• Title/Summary/Keyword: ground temperature

Search Result 1,614, Processing Time 0.024 seconds

Retrieval of Land SurfaceTemperature based on High Resolution Landsat 8 Satellite Data (고해상도 Landsat 8 위성자료기반의 지표면 온도 산출)

  • Jee, Joon-Bum;Kim, Bu-Yo;Zo, Il-Sung;Lee, Kyu-Tae;Choi, Young-Jean
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.2
    • /
    • pp.171-183
    • /
    • 2016
  • Land Surface Temperature (LST) retrieved from Landsat 8 measured from 2013 to 2014 and it is corrected by surface temperature observed from ground. LST maps are retrieved from Landsat 8 calculate using the linear regression function between raw Landsat 8 LST and ground surface temperature. Seasonal and annual LST maps developed an average LST from season to annual, respectively. While the higher LSTs distribute on the industrial and commercial area in urban, lower LSTs locate in surrounding rural, sea, river and high altitude mountain area over Seoul and surrounding area. In order to correct the LST, linear regression function calculate between Landsat 8 LST and ground surface temperature observed 3 Korea Meteorological Administration (KMA) synoptic stations (Seoul(ID: 108), Incheon(ID: 112) and Suwon(ID: 119)) on the Seoul and surrounding area. The slopes of regression function are 0.78 with all data and 0.88 with clear sky except 5 cloudy pixel data. And the original Landsat 8 LST have a correlation coefficient with 0.88 and Root Mean Square Error (RMSE) with $5.33^{\circ}C$. After LST correction, the LST have correlation coefficient with 0.98 and RMSE with $2.34^{\circ}C$ and the slope of regression equation improve the 0.95. Seasonal and annual LST maps represent from urban to rural area and from commercial to industrial region clearly. As a result, the Landsat 8 LST is more similar to the real state when corrected by surface temperature observed ground.

The study on the ground wire size (접지선 굵기에 관한 연구)

  • 최홍규;최병숙;송영주
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.97-102
    • /
    • 2003
  • Ground in must choose enough sectional area of conductor endurably in maximum fault current, fault duration time, maximum allowable temperature and have strong durability and life-time can bear enough from spontaneous corrosion or electrolytic corrosion and must choose material that problem does not exist electrically and mechanically when connection or junction. In this paper, modeled new ground wire size numerical formula, and examine and compare of modeled numerical formula and abroad regulation, and proved and analyzed validity of the new ground wire size computation method because do simulation to computer program.

  • PDF

Development of Numerical Analysis Model for the Calculation of Thermal Conductivity of Thermo-syphon (열 사이펀의 열전도율 산정을 위한 수치해석 모델 개발)

  • Park, Dong-Su;Shin, Mun-Beom;Seo, Young-Kyo
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.1
    • /
    • pp.5-15
    • /
    • 2021
  • The areas consisting of frost susceptible soils in cold regions, such as the Arctic area, have problems of frost heave and thaw settlement due to the seasonal air temperature changes and internal temperature of installed structures. Ground stabilization methods for preventing frost heave and thaw settlement of frost susceptible soils include trenching, backfilling and thermo-syphon. The thermo-syphon is the method in which refrigerant can control the ground temperature by transferring the ground temperature to atmosphere in the from of two-phase flow through the heat circulation of the internal refrigerant. This numerical study applied the function of these thermo-syphon as the boundary condition through user-subroutine coding inside ABAQUS and compared and analyzed the temperature results of laboratory experiments.

New measuring method for the scour and the water level by temperature measurement (온도계측을 통한 교량 세굴 및 수위 측정방법)

  • Joo, Bong-Chul;Park, Ki-Tae;Hwang, Yoon-Koog
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.553-554
    • /
    • 2009
  • This paper introduces the new measuring method for the water level and the scour. The method measures temperature between water and ground by temperature sensors. It analyzes the change of temperature. It estimates the water level and the ground level, and calculates the scour. If the temperature sensors installed until the top of the pier, it can measure the water level.

  • PDF

The Study on Experimental Method of Smoldering Ground Fire in Forest Fire (뒷불 특성에 관한 실험방법 연구)

  • Kim, Dong-Hyun;Kim, Jang-Hwan;Kim, Eung-Sik
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.1-6
    • /
    • 2010
  • A smoldering ground fire can be a probable cause of reignition of surface fire when transmitted from Fermentation layer to Humus layer with temperature higher than that of ignition. Purpose of this paper is to identify experimental methodology on the potential risk of a smoldering ground fire, which is similar to the real surface fuel bed, and its combustion characteristics. The fuel model designed in this study is composed of 3 layers such as Litter layer, Fermentation layer and Humus layer and 8 Thermocouples are set through 3 layer at each boundary and in between to detect the temperature change and duration of smoldering and propagation velocity. As a result, it was observed that ignition conditions in the boundary between L layer and F layer determined transmission and non-transmisstion to F-H layer. In addition, range of critical humidity at which a smoldering ground fire was transmitted in a material layer was 33~44% and when temperature exceeds $350^{\circ}C$, likelihood of transmission of a smoldering ground fire was high. In the research, the experimental model for multi-layer smoldering ground fire is suggested and information about propagation of smoldering fire, possibility of reignition according to moisture content, propagation velocity and temperature change are obtained, Also, the built-up methods were established to help analyze basic characteristics of smoldering ground fire.

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.47-53
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effluent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000ton/day$. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Cooling Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 냉방성능)

  • Park, Geun-Woo;Nam, Hyun-Ku;Kang, Byung-Chan
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.471-476
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}C$ annually and the quality of that water is as good as living water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and c lose type heat pump system using effluent ground water was installed and tested for it church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000$ ton/day. The heat pump capacity is 5RT each. The heat pump cooling COP is $4.9{\sim}5.2$ for the open type and $4.9{\sim}5.7$ for close type system. The system cooling COP is $3.2{\sim}4.5$ for open type and $3.8{\sim}4.2$for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

Heating Performance of Ground source Heat Pump using Effluent Ground Water (유출지하수 열원 지열히트펌프시스템의 난방성능)

  • Park, Geun-Woo;Lee, Eung-Youl
    • New & Renewable Energy
    • /
    • v.3 no.2 s.10
    • /
    • pp.40-46
    • /
    • 2007
  • Effluent ground water overflow in deep and broad ground space building. Temperature of effluent ground water is in $12{\sim}20^{\circ}...$ annually and the quality of that water is as good as well water. Therefore if the flow rate of effluent ground water is sufficient as source of heat pump, that is good heat source and heat sink of heat pump. Effuent ground water contain the thermal energy of surrounding ground. So this is a new application of ground source heat pump. In this study open type and close type heat pump system using effluent ground water was installed and tested for a church building with large and deep ground space. The effluent flow rate of this building is $800{\sim}1000\;ton/day$. The heat pump capacity is 5RT. The heat pump heating COP was $3.85{\sim}4.68$ for the open type and $3.82{\sim}4.69$ for the close type system. The system heating COP including pump power is $3.0{\sim}3.32$ for the open type and $3.32{\sim}3.84$ for close type system. This performance is up to that of BHE type ground source heat pump.

  • PDF

CFD Simulations of the Ground Surface Temperature and Air Temperature, Air flow Coupled with Solar Radiation (태양복사열에 따른 지표면 온도와 열, 기류 환경 시뮬레이션 연구)

  • Lee, JuHee;Kim, JaeGwon;Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.14 no.3
    • /
    • pp.65-70
    • /
    • 2014
  • The thermal environment in a small city rapidly deteriorates due to the urbanization and overpopulation. It is important to understand and predict the thermal environment in a city area. The thermal environment is highly affected by the solar radiation and temperature distributions changing over time periodically. To predict the thermal environment precisely, the solar radiation calculation including radiation strength, incidence angle, and thermal radiation between building surface and ground should be considered. In this study, the computational domain includes various artificial structures such as building, ground, asphalt, brick and grass. To consider the solar radiation, the unsteady state numerical calculation is performed from sun rise to mid-day (2:00pm). The numerical methods consist of solar load and one dimensional heat conduction through the boundaries to reduce the computational load and improve the flexibility of the calculation.

A Study on the Analysis of Temperature Reduction Effect by the Types of the Green Roof (옥상녹화의 녹화유형별 기온저감효과)

  • Lee, Chun-Woo;Kim, Soo-Bong;Moon, Hye-Shick
    • Journal of the Korean housing association
    • /
    • v.22 no.3
    • /
    • pp.25-33
    • /
    • 2011
  • Recently, concerns about conserving proper size of urban green spaces and accessibility are increasing, regarding it as a solution to diverse urban environmental problems including pollution, ecosystem deterioration, urban climate change. Artificial ground greening such as green roofs is regarded as the only alternative that can conserve green spaces which are impossible to be secured on the ground. However, green roofs are not popularized yet and levels are very low in provincial cities despite of related technology development and support systems of related agencies. Based on the background, this study tries to present a theoretical basis of methods for green roofs, conducting green roof simulations Finally, it aims to offer base data which help establish policy direction for activation of green roof technology. As a result of a simulation for verifying temperature reduction effect, it was possible to affirm effect of a plot that green roofs applied. Especially, it was revealed that a green roof method using ground covers such as mixed planting was the most effective way to reduce temperature. Based on precise analysis of the users, actual study for activation of green roofs should be developed in the future, by presenting a standard model for experiments and obtaining information about examples of green roofs on private houses.