sophora japonica were highest in the control. 2. Changes of chlorophyll contents with acid mist treatments were differed among tree species. 3. For all the tested species, leaf injury(injured leaf number and rate, and injured leaf area) increased with decreasing pH levels of acid mist. 4. Leaf tissue injury seemed to be related with the wettability of the leaf surface. Measurement of diameter of water-droplets on the leaf surface might be useful criteria for acid rain or acid mist injury for the glabrous leaved species, such as, Cercis chinensis, Sophora japonica, etc.

  • PDF

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

The Effects of Negative Pressure and Drain Spacing in the Horizontal Method for an Early Settlement of Dredged and Filled Grounds (해안준설매립토의 조기안정을 위한 수평배수공법에서 부압과 배수재 배치간격의 영향)

  • 김수삼;한상재;김병일;김정기
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • In this paper, the laboratory test results with middle-sired ,soil box test in modeling the in-situ installing of horizontal drains are discussed the estimation of the optimum negative pressure. The test was carried out in the different vacuum pressure conditions together with the measurement for the settlement and volume change of drained water by the installed drains during the consolidation process. After the test, the water content was measured to both directions of lateral distance from the drain and depth of the soil, to find out the distribution of ground improvement and strength enhancement. From the analysis on the distribution of water content, the gradual application of vacuum pressure to higher level by pre-determined stages starting from low vacuum pressure is found to be effective and desirable. In the comparison of the degrees of consolidation with elapsed time, the calculated value by the prediction method based on the Barren's conventional theory showed a good agreement with the measured value. With this, It is positively considered that the applicability of the prediction method based on Barren's theory to the practical design of horizontal drains can be justified such as in the calculation of drain spacing and consolidation period.

Understory Evapotranspiration Measured by Eddy-Covariance in Gwangneung Deciduous and Coniferous Forests (광릉 활엽수림과 침엽수림에서 에디공분산으로 관측한 하부 군락의 증발산)

  • Kang, Min-Seok;Kwon, Hyo-Jung;Lim, Jong-Hwan;Kim, Joon
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.11 no.4
    • /
    • pp.233-246
    • /
    • 2009
  • The partitioning of evapotranspiration (ET) into evaporation (E) and transpiration (T) is critical in understanding the water cycle and the couplings between the cycles of energy, water, and carbon. In forests, the total ET measured above the canopy consists of T from both overstory and understory vegetation, and E from soil and the intercepted precipitation. To quantify their relative contributions, we have measured ET from the floors of deciduous and coniferous forests in Gwangneung using eddy covariance technique from 1 June 2008 to 31 May 2009. Due to smaller eddies that contribute to turbulent transfer near the ground, we performed a spectrum analysis and found that the errors associated with sensor separation were <10%. The annual sum of the understory ET was 59 mm (16% of total ET) in the deciduous forest and 43 mm (~7%) in the coniferous forest. Overall, the understory ET was not negligible except during the summer season when the plant area index was near its maximum. In both forest canopies, the decoupling factor ($\Omega$) was about ~0.15, indicating that the understory ET was controlled mainly by vapor pressure deficit and soil moisture content. The differences in the understory ET between the two forest canopies were due to different environmental conditions within the canopies, particularly the contrasting air humidity and soil water content. The non-negligible understory ET in the Gwangneung forests suggests that the dual source or multi-level models are required for the interpretation and modeling of surface exchange of mass and energy in these forests.

A field Study to Evaluate Cooling Effects of Green Facade under Different Irrigation Conditions - Focusing on modular green facade planted with Hedera helix L and Pachysandra terminalis - (관수조절에 의한 벽면녹화의 냉각효과 분석 연구- 아이비, 수호초를 식재한 모듈형 벽면녹화를 중심으로-)

  • Kim, Eun-Sub;Yun, Seok-Hwan;Piao, Zheng-gang;Jeon, Yoon-Ho;Kang, Hye-Won;Kim, Sang-Hyuck;Kim, Ji-Yeon;Lee, Young-Gu;Lee, Dong-Kun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.24 no.6
    • /
    • pp.121-132
    • /
    • 2021
  • Green facade has a significant impact on building's energy performance by controlling the absorption of solar radiation and improving outdoor thermal comfort through shading and evapotranspiration. In particular, since high-density building does not enough green space, green facade, and rooftop greening using artificial ground plants are highly utilized. However, the level of cooling effect according to plant traits and irrigation control is different. Therefore, in this study, the cooling effect analyzed for a total of 4 cases by controlling the irrigation condition based on hedera and spurge. Although hedera under sufficient water had the highest cooling effect(-2℃~-4℃), had the lowest cooling effect under non-irrigation(+1.1℃~+4.4℃). In addition, hedera under sufficient water had cooling effect than hedera under non-irrigation(-1℃~-8.1℃) and in the case of spurge, it had cooling effect(-0.3℃~-7.8℃) more than non-irrigation. As a result of measuring the amount of transpiration according to the light intensity (PAR) and carbon dioxide concentration conditions, transpiration of hedera was higher than the spurge (respectively 0.63204mmolm-2s-1, 0.674367mmolm-2s-1). The difference in the cooling effect of the green facade under irrigation condition was significant. But the potential cooling effect of green facade according to plants species was different. Therefore, in order to maximize and continuously provide the cooling effect of green facade in urban areas, it is necessary to consider the characteristics of plants and the control of water supply through the irrigation system.