• Title/Summary/Keyword: ground water pollution

Search Result 159, Processing Time 0.021 seconds

경남 시설원예지 농업용 지하수의 수질 현황 (Ground Water Pollution Status of Agricultural Water Source of Greenhouse Area in Gyeongnam)

  • 이성태;조주식
    • 한국환경과학회지
    • /
    • 제7권4호
    • /
    • pp.531-540
    • /
    • 1998
  • To examine water pollution status of agricultural water source of greenhouse area in Gyeongnam, the ground water quality was investigated six times at five areas in Gyeongnam from October in 1995 to March in 1996. pH of ground water were generally in the range of 5.9∼7.6. But a site in Changnyeong area was out of the range In 6.0∼8.5 which is water quality standard for agriculture. COD of ground water was below 2.8mg/l. NH4+-N contents in ground water was very low in all areas and the average of NO3'-N contents in Changnyeong and Chinju area was high with 13.2 and 11.5mg/l respectively. Hardness, SO42- and EC of ground water In Hmm were higher than any other area. Fe and Mn contents of ground water in Kimhae were higher than any other area with 7.17 and 0.95wt, respectively. Heavy metals such as Cu, Cd, Pb and Zn of ground waker were below water Quality standard far agriculture but some sites were over. Between COD and SS in ground water were not correlated with rInG.338,'but between COD and NH4+, -N were positively correlated. And EC was positively correlated with Ca2+, Mg2+ and SO42-. Ground water pollution status of agricultural water source of greenhouse area in Gyeongnam was genrrally high in order of Sacheon < Chinju < Hmn < Kimhae < Changnyeong.

  • PDF

GIS를 이용한 지하수관리시스템 개발 연구 (관정분석 프로그램, 지하수모델링 연계프로그램) (Development study of ground water management system making use of GIS ( Well analysis program, connection program of ground water modeling ))

  • 이병호;김양빈;설민구;송양권;송무영
    • 대한지질공학회:학술대회논문집
    • /
    • 대한지질공학회 2002년도 정기총회 및 학술발표회
    • /
    • pp.235-248
    • /
    • 2002
  • 지하수개발 기술의 발전과 생활여건 개선으로 지하수의 사용이 증가되면서 지하수에 대한 관리상 어려움과 여러 문제점들이 발생하고 있다. 지하수관리체계의 부실, 관리 인원의 부족, 무분별한 개발 등으로 지하수 오염 및 수량부족 현상이 가중되고 있고, 또한 지하수관 정의 관리가 어려워 지역적인 과잉개발이나 폐공이 방치되는 현상이 나타나고 있다. 본 논문은 GIS를 이용한 지하수관리의 시스템구축 모델을 제시하고, 지하수관리시스템에 필요한 분석기능 및 지하수관리 방법을 구현하여 효율적인 지하수관리가 이루어질 수 있도록 하는데 목적이 있다. 지하수개발의 위치정보를 기록하고 개발자료와 현장조사자료 등의 여러 자료를 D/B화 하였다. 또한 위성영상을 이용한 선구조 분석 자료와 수리시험 자료, 수질조사 자료 등을 활용하여 지역별 특성 값을 주제도로 작성하였고, 이러한 자료들을 활용하여 지하수 모델링 기초자료를 자동 생성할 수 있도록 하였다. 신규 지하수개발 위치에 대하여 주변의 지하수개발현황 및 오염원 현황, 선구조의 발달, 오염취약성도(DRASTIC), 수질조사 등의 자료를 손쉽게 파악할 수 있는 장점이 있다. 지하수관리시스템은 이러한 기능들을 이용하여 지하수개발 적지선정이 가능하다.

  • PDF

통계적 분석을 이용한 간이급수시설의 오염원에 관한 연구 (A Study on the Pollution Sources of Simple water Supply Piped System using Statistical Analysis)

  • 이홍근;김현용;백도현;김지영;이태호
    • 환경위생공학
    • /
    • 제14권2호
    • /
    • pp.56-67
    • /
    • 1999
  • This study was performed to suggest the basic data and plans for the establishment of safe water supply plans in simple water supply piped system in the rural areas. In 4 different places, 24 points of water sources 36 points of taps from water sources were sampled. Of the whole 60 points, 55 points were ground water and 5 points were surface water. 14 items were measured for the analysis of water quality on each samples. The measured items were analyzed again by statistical method ; cluster analysis and principle components analysis. The results of this study are as followed. 1) In water quality analysis on water sources, 4 items, bacteria, E.coli, NH3-N and Fe exceed the standard. Of 24 points, 20 points(83%) on bacteria, 1 point(4%) on NH3-N and Fe exceed the standard. 2) In water quality analysis on near and remote taps, 4 items, bacteria, E.coli, NH3-N and Fe , exceed the standard. Of 36 points, 20 points (81%) on bactria, 1 pint(3%) on NH3-N and Fe exceed the standard. 3)Cluster analysis on water quality shows the differences by the kinds of water sources, geographical characteristics and distance from water sources. 4) Principle components analysis on ground water shows that Factor 1 and Factor 3 are natural fluctuation by the content of soil. Also, Factor 2 and Factor 4 are penetration of pollutants to underground. Therefore, it is needed to take deeper ground water in order to prevent from pollution in the areas which have ground water as water source . 5) Principle components analysis on surface water shows that Factor 1 is penetration of vacteria from surface to water source when rainfalls. Also, Factor 2 is fluctuation of water quality by the geographical characteristics. Therefore, the counterplans against non-point pollution source must be taken. Filtration and disinfection facilities are needed in the areas which have surface water as water source.

  • PDF

이상적인 음료수 공급을 위한 수질관리에 관한 연구 (Study on the Water Management to get High Quality of Drinking Water)

  • 김형석;신현덕;박경석
    • 환경위생공학
    • /
    • 제6권1호
    • /
    • pp.7-25
    • /
    • 1991
  • Until now, pure drinking water grnerally menas the water without taste, odor, general bacteria, coliform, and other exotic substance. Such a definition has been changing recently due to the finding of numerous other inorganic and organic substances unknown to us. 10 years ago, major causes of death were infectious agents and parasites contained in water, but recently, it has become apparent that some substances contained in drinking water cause cancer and heart diseases. We must drink about 2L of water everyday in order to maintain healthy condition. Waters used for drinking include tap water, well water, spring water, filtered water, etc., but the quality of drinking water has more polluted due to the industrial development and population increase. For example, industrial waste waters from industrial plants pollute the water supply sources ; toxic substances contained in the waste waters pollute the ground water sources by penetrating the geological strata, and municipal, livestock, public building waste waters also pollute the water supply sources. Sometimes, the polluted surface waters were announced to be polluted by various kinds of orgainc substance, and it is reported that the pollution of ground water by orga nic substances has few in number but high in its concectration comparing with those of surface water. As the water quality pollution level increases, so the amount of disinfectant also increase. For example, chlorine solution, one of widely used disinfectants, creates trihalomethane(THM), a carcinogen, and halogen compounds. According to Oliver, through chlorine disinfection process, humine substance and chlorine create bolatile organic halide and nonvolatile organic halide by chemical reaction. There are tens or hundreds filtering devices, but filtering principles and maintenance metjhods are different, so their efficiency tests are needed. According to Smith, the effeciency tests aginst over 30 Ameican filtering devices show that 10 devices can remove 85% of volatile organics and further studies on filtered waters are underway. In consideration of important impacts of polluted drinking water on national health, authors studied the state of water quality pollution against tap water used as drinking water, filtration device passed water, ground water, and conserved drinking water ; tested the efficiency of filtration devices for tap water ; tried to sep up the detection method by using ion chromatography based on negative ion and positive ion by using single column, and attemped the simple filtration method for general households.

  • PDF

지하수오염 개선에 대한 지불의사액 추정 (Estimation of Household's Willingness to Pay for Ground Water Pollution Improvement)

  • 유승훈;이주석
    • 한국수자원학회논문집
    • /
    • 제43권9호
    • /
    • pp.835-842
    • /
    • 2010
  • 본 논문에서는 환경부에서 진행 중인 ‘지하수오염방지기술 개발사업’에 대한 경제성 분석의 기초자료로서 지하수오염 개선을 위한 일반가구의 지불의사액을 분석하고자 한다. 이를 위해 조건부 가치측정법(CVM)을 적용하되, CVM 연구에서 지켜야 할 다양한 지침을 엄격하게 준수하면서 가구조사를 시행하였다. 구체적으로 서울시, 인천시, 경기도 등 수도권 500 가구를 무작위로 추출하여 일대일 개별면접을 통해 '지하수오염방지기술 개발사업'에 의한 지하수오염개선을 위해 얼마나 지불할 의사가 있는지를 물었다. 응답자들은 전반적으로 조건부 시장을 잘 받아들였으며 가구당 월 평균 1,195원에서 1,552원의 지불의사액을 가지고 있는 것으로 분석되었다. 이 값을 전국으로 확장하였더니 연간 약 203.3억원에 해당 하였다. 이 값은 '지하수오염방지기술 개발사업'이 경제적으로 바람직한지 여부를 결정하기 위한 비용-편익분석에서 편익의 값으로 활용될 수 있을 것이다.

Effect of Tillage on Nonpoint Source Pollution of Surface and Ground Water System (I); Effect of Tillage Practices on Density and Saturation of Soil

  • 최정대;;류영환;최예환
    • 한국농공학회지
    • /
    • 제34권E호
    • /
    • pp.1-11
    • /
    • 1992
  • Increasing national concern on nonpoint source pollution of surface and ground water Systems has led researchers and policy makers to develop certain agricultural Best Management Practices. As an initial step of broad study program above mentioned, this study reflected the effects of different tillage practice on bulk density and degree of saturation on two regional soils, namely Tama silt loam and Catlin silt loam. Results may help to clarify some of the conflicting findings on the impact of tillage systems on these parameters and it may also explain some of the reasons for specific role that different tillage systems play regarding nonpoint source pollution from agricultural fields.

  • PDF

축산분뇨에 의한 환경오염현황과 대책 (Present State and Strategies on Environmental Pollution by Animal Wastes)

  • 이명규;이재일
    • 한국축산시설환경학회지
    • /
    • 제2권1호
    • /
    • pp.63-78
    • /
    • 1996
  • The main purpose of this research project is to monitor the present state of agricultural environment and to develope the countermeasures for the protection of the environment from the pollution by animal wastes. The results of this research were described largely 3 parts, 1) Monitoring of present state of environmental pollution by animal wastes, 2) Monitoring of animal wastes treatment technology, 3) Strategies for the protection of environmental pollution from animal wastes in future. The current most important problems from animal wastes are water pollution and air pollution commonly regardless of domestic or foreign country. Especially, intensive livestocks breeding pattern in restricted area is actually a real reason of eutrophication, soil acidification, ground water contamination, irrigation water pollution. As a result from this research project, authors recommend the 3 type of strategies for the protection of environmental pollution by animal wastes, 1 . Development of non-discharge type of wastes treatment technology 2. Manufacturing local structure for animal waste recycling system 3. Development of new international environmental program for transfer bioresource and soil environment prevention.

  • PDF

수질오염총량관리를 위한 비점배출계수 산정 - 특정 기준유량 시기의 강우배출비 (Estimation of Nonpoint Discharge Coefficient for the Management of Total Maximum Daily Load - Rainfall Discharge Ratio on the Specific Design Flow)

  • 박준대;박주현;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.452-457
    • /
    • 2008
  • Nonpoint source (NPS) pollution is caused by rainfall moving over and through the ground. As the runoff moves, it picks up and carries away various pollutants from NPS. The discharge pattern of NPS pollutant loads is affected by the distribution of the rainfall during the year. This study analysed relationship between the rainfall event and the stream flow rate, and estimated the rainfall discharge ratio on the specific design flow which can be used as nonpoint discharge coefficient for the estimation of NPS pollution load. It is considered that nonpoint discharge coefficient can be effectively used for the calculation of NPS pollution load at the time of water quality modelling for the management of Total maximum daily load (TMDL).

환경오염으로 인한 동굴생태환경의 변화와 환경오염물질 분석에 관한 연구 (A Study on the change of Ecological Environment in Cave cause by the Pollution of Cave Environment and Analysis of Environmental Pollutants in Cave)

  • 이경호
    • 동굴
    • /
    • 제61호
    • /
    • pp.5-16
    • /
    • 2000
  • Recently many environmental researcher are concerned about the ecological environment and the issue of environmental pollution in cave. In this paper we discuss about air pollution, water pollution, state of water quality, ecological environment and situation of environmental public damage in cave The concerning of air pollution in cave is mainly to the type of secondary contamination, which much is developed in various fields recently. The natural water in the most of cave is no problems but ground water has slitting with natural water during much raining period. The state of water quality is gradually contaminated with artificial environmental pollution, that is, the contents of kinds of Aluminum, Nickel, Copper, Zinc and Calcium are higher than before. On the other hand it is very important things to keep the control of constant temperature, darkness and humidity in cave. The contamination by lamp flora and even black colored contamination are appeared nowadays. The ecological environment in cave destructed by growing of mi coorganism. In fact the internal of cave is shielded with the state of climate of cave external but the environment of internal cave is contaminated, because blowing from external climate state. In addition to environmental pollution caused by carbon dioxide and body temperature of tourists. By the way eco-examination of cave is black color public damage, green color one and white color one has been discovered, so we need to have the situation of demand of environmental reservation alternatives.

  • PDF